Wyniki wyszukiwania dla: MAGNETIC FIELD
-
Determination of magnetisation conditions in a Double-Core Barkhausen Noise measurement set-up
PublikacjaThe magnetic Barkhausen effect is useful forassessing 1D and 2D stress states of ferromagnetic steelobjects. However, its extension to technically importantmaterials, such as duplex anisotropic steels, remains challenging. The determination of magnetisation inside the studied object and the electromagnet for various geometries, materials and magnetisation angles is a key issue.Three-dimensional, dynamic finite element analysis...
-
Mono- and bimetallic (Pt/Cu) titanium(IV) oxide photocatalysts. Physicochemical and photocatalytic data of magnetic nanocomposites’ shell
PublikacjaSurface modification of titania with noble and semi-noble metals resulted in significant enhancement of photocatalytic activity. Presented data, showing the photocatalytic properties of TiO2-M (where M is Pt and/or Cu) photocatalysts were further used as Fe3O4@SiO2/TiO2-M magnetic nanocomposites shells in "Mono- and bimetallic (Pt/Cu) titanium(IV) oxide core-shell photocatalysts with Vis light activity and magnetic separability"...
-
High-conducting Bi4V2-xFexO11-δ ceramics containing Fe2O3 nanocrystals: Structure and properties
PublikacjaThe topography, structure, thermal, magnetic, and electrical properties of Bi4V2-xFexO11-δ ceramics substituted with x = 0.5 and 0.7 Fe were studied. The microscope analysis showed the presence of iron-rich nanocrystals formed on the Bi-Fe-V-O grains. The X-ray diffraction studies confirmed that grains are built mostly of tetragonal Bi4V1.5Fe0.5O10.5 phase. Thermal properties analysis showed an order-disorder type γ ↔ γʹ phase...
-
Mössbauer Spectroscopy and Magnetoelectric Effect Studies of Multiferroic Ceramics Based on BiFeO<sub>3</sub>
PublikacjaIn this work the results of investigations for (BiFeO3)x(BaTiO3)1-x and Bi1-xNdxFeO3 solid solutions are described. Samples were prepared by the conventional solid-state sintering method. X-ray diffraction, 57Fe Mössbauer spectroscopy, and magnetoelectric effect measurements were applied as complementary methods to determine the structure and magnetic properties of materials. For (BiFeO3)x(BaTiO3)1-x solid solutions Mössbauer...
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublikacjaThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
3D model of osteoarthritic (OA) knee joint for analysis of the medial meniscus biomechanics - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the OA model thickness of articular cartilage and material parameters of the cartilage and menisci were reduced to simulate degenerative changes in the...
-
3D knee model G with reduced thickness of articular cartilage - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the model G articular cartilage thickness was reduced in specific areas to simulate degenerative changes in the medial knee osteoarthritis. The file was...
-
3D knee model M with decreased material parameters of the cartilage and menisci - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the model M the material parameters of cartilage and menisci were reduced to simulate degenerative changes in the medial knee osteoarthritis. The file...
-
Growth, Crystal Structure and Magnetic Characterization of Zn-Stabilized CePtIn4
PublikacjaThe growth and characterization of CePtIn4, stabilized by 10% Zn substitution for In, is reported. The new material is orthorhombic, space group Cmcm (No. 63), with lattice parameters a = 4.51751(4) Å, b = 16.7570(2) Å, and c = 7.36682(8) Å, and the refined crystal composition has 10% of Zn substituted for In, i.e., the crystals are CePt(In0.9Zn0.1)4. Crystals were grown using a self-flux method: only growths containing Zn yielded...
-
Study on the applicability of the measurements of magnetoelastic properties for a nondestructive evaluation of thermally inducted microstructure changes in the P91 grade steel
PublikacjaThe paper presents the resuIts of the investigation of the influence of duration and temperature oftempering process on the magnetoacoustic properties of P91 tempered martensite ferritic steeI. Duringtempering of martensitic steels the dislocation density. which initially is very high. systematicallydecreases what is confirmed both by analysis of the width of X-ray diffraction peaks and hardnessmeasurements. Magnetic hysteresis...
