wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: optical properties
-
Application of Thin ZnO ALD Layers in Fiber-Optic Fabry-Pérot Sensing Interferometers
PublikacjaIn this paper we investigated the response of a fiber-optic Fabry-Pérot sensing interferometer with thin ZnO layers deposited on the end faces of the optical fibers forming the cavity. Standard telecommunication single-mode optical fiber (SMF-28) segments were used with the thin ZnO layers deposited by Atomic Layer Deposition (ALD). Measurements were performed with the interferometer illuminated by two broadband sources operating...
-
Au nanostructures coated with a ultrathin film of Al2O3 - measurements and FDTD simulations
Dane BadawczeGold plasmonic platforms have been coated with an ultra-thin films of aluminium oxide. Optical measurements, showing the influence of the thickness of Al2O3 on plasmon resonance position. The observed red-shift of the resonance location with the increase of the thickness of the Al2O3 film, can be explained by the change in the dielectric function of...
-
An Improved Synthesis of Trisodium (R)-Homocitrate from Citric Acid
PublikacjaA method of synthesis of trisodium (R)-homocitrate starting from citric acid is reported. The procedure affords the final product of high optical purity with satisfactory yield.
-
The absorption and fluorescence spectra of C-1305 derivatives (IKE1-IKE8), potential antifungal agents
Dane BadawczeOptical measurements of C-1305 derivatives (IKE1-IKE8). The absorption spectra were recorded at 300 - 800 nm for solutions with 16 μg / mL derivative concentration. The fluorescence emission spectra were determined at 420-800 nm with the excitation wavelengths 360 or 415 nm for solutions with 1 μg / mL derivative concentration. All measurements were...
-
Fiber optic microsphere with a ZnO thin film for potential application in a refractive index sensor – theoretical study
PublikacjaOptical fiber sensors of refractive index play an important role in analysis of biological and chemical samples. This work presents a theoretical investigation of spectral response of a fiber optic microsphere with a zinc oxide (ZnO) thin film deposited on the surface and evaluates the prospect of using such a structure for refractive index sensing. A microsphere is fabricated by an optical fiber tapering method on the base of...
-
Enhancing Resilience of FSO Networks to Adverse Weather Conditions
PublikacjaOptical wireless networks realized by means of gigabit optical wireless communication (OWC) systems are becoming, in a variety of applications, an important alternative, or a complementary solution, to their fiber-based counterparts. However, performance of the OWC systems can be considerably degraded in periods of unfavorable weather conditions, such as heavy fog, which temporarily reduce the effective capacity of the network....
-
Sensors integration in the smart home environment - a proposal to solve the problem with user identification
PublikacjaIn this preliminary study we, investigate the possibility of user recognition techniques suitable on smart home devices like chairs, beds, aiming for low–power, high accuracy and quick response time. We propose the two well know technique: voice speaker recognition and accelerometer signal from device mounted on the chair, and the third one optical system basing on IR LED transmitter/receiver circuit. The preliminary results proved...
-
Enhanced Eye-Tracking Data: a Dual Sensor System for Smart Glasses Applications
PublikacjaA technique for the acquisition of an increased number of pupil positions, using a combined sensor consisting of a low-rate camera and a high-rate optical sensor, is presented in this paper. The additional data are provided by the optical movement-detection sensor mounted in close proximity to the eyeball. This proposed solution enables a significant increase in the number of registered fixation points and saccades and can be used...
-
Excitation energy transfer in partly ordered polymer films differing in donor and acceptor transition moments orientation
PublikacjaBased on spectroscopic measurements selected properties of nonradiative Förster energy transport are studied in uniaxially stretched polyvinyl alcohol thin films for three systems differing in donor and acceptor transition moments orientation relative to the axis of stretching. In particular, donor – acceptor emission anisotropy spectra yield completely different regularities for these systems in uniaxially stretched films, whereas...
-
Magnetic switching of Kerker scattering in spherical microresonators
PublikacjaMagneto-optical materials have become a key tool in functional nanophotonics, mainly due to their ability to offer active tuning between two different operational states in subwavelength structures. In the long-wavelength limit, such states may be considered as the directional forward- and back-scattering operations, due to the interplay between magnetic and electric dipolar modes, which act as equivalent Huygens sources. In this...
