Wyniki wyszukiwania dla: SENSOR NETWORKS
-
Sensors for Rapid Detection of Environmental Toxicity in Blood of Poisoned People
PublikacjaRecently, the diagnosis and treatment of poisoned person can be done only in specialized centers. Furthermore, currently used clinical methods of intoxication diagnosis are not sufficient for early detection. Conventional laboratory tests based on urine and blood require professional, high skilled staff, high cost equipment as well as they are arduous and lasting analytical procedures. There is a need to elaborate relatively cheap...
-
The Concept of Accuracy Analysis of the Vertical Displacements Gained from the Hydrostatic Levelling Systems’ Measurements
PublikacjaAbstract: Nowadays, hydrostatic levelling is a widely used method for the vertical displacements’ determinations of objects such as bridges, viaducts, wharfs, tunnels, high buildings, historical buildings, special engineering objects (e.g., synchrotron), sports and entertainment halls. The measurements’ sensors implemented in the hydrostatic levelling systems (HLSs) consist of the reference sensor (RS) and sensors located on the...
-
Electrochemical performance of indium-tin-oxide-coated lossy-mode resonance optical fiber sensor
PublikacjaAnalysis of liquids performed in multiple domain, e.g., optical and electrochemical (EC), has recently focus significant attention. Our previous works have shown that a simple device based on indium-tin-oxide (ITO) coated optical fiber core may be used for optical monitoring of EC processes. At satisfying optical properties and thickness of ITO a lossy-mode resonance (LMR) effect can be obtained and used for monitoring of optical...
-
Review and comparison of smoothing algorithms for one-dimensional data noise reduction
PublikacjaThe paper considers the choice of parameters of smoothing algorithms for data denoising. The impact of the window size on smoothing accuracy was analyzed. The parameters of denoising filters were selected with respect to the meansquare error between the computed linear regression and the noisy signal. Finally, we have compared mean, median, SavitzkyGolay, Kalman and Gaussian filter algorithms for the data from the digital sensor....
-
Magnetic disturbances caused by magnetic contamination of plastics
PublikacjaIn the study of low magnetic fields precision magnetometers working in a differential system are used. Two optically pumped magnetometers working in a differential system allow for precise measuring of disturbances in the magnetic field. In order to attain high accuracy of magnetic field measurement, it is necessary to use appropriate materials for the construction of a magnetometric system, particularly of those located closely...
-
Embedded system using Bluetooth Low Energy sensors for smart farming applications
PublikacjaThe main goal of this Bachelor of Engineering project titled Embedded system using Bluetooth Low Energy sensors for smart farming applications is to create a prototype of a system consistent with Agriculture 4.0 concept using Bluetooth Low Energy (BLE) technology. Developed solution shall be easy in implementation and its main functionality shall be periodic gathering of data from environmental sensors...
-
A calibration model for gas sensor array in varying environmental conditions
PublikacjaAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
Novel Complementary Multiple Concentric Split Ring Resonator for Reliable Characterization of Dielectric Substrates with High Sensitivity
PublikacjaAccurate characterization of dielectric substrates with high sensitivity remains an important challenge in a variety of industrial applications. This paper proposes an innovative strategy to address this challenge by developing and optimizing a unique Complementary Multiple Concentric Split Ring Resonator (CMC-SRR). The major goal is to propose a sensor design with increased sensitivity and reliability for dielectric characterization....
-
Processing data on sea bottom structure obtained by means of the parametric sounding
PublikacjaThe aim of the paper is to analyze data obtain during sounding of the Gdansk Bay by means of the parametric sonar. The accuracy of the sea bottom structure investigation needs the correct configuration of research equipment and the proper calibration of peripheral devices (GPS, heading sensor, motion sensor MRU-Z and navigation units) which provide necessary data to bathymetrical measurement system enabling its work with whole...
-
A calibration model for gas sensor array in varying environmental conditions
PublikacjaAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
Algoritmically improved microwave radar monitors breathing more acurrate than sensorized belt
PublikacjaThis paper describes a novel way to measure, process, analyze, and compare respiratory signals acquired by two types of devices: a wearable sensorized belt and a microwave radar-based sensor. Both devices provide breathing rate readouts. First, the background research is presented. Then, the underlying principles and working parameters of the microwave radar-based sensor, a contactless device for monitoring breathing, are described....
