Filtry
wszystkich: 1580
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: contact capacitive imaging
-
Influence of hydrochloric acid concentration and type of nitrogen source on the electrochemical performance of TiO2/N-MoS2 for energy storage applications
PublikacjaIn this work, nitrogen-doped molybdenum sulfide was directly deposited on titanium dioxide nanotubes substrate (TiO2/N-MoS2) during hydrothermal synthesis. The study focuses on the influence of hydrochloric acid concentration used for the synthesis, with the results indicating its essential role in thioacetamide hydrolysis and thus in the effectiveness of the N-MoS2 deposition. The electrode material itself is characterized by...
-
Assessing Acute Toxicity of Selected Packages Internal Layers Extracts using Microtox®
PublikacjaIn the scientific literature related to the widely understood issue of packaging materials designed to have contact with food (food contact materials), there is much information on raw materials used for their production, as well as their physiochemical properties, types and parameters. Unfortunately, not much attention is given to the issues concerning migration of toxic substances from packaging and its actual influence on the...
-
Centrally Pivoted Tilting Pad Thrust Bearing with Carbon-Based Coated Collar—Experimental Results of Low- and Medium-Speed Operation
PublikacjaExperimental results of the research on a tilting pad thrust bearing with symmetrical pad support in the conditions of high loads and low speeds are presented in the paper. As described in the literature review, experimental results of tilting pad bearings at low speed/high load regime and transient conditions are rare. Unusual material selection - steel pad against a DLC-type coating on the collar was utilized. Such material combination...
-
Three Principles for Healthy Living with Light and Lighting
PublikacjaThe lockdown measures applied to cities and towns during the worldwide Covid-19 pandemic have had a widespread impact on people’s lives. Some have found themselves confined to their homes, with limited social contact and a reduced quality of life. Others have found that the lockdown improved their wellbeing, as more time was spent outside, instead of commuting and working in an office building, plus the benefits of spending increased...
-
Evaluation of Langmuir and Freundlich Isotherms for Removal of Cephalexin and Tetracycline Antibiotics By Sistan Sand from Water and Wastewater Samples
PublikacjaIn this research, Sistan sand was used as a natural and inexpensive sorbent for removal of cephalexin and tetracycline antibiotics from water and wastewater samples. For a concentration 60.0 mg L-1 of cephalexin, optimum removal conditions were: pH of the sample 3.0, adsorbent amount 1.0 g, contact time 20.0 min, added amount of sodium chloride to adjust the ionic strength of the solution 7.0 g L-1. Langmuir isotherm was the best...
-
Micro-modelling of shear localization during quasi-static confined granular flow in silos using DEM
PublikacjaThe paper deals with the quasi-static confined flow of cohesionless sand in a plane strain model silo with parallel walls and a slowly movable bottom. Numerical modelling was carried out by the discrete element method (DEM) using spheres with contact moments to approximately capture a non-uniform shape of sand particles. Different initial void ratios of sand and silo wall roughness grades were employed. Regular triangular grooves...
-
Optical Magnetometry Based on Nanodiamonds with Nitrogen-Vacancy Color Centers
PublikacjaNitrogen-vacancy color centers in diamond are a very promising medium for many sensing applications such as magnetometry and thermometry. In this work, we study nanodiamonds deposited from a suspension onto glass substrates. Fluorescence and optically detected magnetic resonance spectra recorded with the dried-out nanodiamond ensembles are presented and a suitable scheme for tracking the magnetic-field value using a continuous...
-
Non-Destructive Assessment of Masonry Pillars using Ultrasonic Tomography
PublikacjaIn this paper, a condition assessment of masonry pillars is presented. Non-destructive tests were performed on an intact pillar as well as three pillars with internal inclusions in the form of a hole, a steel bar grouted by gypsum mortar, and a steel bar grouted by cement mortar. The inspection utilized ultrasonic stress waves and the reconstruction of the velocity distribution was performed by means of computed tomography. The...