-
On the geometrically nonlinear vibration of a piezo-flexomagnetic nanotube
PublikacjaIn order to describe the behavior of thin elements used in MEMS and NEMS, it is essential to study a nonlinear free vibration of nanotubes under complicated external fields such as magnetic environment. In this regard, the magnetic force applied to the conductive nanotube with piezo-flexomagnetic elastic wall is considered. By the inclusion of Euler-Bernoulli beam and using Hamilton’s principle, the equations governing the system...
-
A magnetic stir bar sorbent of metal organic frameworks, carbon foam decorated zinc oxide and cryogel to enrich and extract parabens and bisphenols from food samples
PublikacjaA porous composite magnetic stir bar adsorbent was fabricated for the extraction and enrichment of parabens and bisphenols from selected beverage samples. The adsorbent comprised a metal organic framework, carbon foam decorated zinc oxide and magnetic nanoparticles embedded in polyvinyl alcohol cryogel. The porous composite stir bar adsorbent could adsorb parabens and bisphenols via hydrogen bonding, π-π and hydrophobic interactions....
-
Thermodynamics of solid phases containing rare earth oxides
PublikacjaRare earth elements (RE) are incorporated into a large variety of complex oxide phases to provide tailored mechanical, electrical, optical, and magnetic properties. Thermodynamics control phase stability, materials compatibility in use, corrosion, and transformation. This review presents, in one compilation, the thermodynamic properties of a large number of such materials and discusses systematic trends in energetics and the factors...
-
Resonant Frequencies in the Open Microstrip Structures Placed on Curved Surfaces
PublikacjaThe paper presents the research on open microstrip structures placed on curved surfaces such as cylindrical, elliptical or spherical. The numerical analysis of investigated structures is based on expansion of electric and magnetic fields into suitable function series. Utilizing the continuity conditions the boundary problem is formulated which is solved with the use of method of moments. The investigated structures find application...
-
MAGNETOACOUSTIC HEATING AND STREAMING IN A PLASMA WITH FINITE ELECTRICAL CONDUCTIVITY
PublikacjaNonlinear effects of planar and quasi-planar magnetosound perturbations are discussed. Plasma is assumed to be an ideal gas with a finite electrical conductivity permeated by a magnetic filed orthogonal to the trajectories of gas particles. the excitation of non-wave modes in the filed of intense magnetoacoustic perturbations, i.e., magnetoaciustic heating and streaming, is discussed. The analysis includes a derivation if instantaneous...
-
Determination of denaturation temperature of connective tissue proteins by viscometric measurements.
Dane BadawczeViscometric denaturation temperature of connective tissue proteins was determined by measuring viscosity with a Brookfield viscometer, using a LV SC4 - 18, 25 or LV3 spindle and shear rates from 50 to 110 s-1 (Fig.1). Freeze-dried protein samples were dissolved in 0.5 M acetic acid at 4 °C and concentration of 20 mg/mL. The solution was stirred with...
-
On the application of magnetoelastic properties measureme nts for plastic level determination in martensitic steels
PublikacjaThe change in the dislocation density, induced by plastic deformation, influences strongly the magnetic domain structure inside the material. Being so, classic parameters, like the coercivity or magnetic permeability, can be a good measure of the deformation level, yet their reliable determination in a non-destructive way in industrial environment is problematic. The magnetoacoustic emission (MAE) which results from the non-180...
-
Synthesis and properties of AxV2Al20 (A = Th, U, Np, Pu) ternary actinide aluminides
PublikacjaPolycrystalline samples of AxV2Al20 (A = Ce, Th, U, Np, Pu; 0.7 ≤ x ≤ 1.0) actinide intermetallics were synthesized using the arc-melting method. Crystal structure studies were performed by means of powder x-ray diffraction and the Rietveld refinement method. All studied compounds crystallize in the CeCr2Al20-type structure (space group Fd-3m, no. 227) with the actinoid and Ce atom located in the oversized icosahedral cage formed...