-
Multifunctional Bandpass Filter/Displacement Sensor Component
PublikacjaThis paper presents the design and realization of a multifunctional bandpassfilter/displacement-sensor using an edge-coupled microstrip bandpass filter loaded by a pair of split ring resonators (SRRs). It is shown that while the structure acts as a bandpass filter at its operating frequency, the phase of the reflection coefficient from a movable loading resonator at the resonance frequency of the resonator can be used for displacement...
-
Processing data on sea bottom structure obtained by means of the parametric sounding
PublikacjaThe aim of the paper is to analyze data obtained during sounding the Gdansk Bay sea bed by means of the parametric echo-sounder. The accuracy of the sea bottom structure investigation needs correct configuration of research equipment and proper calibration of peripheral devices (GPS, heading sensor, MRU-Z motion sensor and navigation instruments which provide necessary data to bathymetrical measurement system, enabling its work...
-
GRAPHENE IN GAS CHEMIRESISTORS
PublikacjaGraphene has a range of unique physical properties which could be exploited in gas sensing. Every atom of graphene may be considered as a surface atom, able to interact even with single molecule of the target gas or vapour species resulting in the ultrasensitive sensor response. In this paper the potential of graphene as a nanomaterial for fabricating chemiresistors was described. Recent development in graphene sensors was considered...
-
Usage of Two-Center Basis Function Neural Classifiers in Compact Smart Resistive Sensors
PublikacjaA new solution of the smart resistance sensorwith the Two-Center Basis Function (TCBF) neuralclassifier, for which the resistance sensor is a component ofan anti-aliasing filter of an ADC is proposed. Thetemperature measurement procedure is based on excitationof the filter by square impulses, sampling time response ofthe filter and processing measured voltage values by theTCBF classifier. All steps of the measurement procedure...
-
Multianalyte Calibration Methods for Potentiometric Integrated Sensors System for Determination of Ions Concentration in a Body Fluids
PublikacjaIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in a small sample volume. One of the key problems related to the preparation of integrated sensors systems (ISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim of the research...
-
FEEDB: A multimodal database of facial expressions and emotions
PublikacjaIn this paper a first version of a multimodal FEEDB database of facial expressions and emotions is presented. The database contains labeled RGB-D recordings of people expressing a specific set of expressions that have been recorded using Microsoft Kinect sensor. Such a database can be used for classifier training and testing in face recognition as well as in recognition of facial expressions and human emotions. Also initial experiences...
-
Uncertainty Quantification of Additive Manufacturing Post-Fabrication Tuning of Resonator-Based Microwave Sensors
PublikacjaReconfigurability, especially in terms of the ability of adjusting the operating frequency, has become an important prerequisite in the design of modern microwave components and systems. It is also pertinent to microwave sensors developed for a variety of applications such as characterization of material properties of solids or liquids. This paper discusses uncertainty quantification of additive-manufacturing-based post-fabrication...
-
A device for measuring heat flux on a rocket skin surface
PublikacjaA novel method for measuring heat flux on a surface is presented. It is an extensive upgrade of currently known heat flux sensors used mostly in civil engineering. As the thermal environment of launchers, especially sounding rocket can have an enormous negative effect on payload, careful considerations have to be taken in the process of preparing insulation. Usually, thermal data provided by the launch vehicle manufacturer is limited...
-
INVESTIGATION OF ACIDIC SOLUTIONS BY POTENTIOMETRIC TASTE SENSOR WITH ALL SOLID STATE ELECTRODES
PublikacjaPotentiometric taste sensors with electrodes containing lipophilic compound / polymer membranes were already used to distinguish commercial liquid products. In this paper a new potentiometric taste sensor consisting of six All Solid State Electrodes (ASSEs) has been presented. Each of the membrane contains a selected lipophilic compound. The set-up consists of a reference electrode and six ASSEs. The inner layer made of a conducting...
-
Optical fiber aptasensor for label-free bacteria detection in small volumes
PublikacjaHighly sensitive devices for fast bacteria detection are sought to be developed with the task of quantifying the worldwide problem of pathogenic bacteria and thus helping to take control over spreading bacterial infections. This work concerns a sensing solution based on microcavity in-line Mach-Zehnder interferometer (μIMZI) induced in an optical fiber. Such a device exhibits ultrahigh sensitivity to refractive index changes...
