Publications
Filters
total: 786
Catalog Publications
-
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublicationPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
-
Exsolution of Ni nanoparticles on the surface of cerium and nickel co-doped lanthanum strontium titanate as a new anodic layer for DIR-SOFC. Anti-coking potential and H2S poisoning resistance of the prepared material
PublicationThe aim of this study was to evaluate a new catalytic material for biogas fueled DIR-SOFC. This material was a perovskite-type SrTiO3 doped with La, Ce and Ni of a general formula La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-σ (LSCNT). Additional preparation steps were undertaken to promote a nickel exsolution process. Heat post-treatment of powders in a humidified H2 resulted in an intensive growth of nickel nanoparticles (NPs) while the temperature...
-
Head movement compensation algorithm in multi-display communication by gaze
PublicationAn influence of head movements on the gaze estimation accuracy when using a head mounted eye tracking system is discussed in the paper. This issue has been examined for a multi-display environment. It was found that head movement (rotation) to some extent does not influence on the gaze estimation accuracy seriously. Acceptable results were obtained when using eye-tracker to communicate with a computer via in two displays simultaneously.
-
Gaze tracking in multi-display environment
PublicationThis paper presents the basic ideas of eye and gaze tracking in multiple-display environment. The algorithm for display detection and identification is described as well as the rules for gaze interaction in multi display environment. The core of the method is to use special LED markers and eye and scene tracking glasses. Scene tracking camera registers markers position which is then represented as a cloud of points. Analyzing the...
-
Instrument detection and pose estimation with rigid part mixtures model in video-assisted surgeries
PublicationLocalizing instrument parts in video-assisted surgeries is an attractive and open computer vision problem. A working algorithm would immediately find applications in computer-aided interventions in the operating theater. Knowing the location of tool parts could help virtually augment visual faculty of surgeons, assess skills of novice surgeons, and increase autonomy of surgical robots. A surgical tool varies in appearance due to...
-
Study of Multi-Class Classification Algorithms’ Performance on Highly Imbalanced Network Intrusion Datasets
PublicationThis paper is devoted to the problem of class imbalance in machine learning, focusing on the intrusion detection of rare classes in computer networks. The problem of class imbalance occurs when one class heavily outnumbers examples from the other classes. In this paper, we are particularly interested in classifiers, as pattern recognition and anomaly detection could be solved as a classification problem. As still a major part of...
-
Long Distance Vital Signs Monitoring with Person Identification for Smart Home Solutions
PublicationAbstract— Imaging photoplethysmography has already been proved to be successful in short distance (below 1m). However, most of the real-life use cases of measuring vital signs require the system to work at longer distances, to be both more reliable and convenient for the user. The possible scenarios that system designers must have in mind include monitoring of the vital signs of residents in nursing homes, disabled people, who...
-
Design and characterization of apatite La9.8Si5.7Mg0.3O26±δ-based micro-tubular solid oxide fuel cells
PublicationIn this study, electrolyte-supported (Cell A) and anode-supported (Cell B) micro-tubular solid oxide fuel cells (SOFCs) based on the La9.8Si5.7Mg0.3O26±δ (LSMO) electrolyte is built through an extrusion and dip-coating processes. The formulations and process conditions for these cells are established and optimized. Both cell configurations show no visible delamination or cracking, and reaction zones and inter-diffusion of any species...
-
Study of oxygen electrode reactions on symmetrical porous SrTi0.30Fe0.70O3-δ electrodes on Ce0.8Gd0.2O1.9 electrolyte at 800 °C–500 °C
PublicationIron doped strontium titanates (SrTi1-xFexO3-δ) are an interesting mixed ionic-electronic conductor model used to study basic oxygen reduction/oxidation reactions. In this work, we performed an impedance spectroscopy study on symmetrical porous SrTi0.30Fe0.70O3-δ (STF70) electrodes on a ceriabased electrolyte. The sample was measured in varying oxygen concentration: from 0.3% to 100% in 800 °C - 500 °C temperature range. Low polarisation...
-
Properties of a lithium solid electrolyte gas sensor based on reaction kinetics
PublicationW artykule przedstawiono zasadę działania, budowę i właściwości czujnika gazu na bazie elektrolitu stałego z mobilnymi jonami litu. Czujnik został przygotowany w technologii grubowarstwowej. Przedstawiono wyniki badań czujnika w mieszaninach gazów toksycznych.
