displaying 1000 best results Help
Search results for: VOLTAGE DOUBLER
-
Distribution Transformer with Multi-Zone Voltage Regulation for Smart Grid System Application
PublicationThe article presents four concepts of the multi-zone voltage regulation (MZVR) system. It is a combination of a distribution transformer with an on-load tap-changer, for step voltage regulation, and a power electronic converter, dimensioned for a fraction of MZVR power, realizing continuous voltage regulation, supplemented by a special switch, the so-called bypass. This allows voltage regulation at high resolution, wide range and...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublicationOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublicationThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublicationThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublicationThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a sea voyage
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a sea voyage.
-
Electrochemical sensor for measurement of volatile organic compounds employing square wave perturbation voltage
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde in air. Sensitivity and limit of quantification of the sensor were determined for different internal electrolyte using the square wave voltammetry (SWV) as a detection technique. The working and counter electrodes were made of platinum. Ionic liquids 1-hexyl, 3-methylimidazolium chloride,1-hexyl, 3-methylimidazolium bis (trifluoromethanesulfonyl)...
-
Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter
PublicationA new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...
-
Voltage and Reactive Power Load Flow Optimization in the Power System Using Fuzzy Logic
PublicationThe paper presents issues related to voltage control in the power system. An original method of reactive power flow optimization is considered, which leads to improved voltages in the power system and reduced active power losses. The optimization method is based on a procedure that employs fuzzy logic and is supported by a gradient search algorithm. The method has been implemented in PLANS software and verified.
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublicationMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
New Alternative Passive Networks to Improve the Range Output Voltage Regulation of the PWM Inverters
Publication -
Impact of power electronic Var compensators installed in certain grid points on the voltage failure
PublicationThe article presents the test results of the various types of static compensators FACTS models in the power system. The basic case, which was analyzed, it was behavior of compensators which are installed in select points of the system during voltage failure. The article presents selected results of studies conducted as part of a work [2].
-
Sensorless control system of induction machine supplied by voltage source inverter with output filter
PublicationThe paper focuses on sensorless control of the induction machines supplied by inverter with the output filters. “The novel” idea of the speed observer which is based on the backstepping approach is shown. The standard structure of the exponential observer is extended by the integrators and additional Z vector. The simulation and experimental results validate the proposed solution.
-
Artificial Neural Network (ANN)-Based Voltage Stability Prediction of Test Microgrid Grid
Publication -
Analysis of inductive power transfer systems for variable air gap and voltage supply frequency
PublicationThe paper describes an IPT system, by which electrical energy may be transmitted through a large air gap between coils without electrical connection. It presents theoretical and simulation analysis of IPT, which allows for supplying a receiver in the conditions of slow, in relation to the dynamics of power supply, changes in dimension of the air gap. The influence of frequency characteristics of the system on the possible selection...
-
Design of hight voltage busbar: trade off between electrical field and stray inductance
PublicationArtykuł dotyczy optymalizacji konstrukcji i technologii szyny doprowadzenia zasilania do pojedynczej gałęzi falownika średniego napięcia. Dla szeregowego układu złożonego z trzech modułów elektroizolowanych (6 par tranzystorów i diod) rozważono warianty geometrii szyny zasilania przy uwzględnieniu wypadkowej indukcyjności obwodu komutacyjnego. Wyznaczono główne składniki indukcyjności rozproszenia oraz wykazano jej wpływ na przepięcia...
-
Random components influence on the values characterising periodic disturbances in low voltage supply lines.
PublicationAnalizowano wpływ składowych losowych na wielkości charakteryzujących zaburzenia okresowe w napięciu zasilania na przykładzie współczynnika zawartości harmonicznych (THD). Zaprezentowano sposób wyznaczania niepewności pomiaru współczynnika THD, uwzględniający występowanie korelacji pomiędzy składową podstawową i kolejnymi harmonicznymi napięcia sieci a także między poszczególnymi harmonicznymi. Przedstawiono analizę wyników z pomiarów...
-
Research of chitosan coatings deposited by electrophoretic deposition method at various voltage and time parameters
PublicationThe aim of this research is to estimate the electrophoretic deposition main parameters, such as voltage and time duration, that will provide optimal characteristics of the surface layer. Chitosan coatings were synthesized on biomedical Ti13Zr13Nb alloys at 20 V and 30 V and with deposit times of 2min, 5 min, 10 min, and 15 min. Evaluation of the coating was performed by using Scanning Electron Microscope (SEM), Energy-Dispersive...
-
Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables
PublicationThis work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC...
