Search results for: BATTERY
-
Performance of Passive and Active Balancing Systems of Lithium Batteries in Onerous Mine Environment
PublicationTo use lithium-iron-phosphate battery packs in the supply systems of any electric mining equipment and/or machines, the required conditions of work safety must be met. This applies in particular to coal mines endangered by fire and/or explosion. To meet the spark-safety conditions, the cells (together with the battery management system—BMS) must be isolated from the influence of the environment, and therefore placed in special...
-
Storage electric multiple units on partially electrified suburban railway lines
PublicationThe paper presents possible environmental, energy and economical gains implied by replacing conventional traction vehicles with independent powered electric multiple units (IPEMU) on partially electrified suburban railways. IPEMUs can operate in two modes of power supply – using overhead catenary or onboard battery storage. Appropriate computer simulations were carried out in the Matlab program, indicating the parameters of storage...
-
Exercise bike powered electric generator for fitness club appliances
PublicationA generator powered by a stationary bicycle for the purposes of generating electricity for fitness club appliances is considered. A generator is connected to a stationary bicycle in such a way as the circular rotation of the front wheel rotates the coils of wires inside the generator between the poles of the magnets inside the generator. The resulting Direct Current is channeled to the attached battery bank and converted into different...
-
NEW CONCEPT OF HYBRID PROPULSION WITH HYDROSTATIC GEAR FOR INLAND WATER TRANSPORT
PublicationThe article presents the development of author’s concept of a diesel/hydraulic propulsion system for inland watercraft. Due to specific nature of vessel navigation on rivers, classical propulsion systems with shaft lines can be effectively replaced by systems with hydraulic power transmission. A solution is also presented of a hybrid design with extra electric port having the form of a pumping system driven from a battery of accumulators....
-
Comparison of active proximity radars for the wearable devices
PublicationTwo methods of object position and movement estimation in relation to the user of smart glasses were investigated. An active infrared and ultrasonic methods of the obstacle detection were presented and compared. Application of these methods depend on active transducers type (physical medium used), geometry and surface properties of detected objects and their movement direction and speed. In the article properties of both detectors...
-
Wireless multimodal localization sensor for industrial applications
PublicationThis paper presents the concept and design of a wireless multimodal localization sensor for hybrid localization systems combining vision-based, radio-based and inertial techniques in order to alleviate problems in harsh and complex industrial environments. It supports two radio technologies, 868 MHz UHF RFID and 2.4 GHz WSN, for positioning purposes and communications. The sensor includes LED light transmitters for vision-based...
-
Poly(hydroxybutyrate-co-hydroxyvalerate) as a biodegradable binder in a negative electrode material for lithium-ion batteries
PublicationIn this work, graphite-based negative electrode for lithium-ion battery consisting a novel and biodegradable binder poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) is compared with standard graphite electrode with polyvinylidene fluoride (PVDF) as a binder. The rate and cycling performance of lithium ion insertion/extraction of electrodes with PHBV in a half-cell configuration are evaluated. Moreover, on the basis of the electrochemical...
-
Long-Term Measurement of Physiological Parameters – Child Dataset
PublicationThe dataset titled “Long-term measurement of physiological parameters – child is one dataset” of the bigger series named Long-term measurement of physiological parameters. The dataset contains physiological parameter measurements such as skin temperature and resistance, blood pulse, as well as the stress detection marker, which can have a value of 0 when there is no stress detected or 1 when stress appeared. Additionally, the dataset...
-
Influence of Operation Conditions on Temperature Hazard of Lithium-Iron-Phosphate (LiFePO4) Cells
PublicationThe article presents and discusses the results of research on hazard, especially temperature, for selected lithium-ion-phosphate cells operated in accordance with the manufacturer’s recommendations but used under onerous mining conditions. This applies to the performance of cells in battery sets without the application of any management system (BMS). On the basis of the obtained test results, first of all, the influence of the...