-
Biophotonic low-coherence sensors with boron-doped diamond thin layer
PublikacjaLow-coherence sensors using Fabry-Perot interferometers are finding new applications in biophotonic sensing, especially due to the rapid technological advances in the development of new materials. In this paper we discuss the possibility of using boron-doped nanodiamond layers to protect mirror in a Fabry-Perot interferometer. A low-coherence sensor using Fabry-Perot interferometer with a boron-doped nanodiamond (B-NCD) thin protective...
-
Shrinking-shifting and amplifying-shifting device using transformation optics
PublikacjaBased on transformation optics (TO), this paper uses geometric divisions and linear coordinate transformations to design “shrinking-shifting—and reshaping”, and “amplifying-shifting—and reshaping” devices. The proposed devices can reshape the sizes and locations of the wrapped-objects inside the core-region. The shrinking-shifting device shrinks the larger object into a smaller one and shifts it to different location, whereas the...
-
The finite-difference simulation of x-rays propagation through a system of lenses
PublikacjaThe propagation of X-ray waves through an optical system consisting of 33 aluminum X-ray refractive lenses is considered. For solving the problem, a finite-difference method is suggested and investigated. It is shown that very small steps of the difference grid are necessary for reliable computation of propagation of X-ray waves through the system of lenses. It is shown that the wave phase is a function very quickly increasing...
-
Optoelectronic investigation of nanodiamond interactions with human blood
PublikacjaWe present optoelectronic investigation of in vitro interactions of whole human blood with different nanodiamond biomarkers. Plasmo-chemical modifications of detonation nanodiamond particles gives the possibility for controlling their surface for biological applications. Optical investigations reveal the biological activity of nanodiamonds in blood dependent on its surface termination. We compare different types of nanodiamonds:...
-
A high-accuracy complex-phase method of simulating X-ray propagation through a multi-lens system
PublikacjaThe propagation of X-ray waves through an optical system consisting of many X-ray refractive lenses is considered. For solving the problem for an electromagnetic wave, a finite-difference method is applied. The error of simulation is analytically estimated and investigated. It was found that a very detailed difference grid is required for reliable and accurate calculations of the propagation of X-ray waves through a multi-lens...
-
Thickness and structure change of titanium (IV) oxide thin films synthesized by the sol–gel spin coating method
PublikacjaTitanium dioxide is a well-known material in nanotechnology, while it provides new opportunities due to its interesting properties, for example, as a semiconductor with a quite significant forbidden band gap energy of 3.2 eV. In this study, thin films of titanium dioxide (TiO2) were synthesized in amorphous and crystallographic systems using the sol–gel process. Atomic Force Microscopy (AFM), Raman spectroscopy and X-ray diffraction...
-
Visual Detection of People Movement Rules Violation in Crowded Indoor Scenes
PublikacjaThe paper presents a camera-independent framework for detecting violations of two typical people movement rules that are in force in many public transit terminals: moving in the wrong direction or across designated lanes. Low-level image processing is based on object detection with Gaussian Mixture Models and employs Kalman filters with conflict resolving extensions for the object tracking. In order to allow an effective event...
-
Application of thin diamond films in low-coherence fiber-optic Fabry Pérot displacement sensor
PublikacjaThe novel fiber-optic low coherence sensor with thin diamond films is demonstrated. The undoped and boron-doped diamond films were elaborated by the use of the microwave plasma enhanced chemical vapor deposition (μPE CVD) system. The optical signal from the Fabry–Pérot cavity made with the application of those thin films is sensitive to displacement. The sensor characterization was made in the range of 0–600 μm. The measurements...
-
Fiber optic low-coherence Fabry-Pérot interferometer with ZnO layers in transmission and reflective mode: comparative study
PublikacjaA construction of a low-coherence fiber-optic Fabry-Pérot interferometer using a thin ZnO layer as a reflective surfaces was proposed and examined. In the investigated setup, the ZnO layer of thickness 200 nm were deposited on the face of the standard telecommunication single-mode optical fiber (SMF-28). Measurements of interference signal were performed for the interferometer working in the transmission and reflective mode, as...
