Filtry
wszystkich: 1034
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: implantable assist device
-
Experimental Investigation of the Performance of an Innovative Implantable Left Ventricular Assist Device—Proof of Concept
PublikacjaThis paper presents the results of experimental performance of an innovative left ventricular assist device working on a specially designed test stand. The introduced invention is mainly applied for supporting the heart in patients with end-stage heart failure accompanied by mitral valve regurgitation and pulmonary hypertension. Moreover, the developed device has the form of a flexible balloon forming an intracardiac inert gas-filled...
-
Innovative Implantable Left Ventricular Assist Device—Performance under Various Resistances and Operating Frequency Conditions
PublikacjaThis paper presents the operation of an innovative left ventricular assist device under various resistances and operating frequencies. The operating principle of the device is based on pulsatile blood flow, which is forced by a suction–discharge device pumping helium into a set of intra-cardiac balloons. In this way, the ejection fraction of the left ventricle is increased, and the mitral valve is additionally occluded. What is...
-
COMPOSITE MATERIAL SELECTION FOR A PATIENT TRANSFER ASSIST DEVICE
PublikacjaLaminates - layered composites containing at least two elements (matrix and reinforcement) widely used in industry have also found their usage in medicine. Their main feature is the ability to modify the material in order to obtain the required properties. Depending on the needs, we can modify reinforcement, type of resin or the method of bonding substrates. Commonly used fibers are: carbon fiber, glass and aramid fibers; resins...
-
IR and microscopic studies of polyurethane surface in the polish extracorporeal ventricular assist device POLVAD-MEV
PublikacjaPurpose: The aim of this article is to show results of IR measurements and microscopicanalysis performed on layers prepared with dissolved VAD fragments and pieces ofventricular assist devices cut out of from determined VAD sectors.Design/methodology/approach: The objects of the study have been POLVAD-MEVVADs from POLCAS system. Four ventricular assist devices POLVAD-MEV have beeninvestigated with use M80 SPECORD IR spectrophotometer...
-
Effect of Vascular Lumen Reduction on the Performance and Energy Consumption of an Innovative Implantable LVAD
PublikacjaThis paper presents the results of a study on the effect of vascular lumen reduction on the performance of an innovative implantable LVAD (left ventricular assist device). It details the pressures in the individual cardiac chambers as a function of device frequency. In addition, mass flow rates and energy consumption of the device are examined, varying with lumen reduction and operating frequency. While the lumen reduction of the...
-
Methods of navigation in the mobile application supporting movement of the blind
PublikacjaThis paper presents conclusions from the last development phase of the “Voice Maps” project. Authors specify newly found available options for navigation in affordable system for the blind with all their related aspects. System uses dedicated geographical data, built-in smartphone GPS receivers and DGPS external device in order to assist blind users in their everyday travelling. Authors also discuss new methods to improve positioning...
-
LTE and NB-IoT Performance Estimation Based on Indicators Measured by the Radio Module
PublikacjaMonitoring the operating parameters of power grids is extremely important for their proper functioning as well as for ensuring the security of the entire infrastructure. As the idea of the Internet of Things becomes more ubiquitous, there are tools for monitoring the state of the complex electrical grid and means to control it. There are also developed new measuring devices and transmission technologies allowing for the transfer...
-
Optoelectronic device for hematocrit measurements
PublikacjaAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Degradation of implantable materials – in vivo and in vitro research
PublikacjaThe article concerns the biological and electrochemical degradation of metallic implants in vivo and in vitro studies. The in vivo research dealt with degradation of plates used to join bones, as well as endoprostheses. The most common damages were: metalosis, breaking in the microstructure changes, breaking in area of holes, as well as plastic deformation throughout the length of an implant. The material used for the research...
-
Device for spoofing in global positioning system
PublikacjaThis article describes the device which may be used to generate false GPS signals and emit them into radio communication channel. Such attack is called GPS spoofing. Each GPS receiver which remains in the range of a spoofing device (called spoofer) indicates time and position coordinates which are predetermined by the spoofer’s operator. Spoofing may be used e.g. in order to disable the terrorist group from obtaining correct navigation...
