displaying 1000 best results Help
Search results for: SCANNING PROBE MICROSCOPY
-
The microstructure of AA5754 alloy under corrosion in alkaline media (pH=11) with 4.5 mM of various carboxylic acids
Open Research DataThis dataset contains scanning electron microscopy (SEM) micrographs taken for polished aluminum AA5754 alloy samples, exposed for 100 min in bicarbonate buffer (pH=11) with the addition of 4.5 mM of carboxylic acids, namely: citric acid, malic acid, maleic acid, succinic acid, tartaric acid, tricarballylic acid and serine. The goal of this study was...
-
The effect of cobalt addition on the corrosion behavior of near equiatomic NiTi shape memory alloy in normal saline solution, impedance and microscopic studies
Open Research DataThe electrochemical and corrosion (uniform and localized) behavior of a binary Ni52Ti48 shape memory alloy (SMA) and two ternary Ni52Ti48-xCox (x = 1.5 and 4.0 wt.%) SMAs were studied. Measurements were conducted in 0.9% NaCl solution at 37 oC. This dataset contains the results of electrochemical impedance spectroscopy (EIS) studies done on daily basis...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer Du-145 cells
Open Research DataThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer Du-145 cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal MRC-5 cells
Open Research DataThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal MRC-5 cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
SEM micrographs of the austenitic stainless steel corrosion in asphalt fumes
Open Research DataThe dataset contains the scanning electron microscopy (SEM) studies of the austenitic stainless steels: AISI 304, AISI 316, AISI 321 and duplex stainless steel AISI 2205. The samples were polished and exposed to the installation carrying asphalt fumes at elevated temperatures (approx. ~210-240 Celsius). The exposition duration was three months. Some...
-
Statistics of AFM current-voltage curves
Open Research DataMapping surface electrical conductivity offers enormous cognitive possibilities regarding the structure and properties of modern materials. The technique invented for this purpose (Conductive AFM) by Murrel's team and colleagues allows independent monitoring of the local conductivity of materials in correlation with the topographic profile. The mentioned...
-
Images revealing the effect of local femtosecond laser ablation of conductive poly(lactic acid) 3D printed electrodes
Open Research DataThe dataset reveals the images of the femtosecond laser (FSL) ablation at the surface of commercially available carbon black-filled poly(lactic acid) 3D printed electrode. The process is used for the increase of the charge transfer of this electrode in electrochemical studies.
-
Gold nanocubic structures agglomeration when put on conductive surfaces
Open Research DataThis dataset contains SEM images of gold nanocubes (AuNC), which were deposited at the conductive Si wafer surface and dried. The deposition method, the solvent used and AuNC concentration have a significant influence on the homogeneous distribution and their agglomeration at the surface, further influencing the electrochemical characteristics of the...
-
SEM micrographs of aluminium corrosion in alkaline media with various bee products as corrosion inhibitors
Open Research DataThis dataset contains various scanning electron microscopy (SEM) micrographs of AA5754 aluminum alloy samples exposed to the corrosive alkaline environment without and with the addition of various bee products to act as green corrosion inhibitors. The products are bee pollen, honey, and putty. They were investigated in bicarbonate buffer (pH =10 or...
-
Microscopic examination of the texture of paper products
Open Research DataAtomic force microscopy (AFM) can be used to study the state of the paper fibers with the aim of providing qualitative and semi-quantitative information on degradation and aging. The work [1] reports the results of tests of various paper products subjected to deliberate aging processes under the influence of various factors. Chemical and biological...
-
SEM micrographs of diamond-phase (sp3-C) rich boron-doped carbon nanowalls (sp2-C)
Open Research DataThis dataset contains the Scanning Electron Microscopy (SEM) micrographs taken for rich boron-doped carbon nanowalls structures, with different boron addition during the synthesis process and different CVD synthesis duration. The [B]/[C] ratios in the plasma were set to 0k, 1.2k, 2k and 5k ppm. The time of growth was ranging between 4 and 9 hours. This...
-
The influence of microstructure on the corrosion resistance for some titanium-based alloys
Open Research DataThis dataset contains scanning electron microscopy (SEM) micrographs revealing the microstructure of some Ti-based alloys, namely: Ti-6Al-4V (file name: TiV), Ti-6Al-7Nb (file name: TiNb) and TC21 (file name: TiAlSnZrMoCrNbSi) alloys and their localized corrosion as a result of passive layer breakdown in a corrosive environment, ie. 0.9% NaCl solution...