-
AITP - AI Thermal Pedestrians Dataset
PublikacjaEfficient pedestrian detection is a very important task in ensuring safety within road conditions, especially after sunset. One way to achieve this goal is to use thermal imaging in conjunction with deep learning methods and an annotated dataset for models training. In this work, such a dataset has been created by capturing thermal images of pedestrians in different weather and traffic conditions. All images were manually annotated...
-
Diagnostyka off-line stanu izolacji uzwojeń silników 6 kV z wykorzystaniem obrazowania akustycznego wyładowań niezupełnych
PublikacjaW zakładach przemysłowych, w których kluczowe procesy produkcyjne są realizowane z wykorzystaniem silników średniego napięcia, dla których diagnostyka izolacji uzwojeń ma istotne znaczenie. W tym celu wykonuje się ocenę porównawczą wyników pomiarów wyładowań niezupełnych (WNZ) wykonywanych dla jednostek tego samego typu, a jej skuteczność w znacznej mierze wynika z wieloletniego doświadczenia diagnosty. Dla opracowania wyników...
-
DLC coating in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
Wear of Ultra-thin DLC or Tungsten-modified DLC Coatings under Reciprocating Sliding
PublikacjaIn the paper results are presented from tests in reciprocating sliding of self mated specimens of DLC and tungsten modified DLC coatings on stainless steel substrate. The contact geometry chosen for the research task was ball on flat. The contacts were lubricated either with distilled water or medical saline solution. Results are presented with regard to wear resistance as a function of material type and lubricant used.
-
Validation of result of STM probe fabrication
Dane BadawczeThe scanning tunneling microscope [1] is a powerful research tool that allows, among other things, to obtain images with atomic resolution. A serious limitation of the described microscope is its limited applicability relating to conductive and semiconductor materials and the reproducibility of measurements depending on the preparation of the measuring...
-
Investigation of the electrochemical behaviour of AA1050 aluminium alloy in aqueous alkaline solutions using Dynamic Electrochemical Impedance Spectroscopy
PublikacjaThe paper presents the electrochemical behaviour of aluminium alloy AA1050 in aqueous alkaline media in the pH range 14–8.5. Electrochemical study was applied in order to obtain comprehensive information on the mechanism and kinetics of the process of anodic dissolution of aluminium, supplemented by monitoring of surface topography using an electron microscope. The corrosion rate of AA1050 increases with increasing concentration...
-
Research on Quality Requirements of Data Transmission Services in RSMAD
PublikacjaThe paper presents a results and analysis of research of the quality of service requirements (defined by the QoS attributes) for imaging data transmission services using Radio System for Monitoring and Acquisition of Data from Traffic Enforcement Cameras (in short RSMAD). The paper also presents and discusses results of test on the impact of the size of photos from traffic enforcement cameras on the average transmission time. These...
-
Pre-oxidation of porous ferritic Fe22Cr alloys for lifespan extension at high-temperature
PublikacjaPre-oxidation of porous ferritic Fe22Cr alloys was extensively studied in this paper. Weight gain measurements and SEM analysis revealed that pre-oxidation performed at 900◦C for 40 min increased the lifespan of the alloy. A Cr evaporation study did not disclose any significant influence of the pre-oxidation process on the Cr content in the alloy. For a more detailed assessment, TEM imaging and X-ray tomography measurements of...
-
Detection of debonding in reinforced concrete beams using ultrasonic transmission tomography and hybrid ray tracing technique
PublikacjaThis paper concerns inspection of reinforced concrete elements, with particular emphasis on assessing the quality of the adhesive connection between steel and concrete. A novel theoretical model was developed to determine the paths of transmitted, refracted and reflected elastic waves as well as a creeping wave propagated along the inclusion surface. Imaging the internal structure of tested beams was based on wave propagation measurements...