-
Study of Nanohydroxyapatite Coatings Prepared by the Electrophoretic Deposition Method at Various Voltage and Time Parameters
PublicationThe aim of the work is to compare the properties of nanohydroxyapatite coatings obtained using the electrophoretic deposition method (EDP) at 10 V, 20 V, and 30 V, and with deposit times of 2 and 5 min. The primary sedimentation was used to minimize the risk of the formation of particle agglomerates on the sample surface. Evaluation of the coating was performed by using a Scanning Electron Microscope (SEM), Energy-Dispersive Spectroscopy...
-
Unidirectional DC/DC Converter with Voltage Inverter for Fast Charging of Electric Vehicle Batteries
PublicationThe paper proposes the adaptation of the industrial plant’s power network to supply electric vehicle (EV) fast-charging converters (above 300 kW) using renewable energy sources (RESs). A 600 V DC microgrid was used to supply energy from RESs for the needs of variable speed motor drives and charging of EV batteries. It has been shown that it is possible to support the supply of drive voltage frequency converters (VFCs) and charging...
-
Frequency measurement research with weight averaging of pulse output signal of voltage-to-frequency converter
PublicationThe paper presents the essence and investigation of the efficiency of weight averaging of a pulse output signal of voltage-to-frequency converter. The effect of counting and the influence of interference on the result of weight averaging of frequency modulated pulses are analyzed. It is shown that from the point of view of counting error reduction, the best are polynomial weight functions. In the case of high interferences whose...
-
Errors in the analysis of series resonant inverter/converter assuming sinusoidal waveforms of voltage and current
PublicationIn this paper the theory and simulation results of the series resonant inverter / converter are presented. In this work the authors carried out a detailed comparative analysis of results obtained using the method of AC analysis in the steady state for the first harmonic with the results of computer simulation. The AC analysis under certain conditions can lead to errors disqualifying this method. In particular, these errors appear...
-
Four level inverter's DC bus voltage balancing with 3-terminal DAB converter
Publication—Multilevel inverters become more and more popular, especially in the medium or high voltage and high power applications. Unfortunately, some of inverter topologies require additional DC bus voltage balancing systems. This paper presents a novel approach to such systems, which is based on a multiple terminal DAB converter. Along with the voltage balancing function the proposed solution enables the connection of energy storage devices...
-
Hybridized Space-Vector Pulsewidth Modulation for Multiphase Two-Level Voltage Source Inverter
PublicationIn space vector pulsewidth modulation (SVPWM) algorithms for multiphase two-level voltage source inverters (VSI), the components of active vectors in all orthogonal spaces have to be calculated within the processor and stored in its memory. These necessitate intensive computational efforts of the processor and large memory space. This article presents a hybridized SVPWM for multiphase two-level VSI. In this algorithm, elements...
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublicationResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Compensation of Voltage Drops in Trolleybus Supply System Using Battery-Based Buffer Station
PublicationThis paper analyzes the results of a trial operation of a battery-based buffer station supporting a selected section of trolleybus power supply systems in Pilsen, Czech Republic. The buffer station aims to prevent the catenary from excessive voltage drops in a part of the route that is most remote from the traction substation. Compensation of voltage drops is carried out by continuously measuring the catenary voltage and injecting...
-
New Alternative Passive Networks to Improve the Range Output Voltage Regulation of the PWM Inverters
PublicationThis paper presents different topologies of buck-boost converters with passive input networks that have alternative topologies; this is known in the literature as a Z-source inverter. Alternative passive networks were named by the authors as T-inverters; these improve output voltage regulation of the PWM inverters. T-inverter has fewer reactive components in comparison to conventional Z-source inverter. The most significant advantage...
-
Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid
PublicationCurrent low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...
-
Hydro Power Plant in the Process of Voltage Control in the Electric Power System and the System Restoration
PublicationThe article covers selected issues related to the share of hydroelectric power in the process of rebuilding the power system after black-out and voltage control during that process. Selected results of measurements made during the creation of the transmission chain for the need to start a block of a thermal power plant from a hydroelectric power plant were presented.
-
Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter
PublicationIn the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...
-
Synthesis and properties of the double perovskites La2NiVO6, La2CoVO6, and La2CoTiO6
Publication -
Double-ridged horn antenna with sinusoidal ridge profile
PublicationPrzedstawiono wyniki symulacji numerycznej oraz pomiarów parametrów anteny tubowej z podwójnym grzbietem. Badania numeryczne dotyczyły zarówno samego układu zasilania falowodu grzbietowego jak i całej anteny z uwzględnieniem sinusoidalnego profilu impedancji grzbietu. Wyniki obliczeń dopasowania oraz charakterystyk promieniowania, wykonanych przy użyciu symulatora QW-3D, porównano z wynikami pomiarów, stwierdzając dobrą zgodność...
-
Structure and electric properties of double magnesium zirconium orthophosphate
PublicationPublikacja przedstawia wyniki pomiarów elektrycznych i strukturalnych ortofosforanu magnezowo-cyrkonowego.