-
Gold nanocubic structures agglomeration when put on conductive surfaces
Open Research DataThis dataset contains SEM images of gold nanocubes (AuNC), which were deposited at the conductive Si wafer surface and dried. The deposition method, the solvent used and AuNC concentration have a significant influence on the homogeneous distribution and their agglomeration at the surface, further influencing the electrochemical characteristics of the...
-
Exemplary AFM application in cosmetology
Open Research DataAtomic force microscopy can be used in the diagnosis of the condition of human tissues such as skin, nails and hair. This is obviously related to the use of a variety of cosmetic products and can be understood as an attempt to assess their long-term impact on human appearance and health. An example may be the studies presented in [1] indicating the...
-
AFM and SSRM investiagtion of carbon nanowalls properties
Open Research DataStructures with limited dimensionality are of great interest in modern nanotechnology. The properties of these objects are used, among others, for the construction of modern displays or as a base for quantum computers. Carbon nanowalls, which are the subject of the imaging results contained in this collection, are also considered interesting building...
-
Gold nanocubic structures agglomeration when put on conductive surfaces
Open Research DataThis dataset contains SEM images of gold nanocubes (AuNC), which were deposited at the conductive Si wafer surface and dried. The deposition method, the solvent used and AuNC concentration have a significant influence on the homogeneous distribution and their agglomeration at the surface, further influencing the electrochemical characteristics of the...
-
Morphology and structure of ammonium vanadates synthesis by hydrothermal method
Open Research DataThe DataSet contains the XRD patterns, FTIR spectra, and scanning electron microscopy (SEM) micrographs of ammonium vanadates synthesis by hydrothermal method from different NH4VO3 precursors. The results reveal that a mixture of (NH4)V4O10xH2O and(NH4)0.76V4O10 was obtained for both precursors, however the contribution of each phase was different for...
-
The mechanism of internalization study of QDgreen−CD−FA−C−2028 conjugate at IC80 value to cancer (H460, Du-145, and LNCaP) and normal (MRC-5 and PNT1A) cells
Open Research DataThe influence of different endocytosis inhibitors on the internalization of QDgreen−CD−FA−C−2028 conjugate at IC80 value in cancer (H460, Du-145, and LNCaP) and normal (MRC-5 and PNT1A) cells. First, the cells were preincubated with: drug-free medium (no inhibitor), at 4 °C, 5 µM Cytochalasin D, 30 µM Amiloride, 80 µM Dynasore, 25 µM Pitstop 2 and 1.5...
-
Transport of Particles in Intestinal Mucus under Simulated Infant and Adult Physiological Conditions: Impact of Mucus Structure and Extracellular DNA
PublicationThe final boundary between digested food and the cells that take up nutrients in the small intestine is a protective layer of mucus. In this work, the microstructural organization and permeability of the intestinal mucus have been determined under conditions simulating those of infant and adult human small intestines. As a model, we used the mucus from the proximal (jejunal) small intestines of piglets and adult pigs. Confocal...
-
The impact of QDgreen, QDgreen−β−CD−FA, β−CD, C−2028, β−CD(C−2028), QDgreen−C−2028, and QDgreen−β−CD(C−2028)−FA nanoconjugates on lysosomal content in the cancer (H460, Du-145, LNCaP) and normal (MRC-5, PNT1A) cells
Open Research DataThe impact of QDgreen, QDgreen−β−CD−FA, β−CD, C−2028, β−CD(C−2028), QDgreen−C−2028, and QDgreen−β−CD(C−2028)−FA nanoconjugates on lysosomal content in the cancer (H460, Du-145, LNCaP) and normal (MRC-5, PNT1A) cells was performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). To explore the influence...
-
Topography and microstructure of phosphate-iron glasses containing niobium and titanium
Open Research DataThe topography and microstructure of phosphate-iron glasses containing niobium and titanium were investigated by the means of X-ray diffraction (XRD), scanning electron microscopy (SEM). Glass samples of the composition of 35P2O5-30Fe2O3-(35-x)Nb2O5-xTiO2 where x= 0; 7.5 and 15 (in %mol) were prepared by the conventional melt quenching technique. Appropriate...
-
EH36 steel for shipbuilding - fracture SEM investigation (plate thicnkness 30mm), a0/W = 0.6
Open Research DataThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding - fracture SEM investigation (plate thicnkness 30mm), a0/W = 0.5
Open Research DataThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
New, fast and cheap prediction tests for BRCA1 gene mutations identification in clinical samples.