-
A Device for Measuring Auditory Brainstem Responses to Audio
PublikacjaStandard ABR devices use clicks and tone bursts to assess subjects’ hearing in an objective way. A new device was developed that extends the functionality of a standard ABR audiometer by collecting and analyzing auditory brainstem responses (ABR). The developed accessory allows for the use of complex sounds (e.g., speech or music excerpts) as stimuli. Therefore, it is possible to find out how efficiently different types of sounds...
-
STRUCTURE AND ALGORITHMS OF A DIAGNOSTIC DEVICE IN A WHEELED TRACTOR
PublikacjaDiagnostic device monitors the tractor’s technical condition and identifies the location of damaged components during operation. The diagnostic device detects and identifies the following types of defects: functional defects (uf) which affect performance, exhaust defects (ue) which increase toxic emissions and fuel consumption, defects that jeopardize driving safety (us), defects that affect engine performance (ud). The key component...
-
The novel sterilization device: the prototype testing
PublikacjaCurrently, there are numerous methods that can be used to neutralize pathogens (i.e., devices, tools, or protective clothing), but the sterilizing agent must be selected so that it does not damage or change the properties of the material to which it is applied. Dry sterilization with hydrogen peroxide gas (VHP) in combination with UV-C radiation is well described and effective method of sterilization. This paper presents the design,...
-
A Novel Device and System for Fall Detection Under the Shower
PublikacjaIn this paper, device construction and preliminary results for shower safety assistance are presented. The device allows monitoring of shower-taking persons without violating privacy and intimacy, while it has the ability to detect a persons entering and leaving the shower and detecting fall conditions. It allows better supervision of elders living independently at their locations.
-
Combined environmental testing device for picosatellites
PublikacjaAs access to space conditions becomes more available, both technically and economically, scientists’ interest in launching finer and more sophisticated experiments grows. To be qualified for launch, such experiments need to be carefully tested prior to the event. The tests should represent actual launch conditions as closely and in a detailed manner. Typical tests for payload include: vibration tests, thermal and vacuum tests,...
-
A New Rehabilitation Device for Balance Impaired Individuals
PublikacjaIn the paper authors present a device designed to improve the rehabilitation process of people with balance impairment. The discussed device (JStep) utilizes a commercially available static standing frame (stander) modified in order to fit force sensing units under the feet and in the pillows around the hips of a patient. While executing rehabilitation tasks, the patient may compensate his balance deficiency by leaning on the pillows...
-
Relationship between semi- and fully-device-independent protocols
PublikacjaWe study the relation between semi and fully device independent protocols. As a tool, we use the correspondence between Bell inequalities and dimension witnesses. We present a method for converting the former into the latter and vice versa. This relation provides us with interesting results for both scenarios. First, we find new random number generation protocols with higher bit rates for both the semi and fully device independent...
-
Auto adaptation of mobile device characteristics to various acoustic conditions
PublikacjaThe proposed methodology of auto adaptation of the mobile device characteristics to various acoustic conditions is presented in the paper. The first goal of this study was to determine the parameters of the acoustic path of the mobile device, for both transmitting (speaker) and receiver (microphone). Results of the measurement of characteristics of mobile devices were presented. Information about characteristics of individual parts...
-
Validation of atmospheric aerosols parallel sampling in a multifold device
PublikacjaIn this work, particulate matter was collected using an active sampling system consisting of a PM10 (<10 μm) inlet coupled to a multifold device containing six channels, connected to a vacuum pump. Each channel was equipped with a filter holder fitted with adequately chosen filters. The system was fixed on a metallic structure, which was placed on the roof of the laboratory building, at the Faculty of Sciences, in Lisbon. Sampling...
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublikacjaIn this paper the pumping effect of air in the electrohydrodynamic (EHD) device for dust particle collection is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. The asymmetric electric field and generated discharge resulted in a unidirectional airflow through the EHD device. The current-voltage characteristics...
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublikacjaIn this paper the electrohydrodynamic (EHD)device for gas pumping and cleaning is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device. The current-voltage characteristics were measured and the corona discharge...