-
Structure and paramagnetism in weakly correlated Y8Co5
PublikacjaWe report the basic physical properties of monoclinic Y8Co5 determined by means of magnetic susceptibility, electrical resistivity, and specific heat measurements. The crystal structure of Y8Co5 is monoclinic (P21/c) with lattice parameters a = 7.0582(6) Å, b = 7.2894(6) Å, c = 24.2234(19) Å, and β = 102.112(6)° as refined by using synchrotron powder x-ray diffraction data. The compound shows temperature independent paramagnetism...
-
Simplified Approach for Broadband RF Testing of Low Loss Magneto-Dielectric Samples
PublikacjaIn this paper, an attractive measurement techniqueis proposed to retrieve the broadband permittivity and permeabil-ity of the magneto-dielectric materials. The proposed techniqueis quite novel which mitigates the major problems associatedwith the conventional broadband RF material characterizationtechniques such as numerical instability and phase uncertaintywhen the length of the sample exceeds...
-
An air-assisted dispersive liquid phase microextraction method based on a hydrophobic magnetic deep eutectic solvent for the extraction and preconcentration of melamine from milk and milk-based products
PublikacjaIn the current research, a fast and sustainable air-assisted hydrophobic magnetic deep eutectic solvent-based dispersive liquid phase microextraction followed by UV–Vis spectrophotometry measurements was optimized for the extraction and determination of melamine in milk and milk-based products. The central composite design was applied for the optimization of factors affecting the recovery of melamine. Quantitative extraction of...
-
Simulation of hybridized nanofluids flowing and heat transfer enhancement via 3-D vertical heated plate using finite element technique
PublikacjaThe present study probed the creation of heat energy and concentrating into Newtonian liquids across vertical 3D-heated plates. The role of the Soret and Dufour theories in concentrating and energy formulas is discussed. The role of hybrid nanoparticles is introduced to illustrate particle efciency in terms of solute and thermal energy. It is removed a viscous dissipation process and a changing magnetic feld. The proposed approach...
-
TiO2-based magnetic nanocomposites with core-shell structure
PublikacjaThe main aim of the doctoral dissertation was preparation and characterization of photocatalysts, with particular emphasis on modified titanium (IV) oxide photocatalysts, which can be applied for the degradation of organic pollutants not susceptible to biodegradation. A particularly important aspect of the work was the development of preparation method of nanocomposites with the magnetic core-shell and photocatalyst shell (TiO2)...
-
Resonant Frequencies in Microstrip Structure with Omega Medium Substrate
PublikacjaThe paper presents the research on a rectangular microstrip structure with multilayer substrate containing dielectric and omega medium layers. The effect of pseudochiral medium layer location in the substrate and its thickness on the resonant frequency of the rectangular microstrip structure is investigated. The numerical analysis of investigated structures is based on expansion of electric and magnetic fields. Utilizing the continuity...
-
Sample Rate Conversion with Fluctuating Resampling Ratio
PublikacjaIn this paper a sample rate conversion with continuouslychanging resampling ratio has been presented. The proposed implementation is based on variable fractional delay filter implemented using a Farrow structure. It have been demonstrated that using the proposed approach instantaneous resampling ratio can be freely changed. This allows for simulation of audio recored on magnetic tape with nonuniform velocity as well as removal...
-
Design and Preparation of Magnetically-Oriented Poly(styr-co-MMA)-3MPS Capped Fe(ZnO) Hybrid Microspheres for Ion Exchange Removal of Toxic Pollutants from Wastewater
PublikacjaIn this work, polymeric microspheres derived from polystyrene-co-methyl methacrylate embedded with magnetic ZnO nanoparticles (poly(styrene-co-MMA)-3MPS-Fe (ZnO)) were synthesized using the suspension polymerization method. The surfaces of polymeric Fe(ZnO) microspheres were improved by functionalization with amino and sulphonate groups. The physicochemical analysis indicated a large number of positively charged (anion exchange)...