-
Wireless Charging Station Design for Electric Scooters: Case Study Analysis
PublicationThis study proposes an example of a wireless charging station design for a small-scale vehicle available on the market. The article analyzes basic transmitter inverter topologies and their compensation methods in terms of flexibility of control, tolerance to uncertainty in positioning, and the possibility of decreasing the integration price. Our comprehensive analysis focuses on the battery voltage range, energy capacity, cost,...
-
Rate performance of (NH4)2V10O25·8H2O as cathode material in Li-ion batteries
Open Research DataThe DataSet contains the galvanostatic charge/discharge curves of the ammonium vanadate nanostructures obtained by the hydrothermal method under an initial pressure of 50 bar ((NH4)2V10O25·8H2O). The battery tests of the samples were performed using the ATLAS 0961 MBI multichannel battery testing system with different current densities in the voltage...
-
Rate performance of mixture (NH4)2V6O16 and (NH4)2V10O25·8H2O as cathode material in Li-ion batteries
Open Research DataThe DataSet contains the galvanostatic charge/discharge curves of the ammonium vanadate nanostructures obtained by the hydrothermal method without initial pressure (mixture (NH4)2V6O16 and (NH4)2V10O25·8H2O). The battery tests of the samples were performed using the ATLAS 0961 MBI multichannel battery testing system with different current densities...
-
HYBRID ENERGY SYSTEM FOR A CLASSIC SHIP POWER PLANT
PublicationThe article presents a brief overview of hybrid energy systems used on ships. The area of their application is outlined. The benefits of using such systems are also indicated. Then, the classic ship power plant is defined. The most important part of the article is a proposal how to modify a classic engine room by using a hybrid energy system. The idea is: to accumulate a part of electricity in areas where it is allowed to burn...
-
Estimation of the Regenerative Braking Process Efficiency in Electric Vehicles
PublicationIn electric and hybrid vehicles, it is possible to recover energy from the braking process and reuse it to drive the vehicle using the batteries installed on-board. In the conditions of city traffic, the energy dissipated in the braking process constitutes a very large share of the total resistance to vehicle motion. Efficient use of the energy from the braking process enables a significant reduction of fuel and electricity consumption...
-
Magazynowanie energii elektrycznej i gospodarka wodorowa
PublicationW artykule dokonano przegl ą du aktualnych technologii magazynowania energii elektrycznej oraz zestawiono uzyskiwane parametry w aspekcie zastosowa ń w zasobnikach systemowych. Przedstawiono studium mo ż liwo ś ci magazynowania energii z odnawialnych ź róde ł energii (O Ź E) w zasobnikach akumulatorowych i elektrowniach szczytowo-pompowych w Polsce. Omówiono tak ż e mo ż liwo ś ci wykorzystania...
-
Excitation-independent constant conductance isfet driver
PublicationA new constant conductance driver for ISFETs sensors has been developed. The proposed circuit maintains the sensor operating point at constant drain-source conductance. The combination of a simple, self-balancing resistance bridge and the subtraction half (or similar fraction) of source-drain voltage from the gate-source voltage provides the independence of output signal from current and voltage drivers instability. The use of...
-
Robust identification of quadrocopter model for control purposes
PublicationThe paper addresses a problem of quadrotor unmanned aerial vehicle (so-called X4-flyer or quadrocopter) utility model identification for control design purposes. To that goal the quadrotor model is assumed to be composed of two abstracted subsystems, namely a rigid body (plant) and four motors equipped with blades (actuators). The model of the former is acquired based on a well-established dynamic equations of motion while the...
-
Determination of Sodium Ion Diffusion Coefficient in Tin Sulfide@Carbon Anode Material Using GITT and EIS Techniques
PublicationThe electroanalytical behavior of SnSx (x = 1, 2) encapsulated into a carbon phase was studied using the galvanostatic intermittent titration technique (GITT) and electrochemical impedance spectroscopy (EIS). These techniques are widely utilized in battery systems to investigate the diffusion of alkali metal cations in anode and cathode materials depending on the concentration of ions in the host material. Here, we report different...
