Wyniki wyszukiwania dla: CORROSION IN SIMULATED BODY FLUID
-
A Probe into the Corrosion Behavior of a WE43B Magnesium Alloy in a Simulated Body Fluid using Dynamic Electrochemical Impedance Spectroscopy
PublikacjaWE43B is one of the newest Mg alloys with practical application in biomedical implant technology. This work attempts to scrutinize the corrosion characteristics of WE43B alloy in a simulated body fluid (SBF) at a typical body temperature. The dynamic-electrochemical impedance spectroscopy with the capacity to track changes on surfaces in a dynamic corrosive system is used in combination with other classical techniques namely, linear...
-
Effects of solution composition and electrophoretic deposition voltage on various properties of nanohydroxyapatite coatings on the Ti13Zr13Nb alloy
PublikacjaThe purpose of the research was to establish the influence of the solution composition and the electrophoretic deposition voltage on the coating homogeneity and thickness, nanohardness, adhesion, corrosion resistance and wettability. The Ti13Zr13Nb alloy was coated by the electrophoretic technique with hydroxyapatite in a solution containing 0.1, 0.2 or 0.5 g nanoHAp in 100 mL of suspension and at voltage 15, 30 or 50 V. The scanning...
-
Antibacterial properties of laser-encapsulated titanium oxide nanotubes decorated with nanosilver and covered with chitosan/Eudragit polymers
PublikacjaTo provide antibacterial properties, the titanium samples were subjected to electrochemical oxidation in the fluoride-containing diethylene glycol-based electrolyte to create a titanium oxide nanotubular surface. Afterward, the surface was covered by sputtering with silver 5 nm film, and the tops of the nanotubes were capped using laser treatment, resulting in an appearance of silver nanoparticles (AgNPs) of around 30 nm in diameter...
-
The Chemical and Biological Properties of Nanohydroxyapatite Coatings with Antibacterial Nanometals, Obtained in the Electrophoretic Process on the Ti13Zr13Nb Alloy
PublikacjaThe risk of an early inflammation after implantation surgery of titanium implants has caused the development of different antimicrobial measures. The present research is aimed at characterizing the effects of nanosilver and nanocopper dispersed in the nanohydroxyapatite coatings, deposited on the Ti13Zr13Nb alloy, and on the chemical and biological properties of the coatings.The one-stage deposition process was performed by the...
-
Corrosion Resistance and Surface Bioactivity of Ti6Al4V Alloy after Finish Turning under Ecological Cutting Conditions
PublikacjaThe influence of cooling conditions and surface topography after finish turning of Ti6Al4V titanium alloy on corrosion resistance and surface bioactivity was analyzed. The samples were machined under dry and minimum quantity lubrication (MQL) conditions to obtain different surface roughness. The surface topographies of the processed samples were assessed and measured using an optical profilometer. The produced samples were subjected...
-
The Effect of Sodium Tetrafluoroborate on the Properties of Conversion Coatings Formed on the AZ91D Magnesium Alloy by Plasma Electrolytic Oxidation
PublikacjaMagnesium and its alloys are widely used in many areas because of their light weight, excellent dimensional stability, and high strength-to-weight ratio. However, the material exhibits poor wear and corrosion resistance, which limits its use. Plasma electrolytic oxidation (PEO) is an effective surface modification method for producing ceramic oxide layers on Mg and their alloys. The influence of the additions of sodium tetrafluoroborate...
-
Properties of Nanohydroxyapatite Coatings Doped with Nanocopper, Obtained by Electrophoretic Deposition on Ti13Zr13Nb Alloy
PublikacjaNowadays, hydroxyapatite coatings are the most common surface modification of long-term implants. These coatings are characterized by high thickness and poor adhesion to the metallic substrate. The present research is aimed at characterizing the properties of nanohydroxyapatite (nanoHAp) with the addition of copper nanoparticle (nanoCu) coatings deposited on the Ti13Zr13Nb alloy by an electrophoresis process. The deposition of...
-
Corrosion resistance examinations of Ti6Al4V alloy with the use of potentiodynamic method in Ringer`s and artificial saliva solutions
PublikacjaThe research results of corrosion resistance of the Ti6Al4V alloy in the simulated body fluids (SBF) are presented. The polished specimens have shown better corrosion resistance than grinded surfaces in both liquids. The artificial saliva has revealed more aggressive test solution than Ringer`s solution. The pitting tendency has been observed in Ringer`s solution for grinded specimens.