-
Analyzing the Impact of Simulated Multispectral Images on Water Classification Accuracy by Means of Spectral Characteristics
PublikacjaRemote sensing is widely applied in examining the parameters of the state and quality of water. Spectral characteristics of water are strictly connected with the dispersion of electromagnetic radiation by suspended matter and the absorp-tion of radiation by water and chlorophyll a and b.Multispectral sensor ALI has bands within the ranges of electromagnetic radia-tion: blue and infrared, absent in sensors such as Landsat, SPOT,...
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublikacjaAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
Evaluation of relative humidity effects on interfacial impedance at inter-coat interfaces.
PublikacjaSpektroskopia impedancyjna została zastosowana jako metoda niedestrukcyjna do oceny adhezji pomiędzy polimerowymi warstwami w ochronnym systemie powłokowym. Celem badań było stwierdzenie wpływu zewnętrznej wilgotności na impedancję międzyfazową. Badano system ochrony stosowany do ochrony samochodów. Zastosowano nowy sensor do detekcji rozwarstwienia i akumulacji wody w obszarze międzyfazy. Elektrody stanowią paski przewodzącego...
-
The concept of anti-collision system of autonomous surface vehicle
PublikacjaThe use of unmanned vehicles in various fields of science and the economy is becoming more common. An extremely important aspect of creating this type of solution is to provide autonomous vehicle navigation, which does not require interference of the human factor or in which it is limited to a minimum. This article discusses the concept of autonomous anti-collision system of unmanned surface vehicle. It proposed a sensor system...
-
Magnetic field gradient as the most useful signal for detection of flaws using MFL technique
PublikacjaThe magnetic flux leakage (MFL) technique is extensively used for detection of flaws as well as for evaluation of their dimensions in ferromagnetic materials. However, proper analysis of the MFL signal is hindered by the MFL sensor velocity causing distortions of this signal. Traditionally measured components of the MFL signal are particularly sensitive to the scanning velocity. In this paper, an another signal – the gradient of...
-
Electronic Noses and Electronic Tongues
PublikacjaChapter 7 reports the achievements on the field of artificial senses, such as electronic nose and electronic tongue. It examines multivariate data processing methods and demonstrates a promising potential for rapid routine analysis. Main attention is focused on detailed description of sensor used, construction and principle of operation of these systems. A brief review about the progress in the field of artificial senses and future trends...
-
The silver layers in fiber-optic sensors
PublikacjaIn this paper a method of application of the silver layers on the surface of an optical fiber was proposed. The optical properties and surface quality of the silver layer was examined by optical microscopy. The reflection and transmission of the sample were investigated. To evaluate the silver mirror it was placed in a fiber optic Fabry-Perot interferometer and the quality of the spectra was analyzed. The commercial mirror was...
-
Determination of the Vehicles Speed Using Acoustic Vector Sensor
PublikacjaThe method for determining the speed of vehicles using acoustic vector sensor and sound intensity measurement technique was presented in the paper. First, the theoretical basis of the proposed method was explained. Next, the details of the developed algorithm of sound intensity processing both in time domain and in frequency domain were described. Optimization process of the method was also presented. Finally, the proposed measurement...
-
Remote Monitoring System for Impedance Spectroscopy using Wireless Sensor Network
PublikacjaThe architecture of a miniaturized impedanceanalyser with wireless communication module for remoteImpedance Spectroscopy (IS) of anticorrosion coatings ondifficult-to-reach objects (e.g. on the steel construction ofthe bridge) is described in this paper. Some practical aspectsof implementation of a Wireless Sensor Network (WSN) arealso discussed. A low scale, middle range, WSN networkcomposed of a Base Station (BS) with a Personal...
-
Fluctuation-Enhanced Sensing with Organically Functionalized Gold Nanoparticle Gas Sensors Targeting Biomedical Applications
PublikacjaDetection of volatile organic compounds is a useful approach to non-invasive diagnosis of diseases through breath analysis. Our experimental study presents a newly developed prototype gas sensor, based on organically-functionalized gold nanoparticles, and results on formaldehyde detection using fluctuation-enhanced gas sensing. Formaldehyde was easily detected via intense fluctuations of the gas sensor’s resistance, while the cross-influence...