PublicationDespite significant progress in cancer therapy, cancer is still the second cause of mortality in the world. The necessity to make quick therapeutic decisions forces the development of procedures allowing to obtain a reliable result in a quick and unambiguous manner. Currently, detecting predictive mutations, including BRCA1, is the basis for effectively treating advanced breast cancer. Here, we present new insight on gene mutation...
-
2024 Microscopy in Environmental Monitoring
e-Learning CoursesThe online repository will be used to teach students by presenting them lectures about variable aspects of microscopy techniques used in environmental monitoring.
-
MICROSCOPY AND MICROANALYSIS
Journals -
A BODIPY‐Based Molecular Rotor in Giant Unilamellar Vesicles: A Case Study by Polarization‐Resolved Time‐Resolved Emission and Transient Absorption Spectroscopy
PublicationBODIPY and BODIPY-derived systems are widely applied as fluorophores and as probes for viscosity detection in solvents and biological media. Their orientational and rotational dynamics in biological media are thus of vital mechanistic importance and extensively investigated. In this contribution, polarization-resolved confocal microscopy is used to determine the orientation of an amphiphilic BODIPY-cholesterol derivative in homogeneous...
-
Results after grinding C45 steel
Open Research DataThe database contains results from nanoindenter, scanning microscope and also X-ray diffractometer. To determine the residual stresses and the size of the crystallites in the ferrite grains in the grinded surface layer, the Williamson Hall analysis of the X-ray diffraction patterns was performed. XRD diffraction patterns were also used to perform a...
-
2022 MICROSCOPY IN ENVIRONMENTAL MONITORING -lecture - Nowy
e-Learning CoursesThe online repository will be used to teach students by presenting them lectures about variable aspects of microscopy techniques used in environmental monitoring.
-
Microscopy
Journals -
Fabrication and characterization of boron-doped nanocrystalline diamond-coated MEMS probes
PublicationFabrication processes of thin boron-doped nanocrystalline diamond (B-NCD) films on silicon-based micro- and nano-electromechanical structures have been investigated. Nanocrystalline boron doped -diamond (B-NCD) films were deposited using Microwave Plasma Assisted Chemical Vapour Deposition (MW PA CVD) method. The variation of B-NCD morphology, structure and optical parameters were particularly investigated. The use of truncated...
-
3D Acoustic Field Intensity Probe Design and Measurements
PublicationThe aim of this paper is two-fold. First, some basic notions on acoustic field intensity and its measurement are shortly recalled. Then, the equipment and the measurement procedure used in the sound intensity in the performed research study are described. The second goal is to present details of the design of the engineered 3D intensity probe, as well as the algorithms developed and applied for that purpose. Results of the intensity...
-
APPLYING RANSAC ALGORITHM FOR FITTING SCANNING STRIPS FROM AIRBORNE LASER SCANNING
PublicationDuring the development of the data acquired by airborne laser scanning the important issue is the fitting and georeferencing of ALS point clouds by means of the tie surfaces and the reference planes. The process of scanning strips adjustment is based on mutual integration of point clouds (scanning strips) and their adaptation to the reference planes.In simultaneous adjustment all strips are combined into one geometrically coherent...
-
Noble metal modified TiO2 microspheres: Surface properties and photocatalytic activity under UV-vis and visible light
PublicationComposite photocatalysts that consist of TiO2and noble metal nanostructures have been considered tobe the promising and pivotal material for accessible enhancement of the efficiency in the photocatalyticprocess carried out in the aqueous and gas phases. In this work we fabricated porous TiO2microspheresthrough a hydrothermal process followed by photochemical reduction of noble metal nanoparticles atthe TiO2surface. The morphology...
-
Preparation, characterization and photocatalytic activity of TiO2 microspheres decorated by bimetallic nanoparticles
PublicationComposite photocatalysts that consist of TiO2and noble metal nanostructures have been considered tobe the promising and pivotal material for accessible enhancement of the efficiency in the photocatalyticprocess carried out in the aqueous and gas phases. In this work we fabricated porous TiO2microspheresthrough a hydrothermal process followed by photochemical reduction of noble metal nanoparticles atthe TiO2surface. The morphology...
-
Development of the sound field 3D intensity probe based on miniature microphones
PublicationThe engineered measuring probe uses three pairs of miniature microphones coupled. The signals from the microphones after an initial amplification are fed to differential circuits. Due to the required symmetry of the circuit it was necessary to select electronic components very carefully. Moreover, additional digital signal processing techniques were applied to avoid amplitude and phase mismatch. The view of the engineered probe...
