displaying 1000 best results Help
Search results for: lens-less microscopy
-
Simulations of freshwater lens recharge and salt/freshwater interfaces using the HYDRUS and SWI2 packages for MODFLOW
PublicationThe paper presents an evaluation of the combined use of the HYDRUS and SWI2 packages for MODFLOW as a potential tool for modeling recharge in coastal aquife rs subject to saltwater intrusion. The HYDRUS package for MODFLOW solves numerically the one-dimensional form of the Richards equation describing water flow in variably- saturated media. The code computes groundwater recharge to or...
-
Phase separation in poly(butylene terephthalate)-based materials prepared by solid-state modification
PublicationThe morphology of a series of poly(butylene terephthalate) (PBT)/fatty acid dimer diol (FADD)-based copolyesters prepared by solid-state modi fi cation (SSM) was studied. It was shown that in copolyesters containing less than 10 wt% FADD two different phases, i.e. a PBT crystalline phase and a PBT-rich amorphous phase, are present. The FADD residues were more or less homogeneously distributed throughout the interlamellar regions....
-
Assessment of the impact of bacteria Pseudomonas denitrificans, Pseudomonas fluorescens, Bacillus subtilis and yeast Yarrowia lipolytica on commercial poly(ether urethanes)
PublicationThe assessment of the impact of the bacteria Pseudomonas denitrificans, Pseudomonas fluorescens, Bacillus subtilis and yeast Yarrowia lipolytica on commercial poly(ether urethanes) Tecoflex® and Tecothane® is presented. The polyurethane samples were incubated with pure cultures of the microorganisms at 30 °C for five months. The changes in the chemical structure of the polymers were evaluated using loss of weight and contact angle...
-
Electronic conductivity in the SiO2-PbO-Fe2O3 glass containing magnetic nanostructures
PublicationThe linear impedance spectra of iron–silicate–lead glass samples were measured in the frequency range from 1 MHz to 1 MHz and in the temperature range from 153 K to 423 K. The structure was investigated by means of XRD and atomic force microscopy. Local electrical and magnetic properties of the samples were tested with the aid of electrostatic force microscopy (EFM) and magnetic force microscopy (MFM). The obtained results show...
-
Application of BDD thin film electrode for electrochemical decomposition of heterogeneous aromatic compounds
PublicationThe aim of the presented study is to investigate the applicability of electrochemical oxidation of aromatic compounds containing heteroatoms, e.g. waste from production of pesticides or pharmaceutics, at a borondoped diamond (BDD) electrode. The BDD electrodes were synthesized by microwave plasma enhanced chemical vapour deposition (MW PE CVD). Investigation of the electrode surface by optical microscopy and scanning electron microscopy...
-
Thermal dewetting as a method of surface modification of the gold thin films for surface plasmon resonance based sensor applications
PublicationHere, we report a quick and simple approach with low, optimized production costs to obtain surface plasmon resonance (SPR) based sensors fabricated through a time- and resource-effective method based on thermal dewetting of thin Au films. From the applicative point of view, the method of detection presented here should be easier to implement, since light transmission measurements seem to be much less challenging than light refractive...
-
2024 Microscopy in Environmental Monitoring
e-Learning CoursesThe online repository will be used to teach students by presenting them lectures about variable aspects of microscopy techniques used in environmental monitoring.
-
Application of dynamic impedance spectroscopy to scanning probe microscopy.
PublicationDynamic impedance spectroscopy, designed for measuring nonstationary systems, was used in combination with scanning probe microscopy. Using this approach, impedance mapping could be carried-out simultaneously with topography scanning. Therefore, correlation of electrical properties with particular phases of an examined sample was possible. The sample used in this study was spheroidal graphite cast iron with clearly defined phases...
-
Results after grinding C45 steel
Open Research DataThe database contains results from nanoindenter, scanning microscope and also X-ray diffractometer. To determine the residual stresses and the size of the crystallites in the ferrite grains in the grinded surface layer, the Williamson Hall analysis of the X-ray diffraction patterns was performed. XRD diffraction patterns were also used to perform a...
-
MICROSCOPY AND MICROANALYSIS
Journals -
Assessment of unusual failure in crankshaft of heavy-duty truck engine
PublicationThe unusual premature failure of a heavy-duty truck engine crankshaft has been the subject of a rigorous study, and this manuscript describes it in detail. The failure was happened to begin with the growth of the crack from the surface defects, in the form of the clusters of non-metallic inclusions, in the lubrication hole zone of the first main journal, which was the stress concentration zone. A series of experiments including...
