Filtry
wszystkich: 5932
-
Katalog
- Publikacje 4596 wyników po odfiltrowaniu
- Czasopisma 58 wyników po odfiltrowaniu
- Konferencje 23 wyników po odfiltrowaniu
- Wydawnictwa 1 wyników po odfiltrowaniu
- Osoby 84 wyników po odfiltrowaniu
- Projekty 4 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 16 wyników po odfiltrowaniu
- Wydarzenia 4 wyników po odfiltrowaniu
- Dane Badawcze 1145 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: LOW-VOLTAGE NETWORK
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublikacjaRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublikacjaW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublikacjaW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
Improving voltage levels in low-voltage networks with distributed generation – case study
PublikacjaThe use of distributed generation in low-voltage networks may cause the voltage variation in them, within the wide range. In unfavourable circumstances, the voltage may reach unacceptable values. The paper presents the effect of distributed generation on voltage levels in a selected low-voltage rural distribution network in Poland. An analysis of possible methods for improving voltage levels in this network is conducted. The most...
-
Voltage Conditions in Low Voltage Grid with Connected Mictogeneration
PublikacjaThe introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...
-
Voltage profiles improvement in a power network with PV energy sources – results of a voltage regulator implementation
PublikacjaThe constant increase in the number of photovoltaic (PV) energy sources in distribution networks is the cause of serious voltage problems. The networks built at least a dozen years ago are not provided for the installation of a large number of micro-sources. It happens that the previously properly functioning power networks are not able to provide to consumers power with the required parameters, after installing many PV sources....
-
Low voltage photovoltaic power system
PublikacjaThe use of photovoltaics is growing rapidly in the industry as well as households. Therefore, educating the public will help them understand solar cell technology, which is becoming more common in everyday life. This paper proposes a demonstrational set-up of photovoltaic panel for the purpose of science education. It was used in numerous outreach activities such as science fairs. Moreover, it proved to be a great tool for education...
-
Multipulse inverter structures with low voltage distortion
PublikacjaA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...
-
Quality assessment of low voltage surge arresters
PublikacjaUsers expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...
-
A High-Efficient Low-Voltage Rectifier for CMOS Technology
PublikacjaA new configuration of rectifier suiting CMOS technology is presented. The rectifier consists of only two nchannel MOS transistors, two capacitors and two resistors; for this reason it is very favourable in manufacturing in CMOS technology. With these features the rectifier is easy to design and cheap in production. Despite its simplicity, the rectifier has relatively good characteristics, the voltage and power efficiency, and...
-
Control of a wind power generator in case of voltage sags in power network
PublikacjaW artykule poruszono problem związany ze sposobem sterowania generatorem elektrowni wiatrowej w przypadku wystąpienia po stronie sieci zapadów napięcia.Jako generator wykorzystano maszynę dwustronnie zasilaną której stojan podłączono bezpośrednio do sieci natomiast wirnik zasilano poprzez kaskadę przekształtników. Wystąpienie spadku lub zapadu napięcia sieci w przypadku pracy tego typu generatora może doprowadzić do uszkodzenia...
-
Low harmonic multipulse voltage converters using coupled reactors
PublikacjaThis paper presents a novel approach to the multi pulse voltage converters (VC), especially voltage source inverters (VSI) and matrix converters (MC) based on several typical identical modules connected in parallel using coupled reactors. Such arrangements resulting in lower voltage distortions at extremely low switching frequency. The proposed arrangement was validated by simulation. Laboratory models of 18- and 24pulse 3-level...
-
Use of AMI Meters in the Process of Low Voltage Grid Optimization
PublikacjaThis is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublikacjaAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublikacjaLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
Artificial Neural Network (ANN)-Based Voltage Stability Prediction of Test Microgrid Grid
Publikacja -
Dynamic current-voltage characteristics of dielectrics with extremely low heat conductivity
PublikacjaZaprezentowano teoretyczny opis metody dynamicznych charakterystyk prądowo-napięciowych w przypadku znacznego gradientu temperatury w ciałach stałych o przewodności jonowej. Otrzymano rozwiązania równania transportu oraz równania charakterystyk, odnoszące się do ruchu cienkiej warstwy nośników ostałej grubości oraz warstwy rozszerzającej się. Podano także przybliżone wyrażenia opisujące czas przelotu nośników. Wyniki zweryfikowano...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublikacjaOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublikacjaThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Output-capacitorless low-dropout regulator using a cascoded flipped voltage follower
PublikacjaPrzedstawiono udoskonaloną konfigurację wtórnika napięciowego w odwróconej konfiguracji oraz jej zastosowanie w regulatorze o małym spadku napięcia. W pracy przedstawiono teoretyczną analizę podstawowych parametrów wtórnika oraz regulatora napięcia. Ponadto przedstawiono wyniki pomiarów parametrów prototypowego układu scalonego wykonanego z użyciem technologii CMOS 0.35 um. Uzyskane wyniki porównano z rezultatami uzyskanymi w innych...