-
Simulation of the Dynamics of Renewable Energy Sources with Energy Storage Systems
PublicationThe intermittency of renewable energy sources (RES) constitutes a challenge for effective power system control. Fossil-fuel-based units offering ancillary power services to meet the short-term power imbalance are a financial and environmental burden for the society. Energy storage systems (ESS) can be the solution in view of the electricity market development and growing environmental concern. The major questions are, in what circumstances...
-
Number of registered BEV and PHEV vehicles in 2011-2016 (in thousands)
Open Research DataThere are three main types of vehicles that are generally regarded as an electric car. These include:
-
An interactive system for remote modeling and design validation of hybrid photovoltaic systems
PublicationIn the paper a multi-functional demonstrator of the interactive system designed to modeling, monitoring and validation of hybrid photovoltaic systems assisted by fuel cells and thermoelectric generators is presented. The purpose of this paper is to report the system solution expressed in the form of a block diagram. Technical parameters of demonstrator components such as: silicon photovoltaic modules, fuel cells, thermoelectric...
-
Li nucleation on the graphite anode under potential control in Li-ion batteries
PublicationApplication of Li-ion batteries in electric vehicles requires improved safety, increased lifetime and high charging rates. One of the most commonly used intercalation anode material for Li-ion batteries, graphite, is vulnerable to Li nucleation, a side reaction which competes with the intercalation process and leads to loss of reversible capacity of the battery, ageing and short-circuits. In this study, we deploy a combined grand...
-
Comparing Apples and Oranges: A Mobile User Experience Study of iOS and Android Consumer Devices
PublicationWith the rapid development of wireless networks and the spread of broadband access around the world, the number of active mobile user devices continues to grow. Each year more and more terminals are released on the market, with the smartphone being the most popular among them. They include low-end, mid-range, and of course high-end devices, with top hardware specifications. They do vary in build quality, utilized type of material,...
-
Dynamic charging of electric buses
PublicationDespite the continuous development of electrochemical battery technology and the multitude of electric buses on offer, it is still not possible to exploit electric buses in urban transport on an all-day basis without the necessity of charging them. It is therefore necessary to build point-to-point contact charging stations or induction charging stations at the terminals. This results in substantial financial outlays connected with...
-
Development of trolleybus public transport in Gdynia as part of sustainable mobility strategy
PublicationIn many EU cities trolleybuses are experiencing a period of revitalization. New lines, new and modern trolley-buses, the use of auxiliary propulsion battery, eco-logical values and others, create great opportunities for that kind of public transport as an effective tool to shape transport policy in accordance with the principles of sustainable mobility. Gdynia is one of three cities in Poland with trolleybuses public transport...
-
Intracranial electrophysiological recordings from the human brain during memory tasks with pupillometry
PublicationData comprise intracranial EEG (iEEG) brain activity represented by stereo EEG (sEEG) signals, recorded from over 100 electrode channels implanted in any one patient across various brain regions. The iEEG signals were recorded in epilepsy patients (N=10) undergoing invasive monitoring and localization of seizures when they were performing a battery of four memory tasks lasting approx. 1 hour in total. Gaze tracking on the task...
-
Unidirectional DC/DC Converter with Voltage Inverter for Fast Charging of Electric Vehicle Batteries
PublicationThe paper proposes the adaptation of the industrial plant’s power network to supply electric vehicle (EV) fast-charging converters (above 300 kW) using renewable energy sources (RESs). A 600 V DC microgrid was used to supply energy from RESs for the needs of variable speed motor drives and charging of EV batteries. It has been shown that it is possible to support the supply of drive voltage frequency converters (VFCs) and charging...