-
Hydrogen Embrittlement and Oxide Layer E ect in the Cathodically Charged Zircaloy-2
PublicationThe present paper is aimed at determining the less investigated effects of hydrogen uptake on the microstructure and the mechanical behavior of the oxidized Zircaloy-2 alloy. The specimens were oxidized and charged with hydrogen. The different oxidation temperatures and cathodic current densities were applied. The scanning electron microscopy, X-ray electron diffraction spectroscopy, hydrogen absorption assessment, tensile, and...
-
Effect of bio-polyol molecular weight on the structure and properties of polyurethane-polyisocyanurate (PUR-PIR) foams
PublicationThe increasing interest in polyurethane materials has raised the question of the environmental impact of these materials. For this reason, the scientists aim to find an extremely difficult balance between new material technologies and sustainable development. This work attempts to validate the possibility of replacing petrochemical polyols with previously synthesized bio-polyols and their impact on the structure and properties...
-
2022 MICROSCOPY IN ENVIRONMENTAL MONITORING -lecture - Nowy
e-Learning CoursesThe online repository will be used to teach students by presenting them lectures about variable aspects of microscopy techniques used in environmental monitoring.
-
Microscopy
Journals -
Morphology, Photocatalytic and Antimicrobial Properties of TiO2 Modified with Mono- and Bimetallic Copper, Platinum and Silver Nanoparticles
PublicationNoble metal nanoparticles (NMNPs) enhanced TiO2 response and extended its activity under visible light. Photocatalytic activity of TiO2 modified with noble metal nanoparticles strongly depends on the physicochemical properties of NMNPs. Among others, the differences in the size of NMNPs seems to be one of the most important factors. In this view, the effect of the metal’s nanoparticles size, type and amount on TiO2 photocatalytic...
-
Compact Electromagnetic Lens Antennas Using Cascaded Metasurfaces for Gain Enhancement and Beam Steering Applications
PublicationElectromagnetic (EM) lens antenna designs using cascaded metasurfaces for gain enhancement and beam steering applications are proposed. Two different lens aperture designs are proposed and populated with aperiodic unit cells of size 0.2λo × 0.2λo. In lens Design 1, the unit cells of different phases are distributed in concentric circular zones, whereas in lens Design 2, the unit cells of different phases are distributed in vertical...
-
Application of Dynamic Impedance Spectroscopy to Scanning Probe Microscopy
Publication -
Sociology Lens
Journals -
Low-Cost 3-D Printed Lens Antenna for Ka-Band Connectivity Applications
PublicationThis paper discusses the use of low-cost 3-D printing technology to fabricate dielectric lenses for Ka-band wireless networks. A low-cost FDM alternative to previously presented 3-D printed lens in SLA technology with high performance resin is presented. The presented approach has been demonstrated for a 39 GHz MU-MIMO antenna array modified to realize multibeam or switched-beam antenna that can support demanding energy-efficient...
-
Pilot-Scale Studies of WO3/S-Doped g-C3N4 Heterojunction toward Photocatalytic NOx Removal
PublicationDue to the rising concentration of toxic nitrogen oxides (NOx) in the air, effective methods of NOx removal have been extensively studied recently. In the present study, the first developed WO3/S-doped g-C3N4 nanocomposite was synthesized using a facile method to remove NOx in air efficiently. The photocatalytic tests performed in a newly designed continuous-flow photoreactor with an LED array and online monitored NO2 and NO system...
-
Electrical properties and structure of lead-borate glass containing iron ions.
PublicationThe ac and dc conductivity in iron–lead-borate glass samples was investigated in the frequency range from 1 mHz to 1 MHz and in the temperature range from 153 K to 423 K. The structure was investigated by the means of atomic force microscopy (AFM) and the crystalline phases (if present) were identified by the means of X-ray diffractometry. Two types of ac electrical behaviour were observed. The first group of glass samples which...
-
Evaluation and rationale of the performance of several elastomeric composites incorporating devulcanized EPDM
Publicationthylene Propylene Diene rubber (EPDM), is present in many applications. However, its crosslinked structure makes difficult its recycling. The use of devulcanized EPDM, (dEPDM) as a component of elastomeric composites, is a real possibility to reuse EPDM scraps. In this study, three matrices (natural rubber (NR), styrene butadiene rubber (SBR) and EPDM rubber) have been tested including devulcanized EPDM as a recycled component....