-
Data obtained by computation for X-ray imaging of grating with magnification factor equal 2 using oriented Gaussian beams
Dane BadawczeThe propagation of X-ray waves through an optical system consisting of grating and X-ray refractive lenses is considered. In this approach, the propagating wave is represented as a superposition of the oriented Gaussian beams. The direction of wave propagation in each Gaussian beam is consistent with the local propagation direction of the X-ray wavefront.
-
Data obtained by computation for X-ray imaging of grating with magnification factor equal 4 using oriented Gaussian beams
Dane BadawczeThe propagation of X-ray waves through an optical system consisting of grating and X-ray refractive lenses is considered. In this approach, the propagating wave is represented as a superposition of the oriented Gaussian beams. The direction of wave propagation in each Gaussian beam is consistent with the local propagation direction of the X-ray wavefront.
-
Data obtained by computation for X-ray imaging of grating with magnification factor equal 8 using oriented Gaussian beams
Dane BadawczeThe propagation of X-ray waves through an optical system consisting of grating and X-ray refractive lenses is considered. In this approach, the propagating wave is represented as a superposition of the oriented Gaussian beams. The direction of wave propagation in each Gaussian beam is consistent with the local propagation direction of the X-ray wavefront.
-
Data obtained by computation for X-ray imaging of grating without magnification using oriented Gaussian beams
Dane BadawczeThe propagation of X-ray waves through an optical system consisting of grating and X-ray refractive lenses is considered. In this approach, the propagating wave is represented as a superposition of the oriented Gaussian beams. The direction of wave propagation in each Gaussian beam is consistent with the local propagation direction of the X-ray wavefront.
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Luminescence of TeO2:Eu thin films
Dane BadawczeTellurium dioxide doped by europium thin films were deposited by magnetron sputtering method and simultaneously heated at 200 oC. Presence of Eu ions and their valence states was confirmed by X-ray photoemission spectroscopy measurements. The structure of the films as well as the influence of europium dopant on crystalline structure of the films was...
-
Mechanical exfoliation and layer number identification of single crystal monoclinic CrCl3
PublikacjaAfter the recent finding that CrI3, displays ferromagnetic order down to its monolayer, extensive studies have followed to pursue new two-dimensional (2D) magnetic materials. In this article, we report on the growth of single crystal CrCl3 in the layered monoclinic phase. The system after mechanical exfoliation exhibits stability in ambient air (the degradation occurs on a time scale at least four orders of magnitude longer than...
-
Model of control plane of ASON/GMPLS network
PublikacjaASON (Automatic Switched Optical Network) is a concept of optical network recommended in G.8080/Y.1304 by ITU-T. Control Plane of this network could be based on GMPLS (Generalized Multi-Protocol Label Switching) protocols. This solution, an ASON control plane built on GMPLS protocols is named ASON/GMPLS. In the paper, we decompose the control plane problem and show the main concepts of ASON network. We propose a hierarchical architecture...
-
Determination of refractive index dispersion using fiber-optic low-coherence Fabry–Perot interferometer: implementation and validation
PublikacjaWe present the implementation and validation of low-coherence Fabry–Perot interferometer for refractive index dispersion measurements of liquids. A measurement system has been created with the use of four superluminescent diodes with different optical parameters, a fiber-optic coupler and an optical spectrum analyzer. The Fabry–Perot interferometer cavity has been formed by the fiber-optic end and mirror surfaces mounted on a micromechanical...
-
Polarimetric studies of L-arginine-doped potassium dihydrogen phosphate single crystals
PublikacjaConoscopic interference patterns, channelled spectra and polarimetric techniques have been used for the characterization of pure and doped (with L-arginine amino acid) potassium dihydrogen phosphate (KDP) single crystals. Experimental polarimetric data have been obtained for the frequently used wavelength of 633 nm and for two close wavelengths of 532 and 543 nm in a high-accuracy dual-wavelength polarimeter. The measurement of...