-
The occurence and diagnosis of biomarkers of ethyl alcohol consumption
PublicationEthyl alcohol is a legal and a widely available psychoactive drug. However, its excessive consumption causes addiction. This leads to aggressive behaviors, family battery, difficulties in interpersonal relations, legal offences, suicides, car accidents and deterioration in labor productivity, what causes financial problems. Despite many social actions against alcohol consumption, this problem is still unresolved. Therefore, fast...
-
Optoelectronic device for hematocrit measurements
PublicationAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Study on effective front region thickness of PCM in thermal energy storage using a novel semi-theoretical model
PublicationThermal energy storage in mobile applications, particularly battery of electric vehicles, is currently gaining a lot of importance. In this paper, a semi-theoretical time-dependent mathematical model of the phase change in a double shell thermal energy storage module has been developed where the inner tube is a heat exchange surface. An effective front region thickness for the melting and solidification process has been studied....
-
Alkohol-społeczny problem XXI wieku. Zastosowanie biowskaźników spożywania alkoholu w diagnostyce medycznej.
PublicationAlkohol etylowy jest legalną i ogólnodostępną substancją o działaniu psychoaktywnym. Spożywany w niewielkich ilościach może pozytywnie wpływać na zdrowie, ale jego nadmierna konsumpcja powoduje silne uzależnienie. Może być to przyczyną agresywnych zachowań, przemocy w rodzinie, problemów w kontaktach z ludźmi, problemów z prawem, samobójstw, wypadków samochodowych oraz problemów finansowych. Dlatego też, szybka i jednoznaczna diagnostyka...
-
FPGA-Based Implementation of Real Time Optical Flow Algorithm and Its Applications for Digital Image Stabilization
PublicationAn efficient simplification procedure of the optical flow (OF) algorithm as well as its hardware implementation using the field programmable gate array (FPGA) technology is presented. The modified algorithm is based on block matching of subsets of successive frames, and exploits one-dimensional representation of subsets as well as the adaptive adjustments of their sizes. Also, an l1-norm-based correlation function requiring no...
-
Partially Isolated Multi-Active Bridge DC-DC Converter with Bidirectional EV Charging Ports
PublicationThere is a growing interest in multiport converters due to their ability to interconnect various energy sources and loads using reduced number of components. Regarding electric vehicle (EV) chargers connection, existing multiport solutions either lack scalability, featuring only one isolated charging port or the operation of ports depend on each other, complicating the converter control algorithm. This article proposes a partially...
-
Silicon oxycarbide-tin nanocomposite derived from a UV crosslinked single source preceramic precursor as high-performance anode materials for Li-ion batteries
PublicationIn this work, we report an innovative and facile UV light-assisted synthesis of a nanocomposite based on silicon oxycarbide (SiOC) and tin nanoparticles. SiOC ceramic matrix, containing a conductive free carbon phase, participates in lithium-ion storage, and buffers the volume changes of Li-alloying/de-alloying material. The reported synthesis procedure through a polymer-derived ceramic route involves the preparation of a single-source...
-
Ensuring sustainable development of urban public transport: A case study of the trolleybus system in Gdynia and Sopot (Poland)
PublicationElectromobility is a vital tool in reducing the environmental impact of transportation. A technologically mature means of public transport is the trolleybus. Based on a case study of the Polish cities of Gdynia and Sopot, this paper explores the factors that influence the development of the trolleybus system. Recent developments of in-motion charging (IMC) technology are analysed what provides a new analytical framework for the...
-
Low-Power WSN System for Honey Bee Monitoring
PublicationThe paper presents a universal low-power system for biosensory data acquisition in scope of bees monitoring. We describe the architecture of the system, energy-saving components as well as we discuss the selection of used sensors. The work focuses on energy optimization in a scope of wireless communication. A custom protocol was implemented, which is the basis for presented energy-efficient devices. Data exchange process during...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_004)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_005)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0010)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_002)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0012)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_008)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_003)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_007)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_006)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0011)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_009)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0017)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0021)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0020)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...