-
Protection against electric shock in electrical installations with low voltage generating sets
PublikacjaW referacie przedstawiono zasady ochrony przeciwporażeniowej, zgodne z wymaganiami międzynarodowymi, w sytuacji kiedy instalacja elektryczna jest zasilana z niskonapięciowych zespołów prądotwórczych. Zwrócono uwagę na dobór zabezpieczeń przeciwporażeniowych oraz na wymiarowanie uziemień.
-
Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid
PublikacjaCurrent low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublikacjaResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Random components influence on the values characterising periodic disturbances in low voltage supply lines.
PublikacjaAnalizowano wpływ składowych losowych na wielkości charakteryzujących zaburzenia okresowe w napięciu zasilania na przykładzie współczynnika zawartości harmonicznych (THD). Zaprezentowano sposób wyznaczania niepewności pomiaru współczynnika THD, uwzględniający występowanie korelacji pomiędzy składową podstawową i kolejnymi harmonicznymi napięcia sieci a także między poszczególnymi harmonicznymi. Przedstawiono analizę wyników z pomiarów...
-
The measurement of input power of power supply in network disturbed by low frequency distortions
PublikacjaIn the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed
-
Low-Voltage LDO Regulator Based on Native MOS Transistor with Improved PSR and Fast Response
PublikacjaIn this paper, a low-voltage low-dropout analog regulator (ALDO) based on a native n-channel MOS transistor is proposed. Application of the native transistor with the threshold voltage close to zero allows elimination of the charge pump in low-voltage regulators using the pass element in a common drain configuration. Such a native pass transistor configuration allows simplification of regulator design and improved performance,...
-
Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse
Publikacjahe development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm....
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublikacjaLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublikacjaA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Neural network based algorithm for hand gesture detection in a low-cost microprocessor applications
PublikacjaIn this paper the simple architecture of neural network for hand gesture classification was presented. The network classifies the previously calculated parameters of EMG signals. The main goal of this project was to develop simple solution that is not computationally complex and can be implemented on microprocessors in low-cost 3D printed prosthetic arms. As the part of conducted research the data set EMG signals corresponding...
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
PublikacjaThis paper presents an inductive power transfer system on the basis of a double single- phase three-level T-type inverter and two split transmitting coils for constant current and constant voltage wireless charging of low-voltage light electric vehicle batteries with closed-loop control, considering time-delay communication constraints. An optimal control structure and a modified control strategy were chosen and implemented to...
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
Publikacja -
The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid
PublikacjaThis paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublikacjaVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Hybrid stepless distribution transformer with four-quadrant AC/DC/AC converter at low voltage side - simulation tests
PublikacjaThe article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic...
-
Multipath routing for quality of service differentiation and network capacity optimization in broadband low-earth orbit systems
PublikacjaThis paper shows the importance of employing multiple different paths for routing in Inter-Satellite Link (ISL) networks in broadband Low-Earth Orbit (LEO) satellite systems. A theoretical analysis is presented and a routing concept is proposed to demonstrate three facts that make multipath routing especially important in broadband LEO networks: (1) differences in the propagation delays have a much greater impact on end-to-end...
-
Zastosowanie algorytmu ewolucyjnego do uczenia neuronowego regulatora napięcia generatora synchronicznego. Evolutionary algorithm for training a neural network of synchronous generator voltage controller
PublikacjaNajpopularniejsza metoda uczenia wielowarstwowych sieci neuronowych -metoda wstecznej propagacji błędu - charakteryzuje się słabą efektywnością. Z tego względu podejmowane są próby stosowania innych metod do uczenia sieci. W pracy przedstawiono wyniki uczenia sieci realizującej regulator neuronowy, za pomocą algorytmu ewolucyjnego. Obliczenia symulacyjne potwierdziły dobrą zbieżność algorytmu ewolucyjnego w tym zastosowaniu.