-
Fiber optic displacement sensor with signal analysis in spectral domain
PublikacjaIn this paper, a study of a low-coherence fiber optic displacement sensor is presented. The sensor consisted of a broadband source whose central wavelength was either at 1310 nm or 1550 nm, a sensing Fabry-Pérot interferometer operating in reflective mode and an optical spectrum analyzer acting as the detection setup. All these components were connected by a single-mode fiber coupler. Metrological parameters of the sensor were...
-
Response of a fiber-optic Fabry-Pérot interferometer to refractive index and absorption changes – modelling and experiments
PublikacjaThis paper describes how the refractive index and the absorption of investigated substances change the spectrum of the optical radiation at the output of the fiber-optic Fabry-Pérot interferometer. The modeling of the operation of the interferometer takes into account not only the spectra of the refractive index and the absorption of the medium that is inside the cavity, but also spectra of the refractive indices of the core and...
-
Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.
PublikacjaIn this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...
-
Recent and Emerging Applications of Graphene-based metamaterials in Electromagnetics
PublikacjaSurface Plasmon Polaritons (SPPs) operating in mid-infrared up to terahertz (THz) frequencies have been traditionally manufactured on expensive metals such as gold, silver, etc. However, such metals have poor surface confinement that limits the optical applications of SPPs. The invention of graphene is a breakthrough in plasmon-based devices in terms of design, fabrication and applications, thanks to its plasmonic wave distribution,...
-
Low-coherence sensors with nanolayers for biomedical sensing
PublikacjaIn this paper, we describe the fiber optic low-coherence sensors using thin film. We investigated their metrological parameters. Presented sensors were made with the use of standard telecommunication single mode optical fiber (SMF28). Different materials were applied to obtain thick layers, such as boron doped diamond, silver and gold. The thickness of layers used in the experiments ranged from 100 nm to 300 nm. Measurements were...
-
Experimental Testbed of ASON/GMPLS architecture
PublikacjaThe paper presents the ASON/GMPLS architecture realized in the Department of Teleinformation Networks at Gdansk University of Technology based on the FSP 3000R7 ADVA Optical Networking platform. The FSP 3000R7 is a high-performance WDM networking system with GMPLS control plane for bidirectional transmission of optical signals. The system uses a modular structure which enables a flexible upgrade of capacity and functionality. The...
-
Application of two-dimensional intensity maps in high-accuracy polarimetry
PublikacjaWe propose the analysis of 2D intensity contour maps which is based on the optical transmission function for the polarizer-specimen-analyzer system. A small modification of the high-accuracy universal polarimeter (HAUP) technique was used to measure the intensity maps (HAUP maps) and determine the phase retardation, linear dichroism (LD) parameters, and multiple light reflection contribution in uniaxial crystals. We have performed...
-
Spectroscopic and wireless sensor of hematocrit level
PublikacjaAn optical method for hematocrit measurement has been presented. the sensor, designed and developed by authors, consists of spectroscopic set-up controlled by a microcontroller. measurement results are sent via wireless module. experiment has confirmed the ability of the sensor to determine the hematocrit with appropriate measurementaccuracy.
-
Efficiency limit of excitonic photovoltaic cells under phosphor-based white LED illumination
PublikacjaThe limit of energy conversion of excitonic photovoltaic cells working under white light illumination generated by phosphor-based LED is analysed using the modified Giebink approach. Particularly, the impact of the optical energy gap and energy loss associated with the excitons dissociation at the heterojunction interface on power conversion efficiency of the device are discussed. From the results of our study it follows that the...
-
Fractal dimension for bending–torsion fatigue fracture characterisation
PublikacjaFracture surfaces after biaxial fatigue tests were compared using fractal dimension for three types of metallic materials in smooth and notched specimens made of S355J2 and 10HNAP steels and 2017-T4 aluminium alloy, considering both proportional and nonproportional cyclic loading. High-resolution optical 3D measurement studies were performed on the entire fracture surface. A direct correlation between fractal dimension and fatigue...
-
Detection of Face Position and Orientation Using Depth Data
PublikacjaIn this paper an original approach is presented for real-time detection of user's face position and orientation based only on depth channel from a Microsoft Kinect sensor which can be used in facial analysis on scenes with poor lighting conditions where traditional algorithms based on optical channel may have failed. Thus the proposed approach can support, or even replace, algorithms based on optical channel or based on skeleton...