-
Electrophoretic Deposition and Characteristics of Chitosan–Nanosilver Composite Coatings on a Nanotubular TiO2 Layer
PublikacjaThe surface treatment of titanium implants has been applied mainly to increase surface bioactivity and, more recently, to introduce antibacterial properties. To this end, composite coatings have been investigated, particularly those based on hydroxyapatite. The present research was aimed at the development of another coating type, chitosan–nanosilver, deposited on a Ti13Zr13Nb alloy. The research comprised characterization of the...
-
THE POSSIBILITY OF USE OF LASER-MODIFIED Ti6Al4V ALLOY IN FRICTION PAIRS IN ENDOPROSTHESES
PublikacjaThe purpose of this paper is to show results of laser treatment at cryogenic conditions of the Ti6Al4V alloy used for orthopedic applications. That modification process ought to bring beneficial changes of microstructure and residual stresses in the surface layer. The paper presents the abrasive wear of the base and laser remelted material in association with ceramics Al2O3. Despite the surface cracking after laser treatment the...
-
Influence of Surface Modification of Titanium and Its Alloys for Medical Implants on Their Corrosion Behavior
PublikacjaTitanium and its alloys are often used for long-term implants after their surface treatment. Such surface modification is usually performed to improve biological properties but seldom to increase corrosion resistance. This paper presents research results performed on such metallic materials modified by a variety of techniques: direct voltage anodic oxidation in the presence of fluorides, micro-arc oxidation (MAO), pulse laser treatment,...
-
In Vitro Dissolution of Na-Ca-P-Oxynitrides
Publikacja: Sodium-calcium-phosphate based oxynitride glasses and glass-ceramics doped with Mg, Si, and Nb were studied in vitro in simulated body fluid (SBF) under static conditions. The release of ions and pH changes up to 7 days of immersion were investigated. The nitrogen incorporation into phosphate glass matrix was found to notably influence in vitro dissolution only of homogenous glasses. Increasing the nitrogen content in the samples...
-
Structural changes of bacterial cellulose due to incubation in conditions simulating human plasma in the presence of selected pathogens
PublikacjaBacterial nanocellulose (BNC) is a natural biomaterial with a wide range of medical applications. However, it cannot be used as a biological implant of the circulatory system without checking whether it is biodegradable under human plasma conditions. This work aimed to investigate the BNC biodegradation by selected pathogens under conditions simulating human plasma. The BNC was incubated in simulated biological fluids with or...
-
Effects of Laser Remelting at Cryogenic Conditions on Microstructure and Wear Resistance of the Ti6Al4V Alloy Applied in Medicine
PublikacjaThe titanium and its alloys can be subjected to surface treatment, including laser treatment. In this work a new laser treatment at cryogenic conditions of Ti6Al4V alloy has been described. The work has been aimed at establishing whether such surface treatment could be suitable for implants working under wear in biological corrosive environment. The remelting has been made with the use of CO2 continuous work laser at laser power...
-
Intelligent microbearing project with memory of stress-strain history
PublikacjaTaking into account the increasing need of intelligent micro-bearing with memory, this paper presents the optimization, simulation and practical application of operating parameters(load carrying capacity, friction forces, friction coefficient, wear), simulation for hydrodynamic HDD micro-bearing with curvilinear nano-grooved journal profile. One of the reason of such journal profile is that this journal profile contributes to the...
-
Properties of New Composite Materials Based on Hydroxyapatite Ceramic and Cross-Linked Gelatin for Biomedical Applications
PublikacjaThe main aim of the research was to develop a new biocompatible and injectable composite with the potential for application as a bone-to-implant bonding material or as a bone substitute. A composite based on hydroxyapatite, gelatin, and two various types of commercially available transglutaminase (TgBDF/TgSNF), as a cross-linking agent, was proposed. To evaluate the impacts of composite content and processing parameters on various...
-
Sodium nitrite as a corrosion inhibitor of copper in simulated cooling water
PublikacjaThe corrosion inhibition behavior of sodium nitrite (NaNO2) towards pure copper (99.95%) in simulated cooling water (SCW) was investigated by means of electrochemical impedance spectroscopy (EIS) and dynamic electrochemical impedance spectroscopy (DEIS). NaNO2 interferes with metal dissolution and reduce the corrosion rate through the formation or maintenance of inhibitive film on the metal surface. Surface morphologies illustrated...
-
Investigation of corrosion behavior of 6060 and 6082 aluminum alloys under simulated acid rain conditions
PublikacjaInstantaneous impedance changes of 6060 and 6082 type aluminum alloys in pure water, and simulated acid rain poured into the pure water was investigated by dynamic electrochemical impedance spectroscopy (DEIS). In this way, the influence of aluminum content on the corrosion behavior of 6060 and 6082 type aluminum alloys immersed in simulated acid rain was determined. The corrosion rate of the alloy decreased with increasing Al...