-
Assessing Highway Travel Time Reliability using Probe Vehicle Data
PublicationProbe vehicle data (also known as “floating car data”) can be used to analyze travel time reliability of an existing road corridor in order to determine where, when, and how often traffic congestion occurs at particular road segments. The aim of the study is to find the best reliability performance measures for assessing congestion frequency and severity based on probe data. Pilot surveys conducted on A2 motorway in Poland confirm...
-
Microscopy methods in nanotechnology
e-Learning Courses -
Microscopy methods in nanotechnology
e-Learning Courses -
Programmatic Simulation of Laser Scanning Products
PublicationThe technology of laser scanning is widely used for producing three-dimensional digital representations of geographic features. The measurement results are usually available in the form of 3D point clouds, which are often used as a transitional data model in various remote sensing applications. Unfortunately, while the costs of Light Detection And Ranging scanners have dropped significantly in recent years, they are still considered...
-
MARITIME LASER SCANNING AS THE SOURCE FOR SPATIAL DATA
PublicationThe rapid development of scanning technology, especially mobile scanning, gives the possibility to collect spatial data coming from maritime measurement platforms and autonomous manned or unmanned vehicles. Presented solution is derived from the mobile scanning. However we should keep in mind that the specificity of laser scanning at sea and processing collected data should be in the form acceptable in Geographical Information...
-
Applied Microscopy
Journals -
The Progress in Electron Microscopy Studies of Particulate Matters to Be Used as a Standard Monitoring Method for Air Dust Pollution
PublicationThe present article reviews studies on air solid particles carried out with the use of electron microscopy. Particle analysis combining scanning and transmission electron microscopy (SEM and TEM) can be used to derive size-resolved information of the composition, mixing state, morphology, and complex refractive index of atmospheric aerosol particles. It seems that electron microscopy is more widely used in atmospheric particulate...
-
Airborne Laser Scanning Point Cloud Update by Used of the Terrestrial Laser Scanning and the Low-Level Aerial Photogrammetry
PublicationLaser scanning technology is a spatial information gathering technique which is commonly used all over the world. Systems where the red-light beam are used, are divided into: terrestrial, mobile and airborne scanning systems. The main differences between those are the accuracy, the data acquisition solution (f. e. in ALS and MLS besides of the laser scanner, the inertial navigation system is required) and the covered area in one...
-
DIFFRACTION PHASE MICROSCOPY FOR OBSERVATION ON RED BLOOD CELLS FLUCTUATION
PublicationNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – RBCs (Red Blood Cells). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations observation...
-
Mobile Laser Scanning Calibration on a Marine Platform
PublicationThe article describes the method of calibration of the Riegl VMZ-400 mobile scanning system on a floating platform and an experiment aimed at conducting measurements from a previously calibrated instrument. The issue of factors affecting the quality of measurements was discussed. Mobile laser scanning is an increasingly popular measurement solution, but it is still innovative on a European scale. The use of a floating platform...
-
Observation on red blood cells fluctuations by diffraction phase microscopy
PublicationNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – Red Blood Cells (RBCs). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations...
-
Triangular 3D Laser Scanning in Underwater Photogrammetry
PublicationThe use of triangular 3D laser scanning may significantly enhance the visual inspection of underwater objects. In these days of high demand for accurate information, exclusively photographic documentation is not enough, as it is geometrically flawed. The authors of this article are trying to present the rudiments of laser scanning, a modern means of measuring, which is reliable, relatively easy to use and works in accordance with...
-
Application of multisine nanoscale impedance microscopy to heterogeneous alloy surface investigations
PublicationIn the recent years atomic force microscopy is recognized as valuable tool for investigation of surficial features of construction materials. It concerns, among other things, studies of changes caused by such phenomena as galvanic corrosion, passivation associated with the growth of oxide layers, or sensitization of austenitic steels with the formation of carbide phases. In addition, atomic forcemicroscopy allows easy coupling...
-
3D Scanning of Semitransparent Amber with and without Inclusions
PublicationThis paper is concerned with making 3D scans of semitransparent ambers with and without inclusions. The paper presents results of using a variety of devices applied for this purpose. Equipment used in the experiments includes a 3D laser scanner, a structured light scanner, a stereo camera, a camera array and a tomograph. The main object used in the experiment was an amber with a fossil of a lizard. The paper shows possibilities...