-
Abdominal Aortic Aneurysm segmentation from contrast-enhanced computed tomography angiography using deep convolutional networks
PublikacjaOne of the most common imaging methods for diagnosing an abdominal aortic aneurysm, and an endoleak detection is computed tomography angiography. In this paper, we address the problem of aorta and thrombus semantic segmentation, what is a mandatory step to estimate aortic aneurysm diameter. Three end-to-end convolutional neural networks were trained and evaluated. Finally, we proposed an ensemble of deep neural networks with underlying...
-
The analysis of temperature changes of the saliva traces left on the fur during laboratory rats social contacts
PublikacjaAutomatic analysis of complex rodent social be- havior, especially aggressive ones, is of important scientific interest. In this paper we analyze the properties of the data created as a result of aggressive rodent social behavior. Detec- tion of specific aggressive behaviors is based on the event of leaving traces of saliva on the fur of the attacked individual, which are clearly visible in the thermal imaging. The traces change...
-
Sonar Pulse Detection Using Chirp Rate Estimation and CFAR Algorithms
PublikacjaThis paper presents a new approach to sonar pulse detection. The method uses chirp rate estimators and algorithms for the adaptive threshold, commonly used in radiolocation. The proposed approach allows detection of pulses of unknown parameters, which may be used in passive hydrolocation or jamming detection in underwater communication. Such an analysis is possible thanks to a new kind of imaging, which presents signal energy in...
-
Mariusz Franciszek Kaszubowski dr
OsobyBiogram Mariusz Kaszubowski jest adiunktem w Katedrze Statystyki i Ekonometrii Wydziału Zarządzania i Ekonomii Politechniki Gdańskiej. Prowadzi zajęcia ze statystyki opisowej i matematycznej, a także statystyki społecznej i statystyki ubezpieczeniowej. Wykłada również statystykę na podyplomowych studiach z kontroli jakości „Lean Six Sigma Black Belt”. Jest absolwentem dwóch kierunków studiów: Zarządzania (specjalność Statystyka...
-
Life tests of a rotary single-stage magnetic-fluid seal for shipbuilding applications
PublikacjaUse of the magnetic fluid seal technology in water is much more difficult technological problem in comparisonto gas or vacuum environment. Some seals constructed up to time been are designed as hybrid, two stagesealing structures with shields or mechanical seals used as protection measures to the magnetic fluid seal.Anyway, there is always problem with immediate contact between magnetic fluid and the environmentalliquid. In the...
-
Multi-stage magnetic-fluid seals for operating in water - life test procedure, test stand and research results
PublikacjaThe edge criteria for magnetic-fluid seals durability research are critical for the seal'stechnological usefulness. The magnetic fluid seal technology in water is much moredifficult technological problem in comparison to gas or vacuum environment. There isalways problem with immediate contact between magnetic fluid and the environmentaluninspected liquids. In the paper are presented ways of experiments definitions carried outwith...
-
Improving Accuracy of Respiratory Rate Estimation by Restoring High Resolution Features With Transformers and Recursive Convolutional Models
PublikacjaNon-contact evaluation of vital signs has been becoming increasingly important, especially in light of the COVID- 19 pandemic, which is causing the whole world to examine people’s interactions in public places at a scale never seen before. However, evaluating one’s vital signs can be a relatively complex procedure, which requires both time and physical contact between examiner and examinee. These re- quirements limit the number...
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
Qualitative analysis of phospholipids and their oxidised derivatives – used techniques and examples of their applications related to lipidomic research and food analysis
PublikacjaPhospholipids (PLs) are important biomolecules that not only constitute structural building blocks and scaffolds of cell and organelle membranes, but also play a vital role in cell biochemistry and physiology. Moreover, dietary exogenous PLs are characterized by high nutritional value and other beneficial health effects, which are confirmed by numerous epidemiological studies. For this reason, PLs are of high interest in lipidomics...
-
A Comparability of Renal Length and Volume Measurements in MRI and Ultrasound in Children
PublikacjaIntroduction: Despite the significant increase in use of magnetic resonance imaging (MRI) in children, there is still a lack of normal reference values of renal size in this method and reference values are being interpolated from the ultrasound (US) studies. The study provides comparative analysis of agreement in renal length and volume measurements between MRI and ultrasound. Materials and Methods: Ninety-three children with a...