-
Processing of Polyester-Urethane Filament and Characterization of FFF 3D Printed Elastic Porous Structures with Potential in Cancellous Bone Tissue Engineering
PublikacjaThis paper addresses the potential of self-made polyester-urethane filament as a candidate for Fused Filament Fabrication (FFF)-based 3D printing (3DP) in medical applications. Since the industry does not provide many ready-made solutions of medical-grade polyurethane filaments, we undertook research aimed at presenting the process of thermoplastic polyurethane (TPU) filament formation, detailed characteristics, and 3DP of specially...
-
A comprehensive evaluation of flexible FDM/FFF 3D printing filament as a potential material in medical application
PublikacjaThe use of FDM/FFF in 3D printing for medical sciences is becoming common. This is due to the high availability and decent price of both 3D printers and filaments useful for FDM/FFF. Currently, researchers' attention is focused mainly on the study of medical filaments based on PLA, PCL or their modifications. This contributes to insufficient diversity of medical-grade filaments on the market. Moreover, due to the lack of specified...
-
Vident-synth: a synthetic intra-oral video dataset for optical flow estimation
Dane BadawczeWe introduce Vident-synth, a large dataset of synthetic dental videos with corresponding ground truth forward and backward optical flows and occlusion masks. It can be used for:
-
Electrochemical investigations on corosivity of de-icing liquids for railway infrastructure
PublikacjaThe paper presents the results of electrochemical tests of the de-icing fluid for railway infrastructure. DC and AC electrochemical tests were performed to determine the corrosion rates of structural steel, cast iron and aluminium in the newly produced fluid. The results were compared with the corrosion rates of the same materials in the fluid without corrosion inhibitors. The obtained test results indicate a low corrosion risk...
-
Corrosion degradation of spacers – examination of changes in bone cement coating.
PublikacjaSpacer is a special implant used at the time of infection after endoprosthetic surgery. It consists of a metal core and bone cement coating with an antibiotic. In the human body spacers are exposed to degradation processes. This paper looks at the effect of corrosion on spacers. Electrochemical corrosion tests were performer on titanium pins with bone cement coating in two solutions: Ringer’s solution and artificial...
-
Effect of free water on the quasi‑static compression behavior of partially‑saturated concrete with a fully coupled DEM/CFD approach.
PublikacjaThe work aims to numerically investigate the quasi-static response of partially fluid-saturated concrete under two-dimensional uniaxial compression at the mesoscale. We investigated how the impact of free pore fluid content (water and gas) affected the quasi-static strength of concrete. The totally and partially fluid-saturated concrete behavior was simulated using an improved pore-scale hydro-mechanical model based on DEM/CFD....
-
Corrosion and Cavitation Resistances of Low Alloy Steel After Frictional-Mechanical Treatment
PublikacjaPaper presents the results of the studies of wear, corrosion and cavitation resistances of the S355J2 low alloy medium carbon steel subjected to surface modification by friction-mechanical treatment, as tested in sea water simulated solution. To evaluate the effect of the surface treatment, the comparative studies of the corrosive properties of the steel before and after treatment have been considered. The treatment due to a severe...
-
Experimental and numerical investigations of ultimate strength of degradated structures
PublikacjaThe presented work investigates the corrosion influence on the structural behaviour of structural elements. Nine welded large-scale stiffened plates, and 30 standard small specimens have been subjected to the accelerated marine immersed conditions. After corrosion testing, the specimens have been accurately measured in terms of surface characteristics. The coupon specimens were furtherly subjected to tensile loading to develop...
-
Degradation of implantable materials – in vivo and in vitro research
PublikacjaThe article concerns the biological and electrochemical degradation of metallic implants in vivo and in vitro studies. The in vivo research dealt with degradation of plates used to join bones, as well as endoprostheses. The most common damages were: metalosis, breaking in the microstructure changes, breaking in area of holes, as well as plastic deformation throughout the length of an implant. The material used for the research...
-
Simulations of hydro-fracking in rock mass at meso-scale using fully coupled DEM/CFD approach
PublikacjaThe paper deals with two-dimensional (2D) numerical modelling of hydro-fracking (hydraulic fracturing) in rocks at the meso-scale. A numerical model was developed to characterize the properties of fluid-driven fractures in rocks by combining the discrete element method (DEM) with computational fluid dynamics (CFD). The mechanical behaviour of the rock matrix was simulated with DEM and the behaviour of the fracturing fluid flow...