-
Design and material selection for a patient transport device in field hospitals
PublikacjaACKGROUND: A major cause of patient and hospital worker injuries occurs transferring patients between two planes. The main aim of this paper was to propose a design of patient’s lift and transfer apparatus for use in field hospitals. The assumption was to design lightweight, durable and ergonomic device using innovative material. The authors concentrated on partial elimination of manual lifting in order to device could work both...
-
Design of a continuous intra-oral distraction device for mandibular bone
PublikacjaIn this paper we present example of a specific device used for distraction osteogenesis. Distraction osteogenesis (also called callus distraction, collotasis or osteodistraction) is a surgical process for reconstructing bone deformities or lengthening bones.
-
Low-power device simulator for micro-energy measurement methods testing
PublikacjaThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Fitting the mobile device characteristics to the user's hearing preferences
PublikacjaA method for fitting the mobile computer audio characteristics to the user's hearing preferences is proposed. The process consists of two stages: calibration and dynamics processing. During the calibration phase the user performs a loudness scaling test giving their response regarding the perceived loudness. The dynamics processing made on above basis sets the loudness to the most comfortable level. The processing accounts both...
-
Shrinking-shifting and amplifying-shifting device using transformation optics
PublikacjaBased on transformation optics (TO), this paper uses geometric divisions and linear coordinate transformations to design “shrinking-shifting—and reshaping”, and “amplifying-shifting—and reshaping” devices. The proposed devices can reshape the sizes and locations of the wrapped-objects inside the core-region. The shrinking-shifting device shrinks the larger object into a smaller one and shifts it to different location, whereas the...
-
Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization
PublikacjaThe number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its...
-
Device-independent quantum key distribution based on measurement inputs
PublikacjaWe provide an analysis of a family of device-independent quantum key distribution (QKD) protocols that has the following features. (a) The bits used for the secret key do not come from the results of the measurements on an entangled state but from the choices of settings. (b) Instead of a single security parameter (a violation of some Bell inequality) a set of them is used to estimate the level of trust in the secrecy of the key....
-
IEEE ELECTRON DEVICE LETTERS
Czasopisma -
Electronic Device Failure Analysis
Czasopisma -
Appropriate Shocks and Mortality in Patients With Versus Without Diabetes With Prophylactic Implantable Cardioverter Defibrillators
Publikacja -
Energy storage device based on flywheel, power converters and Simulink real-time
PublikacjaThis electronic document is a “live” template and already defines the components of your paper [title, text, heads, etc.] in its style sheet. Paper presents information on Energy Storage Device based on Flywheel and bi-directional IGBT Power Converters – designed for LINTE^2 laboratory owned by Gdansk University of Technology in Poland. Paper is divided into four sections. First section of the paper provides introductory information...
-
AEGIS – Mobile Device for Generating Electromagnetic Curtain for Special Applications and Countering the Threats of RCIED
PublikacjaIn the article the assumptions, design and realization of the technological demonstrator of a mobile device for generating an electromagnetic curtain (with a cryptonym AEGIS) were presented, both in the area of hardware and software. The device is designed to block the radio communication systems by which it is possible to detonate the Radio Controlled Improvised Explosive Devices (RCIEDs). The preliminary laboratory tests of the...
-
Pre-swirl energy saving device in marine application
PublikacjaThis paper covers topics of energy saving device (ESD) with application to marine propulsors. The form of ESD, considered in this paper, consists of fixed lifting foils mounted in front of the screw propeller (the pre-swirl stator/guide vanes). An algorithm for designing propulsion systems, consisting of guide vanes and screw propeller, is presented. The proposed method relies on hybrid lifting line (guide vanes)-lifting surface...
-
A macroscopic device for quantum computation
PublikacjaPrzeanalizowano mechaniczny model kwantowego układu 2-bitowego. Model jest zilustrowany algorytmem Deutscha i Arvinda.
-
Selection of pointing device for elders
PublikacjaW artykule przedstawiono metodykę i sposób akwizycji oraz analizy danych dla doboru optymalnego urządzenia wskazującego, dostosowanego do osób starszych. Przedstawiono wyniki próbnych testów na dwóch grupach - docelowej i referencyjnej oraz skomentowano wyniki.
