Wyniki wyszukiwania dla: DIELECTRIC MEASUREMENT, PLANAR MICROWAVE SENSOR, NEAR FIELD COUPLING, WIRELESS SENSOR
-
Label‐free optical detection of cyclosporine in biological fluids
PublikacjaIn this paper, a spectroscopic method for determination of cyclosporine concentrations in biological fluids is presented. Blood plasma and hemoglobin solutions are chosen for the experiment. For various cyclosporine concentrations in blood plasma and hemoglobin, absorbance measurements in spectra range from 600 to 1100 nm are performed. The measurement results are analyzed by the use of a dedicated algorithm. The obtained data...
-
Methodology for the Correction of the Spatial Orientation Angles of the Unmanned Aerial Vehicle Using Real Time GNSS, a Shoreline Image and an Electronic Navigational Chart
PublikacjaUndoubtedly, Low-Altitude Unmanned Aerial Vehicles (UAVs) are becoming more common in marine applications. Equipped with a Global Navigation Satellite System (GNSS) Real-Time Kinematic (RTK) receiver for highly accurate positioning, they perform camera and Light Detection and Ranging (LiDAR) measurements. Unfortunately, these measurements may still be subject to large errors-mainly due to the inaccuracy of measurement of the optical...
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 194
Dane BadawczeThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 194, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 192
Dane BadawczeThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 192, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 191
Dane BadawczeThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 191, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 193
Dane BadawczeThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 193, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 190
Dane BadawczeThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 190, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Propagation Characteristics of Partial Discharges in an Oil-Filled Power Transformer
PublikacjaPower transformers are among the most important assets in the power transmission and distribution grid. However, they suffer from degradation and possible faults causing major electrical and financial losses. Partial discharges (PDs) are used to identify the insulation health status and their degradation level. PDs are incipient, low-magnitude faults caused by localized dielectric breakdown. Those activities emit signals in many...
-
ESPAR Antenna-Based WSN Node With DoA Estimation Capability
PublikacjaIn this paper, we present a low-cost energy-efficient electronically steerable parasitic array radiator (ESPAR) antenna-based wireless sensor network (WSN) node designed for IEEE 802.15.4 standard that is capable of performing direction of arrival (DoA) estimation in real-life outdoor environments. To this end, we propose the WSN node architecture, design and realization that utilizes NXP JN5168 radio frequency (RF) wireless transceiver...
-
Optimization of a Fabry-Perot Sensing Interferometer design for an optical fiber sensor of hematocrit level
PublikacjaContinuous measurement of the hemato crit level in blo o d can p otentially b e p erformed using optical bre sensors. The FabryPerot interferometric sensors are a promising candidate in this application. The most imp ortant step in the design of the sensor is design of the sensing interferometer. Adequate cavity length and high interference contrast are two most imp ortant requirements in this application. The design metho d of...
-
RSS-Based DoA Estimation Using ESPAR Antenna Radiation Patterns Spline Interpolation
PublikacjaIn this paper, it is shown how power pattern crosscorrelation (PPCC) algorithm, which relies on received signal strength (RSS) values recorded at electronically steerable parasitic array radiator (ESPAR) antenna output port, used for direction-of-arrival (DoA) estimation, can easily be improved by applying spline interpolation to radiation patterns recorded in the calibration phase of the DoA estimation process. The proposed method...
-
RSS-based DoA Estimation Using ESPAR Antennas and Interpolated Radiation Patterns
PublikacjaIn this letter, it is shown how an algorithm, which employs received signal strength (RSS) values in order to estimate direction-of-arrival (DoA) of impinging signals in wireless sensor network (WSN) nodes equipped with electronically steerable parasitic array radiator (ESPAR) antennas, can easily be improved by applying an interpolation algorithm to radiation patterns recorded in the calibration phase of the DoA estimation process....
-
The low-frequency magnetic field emissions on-board of the vessel
Dane BadawczeThe data represents measurement results performed on board of the vessel. The acquired time-waveforms, corresponding to the instantaneous values of the magnetic field (MF) induction were acquired near the cable supplying the bow thruster motor. Data recording of the magnetic field density (MFD) emissions was carried out with a/d converters of the data...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Influence of sensor design and optical properties of tissue on the photoplethysmographic signal
PublikacjaPhotopletysmography and an associated technique called pulse oximetry are still explored due to the expectations that they give a lot of information about the state of the patient and, also, due to the fact that they are non invasive. Knowledge about the impact of various parameters on the measured signal leads to a faster and a more reliable way of analyzing measurement results and finding the dependencies between the involved...