-
Gains selection of non-proportional observers of an induction motor with dyadic methods
PublikacjaThe paper presents issues related to calculation of gains of non-proportional observers of magnetic fluxes of an induction motor. A transformation is discussed, based on dyadic matrices, that affords possibility of applying well-known methods used in single-output systems to observers of multi-output systems. The impact of dyadic transformation on possibility of poles placement of the observer is analyzed....
-
Sample Rate Conversion with Fluctuating Resampling Ratio
PublikacjaIn this paper a sample rate conversion with continuously changing resampling ratio has been presented. The proposed implementation is based on variable fractional delay filter implemented using a Farrow structure. It have been demonstrated that using the proposed approach instantaneous resampling ratio can be freely changed. This allows for simulation of audio recored on magnetic tape with nonuniform velocity as well as removal...
-
Evaluation of structural change during fast transformation process of cross-linked NR into liquid NR by light pyrolysis
PublikacjaThe presence of cross-linked networks in rubber creates a tremendous problem for recycling and reusing of waste rubber. Fast transformation of cross-linked natural rubber (NR) into liquid natural rubber was carried out by light pyrolysis in temperature range from 240 to 300 °C in variable time (in range: 1–30 min). The transformation efficiency was evaluated by measuring the sol fraction and the cross-link density of the gel fraction....
-
Biocompatibility and potential functionality of lanthanum-substituted cobalt ferrite spinels
PublikacjaBulk and nanostructurized lanthanum-cobalt spinels have attracted a lot of interest from researchers, due to their unique physical and chemical properties as well as functionalities, which are interesting for biomedical and electronic industries. In this manuscript we show that introducing small lanthanum (La3+) content can tune magnetic, electronic and cytotoxic properties of the CoFe2− xLaxO4 system (x ≤ 0.1). The mechanisms...
-
Magnetic flux leakage signals of near side defects measured with different velocities
Dane BadawczeThe dataset contains raw signals measured with the use of the magnetic flux leakage (MFL) technique. Linear Hall effect sensors A1324 were used to measure magnetic flux leakage. Three voltage signals were measured: Bx sensor output, Bz1 sensor output, and difference of Bz1 and Bz2 outputs. An output of a Bx sensor was directly proportional to the tangential...
-
Magnetic flux leakage signals of far side defects measured with different velocities
Dane BadawczeThe dataset contains raw signals measured with the use of the magnetic flux leakage (MFL) technique. Linear Hall effect sensors A1324 were used to measure magnetic flux leakage. Three voltage signals were measured: Bx sensor output, Bz1 sensor output, and difference of Bz1 and Bz2 outputs. An output of a Bx sensor was directly proportional to the tangential...
-
Spin-glass behavior in a binary Pr 3 Ir intermetallic compound
PublikacjaPolycrystalline Pr3Ir was synthesized by arc melting. Its cementite-type crystal structure (Pnma) was confirmed by powder X-ray diffraction and estimated lattice parameters are in agreement with literature. Physical properties were measured by means of the ac and dc magnetic susceptibility, electrical resistivity and heat capacity. Our results indicate spin-glass behavior in Pr3Ir with a freezing temperature Tf = 6.58 K and activation...
-
Magnetic properties of α-KCoPO4 compound with a chiral polar crystal structure
PublikacjaWe have obtained polycrystalline samples of a metastable α variant of KCoPO4 by low temperature (350–400 °C) solid state metathesis reaction of potassium oxalate and ammonium cobalt orthophosphate. The material crystallizes in a polar chiral structure (sg. P63, no. 173). Measurements of magnetic properties reveal antiferromagnetic interactions and no ordering observed down to T = 1.9 K, well below the Weiss temperature |Θcw| =...