-
Detection of gaseous compounds with different techniques
PublikacjaSensing technology has been developed for detection of gases in some environmental, industrial, medical, and scientific applications. The main tasks of these works is to enhance performance of gas sensors taking into account their different applicability and scenarios of operation. This paper presents the descriptions, comparison and recent progress in some existing gas sensing technologies. Detailed introduction to optical sensing...
-
The morphology of V2O5 nanostructures deposited on quartz glass
Dane BadawczeThe DataSet contains the confocal microscope images of morphology evolution of vanadium pentaoxide nanostructures on quartz glass obtained by annealing as-prepared films at 500C and 600C under synthetic air.
-
Runner bean (Phaseolus coccineus) histological cross section observations of stems, leaves, and roots using light microscope
Dane BadawczeThis data set contains images of root crown, root, stem, and leaf cross-sections of runner bean (Phaseolus coccineus). Runner bean seedlings (3-5 cm) were planted on soil amended with poultry (chicken) manure biochars pyrolized at various temperatures (400, 500, and 600 C degrees). Three different poultry manure biochar materials (450, 500, and 600°C)...
-
Topography measurement methods evaluation for entire bending-fatigued fracture surfaces of specimens obtained by explosive welding
PublikacjaIn this paper, the methods of compensation of differences in the results of entire bending-fatigued fracture surface topographies were presented. The roughness evaluation was performed with a focus variation microscope and confocal surface topography measurement techniques. The differences in the ISO 25178 roughness parameters were investigated and procedures for their compensation were studied. It was found that various types...
-
Review of the Usefulness of Various Rotational Seismometers with Laboratory Results of Fibre-Optic Ones Tested for Engineering Applications
PublikacjaStarting with descriptions of rotational seismology, areas of interest and historical field measurements, the fundamental requirements for rotational seismometers for seismological and engineering application are formulated. On the above basis, a review of all existing rotational seismometers is presented with a description of the principles of their operation as well as possibilities to fulfill formulated requirements. This review...
-
Absorption spectroscopy setup for determination of whole human blood and blood–derived materials spectral characteristics
PublikacjaA dedicated absorption spectroscopy system was set up using tungsten-halogen broadband source, optical fibers, sample holder, and a commercial spectrometer with CCD array. Analysis of noise present in the setup was carried out. Data processing was applied to the absorption spectra to reduce spectral noise, and improve the quality of the spectra and to remove the baseline level. The absorption spectra were measured for whole blood...
-
Salinity enhances high optically active L-lactate production from co-fermentation of food waste and waste activated sludge: Unveiling the response of microbial community shift and functional profiling
PublikacjaLactic acid (LA), a versatile platform molecule, can be fermented from organic wastes, such as food waste and waste activated sludge. In this study, an efficient approach using salt, a component of food waste as an additive, was proposed to increase LA production. The LA productivity was increased at 10 g NaCl/L and optical pure L-lactate was obtained at 30 g NaCl/L. The enhancement of LA was in accordance with the increased solubilization...
-
In-situ monitoring of electropolymerization processes at boron-doped diamond electrodes by Mach-Zehnder interferometer
PublikacjaIn this work, the Mach-Zehnder interferometer was designed to monitor the electrochemical processes conducted at boron-doped diamond electrode surface. The diamond electrodes were synthesized via Microwave Plasma-Assisted Chemical Vapor Deposition on optical grade quartz glass. The achieved transmittance in working are of diamond electrodes reached 55 %. A cage system-based Mach-Zehnder interferometer was used which allowed the...
-
Non-invasive investigation of a submerged medieval harbour, a case study from Puck Lagoon
PublikacjaThis study presents an innovative approach to underwater archaeological prospection using non-invasive methods of seabed exploration. The research focuses on the Puck medieval harbour, a cultural heritage site, and utilises acoustic and optical underwater remote-sensing technology. The primary objectives include optimising the use of Airborne Laser Bathymetry in underwater archaeology, enhancing the filtration process for mapping...