-
Corrosion monitoring by harmonic analysis in aqueous environments
PublikacjaThis paper presents tests concerning the rate of corrosion in non-alloy steel (type S235JR) in an aqueous environment, with an additive of sodium chloride by means of polarization resistance measurements and harmonic analysis. The tests have been carried out for steel samples exposed to the testing environment for six weeks, in order to obtain a constant rate of corrosion in the function of time. The measurements have aimed at...
-
Optimal ECG lead for deriving respiratory signal
PublikacjaEDR is an interesting measuring technique that allows an indirect assessment of respiratory activity. This is an alternative solution to direct methods that are based on the measurement of air flow, which require a specialized sensor or even a system. However, due to inter-personal anatomical differences, the optimal ECG lead (placement of the electrodes) ensuring the best EDR signal quality is not fixed. An influence of ECG lead...
-
A method to monitor urinary carbon dioxide in patients with septic shock
PublikacjaSevere sepsis and septic shock are life-threatening conditions with mortality rates exceeding 31% (Levy et al., 2012) [1]. Septicemia was the most expensive US hospital condition in 2011 (Torio and Andrews, 2006)[2]. Urinary carbon dioxide may provide rapid, clinically useful information about a patient’s status, empowering physicians to intervene earlier and improve septic shock mortality. The objective of this paper is to validate...
-
Post processing and selecting data obtain with parametric sub-bottom profiler SES-2000 Standard during sounding the Gulf of Gdansk
PublikacjaThe main goal of the paper is to describe the results of sounding the Gulf of Gdansk seabed using a parametric sub-bottom profiler SES-2000 Standard. Quality of obtained during trials data depends inter alia on proper location of antenna to reduce influence of pitch, roll, heave and ship noise (bubbles from propeller and a hull flow, vibration from main engine and peripheral devices). Furthermore calibration of complementary units...
-
A device for measuring heat flux on a rocket skin surface
PublikacjaA novel method for measuring heat flux on a surface is presented. It is an extensive upgrade of currently known heat flux sensors used mostly in civil engineering. As the thermal environment of launchers, especially sounding rocket can have an enormous negative effect on payload, careful considerations have to be taken in the process of preparing insulation. Usually, thermal data provided by the launch vehicle manufacturer is limited...
-
Collision‐Aware Routing Using Multi‐Objective Seagull Optimization Algorithm for WSN‐Based IoT
PublikacjaIn recent trends, wireless sensor networks (WSNs) have become popular because of their cost, simple structure, reliability, and developments in the communication field. The Internet of Things (IoT) refers to the interconnection of everyday objects and sharing of information through the Internet. Congestion in networks leads to transmission delays and packet loss and causes wastage of time and energy on recovery. The routing protocols...
-
Portable raman spectrometer for maritime security applications
PublikacjaThe fast identification of explosives, narcotics and other chemicals carried on board of ships or transported in containers to the harbors is an important problem of maritime security. Raman spectroscopy is widely used for fast identification of various chemicals. Continuous progress in the field of photonics has resulted in commercial availability of low-power compact Raman spectrometers which can be integrated into portable systems....
-
Open smart glasses development platform for AAL applications
PublikacjaThis paper describes an open platform for multi sensory electronic glasses that supports new and enhanced methods for intelligent interaction with patients, with smart objects, or to be used as new data input modalities like proximity sensor or smart textile interfaces. All the activities have been developed, investigated and evaluated within EU CHIST-ERA eGlasses project...
-
A Novel IoT-Perceptive Human Activity Recognition (HAR) Approach Using Multi-Head Convolutional Attention
PublikacjaTogether with fast advancement of the Internet of Things (IoT), smart healthcare applications and systems are equipped with increasingly more wearable sensors and mobile devices. These sensors are used not only to collect data, but also, and more importantly, to assist in daily activity tracking and analyzing of their users. Various human activity recognition (HAR) approaches are used to enhance such tracking. Most of the existing...
-
Direction-of-Arrival Estimation Using an ESPAR Antenna with Simplified Beam Steering
PublikacjaIn this paper, it has been shown, how electronically steerable parasitic array radiator (ESPAR) antenna, in which beam steering is done in a simple way, can be used for directionof- arrival (DoA) estimation of an unknown signal impinging the antenna. The concept is based on an ESPAR antenna having twelve parasitic elements, in which beam switching is realized by RF switches providing required loads to its parasitic elements. Numerical...
-
Determination of the ratio resistors in the input circuits of the NTC10k thermistor calibration system
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Simulation of signal acquisition from a rotary flowmeter
Dane BadawczeThe dataset contains results of simulation measuring the flow of homogeneous substances by rotational flow meter: a moment of impulse at the output of flow meter, time between successive pulses, number of pulses counted from standard generator and relative error of measurement.