-
Absence of superconductivity in fluorine-doped neptunium pnictide NpFeAsO
PublikacjaX-ray diffraction, specific heat, magnetic susceptibility and inelastic x-ray scattering measurements on the transurarium oxypnictides NpFeAsO and NpFeAsO0.85F0.15 are presented. No superconductivity down to 2 K was observed upon fluorine doping, contrary to the structurally analogous rare-earth pnictides. No modification of the phonon density of states was observed upon doping with fluorine. We discuss our results in light of...
-
Optimization of vortex-assisted hydrophobic magnetic deep eutectic solvent-based dispersive liquid phase microextraction for quantification of niclosamide in real samples
PublikacjaIn this manuscript, a green and fast vortex-assisted hydrophobic magnetic deep eutectic solvent-based dispersive liquid phase microextraction (VA-HMDES-DLPME) method was developed for the selective extraction and determination of niclosamide in read samples, including rice, medicine tablets, and water samples. Here, hydrophobic magnetic deep eutectic solvents were used as the extracting solvent without requiring any centrifugation...
-
Superconductivity and appearance of negative magnetocaloric effect in Ba1–xKxBiO3 perovskites, doped by Y, La and Pr
PublikacjaRecently, substantial attention is given to the bismuth-based perovskites for variety of electronic applications. The perovskites are used for quantum dots displays (QLED), photovoltaic systems and superconducting (HTS) devices. In this paper comprehensive studies of Ba1–xKxBi1–yREyO3 bismuth perovskites (REBKBO, RE = Y , La or Pr) are reported. Apart from structural anomalous behavior at low temperatures, the electronic properties...
-
Ring thruster - a preliminary optimisation study of ferrofluid seal and propeller
PublikacjaThe article reports the course of preliminary examination of a ferrofluid seal applied in liquid environment.A newly built research rig is described, and results of pressure tests performed for different shaft rotationsare discussed. Other studies carried out in the past only referred to the gas environment, while the presentexamination aims at finding an answer to the question whether magnetic liquids can be successfully used...
-
Cross-border transmission line configuration influence on the electrical power and energy billing process
PublikacjaIn 2015 a connection between the Polish and Lithuanian power systems become fully operational. The connection consists of a 400 kV double circuit transmission line and a back-to-back HVDC substation located on the Lithuanian side. A magnetic couplings between the circuits of the transmission line cause that during power transmission a different values of active power losses are observed in both circuits. This situation may cause...
-
Multi-Transformer Flyback Converter for Supplying Isolated IGBT and MOSFET Drivers
PublikacjaA multi transformer flyback converter topology for supplying transistor drivers is presented. The topology presents some advantages over typical multi output single transformer, as reduction of effective leakage inductance, equal magnetic coupling between primary and secondary circuits and better isolation between outputs. Simulation study carried out in the LTSpice IV program and preliminary experimental results indicate high...
-
Hysteresis modelling of a medium frequency single-phase transformer
PublikacjaThe article describes a feedback Preisach hysteresis model equivalent circuit implementation of a medium frequency single-phase transformer being a part of a high power and high efficiency DC-DC converter. The macroscopic models of magnetic hysteresis are introduced and the feedback Preisach model is selected for further analysis. The hysteresis model is developed for a prototype transformer and the hysteresis loops are compared...
-
Investigation of magnetic order in a new intermetallic compound Nd2PtGe3
PublikacjaIn the present study we report a successful synthesis of the new intermetallic compound Nd2PtGe3 by an arc-melting method. The powder X-ray diffraction analysis indicates that this compound crystallizes in an disordered variant of the AlB2-type structure (space group P6/mmm, no. 191) with lattice parameters a = 4.2455 Å and c = 4. 1933 Å. The compound exhibits a cluster-glass transition below Tf = 2.9 K, characterized through ac...