-
Biological and mechanical properties of bone cement with nanoarticles - in vitro and in vivo research
PublikacjaDespite antibiotic preventive treatment both before and after implant implementation, the risks of infection are real. These infections develop at the implant surface a few months after inserting them into the body. To prevent the development of bacteria and reduce the risk of infection, implants coated with nanoparticles are used. The Mechanical Department of the Technical University of Gdansk carries out research into using bone...
-
Very low resolution depth images of 200,000 poses
Dane BadawczeA dataset represents simulated images of depth sensor seeing a single human pose, performing 200,000 random gestures. The depth images as vectors of pixels are stored with ground truth positions of every relevant joint.
-
IN VIVO DEGRADATION OF BIOMATERIALS
PublikacjaThe material designed to be introduced into the human tissue should be biocompatible and biofunctional. Unless it is so, the body may respond to the implant in different ways. An inflammation reaction may appear such as: parting of items of the implant surface resulting from fraction or pressure. The condition of the surface has an important influence on the usefulness of the implant. The required values depend on the implant function...
-
Fluid–solid interaction on a thin platelet with high-velocity flow: vibration modelling and experiment
PublikacjaThe paper concerns the nonlinear behaviour of a thin platelet that is streamlined in an aerodynamic tunnel. The air velocity in the aerodynamic tunnel was at 858.9 km/h or 0.7 Ma (Ma—Mach number is a dimensionless quantity in fluid dynamics representing the ratio of flow velocity past a boundary to the local speed of sound). This experiment was numerically simulated using FSI (fluid–solid interaction) tools, namely the coupling...
-
Adenocarcinoma of lung, mucinous - Male, 78 - Cell image [1209063003013491]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Using Synchronously Registered Biosignals Dataset for Teaching Basics of Medical Data Analysis – Case Study
PublikacjaMedical data analysis and processing strongly relies on the data quality itself. The correct data registration allows many unnecessary steps in data processing to be avoided. Moreover, it takes a certain amount of experience to acquire data that can produce replicable results. Because consistency is crucial in the teaching process, students have access to pre-recorded real data without the necessity of using additional equipment...
-
Numerical Studies on Propellers in Open Water and behind Hulls aiming to support the Evaluation of Propulsion Tests
PublikacjaA RANS based numerical analysis of propellers can contribute considerably to our understanding of propeller/hull interaction. It may also allow for a review of scaling procedures on results from experimental fluid dynamics (EFD). Using various RANS codes (Fluent, CFX, STAR-CCM+ and FreSCo+) on common test cases the authors first focused on propeller open water (POW) calculations. Next we simulated the propeller hull interaction...
-
Investigations of Titanium Implants Covered with Hydroxyapatite Layer
PublikacjaTo reduce unfavorable phenomena occurring after introducing an implant into human body various modifications of the surface are suggested. Such modifications may have significant impact on biocompatibility of metallic materials. The titanium and it's alloys are commonly used for joint and dental implants due to their high endurance, low plasticity modulus, good corrosion resistance as well as biocompatibility. Special attention...
-
Modeling of subarachnoid space width change caused by blood circulation in brain vessels
PublikacjaThe subarachnoid space is an anatomic space, lying in the central nervous system, between the arachnoid membrane and the pia mater. It is filled with cerebrospinal fluid, which protects and nourishes the brain. The pathological disorder of the subarachnoid space (i.e. increase or decrease of its width) a ects the nervous system. Therefore, it is important to diagnose the width changes of the subarachnoid space. One way to support...
-
Biological and mechanical properties of bone cement with nanoparticles - in vivo and in vitro research
PublikacjaDespite antibiotics preventive treatment, before and after an implant implementation, risk of infection are real. These infections at the implant surface develop in a few months after applying them into the body. To prevent the development of bacteria and to reduce the risk of infection, implants coated with nanoparticles come into use. The Mechanical Department of the Technical University of Gdańsk carried out a research with...
-
The mechanisms of degradation of titanium dental implants
PublikacjaTitanium dental implants show very good properties, unfortunately there are still issues regarding material wear due to corrosion, implant loosening, as well as biological factors—allergic reactions and inflammation leading to rejection of the implanted material. In order to avoid performing reimplantation operations, changes in the chemical composition and/or modifications of the surface layer of the materials are used. This research...
-
Electrophoretic Deposition and Characterization of Chitosan/Eudragit E 100 Coatings on Titanium Substrate
PublikacjaCurrently, a significant problem is the production of coatings for titanium implants, which will be characterized by mechanical properties comparable to those of a human bone, high corrosion resistance, and low degradation rate in the body fluids. This paper aims to describe the properties of novel chitosan/Eudragit E 100 (chit/EE100) coatings deposited on titanium grade 2 substrate by the electrophoretic technique (EPD). The deposition...