-
Wear of the tool in double-disc lapping of silicon wafers
PublicationPrzedstawiono założenia modelowe do określania zużycia narzędzia w docieraniu krzemowych płytek półprzewodnikowych. Obliczenia zostały wykonane dla różnych parametrów kinematycznych, wpływających na zużycie narzędzia w określonych jego obszarach.
-
Double-Headed Cationic Lipopeptides: An Emerging Class of Antimicrobials
Publication -
Simulation of the profile wear of the tool in double wheel lapping
PublicationW pracy przedstawiono model zużycia narzędzia w docieraniu dwutarczowym. Wyprowadzono równania opisujące kontakt przedmiotu z narzędziem. Przedstawiono wyniki analiz symulacyjnych dla różnych parametrów kinematycznych - dla układu współbieżnego i przeciwbieżnego.
-
Myeloid-derived suppressor cells: a double-edged sword?
Publication -
Reactions of parylenes with double bonds: An ab initio study
Publication -
Simulation of the profile wear of the tool in double wheel lapping
PublicationPrzedstawiono założenia modelowe do wyznaczenia zużycia profilowego narzędzia w docieraniu dwutarczowym. Rozkłady istotnych czynników kinematycznych (prędkości docierania i przyspieszenia stycznego) wpływających na zużycie docieraka zaprezentowane zostały dla różnych typów zakreślanych trajektorii.
-
Numerical simulation of water drainage in double-porosity soils
PublicationArtykuł dotyczy modelowania przepływu wody w warunkach nienasyconych w gruntach o podwójnej porowatości, które są złożone z dwóch materiałów porowatych o bardzo różnych parametrach. przepływ w takich ośrodkach często charakteryzuje się powstawaniem lokalnych gradientów ciśnienia między obszarami dobrze isłaboprzepuszczalnymi.Przedstawiono matematyczny model przepływu wody w gruncie w strefie nienasyconej. Przepływ odbywa się w...
-
Experimental tests of steel double-type balcony connections
PublicationThe paper presents analysis and results of experimental tests of full scale prefabricated balcony sets with dimensions (width × length × height): 2.0 m × 2.78 m × 0.186 m (in slope to 0.17 m). The sets consists of reinforced concrete slabs (balcony and ceiling) connected with each other by double-type balcony connections. The paper analyses the impact of variable parameters on the load carry capacity of elements. Additionally...
-
Double ZIF-L structures with exceptional CO2 capacity
PublicationCarbon dioxide emission is an emerging problem nowadays and new methods are designed for its control. In this article, a report on the formation of zeolitic imidazole framework with an apparent double leaf-like morphology DZIF-L is given. The special structure of the materials prevents from aggregation of the particles providing remarkable CO2 capacity. At 0.1 MPa the CO2 uptake was 2.99 ± 0.06 mmol/g. The capacity of synthesized...
-
Double Bias of Mistakes: Essence, Consequences, and Measurement Method
PublicationThere is no learning without mistakes. However, there is a clash between‘positive attitudes and beliefs’regarding learning processes and the ‘negative attitudes and beliefs’towardthese being accompanied bymistakes. Thisclash exposesa cognitive bias towardmistakesthat might block personal and organizational learning. This study presents an advanced measurement method to assess thebias of mistakes. The essence of it is the...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a sea voyage
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials. The data were recorded during a sea voyage, under normal...
-
Use of a Virtual Instrument for Measurements of Direct Voltages in the Presence of Interferences
Publication -
Low frequency nois of supecapacitor
Open Research DataDataset contains results of low frequency noise observation during discharge of commercially available supercapacitor, type DRL 2.7V 10F, with a nominal capacitance 10 F and a nominal voltage 2.7 V. Supercapacitor was charged to various voltages and discharged through a resistor. In the experiment the 50 Ohm and 200 Ohm resistors were used. The supercapacitor...
-
Four Level Diode-Clamped Back-To-Back Converter with Active DC Link Voltage Control
PublicationThis article presents the design and control of 4L-DC back-to-back converter. To solve the DC link voltage balancing problem in four-level converter a new three-level double chopper topology based on PO-PWM modulation was designed and successfully tested. Also, the paper describes two phase space vector pulse width modulation 2P-SVPWM based on the shape function of finite elements. The control structure with modified Dead-Beat...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Single-phase, Five-level Inverter with SPWM-Based Neutral Point Voltage Balancing Scheme
PublicationMultilevel inverter topologies provide several advantages over two-level inverter configuration. These benefits are the reason for the growing interest in multilevel topologies among research society. One of the most popular topological concepts (diode and active switch clamping) requires neutral-point potential balancing due to series-connected capacitor banks across the input dc link in such derived inverter configurations. This...