-
QUASI-DISTRIBUTED NETWORK OF LOW-COHERENCE FIBER-OPTIC FABRY-PÉROT SENSORS WITH CAVITY LENGTH-BASED ADDRESSING
PublikacjaDistributed measurement often relies on sensor networks. In this paper, we present the construction of low coherent fiber-optic Fabry-Pérot sensors connected into a quasi-distributed network. We discuss the mechanism of spectrum modulation in this type of sensor and the constraints of assembly of such sensors in the network. Particular attention was paid to separate the signals from individual sensors, which can be achieved by...
-
The scanning electron microscopy (SEM) studies of low voltage copper cables
Dane BadawczeThe dataset contains the scanning electron microscopy (SEM) images of the low voltage copper cables, which were studied in the article discussing the regulatory requirements for checking the electrical resistance of such cables. The cables were cut and studies in cross-section. The full results were published in:
-
Impact of R/X ratio of distribution network on selection and control of energy storage units
PublikacjaThe interest in energy storage is still increasing. Energy storage units are installed in high voltage networks, medium voltage networks and low voltage distribution networks as well. These units are often used to improve power quality. One of the criteria for improving power quality is reducing voltage deviations. Depending on the type of network and specifying its R/X ratio, this criterion can be fulfilled by control of active...
-
A new approach to cross-bonding in medium voltage cable lines
PublikacjaThe medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints...
-
Low Current Transformer Utilizing Co-Based Amorphous Alloys
PublikacjaMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Low current transformer utilizing Co-based amorphous alloys
PublikacjaMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublikacjaIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system during sea trials
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier during sea trials.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials during maneuvering.
-
Quality Evaluation of Voice Transmission Using BPL Communication System in MV Mine Cable Network
PublikacjaThis article presents results of a quality evaluation study, considering voice transmission in a 6 kV medium voltage cable network using the BPL (Broadband over Power Line) communication system. The tests are carried out under real mining conditions for the selected power cable without voltage, earthed at both sides. Such a method of monitoring work conditions is of great importance, especially during a disaster. Power cables are...
-
Integrated algorithm for selecting the location and control of energy storage units to improve the voltage level in distribution grids
PublikacjaThis paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing...
-
The Influence of a Photovoltaic Micro-Installation on the Low-Frequency Parameters of Electricity at PCC and Its Impact on the Thermal Characteristics of Selected Devices
PublikacjaThis manuscript illustrates the measurement results of parameters describing the quality of energy at the PCC (point of common coupling) of a photovoltaic micro-installation that can significantly affect devices in the same power grid. The analyses reflecting heating of selected devices used in domestic installations, which were performed in an isolated laboratory environment, are also indicated. The conducted study aimed at checking...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during maneuvering.
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a layover at the port
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a layover at the port.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials. The data were recorded during a sea voyage, under normal...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a layover at the port
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a layover at the port.
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors
Dane BadawczeThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Porównanie działania transformatora symetryzującego (zygzak) z aktywnym energoelektronicznym symetryzatorem prądów fazowych linii niskiego napięcia
PublikacjaNa potrzeby planowania sieci niskiego napięcia operatorzy systemów dystrybucyjnych (OSD) zakładają symetryczne warunki obciążenia linii. Z roku na rok, rośnie liczba rozproszonych systemów fotowoltaicznych (PV) zainstalowanych w sieciach niskiego napięcia, których większość to małe jednofazowe systemy dachowe. Dodatkowo, do niesymetrii obciążenia przyczyniają się instalowane masowo pompy ciepła i ładowane jednofazowo samochody...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a sea voyage.
-
Generalized regression neural network and fitness dependent optimization: Application to energy harvesting of centralized TEG systems
PublikacjaThe thermoelectric generator (TEG) system has attracted extensive attention because of its applications in centralized solar heat utilization and recoverable heat energy. The operating efficiency of the TEG system is highly affected by operating conditions. In a series-parallel structure, due to diverse temperature differences, the TEG modules show non-linear performance. Due to the non-uniform temperature distribution (NUTD) condition,...
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during maneuvering.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a bow thruster start-up
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. In ships' electrical power systems, disturbances occurring in voltage waveforms on bus bars of the main switchboard are connected mainly with the processes...