-
Upper Limb Bionic Orthoses: General Overview and Forecasting Changes
PublikacjaUsing robotics in modern medicine is slowly becoming a common practice. However, there are still important life science fields which are currently devoid of such advanced technology. A noteworthy example of a life sciences field which would benefit from process automation and advanced robotic technology is rehabilitation of the upper limb with the use of an orthosis. Here, we present the state-of-the-art and prospects for development...
-
HCI-Based Wireless System for Measuring the Concentration of Mining Machinery and Equipment Operators
PublikacjaMaintaining stable and reliable working conditions is a matter of vital importance for various companies, especially those involving heavy machinery. Due to human exhaustion, as well as unpredicted hazards and dangerous situations, the personnel has to take actions and wisely plan each move. This paper presents a human–computer interaction (HCI)-based system that uses a concentration level measurement function to increase the safety...
-
Discrete-time estimation of nonlinear continuous-time stochastic systems
PublikacjaIn this paper we consider the problem of state estimation of a dynamic system whose evolution is described by a nonlinear continuous-time stochastic model. We also assume that the system is observed by a sensor in discrete-time moments. To perform state estimation using uncertain discrete-time data, the system model needs to be discretized. We compare two methods of discretization. The first method uses the classical forward Euler...
-
Evaluating the position of a mobile robot using accelerometer data
PublikacjaThis paper analyses the problem of determining the position of a robot using an accelerometer, which is an essential part of inertial measurement units (IMU). The information gained from such a gauge, however, requires double integration of sensor data. To assure an expected effect, a mathematical model of a low-cost accelerometer of the MEMS type is derived. Moreover, in order to improve the performance of positioning based on...
-
Stochastic resonance in measurements
PublikacjaNoise is usually associated with the negative phenomenon, hampering the measurements data and their analysis. This view has been broken in the '80s when the phenomenon of stochastic resonance (Stochastic Resonance - SR) was discovered. It is a phenomenon that occurs in nonlinear dynamic measurement systems when the selected input noise can optimize system performance. SR became a way to improve efficiency of weak signals detection....
-
Discrete-time estimation of nonlinear continuous-time stochastic systems
PublikacjaIn this paper we consider the problem of state estimation of a dynamic system whose evolution is described by a nonlinear continuous-time stochastic model. We also assume that the system is observed by a sensor in discrete-time moments. To perform state estimation using uncertain discrete-time data, the system model needs to be discretized. We compare two methods of discretization. The first method uses the classical forward Euler...
-
Evaluating the mobile robot positions using accelerometer data
PublikacjaThis paper analyzes the problem of determining the position of a robot using an accelerometer, which is an essential part of inertial measurement units (IMU). The information gained from such a gauge, however, requires double integration of sensor data. To assure an expected effect, a mathematical model of a low-cost accelerometer of the MEMS type is derived. Moreover, in order to improve the performance of positioning based on...
-
Road surface roughness estimation employing integrated position and acceleration sensor
PublikacjaAssessment of a surface quality being an essential task for the authorities supervising the roads provides the subject of the paper. Information about riding quality of a pavement, important for drivers, both in terms of their comfort and safety is collected during experiments employing mobile sensors. The paper describes the use of a miniature position and acceleration sensor for evaluation of the roughness of the road surface....
-
Superconductivity in the Cu(Ir1-xPtx)2Se4 spinel
PublikacjaWe report the observation of superconductivity in the CuIr2Se4 spinel induced by partial substitution of Pt for Ir. The optimal doping level for superconductivity in Cu(Ir1-xPtx )2Se4 is x = 0.2, where Tc is 1.76 K. A superconducting Tc vs composition dome is established between the metallic, normal conductor CuIr2Se4 and semiconducting CuIrPtSe4. Electronic structure calculations show that the optimal Tc occurs near the electron count...
-
Methods of data extraction from sub-bottom profiler's signal
PublikacjaData obtain during sounding Gdansk Bay with SES-2000 Standard parametric sub-bottom profiler has two types of information: envelope and pure signal. First is used to plot echograms in real time and contain envelope of echo. The second one is stored during sounding and can be processed after recording data. Comparison of results will be shown and discussed. First step in investigation was proper configuration of small measurement...
-
Trust-Based Model for the Assessment of the Uncertainty of Measurements in Hybrid IoT Networks
PublikacjaThe aim of this paper is to introduce a NUT model (NUT: network-uncertainty-trust) that aids the decrease of the uncertainty of measurements in autonomous hybrid Internet of Things sensor networks. The problem of uncertainty in such networks is a consequence of various operating conditions and varied quality of measurement nodes, making statistical approach less successful. This paper presents a model for decreasing the uncertainty...
-
Photonic sensor to detect rapid changes in CRP levels
PublikacjaOne of the most important biomarkers used to determine inflammation is C-reactive protein (CRP). Its level, when it is within the range that does not define inflammation, informs about the risk of cardiovascular events. If the norm is exceeded and inflammation is detected in the body, CRP level can increase 1000 times within a few hours. The type of infection can also be determined based on the level of elevated CRP. All this makes...