-
Improved methods for stator end winding leakage inductance calculation
PublikacjaCalculating the stator end-winding leakage inductance, taking into account the rotor, is difficult due to the irregular shape of the end-winding. The end-winding leakage may distribute at the end of the active part and the fringing flux of the air gap. The fringing flux belongs to the main flux but goes into the end-winding region. Then, not all the magnetic flux occurring in the end region is the end-winding leakage flux. The...
-
Improved cytotoxicity and preserved level of cell death induced in colon cancer cells by doxorubicin after its conjugation with iron-oxide magnetic nanoparticles
PublikacjaA promising strategy for overcoming the problem of limited efficacy in antitumor drug delivery and in drug release is the use of a nanoparticle-conjugated drug. Doxorubicin (Dox) anticancer chemotherapeutics has been widely studied in this respect, because of severe cardiotoxic side effects. Here, we investigated the cytotoxic effects, the uptake process, the changes in cell cycle progression and the cell death processes in the...
-
Selected dynamic properties of adaptive proportional observer of induction motor state variables
PublikacjaThis paper presents problems related to the design and the stability of adaptive proportional observer which is used for estimation of magnetic flux and motor speed in sensorless control systems of induction motor. The gain matrix of the observer was chosen by genetic algorithm and alternatively by pole placement method. It has been shown that adaptive proportional observer is stable if the...
-
Determination of leakage inductances of multi-winding and single-phase transformer
PublikacjaThis paper presents the method for determination of leakage inductances of single-phase and multi-winding transformer. The matrix of leakage inductances takes into account leakage self and also leakage mutual magnetic couplings. It is assumed that there is a flux common to all windings and several leakage fluxes referred to a particular winding. The flux linkages of each coil needed fo calculation of leakage inductances was computed...
-
Influence of intermixing at the Ta/CoFeB interface on spin Hall angle in Ta/CoFeB/MgO heterostructures
PublikacjaWhen a current is passed through a non-magnetic metal with strong spin-orbit coupling, an orthogonal spin current is generated. This spin current can be used to switch the magnetization of an adjacent ferromagnetic layer or drive its magnetization into continuous precession. The interface, which is not necessarily sharp, and the crystallographic structure of the nonmagnetic metal can both affect the strength of current-induced...
-
Iridium 5d -electron driven superconductivity in ThIr3
PublikacjaA polycrystalline sample of superconducting ThI r 3 was obtained by arc-melting Th and Ir metals. Powder x-ray diffraction revealed that the compound crystalizes in a rhombohedral crystal structure (R-3m, s.g. #166) with the lattice parameters: a = 5.3394 ( 1 ) Å and c = 26.4228 ( 8 ) Å . Normal and superconducting states were studied by magnetic susceptibility, electrical resistivity, and heat capacity measurements. The results...
-
New nanoadsorbent based on magnetic iron oxide containing 1,4,7,10-tetraazacyclododecane in outer chain (Fe3O4@SiO2-cyclen) for adsorption and removal of selected heavy metal ions Cd2+, Pb2+, Cu2+
PublikacjaMagnetic Fe3O4@SiO2-cyclen nanoparticles were prepared and used as adsorbent for Cd2+, Pb2+ and Cu2+ from aqueous solution removal process controlled with differential pulse anodic stripping voltammetry (DPASV) and hanging mercury drop electrode (HDME). Nanomaterial was synthesised in three-step process co-precipitation of Fe3O4 core, coating with silane and N-(3-(triethoxysilyl)propyl)-1,4,7,10-tetraazacyclododecane-1-carboxamide...
-
Nanodiamonds Doped with Manganese for Applications in Magnetic Resonance Imaging
PublikacjaNanodiamonds (NDs) are emerging with great potential in biomedical applications like biomarking through fluorescence and magnetic resonance imaging (MRI), targeted drug delivery, and cancer therapy. The magnetic and optical properties of NDs could be tuned by selective doping. Therefore, we report multifunctional manganese-incorporated NDs (Mn-NDs) fabricated by Mn ion implantation. The fluorescent properties of Mn-NDs were tuned...