-
Uproszone modelowanie sieci dystrybucyjnej na potrzeby analiz przyłączeniowych
PublikacjaW artykule przedstawiono rozważania na temat sposobu modelowania sieci średniego (SN) i niskiego (nn) napięcia na potrzeby wykonywania analiz przyłączeniowych przez operatorów sieci dystrybucyjnej. Przeprowadzono dyskusję na temat możliwych do wykonania uproszczeń w modelowaniu sieci, które są do zaakceptowania z punktu widzenia uzyskiwanego wyniku końcowego. Głównym elementem wymuszającym uproszenia w modelowaniu jest środowisko...
-
Regulacja napięcia w sieci nN z rozproszonymi źródłami energii
PublikacjaPodłączanie rozproszonych źródeł energii do sieci energetycznych niskiego napięcia powoduje powstawanie problemów zmienności i niesymetrii napięcia, zwłaszcza w przypadku dużych odległości od transformatora zasilającego. W skrajnych przypadkach zachodzi konieczność redukcji mocy generowanej przez źródło podczas oddawaniu energii do sieci. Rozwiązaniem tego problemu jest zastosowanie energoelektronicznego regulatora napięcia składającego...
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors_part_2
Dane BadawczeThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Stanisław Galla dr inż.
OsobyUrodził się w 1970 w Gdańsku. Jest absolwentem Technikum Mechaniczno Elektrycznego w Gdańsku (1990). Studiował na Wydziale Elektrotechniki Politechniki Gdańskiej (studia ukończył w 1996). Rozprawę doktorską pt. „Metodyka zwiększania dokładności pomiarów małoczęstotliwościowych wskaźników zaburzeń okresowych występujących w sieciach niskiego napięcia” obronił w 2009 r na Wydziale Elektrotechniki i Automatyki Politechniki Gdańskiej....
-
An Overview of Bidirectional EV Chargers: Empowering Traction Grid-Powered Chargers
PublikacjaIn recent years, the number of electric vehicles has been at least doubling year after year. As a result, today electric vehicles already account for approximately 10% of the global automotive market, which positively affects environment in urbanized areas. However, to take full advantage of the EV integration it is necessary to use renewable sources for their charging; optimally place charging stations/terminals; optimally manage...
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a sea voyage.
-
Metody doboru miejsc zainstalowania zasobników energii w sieciach elektroenergetycznych niskiego napięcia
PublikacjaW związku z rosnącą liczbą źródeł odnawialnych przyłączanych do sieci niskiego napięcia (nn) jakość energii elektrycznej w tej sieci ulega pogorszeniu. Jedną z metod jej poprawiania jest instalowanie zasobników energii, tj. baterii akumulatorów, superkondensatorów czy kół zamachowych. Zasobniki energii są w stanie złagodzić dobową zmienność obciążenia, skompensować moc bierną i wyższe harmoniczne oraz zmniejszyć asymetrię obciążenia...
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublikacjaThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublikacjaThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
The short-term flicker severity level measured in the industrial power system supplying the rolling mill motors
Dane BadawczeThe dataset presents a short-term flicker severity level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of...
-
Room temperature depinning of the charge-density waves in quasi-two-dimensional 1T-TaS2 devices
PublikacjaWe report on the depinning of nearly commensurate charge-density waves in 1T-TaS2 thin films at room temperature. A combination of the differential current–voltage measurements with the low-frequency noise spectroscopy provides unambiguous means for detecting the depinning threshold field in quasi-2D materials. The depinning process in 1T-TaS2 is not accompanied by an observable abrupt increase in electric current—in striking contrast...
-
Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors
PublikacjaThis paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...
-
Static Shunt PE Voltage-Quality Controllers
PublikacjaThis chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...
-
Selection of energy storage units by genetic algorithm for mitigating voltage deviations
PublikacjaIn recent years, energy storage units have become very popular. They are applied both for economic and technical purposes. Unfortunately, the cost of such devices is still high and selecting their proper location and rated power have to be performed precisely. In this paper, a Genetic-Algorithm-based optimization method for selecting the best configuration of energy storage units in the power network is proposed. The presented...
-
Synchronized six-step voltage generation in high-speed PMSM drive
PublikacjaSynchronized voltage generation has already been considered in the context of pulse width modulation (PWM). References prove that synchronized PWM substantially decreases subharmonics in inverter output voltage when operating with low switching-to-fundamental frequency ratio. This paper identifies problems of unsynchronized voltage generation in electric drives under six-step inverter operation. Guidelines for the synchronization...
-
The Impact of Micro-Sources on Voltage Distortions in a Power Grid
PublikacjaThe increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...
-
Jerzy Konorski dr hab. inż.