-
Pumping effect measured by PIV method in a multilayer spike electrode EHD device for air cleaning
PublikacjaDust particles can be harmful for human health when inhaled. Particularly dangerous are submicrometer dust particles, which can contain traces of toxic elements and can easily penetrate into the human respiratory system. Thus, efficient devices for the air cleaning from submicrometer dust particles are needed. Recently, Katatani and Mizuno have proposed an electrohydrody- namic (EHD) device for air cleaning for submicrometer particles....
-
A navigation device utilizing body communication channel for mobile wearable systems
PublikacjaA novel touch sensor utilizing a body communication technology is presented in the paper. The proposed device accepts orders (gestures) only from a person wearing it. Moreover, when comparing it to a similar, however an optical one, it appears as a less power consumable. Preliminary results of its properties examination are presented and discussed. Additionally, the developed sensor allows to measure a human body the electrical...
-
Experimental certification of an informationally complete quantum measurement in a device-independent protocol
PublikacjaMinimal informationally complete positive operator-valued measures (MIC-POVMs) are special kinds of measurement in quantum theory in which the statistics of their d2-outcomes are enough to reconstruct any d-dimensional quantum state. For this reason, MIC-POVMs are referred to as standard measurements for quantum information.Here, we report an experiment with entangled photon pairs that certifies, for what we believe is the first...
-
A device for measuring heat flux on a rocket skin surface
PublikacjaA novel method for measuring heat flux on a surface is presented. It is an extensive upgrade of currently known heat flux sensors used mostly in civil engineering. As the thermal environment of launchers, especially sounding rocket can have an enormous negative effect on payload, careful considerations have to be taken in the process of preparing insulation. Usually, thermal data provided by the launch vehicle manufacturer is limited...
-
Analysis of noise properties of the optocoupler device
PublikacjaIn the paper the localization of a source of Random Telegraph Signal noise (RTS noise) in optocoupler devices type CNY 17 were defined. The equivalent noise circuit in low frequency noise for these type optocouplers was proposed.
-
Experimentally feasible semi-device-independent certification of four-outcome positive-operator-valued measurements
PublikacjaRecently the quantum information science community devoted a lot of attention to the theoretical and practical aspects of generalized measurements, the formalism of all possible quantum operations leading to acquisition of classical information. On the other hand, due to imperfections present in quantum devices, and limited thrust to them, a trend of formulating quantum information tasks in a semi-device-independent manner emerged....
-
IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY
Czasopisma -
Pumping effect measured by PIV method in multi-layer spike electrode EHD device for air cleaning
PublikacjaDust particles can be harmful for human health when inhaled. Especially dangerous are submicron dust particles, which can contain traces of toxic elements and can easily penetrate into human respiratory system. Thus, new devices for air cleaning are needed. In this work the flow velocity field patterns measured by Particle Image Velocimetry (PIV) method in an electrohydrodynamic (EHD) device for air cleaning are presented. The...
-
Evaluating the Use of Edge Device Towards Fall Detection in Smart City Environment
PublikacjaThis paper presents the development and preliminary testing of a fall detection algorithm that leverages OpenPose for real-time human pose estimation from video feeds. The system is designed to function optimally within a range of up to 7 meters from ground-level cameras, focusing exclusively on detected human silhouettes to enhance processing efficiency. The performance of the proposed approach was evaluated using accuracy values...
-
Increased Certification of Semi-device Independent Random Numbers using Many Inputs and More Postprocessing
PublikacjaQuantum communication with systems of dimension larger than two provides advantages in information processing tasks. Examples include higher rates of key distribution and random number generation. The main disadvantage of using such multi-dimensional quantum systems is the increased complexity of the experimental setup. Here, we analyze a not-so-obvious problem: the relation between randomness certification and computational requirements...
-
Quantitative criteria for needle trap device selection
Publikacja -
Effectiveness of in-needle extraction device for liquid samples
Publikacja -
Wireless short-range device for wind generators
Publikacja -
Novel Design of an Ocean Wave Power Device
PublikacjaW artykule przedstawiono nowoczesną boję energetyczną o opatentowanej konstrukcji. Omówiono jej konstrukcję oraz przedstawiono problemy konstrukcyjne i badawcze. W ostatniej części artykułu przedstawiono wyniki badań wykonanych na modelu w basenie modelowym.