-
Aneta Sobiechowska-Ziegert dr
OsobyPracuje w Katedrze Statystyki i Ekonometrii na Wydziale Zarządzania i Ekonomii, pasjonatka stosowania nowoczesnych metod dydaktycznych w nauczaniu przedmiotów ilościowych, dyplomowany coach i certyfikowana tutorka. Prowadzi zajęcia z prognozowania gospodarczego i ekonometrii przestrzennej. Przewodniczy Wydziałowej Komisji Jakości Kształcenia i opiekuje się ścieżką kształcenia EMOS, certyfikowaną przez Eurostat. Obecnie koordynuje...
-
Andrzej Okuniewski dr inż.
OsobyWykształcenie 2010-2014: Katedra Chemii Nieorganicznej, Wydział Chemiczny, Politechnika Gdańskadoktor nauk chemicznych (nauki chemiczne – chemia, chemia nieorganiczna) 2009-2010: Wydział Chemiczny, Politechnika Gdańskamagister chemii (chemia stosowana) 2005-2009: Wydział Chemiczny, Politechnika Gdańskainżynier chemik (chemia stosowana) 2002-2005: II Liceum Ogólnokształcące im. Władysława Pniewskiego w Gdańskuprofil biologiczno-chemiczno-fizyczny...
-
AUGMENTATION OF THE CRITICAL HEAT FLUX IN WATER-Al2O3, WATER-TiO2 AND WATER-Cu NANOFLUIDS
PublikacjaThe main aim of the proposed study is therefore recognition of the phenomena accompanying nucleate boiling crisis of selected nanofluids during boiling on horizontal tubes of various outside diameters. Of particular interest is impact of contact angle and tube diameter on the value of critical heat flux. The results obtained should give more light on the nature of nucleate boiling crisis and will serve as a basis for future theoretical...
-
Comparative modeling of shear localization in granular bodies with FEM and DEM
PublikacjaThe intention of the paper is to compare the calculations of shear zones in granular bodies using two different approaches: a continuum and a discrete one. In the first case, the FEM based on a micro-polar hypoplastic constitutive law was used. In the second case, the DEM was taken advantage of, where contact moments were taken into account to model grain roughness. The comparative calculations were performed for a passive case...
-
Thermal sequences database of the skin flaps in breast reconstruction and burns
PublikacjaThis paper presents a database of Active Dynamic Thermography (ADT) thermal sequences gathered throughout 6 year study on ADT application in skin flap blood perfusion monitoring and burn wounds diagnosis. For skin flap monitoring the database comprises of data collected during three different breast reconstruction procedures. The patients were monitored pre, intra and post surgically within 90 days period. The sequences were used...
-
RMS-based damage detection in reinforced concrete beams: numerical simulations
PublikacjaImage-based damage detection methods using guided waves are well known and widely applied approaches in structural diagnostics. They are usually utilized in detection of surface damages or defects of plate-like structures. The article presents results of the study of applicability of imaging wave-based methods in detection in miniscule internal damage in the form of debonding. The investigations were carried out on numerical models...
-
Thermal sequences database of the skin flaps in breast reconstruction and burns
PublikacjaThis paper presents a database of Active Dynamic Thermography (ADT) thermal sequences gathered throughout 6 year study on ADT application in skin flap blood perfusion monitoring and burn wounds diagnosis. For skin flap monitoring the database comprises of data collected during three different breast reconstruction procedures. The patients were monitored pre, intra and post surgically within 90 days period. The sequences were used...
-
The influence of the distance of the pyrometer from the surface of the radiating object on the accuracy of measurements
Dane BadawczeDuring the COVID-19 epidemic, non-contact body temperature measurement has become very important. This dataset contain results of measurements of the four professional commercially available pyrometers. The CHY 314P, TM-F03B, TFA 31.1125 and Abatronic AB-8855 where tested in function of measuring distance from the surface of the radiating black body....