OsobyJerzy Konorski otrzymał tytuł mgr inż. telekomunikacji na Poitechnice Gdańskiej, zaś stopień doktora n.t. w dyscyplinie informatyka w Instytucie Podstaw Informatyki PAN. W r. 2007 obronił rozprawę habilitacyjną na Wydziale Elektroniki, Telekomnikacji i Informatyki PG. Jest autorem ponad 150 publikacji naukowych, prowadził projekty naukowo-badawcze finansowane ze środków Komitetu Badań Naukowych, UE, US Air Force Office of Scientific...
-
A 0.5-V bulk-driven voltage follower / DC level shifter and its application in class AB output stage
PublikacjaA simple realization of a 0.5-V bulk-driven voltage follower/DC level shifter, designed in a 0.18um CMOS technology is presented in the paper. The circuit is characterized by large input and output voltage swings, and a DC voltage gain close to unity. The DC voltage shift between input and output terminals can be regulated in a certain interval around zero, by means of biasing current sinks. An application of the proposed voltage...
-
Design of synchronous generator voltage regulator based on h control theory
PublikacjaThe power system is highly nonlinear system, which dynamics depends on system network configuration, system loading…etc. To overcome the above mentioned difficulties and to fulfill the performance requirements the different control methods are considered and tested for application to generating control unit. Application of the H optimization method to automatic voltage regulator is studied in this paper. Simulation results have...
-
Hybrid Modulation for Modular Voltage Source Inverters with Coupled Reactors
PublikacjaThis paper proposes and discusses a concept of a hybrid modulation for the control of modular voltage source inverters with coupled reactors. The use of coupled reactors as the integrating elements leads to significant reduction in the size and weight of the circuit. The proposed modulation combines novel coarsely quantized pulse amplitude modulation (CQ-PAM) and innovative space-vector pulse width modulation (SVPWM). The former...
-
Modular multipulse voltage source inverters with integrating coupled reactors
PublikacjaA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...
-
Quality assessment of high voltage varistors by third harmonic index
PublikacjaHigh voltage varistors that consist of grained ZnO have to be tested before assembling into a surge arrester. The existing methods demand a usage of high voltages and intensive currents that is inconvenient, destructive and needs extensive power consumption. Additionally, these methods require metallization of the prepared varistor structures that increases costs. We propose another method of varistors quality assessments by a...
-
The Influence of Limiters UEL and OEL (The power angle, stator's current and excitation current) ot the possibility of voltage collapse development
PublikacjaVoltage stability has been a major concern for power system utilities because of event of voltage collapses in the recent past. Sometimes, power system events have shown the need for generators to operate in the overexcited and underexcited region to support stable operation. Modern excitation systems include devices for controlling or limiting machine terminal voltage (overvoltage limiters), volts per hertz ratio (V/Hz limiters),...
-
Voltage Transients Transfer over Medium Voltage Instrument Transformers
PublikacjaThis paper presents voltage harmonic transfer accuracy problems through voltage transformers which are used in power quality monitoring systems in medium and high voltage grids. A simplified lumped parameters circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number voltage transformers typically used in medium voltage grid has been tested in the conducted disturbances...
-
Third harmonic index as a diagnostic tool of high-voltage varistors
PublikacjaThe recommended methods for standard testing of high-voltage varistors demand application of high voltages and intensive currents that is inconvenient and needs extensive power consumption. These methods require metallization of the prepared ZnO structures that increases costs of testing. Another method of varistor quality and endurance evaluation by the third harmonic index measurement at relatively low voltage range has been...
-
Voltage Harmonics Transfer through Medium Voltage Instrument Transformers
PublikacjaVoltage transformers are widely used in power quality monitoring systems in medium and high voltage grids. This paper presents accuracy problems related to voltage harmonics transfer through instrument transformers. A simplified lumped-parameters wideband circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number of voltage transformers have been tested in the frequency...
-
The Methodology of identifying the place to install shunt compensators in the transmission network
PublikacjaThis methodology of selection and localization of static com- paper presents pensators in wide network. Proposed method is based on analysis of voltage area power profiles in the nodes of the power grid, and designating locations, In Which Voltages ex- cessively tend to change in time. Practical way of modeling the SVC device in PLANS program you Presented, as well as some example results of research.
-
Low cost set-up for supercapacitors parameters evaluation
PublikacjaWe propose a use of a power amplifier in the circuit of voltage to current converter (current driver) for supercapacitor charging/discharging in controlled conditions. The current driver is controlled by DAC output of DAQ board and voltage of DUT is measured and a control loop is realized by software. In the circuit the DC current method of evaluation of capacitance and equivalent series...