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
PublikacjaThis paper presents an implementation of the monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in a utility water installation using an automated corrosion monitoring system. Due to the fact that the corrosion inhibitor was added to water intended for human consumption, it was necessary to build a multi-sensor monitoring system. In order to implement corrosion monitoring using a linear...
-
Autonomous Control of the Underwater Remotely Operated Vehicle in Collision Situation with Stationary Obstacle
PublikacjaThe article considers the problem of autonomous control of the underwater remotely operated vehicle mini Remotely Operated Vehicle (ROV) in a collision situation with a stationary obstacle. The control of the collision avoidance process is presented as a synthesis of fuzzy proportional-differential controllers for the control of distance and orientation concerning the detected stationary obstacle. The control of the submergence...
-
Inertial Sensors Applications in Underwater Measurements
PublikacjaOver the past decades microelectromechanical systems (MEMS) researchers have demonstrated a number of microsensors for almost every possible sensing modality, including attitudes. Current MEMS inertial measurement units (IMU) come in many shapes, sizes, and costs — depending on the application, and performance required. MEMS sensors have proved and demonstrated performance exceeding those of their macroscale counterpart sensors. In...
-
Overview of Metamaterials-Integrated Antennas for Beam Manipulation Applications: The Two Decades of Progress
PublikacjaMetamaterials (MMs) are synthetic composite structures with superior properties not found in naturally occurring materials. MMs have gained massive attention over the last two decades because of their extraordinary properties, such as negative permittivity and permeability. These materials enable many applications in communication subsystems, especially in the field of antenna design, to enhance gain, bandwidth, and efficiency,...
-
Cost-Efficient Globalized Parameter Optimization of Microwave Components through Response-Feature Surrogates and Nature-Inspired Metaheuristics
PublikacjaDesign of contemporary microwave devices predominantly utilizes computational models, including both circuit simulators, and full-wave electromagnetic (EM) evaluation. The latter constitutes the sole generic way of rendering accurate assessment of the system outputs that considers phenomena such as cross-coupling or radiation and dielectric losses. Consequently, for reliability reasons, the final tuning of microwave device parameters...
-
DST-Based Detection of Non-cooperative Forwarding Behavior of MANET and WSN Nodes
Publikacja. Selfish node behavior can diminish the reliability of a mobile ad hoc network (MANET) or a wireless sensor network (WSN). Efficient detection of such behavior is therefore essential. One approach is to construct a reputation scheme, which has network nodes determine and share reputation values associated with each node; these values can next be used as input to a routing algorithm to avoid end-to-end routes containing ill-reputed...
-
Low-Profile ESPAR Antenna for RSS-Based DoA Estimation in IoT Applications
PublikacjaIn this paper, we have introduced a low-profile electronically steerable parasitic array radiator (ESPAR) antenna that can successfully be used to estimate the direction-of-arrival (DoA) of incoming signals in wireless sensor network (WSN) applications, in which the height of the complete antenna has to be low. The proposed antenna is over three times lower than high-profile ESPAR antenna designs currently available in the literature...
-
Application of boron-doped diamond film and ZnO layer in the Fabry-Pérot interferometer
PublikacjaIn this article there have been presented the use of boron-doped diamond films for sensor applications. The low-finesse Fabry-Pérot interferometer working in the reflective mode has been implemented. Two kinds of reflective layers have been elaborated: boron-doped diamond thin films and zinc-oxide (ZnO) layer. Thin ZnO layers were deposited by Atomic Layer Deposition (ALD) on the face of a standard telecommunication single-mode...
-
A novel hierarchically-porous diamondized polyacrylonitrile sponge-like electrodes for acetaminophen electrochemical detection
PublikacjaA novel composite electrode material consisting of tangled fibrous polyacrylonitrile-based hierarchically-struc- tured nanocomposites has been produced by wet-spinning, carbonized and decorated with a carbon nano- architecture by microwave plasma-enhanced chemical vapor deposition and investigated as a metal-free electrode for the enhanced electrochemical detection of acetaminophen. Surprisingly, the hierarchical fiber ar- chitecture...
-
Determination of Odour Interactions in Gaseous Mixtures Using Electronic Nose Methods with Artificial Neural Networks
PublikacjaThis paper presents application of an electronic nose prototype comprised of eight sensors, five TGS-type sensors, two electrochemical sensors and one PID-type sensor, to identify odour interaction phenomenon in two-, three-, four- and five-component odorous mixtures. Typical chemical compounds, such as toluene, acetone, triethylamine, α-pinene and n-butanol, present near municipal landfills and sewage treatment plants were subjected...