-
Application of fiber optic sensors using Machine Learning algorithms for temperature measurement of lithium-ion batteries
PublikacjaOptical fiber sensorsusing low-coherence interferometry require processing ofthe output spectrum or interferogramto quickly and accurately determine the instantaneous value of the measured quantity, such as temperature.Methods based on machine learning are a good candidate for this application. The application of four such methods in an optical fiber temperature sensoris demonstrated.Using aZnO-coated...
-
MONTE CARLO MODELING OF OPTICAL SENSOR FOR POST-OPERATIVE FREE FLAP MONITORING
PublikacjaAfter a preliminary study of the currently employed methods in vitality monitoring of the tissue flaps (TRAM, DIEP, SIEA), a usefulness of optical techniques is discussed. It seems that one of the most promising in monitoring tissue flaps blood flow is a near infrared spectrometry (NIRS). However, a special design of a measurement sensor has to be developed. First, basing on the literature study an optical “window” is characterized....
-
Nitrogen dioxide sensing properties of PEDOT polymer films
PublikacjaThis work presents a simple and fully electrochemical route for the polymerization of poly(3,4-ethylenedioxytiophene) (PEDOT) films for fabricating a NO2 gas sensor prepared by electropolymerization of 3,4-Ethylenedioxythiophene (EDOT) monomer in lithium perchlorate/acetonitrile solution. The main aim of this study is to determine the sensing properties of conductive polymer at elevated temperatures. The effects of the humidity,...
-
Scalable Measurement System for Multiple Impedance Gas Sensors
PublikacjaAuthor proposes scalable architecture of the measurement system for gas sensor with impedance dependance of the gas concentration. The main part of the system is a single-board impedance analyser. The number of analysers working in parallel can be configured according to specific application. The system is controlled by a single computer which organises the measurement cycle and store the acquired measurement data. The system is...
-
Hardware-Software Implementation of a Sensor Network for CityTraffic Monitoring Using the FPGA- and ASIC-Based Sensor Nodes
PublikacjaArtykuł opisuje prototypową sieć sensorową do monitorowania ruchu pojazdów w mieście. Węzły sieci sensorowej, wyposażone w kamerę o niskiej rozdzielczości, obserwują ulice i wykrywają poruszające się obiekty. Detekcja obiektów jest realizowana w oparciu o własny algorytm segmentacji obrazów, wykorzystujący podwójne odejmowanie tła, wykrywanie krawędzi i cieni, działający na dedykowanym systemie mikroelektronicznym typu ''System...
-
Creating Dynamic Maps of Noise Threat Using PL-Grid Infrastructure
PublikacjaThe paper presents functionality and operation results of a system for creating dynamic maps of acoustic noise employing the PL-Grid infrastructure extended with a distributed sensor network. The work presented provides a demonstration of the services being prepared within the PLGrid Plus project for measuring, modeling and rendering data related to noise level distribution in city agglomerations. Specific computational environments,...
-
Advanced Sensor for Non-Invasive Breast Cancer and Brain Cancer Diagnosis Using Antenna Array with Metamaterial-Based AMC
PublikacjaMicrowave imaging techniques can identify abnormal cells in early development stages. This study introduces a microstrip patch antenna coupled with artificial magnetic conductor (AMC) to realize improved sensor for non-invasive (early-stage) breast cancer and brain cancer diagnosis. The frequency selectivity of the proposed antenna has been increased by the presence of AMC by creating an additional resonance at 2.276 GHz associated...
-
Magnetic field microsensor based on GaAs MESFET
PublikacjaA novel concept of the drain separation design in a horizontally-split-drain GaAs MAGFET sensor, based on epitaxial layer growth, was developed. Proper choice of GaAs/AlAs/GaAs epitaxial layer sequence provided good electrical isolation between the drain regions. The measured leakage current between the drain regions was in the range of nA for up to 2V drain voltage bias difference. Performed analytical and numerical calculations...
-
Badania nad potencjometrycznymi sensorami smaku
PublikacjaPrzedstwiono badania nad 5-kanałowym sensorem smaku kwasnego, zbudowanym z elektrod z membranami polimerowo - lipidowymi zawierającymi odpowiednie lipidy. Stwierdzono, że sensor ten jest bardzo czuły na zmainy stężenia kwasu cytrynowego, natomiast wykazuje nieco gorszą czułosc na obecnosć kwasu octowego. Stwirdzono dobrą trwałosć membran oraz powtarzalnośc otrzymanych wyników. Wydaje się, że badane układy mogą byc wykorzystane...