-
Low-cost 3D Printed Circularly Polarized Lens Antenna for 5.9 GHz V2X Applications
PublicationThis paper presents design and realization of a circularly polarized antenna consisting of a linearly polarized patch antenna and a 3D printed lens, at the same time performing the functions of wave collimator and a polarizer. The antenna is dedicated for 802.11p systems, as a part of road infrastructure, with operation bandwidth 5.85 - 5.925 GHz. Its realised gain and axial ratio at center frequency 5.9 GHz are 14.3 dBi and 2.17...
-
A high-accuracy complex-phase method of simulating X-ray propagation through a multi-lens system
PublicationThe propagation of X-ray waves through an optical system consisting of many X-ray refractive lenses is considered. For solving the problem for an electromagnetic wave, a finite-difference method is applied. The error of simulation is analytically estimated and investigated. It was found that a very detailed difference grid is required for reliable and accurate calculations of the propagation of X-ray waves through a multi-lens...
-
Gender Through the Lens of Culture
Publication -
Gender Through the Lens of Culture
Publication -
Methods and Instruments | Scanning Electrochemical Microscopy
PublicationScanning electrochemical microscopy is based on the recording of electrolysis currents (Faradaic currents) at a microelectrode (ME) probe that is scanned over the sample. Different working modes are available to couple the electrolysis at the ME to reactions at the sample. The article explains their principles and provides examples of their application. The feedback mode, the sample-generation/tip collection mode, the redox-competition...
-
Encapsulation of Amikacin into Microparticles Based on Low-Molecular-Weight Poly(lactic acid) and Poly(lactic acid-co-polyethylene glycol)
PublicationThe aim of this study was to fabricate novel microparticles (MPs) for efficient and long-term delivery of amikacin (AMI). The emulsification method proposed for encapsulating AMI employed low-molecular-weight poly(lactic acid) (PLA) and poly(lactic acid-co-polyethylene glycol) (PLA−PEG), both supplemented with poly(vinyl alcohol) (PVA). The diameters of the particles obtained were determined as less than 30 μm. Based on an in-vitro...
-
Ionogel fibres of bis(trifluoromethanesulfonyl)imide anion-based ionic liquids for the headspace solid-phase microextraction of chlorinated organic pollutants
PublicationIonogels, a family of hybrid materials in which ionic liquids (ILs) are confined in a sol–gel network, are receiving much attention in a variety of scientific and technological fields. In this work, ionogels derived from three different ILs based on the anion bis(trifluoromethanesulfonyl)imide (TFSI), namely 1-butyl- 3-methylpyridinium bis(trifluoromethanesulfonyl)imide ([C4C1Py][TFSI]), 1-butyl-1-methylpyrrolidinium bis(trifluoromethanesulfonyl)imide...
-
Microstructure and mechanical properties of a dissimilar metal welded joint of Inconel 617 and P92 steel with Inconel 82 buttering layer for AUSC boiler application
PublicationThe application of the novel dissimilar metal welded (DMW) joint, utilizing Inconel 617 and P92 steel, was showcased in the advanced ultra-supercritical (AUSC) boiler. The work has been performed to investigate the effect of Inconel 82 (ERNiCr-3) buttering layer on microstructure and mechanical properties (high-temperature tensile strength, impact strength and microhardness) of gas tungsten arc welded (GTAW) dissimilar joint between...
-
Microscopy methods in nanotechnology
e-Learning Courses -
Microscopy methods in nanotechnology
e-Learning Courses -
Oriented Gaussian beams for high-accuracy computation with accuracy control of X-ray propagation through a multi-lens system
PublicationA highly accurate method for calculating X-ray propagation is developed. Within this approach, the propagating wave is represented as a superposition of oriented Gaussian beams. The direction of wave propagation in each Gaussian beam agrees with the local direction of propagation of the X-ray wavefront. When calculating the propagation of X-ray waves through lenses, the thin lens approximation is applied. In this approximation,...
-
Multi-Beam Antenna for Ka-Band CubeSat Connectivity Using 3-D Printed Lens and Antenna Array
PublicationIn this paper, the design of a passive multi-beam lens antenna is proposed for the CubeSat space communication system as an alternative application of a 2-D microstrip antenna array that has originally been designed for a 39 GHz 5 G MU-MIMO system. The half-ellipsoid lens is 3-D printed using stereolithography (SLA) technology. The antenna prototype is capable of selecting the main beam between 16 different directions with a gain...