-
Effects of electrophoretic deposition times and nanotubular oxide surfaces on properties of the nanohydroxyapatite/nanocopper coating on the Ti13Zr13Nb alloy
PublikacjaLoad-bearing implants are developed with a particular emphasis placed on an application of ceramic hydroxyapatite coatings in order, to enhance the bioactivity of titanium implants and to shorten the healing time. Therefore, thin, fully crystalline coatings that are, highly adhesive, hydrophilic and demonstrating antibacterial properties are ly looked for. The aim of this research was to develop and characterize the properties...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublikacjaThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Wpływ wysokiej osteotomii piszczelowej na mechanikę stawu kolanowego
PublikacjaW rozprawie podjęto próbę weryfikacji wpływu zabiegu chirurgicznego wysokiej osteotomii piszczelowej na mechanikę stawu kolanowego. Po wykonanym przeglądzie literatury, postawiono trzy hipotezy, które poddano weryfikacji na drodze badań numerycznych. Otrzymane wyniki zwalidowano poprzez badania nacisków powierzchniowych występujących w stawach kolanowych świni domowej, prowadzonych na maszynie do jednoosiowego ściskania. Praca...
-
Quality Evaluation of Speech Transmission via Two-way BPL-PLC Voice Communication System in an Underground Mine
PublikacjaIn order to design a stable and reliable voice communication system, it is essential to know how many resources are necessary for conveying quality content. These parameters may include objective quality of service (QoS) metrics, such as: available bandwidth, bit error rate (BER), delay, latency as well as subjective quality of experience (QoE) related to user expectations. QoE is expressed as clarity of speech and the ability...
-
Subjective Quality Evaluation of Underground BPL-PLC Voice Communication System
PublikacjaDesigning a reliable voice transmission system is not a trivial task. Wired media, thanks to their resistance to mechanical damage, seem an ideal solution. The BPL-PLC (Broadband over Power Line – Power Line Communication) cable is resilient to electricity stoppage and partial damage of phase conductors. It maintains continuity of transmission in case of an emergency situation, including paramedic rescue operations. These features...
-
Investigating lubricants behaviour in microgravity for vibration damping purposes
PublikacjaVibration is one of the harshest environments an object is exposed to during and after launch into space on a launch vehicle. Such vibrations should be damped to avoid destruction of the spacecraft or its elements. Currently, active and material damping is used. A possibility of using lubrication as the damping factor is suggested by some research. MoS2 is a typical solid lubricant used in space applications. Its properties vary...
-
Study of the effect of adiabatic heating on the operation of the electrodynamic actuator
PublikacjaElectrodynamic actuators are used in hybrid switching systems where a very quick contact separation as well as operation repeatability and long-term reliability are required. The article presents selected results of thermal studies in the electrodynamic drive system. Study was carried out on the basis of the 3D electromagneto-thermal model implemented in the Ansys_Maxwell environment. The present model allows to determine the critical...
-
The Palais–Smale condition for the Hamiltonian action on a mixed regularity space of loops in cotangent bundles and applications
PublikacjaWe show that the Hamiltonian action satisfies the Palais-Smale condition over a “mixed regular- ity” space of loops in cotangent bundles, namely the space of loops with regularity H^s, s ∈ (1/2, 1), in the baseand H^{1−s} in the fiber direction. As an application, we give a simplified proof of a theorem of Hofer-Viterbo on the existence of closed characteristic leaves for certain contact type hypersufaces in cotangent bundles.
-
On solvability of initial boundary-value problems of micropolar elastic shells with rigid inclusions
PublikacjaThe problem of dynamics of a linear micropolar shell with a finite set of rigid inclusions is considered. The equations of motion consist of the system of partial differential equations (PDEs) describing small deformations of an elastic shell and ordinary differential equations (ODEs) describing the motions of inclusions. Few types of the contact of the shell with inclusions are considered. The weak setup of the problem is formulated...