-
Minichannel and minigap classification criteria based on the aspect ratio of the minigeometry: A numerical study
PublikacjaA detailed numerical investigation has been carried out to analyze the diabatic flow distribution and velocity profile in 18 minigeometries with various aspect ratios for V-type and I-type flow configurations (for 36 cases) assuming ethanol as a working fluid. The aim of the study is to distinguish the value of the aspect ratio for which the flow in minigeometry starts to be two-dimensional (minigap). Cases with a constant Reynolds...
-
Numerical investigation on the performance of a small counter-rotating wind turbine
PublikacjaThe article presents the results of the investigation on the performance of a small counter-rotating wind turbine. The wind turbine has been simulated using Computational Fluid Dynamics methods. Actuator Line Model has been successfully used to represent rotors in the computational domain. A parametric study has been carried out, taking into account changes in the tip speed ratio of the rotors while maintaining a constant distance...
-
Ion Chromatography with Pulsed Amperometric Detection for Determining Cyanide in Urine and Meconium Samples
PublikacjaThe parents’ addictions and eating habits have a significant influence on the child’s growth. The first stool of a newborn baby provides a large amount of information about xenobiotics transmitted by the mother’s body. The analytical technique used in the study is ion chromatography with pulsed amperometric detection (IC-PAD). The biological samples, which were obtained from women staying in a maternity ward and their partners,...
-
Real-time simulator of agricultural biogas plant
PublikacjaThis article presents a real-time simulator of an agricultural biogas plant. The project contains biogas and biomass circuits simulation, as well as heating circuit simulation with a complete control system and visualization interface of the whole process. The software tool used to simulate the plant work is CFD (Computational Fluid Dynamics), which enables a user to create and test simulation objects based on fundamental physical...
-
CFD Simulations and Tests of a Prototype Flow Control Valve
PublikacjaIn this paper a prototype of a flow control valve is described and numerically simulated. The flow control valve is used in hydraulic systems to maintain constant fluid flow despite changing loads of a receiver. The standard construction of this type of valves is modified mainly by eliminating the spring. The prototype consists the hydrostatically unloaded throttle valve and pressure ratio valve substituting pressure difference...
-
Experimental Verification of the CFD Model of the Squeeze Film Lifting Effect
PublikacjaAbstract: The presented study shows the results of the research into the squeeze film levitation phenomena. The system introduced in the investigation is composed of a vibrating surface, air squeeze film, and the surface of the body freely suspended over the film. The use of the CFD (Computational Fluid Dynamics) model used in the system allows us to determine the steady state, periodic behavior of the air film (described by Navier–Stokes,...
-
Influence of laser melting on surface layer properties of titanium alloy Ti6Al4V
PublikacjaIn time of rapid technology and medicine progress, implants are becoming more widely used in the human body, ranging from dental implants, stabilizing plates, screws, orthopaedic prostheses. For example, there are many types of hip prostheses used for hip replacement as well as various types of materials used for these orthopaedic prostheses. Properties of titanium alloys used in hip prostheses combined with good strength properties,...
-
Design of a Shape-Memory-Alloy-Based Carangiform Robotic Fishtail with Improved Forward Thrust
PublikacjaShape memory alloys (SMAs) have become the most common choice for the development of mini- and micro-type soft bio-inspired robots due to their high power-to-weight ratio, ability to be installed and operated in limited space, silent and vibration-free operation, biocompatibility, and corrosion resistance properties. Moreover, SMA spring-type actuators are used for developing different continuum robots, exhibiting high degrees...
-
The thermal effort during marine steam turbine flooding with water
PublikacjaThe work discussed an extreme case of cooling a steam turbine. The ship's steam turbine was used as an example. In marine transport units with low-speed engines dominate, however, there are also units with steam turbines. An example of analysed marine steam turbine is shown in Fig. 1. When considering the issue of cooling steam turbines, it is necessary to estimate the extreme conditions that may occur during operation of the turbine....
-
Biomechanics of the medial meniscus in the osteoarthritic knee joint
PublikacjaBackground. Increased mechanical loading and pathological response of joint tissue to the abnormal mechanical stress can cause degradation of cartilage characteristic of knee osteoarthritis (OA). Despite osteoarthritis is risk factor for the development of meniscal lesions the mechanism of degenerative meniscal lesions is still unclear. Therefore, the aim of the study is to investigate the influence of medial compartment knee OA...