-
Application of different modes of nanoscale impedance microscopy in materials research
PublicationIn recent years, there is noticeable interest in application of various types of scanning probe microscopy in material science research. One of them is contact atomic force microscopy combined with local impedance measurements, known as nanoscale impedance microscopy. Literature references present its application in investigations of new materials, microelectronics diagnostics, or research of protective coatings performance. In...
-
Applied Microscopy
Journals -
Corrosion Inhibition Mechanism and Efficiency Differentiation of Dihydroxybenzene Isomers Towards Aluminum Alloy 5754 in Alkaline Media
PublicationThe selection of efficient corrosion inhibitors requires detailed knowledge regarding the interaction mechanism, which depends on the type and amount of functional groups within the inhibitor molecule. The position of functional groups between different isomers is often overlooked, but is no less important, since factors like steric hinderance may significantly affect the adsorption mechanism. In this study, we have presented how...
-
DIFFRACTION PHASE MICROSCOPY FOR OBSERVATION ON RED BLOOD CELLS FLUCTUATION
PublicationNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – RBCs (Red Blood Cells). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations observation...
-
Observation on red blood cells fluctuations by diffraction phase microscopy
PublicationNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – Red Blood Cells (RBCs). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations...
-
Application of multisine nanoscale impedance microscopy to heterogeneous alloy surface investigations
PublicationIn the recent years atomic force microscopy is recognized as valuable tool for investigation of surficial features of construction materials. It concerns, among other things, studies of changes caused by such phenomena as galvanic corrosion, passivation associated with the growth of oxide layers, or sensitization of austenitic steels with the formation of carbide phases. In addition, atomic forcemicroscopy allows easy coupling...
-
The new version of contact-less method for localisation of catenary contact wire – theoretical assumption
PublicationThis article presents the theoretical basic of a new version of contact-less method for localising the catenary contact wires, using the advanced video techniques and image analysis. So far, contact line diagnostic systems exploited nowadays uses the contact measuring methods with special design current collector. This solutions make it impossible to measure the contact line geometry in a static way. The proposed measurement method...
-
PHASE OBJECT OBSERVATION SYSTEM BASED ON DIFFRACTION PHASE MICROSCOPY
PublicationIn the paper authors present a special measurement system for observing phase objects. The diffraction phas microscopy makes it possible to measure the dimensions of a tested object with a nanometre resolution. To meet this requirement, it is proposed to apply a spatial transform. The proposed setup can be based either on a two lenses system (called 4 f ) or a Wollaston prism. Both solutions with all construction aspects are described...
-
Fluorescence imaging spectroscopy and microscopy
Publication -
The value of less Light – Sustainable architectural lighting design
PublicationSince its beginning, the art of external illumination has substantially influ-enced the creation and the perception of architecture and the night-time urban environment. In her lecture, the author examines and defines the significant interdisciplinary conditions related to architectural lighting design that have evolved over the years, starting from the first simple exterior lighting projects to the more modern, complex concepts...
-
A Concept for Safe and Less Expensive Acceleration of a Marine Steam Turbine Start-up
PublicationThis paper analyses the issue of accelerated start-up of a marine steam turbine, which is an important problem because the start-up of a steam machine involves the combustion of fuel that is not transformed into useful energy. To find novel technologies that offer improvements in this aspect is essential due to restrictions on reducing ship emissions. Thus, the shorter the start-up time, the better for the environment and economy....
-
Piezoresponse force microscopy and dielectric spectroscopy study of Ba0.6Sr0.4TiO3 thin films
PublicationResearch on synthesis, characterization and determination of processing – structure – property relationships of commercially important ferroelectric thin films has been performed. The sol-gel-type solution deposition technique was applied to produce good quality thin films of Ba0.6Sr0.4TiO3 (BST60/40) chemical composition on the stainless steel substrates. The thin films were characterized in terms of their microstructure, crystal...
-
Development of an Active Optical Lens for Arc Flashing Detection
Publication -
Comparison of PM10 concentration in Gdansk and London using electron microscopy
PublicationParticulate matter (PM) has been considered as one of the most dangerous elements of air pollution. Multiply analytical methods are employed to identify the composition of particles present in the air. The theoretical part of this work is a description of different research centres all over the world where particulate matter is being analyzed using various techniques. The purpose of this project is to analyze and compare particles...
-
MICROSCOPY RESEARCH AND TECHNIQUE
Journals