-
Monitoring of single-side lap grinding with electroplated tools
PublikacjaThe results presented in the paper show that utilising microphones as audible sound sensors is a suitable approach for monitoring a single-side lap grinding process due to the low levels of noise generated by the drives of a machine tool. The results confirm that sound signal analysis is a feasible and relatively simple method to monitor a lap grinding process with the use of an audible sound sensor. Proposed method can be used...
-
Wybrane aspekty oceny jakości produktów żywnościowych
PublikacjaPrzedstawiono wybrane aspekty oceny jakości produk tów żywnościo- wych: pojęcie jakości, wybrane metody oceny jakości ze szczególnym uwzględ- nieniem sztucznych potencjometrycznych sensorów sma ku składających się z szeregu elektrod typu ISE (Ion Selective Electrodes ) oraz ASSE (All Solid State Electrodes). Omówiono działanie sztucznych sensorów smaku. Przedstawiono 10 potencjometryczny sensor wprowadzony do obrotu hand lowego....
-
Tuning transfer function of fiber-optic Fabry-Pérot interferometer via introduction of birefringence in the cavity
PublikacjaThe study investigates the impact of birefringence exhibited by the cavity material of a fiber-optic Fabry-Pérot interferometer on its transfer function. The theoretical approach to analyze the effect of birefringence in the cavity of a plane Fabry-Pérot interferometer is described. The case of high- and low-finesse interferometer is investigated. It is shown that introduction of a birefringent medium of optimized parameters can...
-
The influence of small amount of substances present in tissue on the optical spectrum of immunosuppressive drug
PublikacjaIn this paper, we describe how commonly present in tissue substances - sodium chloride and glucose - affect the optical spectrum of an immunosuppressive drug (Cyclaid® by Apotex). Prepared samples were investigated using the spectrophotometer in the spectrum range from 250 nm to 1100 nm. The maximum wavelength shift calculated on the basis of measurement results is not bigger than the measurement wavelength step. So, it can be...
-
Electrochemically directed biofunctionalization of a lossy-mode resonance optical fiber sensor
PublikacjaIn this work, we present a direct electrochemical biofunctionalization of an indium-tin-oxide-coated lossy-mode resonance optical fiber sensor. The functionalization using a biotin derivative was performed by cyclic voltammetry in a 10 mM biotin hydrazide solution. All stages of the experiment were simultaneously verified with optical and electrochemical techniques. Performed measurements indicate the presence of a poly-biotin...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublikacjaFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Post processing and selecting data obtain with parametric sub-bottom profiler SES-2000 Standard during sounding the Gulf of Gdansk
PublikacjaThe main goal of the paper is to describe the results of sounding the Gulf of Gdansk seabed using a parametric sub-bottom profiler SES-2000 Standard. Quality of obtained during trials data depends inter alia on proper location of antenna to reduce influence of pitch, roll, heave and ship noise (bubbles from propeller and a hull flow, vibration from main engine and peripheral devices). Furthermore calibration of complementary units...
-
A method to monitor urinary carbon dioxide in patients with septic shock
PublikacjaSevere sepsis and septic shock are life-threatening conditions with mortality rates exceeding 31% (Levy et al., 2012) [1]. Septicemia was the most expensive US hospital condition in 2011 (Torio and Andrews, 2006)[2]. Urinary carbon dioxide may provide rapid, clinically useful information about a patient’s status, empowering physicians to intervene earlier and improve septic shock mortality. The objective of this paper is to validate...
-
Cost-Efficient Measurement Platform and Machine-Learning-Based Sensor Calibration for Precise NO2 Pollution Monitoring
PublikacjaAir quality significantly impacts human health, the environment, and the economy. Precise real-time monitoring of air pollution is crucial for managing associated risks and developing appropriate short- and long-term measures. Nitrogen dioxide (NO2) stands as a common pollutant, with elevated levels posing risks to the human respiratory tract, exacerbating respiratory infections and asthma, and potentially leading to chronic lung...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublikacjaFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...