-
Voltage Dependence of Supercapacitor Capacitance
PublikacjaElectronic Double-Layer Capacitors (EDLC), called Supercapacitors (SC), are electronic devices that are capable to store a relatively high amount of energy in a small volume comparing to other types of capacitors. They are composed of an activated carbon layer and electrolyte solution. The charge is stored on electrodes, forming the Helmholtz layer, and in electrolyte. The capacitance of supercapacitor is voltage- dependent. We...
-
Quasi-resonant DC-link voltage inverter with enhanced zero-voltage switching control
PublikacjaA new topology modification of the parallel quasi-resonant circuit for a dc-link voltage inverter enables regulation of the zero voltage dc-link subperiods and the dc-link voltage gradient settings. The proposed circuit is based on four MOSFET switches with free-wheeling diodes for controlled quasi-resonant recharging between L-C tank in order to assure inverter zero voltage switching (ZVS) conditions. Design optimization of the...
-
Modified Inductive Multi-Coil Wireless Power Transfer Approach Based On Z-Source Network
PublikacjaThis article presents a non-conventional approach to a multi-coil wireless power transfer system based on a Z-source network. The novelty of the approach lies in the use of a Z-source as a voltage source for energy transmission through the wireless power transfer coils. The main advantage is in a reduced number of semiconductors. This paper provides the design approach, simulation and experimental study. Feasibility and possible...
-
Intelligent turbogenerator controller based on artifical neural network
PublikacjaThe paper presents a desing of an intelligent controller based on neural network (ICNN). The ICNN ensures at the same time two fundamental functions : the maintaining of generator voltage at the desired value and the damping of the electromechanical oscillations. Its performance is evaluted on a single machine infinite bus power system through computer simulations. The dynamic and transient operation of the proposed controller...
-
Selection of optimal location and rated power of capacitor banks in distribution network using genetic algorithm
PublikacjaIn this paper, the problem of placement and rated power of capacitor banks in the Distribution Network (DN) is considered. We try to suggest the best places for installing capacitor banks and define their reactive power. The considered formulation requires the optimization of the cost of two different objectives. Therefore the use of properly multiobjective heuristic optimization methods is desirable. To solve this problem we use...
-
Problems with microprocessor voltage-to-frequency and frequency-to-voltage converters implementation
PublikacjaThe article presents the problems of digital voltage-to-frequency and frequency-to-voltage processing. Transducer systems implemented in microprocessor technology are presented, the timing of signals and functioning algorithms are discussed. An analysis of processing errors has been performed and the results of experimental studies of realized systems are presented.
-
Niskonapięciowy filtr analogowy CMOS wykorzystujący konwerter ujemnoimpedancyjny
PublikacjaA low-voltage 3-order low-pass CMOS filter based on the novel current inversion type negative impedance converter (CNIC) is presented. It shows a badwidth of 10 MHz at 400 uW power consumption and 2 V supply voltage when realized in a 0.35 um CMOS process.
-
Niskonapięciowy filtr analogowy CMOS oparty o konwerter ujemno-impedancyjny
PublikacjaA low-voltage 3-order low-pass CMOS filter based on the novel current inversion type negative impedance converter (CNIC) is presented. It shows a badwidth of 10 MHz at 400 uW power consumption and 2 V supply voltage when realized in a 0.35 um CMOS process.
-
Photovoltaic effect in the single-junction DBP/PTCBI organic system under low intensity of monochromatic light
PublikacjaPhotoelectric properties of the planar ITO/MoO3/DBP/PTCBI/BCP/Ag system were characterized on the basis of short-circuit current, open-circuit voltage and absorption spectra, and current-voltage measurements in the dark and under monochromatic illumination of low intensity. Photovoltaic performance of the system was compared with the performance of ideal semiconductor and excitonic cells of chosen bandgaps. Such analysis shows,...
-
Static Series and Shunt-series PE Voltage-quality Controllers
PublikacjaAs presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...
-
Estimation of the uncertainty of the AC/AC transducer output voltage
PublikacjaThe paper presents a methodology for estimating uncertainty of voltage transducers processing function, on the example of CYVS411D07 voltage transducers. The analysis was conducted using the method based on the GUM Guide propagation of uncertainty law and the determination of the coverage factor based on the effective number of degrees of freedom (t-Student distribution). The paper also presents example evaluation results of measured...
-
Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid
PublikacjaOne of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...