-
Monitoring of a bathing person
PublicationW pracy przedstawiono koncepcję i wstępne wyniki układu pozwalającego na monitorowanie stanu i aktywności osoby kąpiącej się. Zaprezentowany system pozwala na wykrycie osoby kąpiącej się w wannie, analizę jej aktywności oraz detekcję stanów potencjalnie niebezpiecznych. W artykule pokazano metodę pomiaru, dokonano analizy czułości, zaprezentowano prototyp układu pomiarowego i wyniki wstępnych pomiarów.
-
Septic safe interactions with smart glasses in health care
PublicationIn this paper, septic safe methods of interaction with smart glasses, due to the health care environment applications consideration, are presented. The main focus is on capabilities of an optical, proximity-based gesture sensor and eye-tracker input systems. The design of both interfaces is being adapted to the open smart glasses platform that is being developed under the eGlasses project. Preliminary results obtained from the...
-
Color Processing for Color-Blind Individuals Using Smart Glasses
PublicationIn this paper we investigated image processing methods for color-blind individuals. In particular we experimentally verified color naming procedure, generation of maps with color perception differences for average observers and for dichromats, and two color transformation methods. In experiments 7 mobile devices were used: 3 smart glasses and 4 smartphones. User studies were performed with 38 average observers and 9 dichromats....
-
A new diagnostic method for evaluation of cardiosurgery wound healing
PublicationOne of important and still unsolved problems in medicine is the question of objective and quantitative evaluation of post-surgery wound healing. The aim of this research is to analyse possibility and value of using the newly elaborated infrared imaging procedure – Active Dynamic Thermography (ADT) – for quantitative description of wound healing processes in cardiosurgery. Both, classical thermal figures of merit as well as ADT...
-
Real-time facial feature tracking in poor quality thermal imagery
PublicationRecently, facial feature tracking systems have become more and more popular because of many possible use cases. Especially in medical applications location of the face and facial features are very useful. Many researches have presented methods to detect and track facial features in visible light. However, facial feature analysis in thermography may also be very advantageous. Some examples of using infrared imagery in medicine include...
-
Face with Mask Detection in Thermal Images Using Deep Neural Networks
PublicationAs the interest in facial detection grows, especially during a pandemic, solutions are sought that will be effective and bring more benefits. This is the case with the use of thermal imaging, which is resistant to environmental factors and makes it possible, for example, to determine the temperature based on the detected face, which brings new perspectives and opportunities to use such an approach for health control purposes. The...
-
Synthesis of acceptor-doped Ba-Ce-Zr-O perovskites
PublicationPublikacja przedstawia wyniki badań stukturalnych i elektrycznych domieszkowanego akceptorow cerianu baru.
-
Evaluation of Respiration Rate Using Thermal Imaging in Mobile Conditions
PublicationRespiratory rate is very important vital sign that should be measured and documented in many medical situations. The remote measurement of respiration rate can be especially valuable for medical screening purposes (e.g. severe acute respiratory syndrome (SARS), pandemic influenza, etc.). In this chapter we present a review of many different studies focused on the measurements and estimation of respiration rate using thermal imaging...
-
Influence of operation temperature instability on gas sensor performance
PublicationGas sensors based on the semiconducting metal-oxides, such as SnO2, have been found to be very useful for detecting a wide range of gases. The reversible interactions of the gas with the surface of the sensing layer made of semiconducting metal-oxides are responsible for changes of sensor resistance which is usually used as a measure of sensor response. Semiconductor gas sensors are commercially available and applied in numerous...
-
The use of machine learning for face regions detection in thermograms
PublicationThe aim of this study is to analyse the methods of detecting characteristic points of the face in thermographic images. As part of the implementation an extensive analysis of scientific publications covering similar issues both for the analysis of images made in visible light and thermographic images was carried out. On the basis of this analysis, 3 models were selected and then they were implemented and tested on the basis of...
-
Role of quantitative chest perfusion computed tomography in detecting diabetic pulmonary microangiopathy
PublicationAims: Aimof the study was to determine the role of perfusion chest computed tomography(pCT) in evaluation of pulmonary diabetic angiopathy.Methods: 18 never-smoking patients (10 diabetic patients and 8 healthy controls) underwentchest high resolution CT (HRCT) and then pCT scanning. In both groups, blood tests,biochemical analysis, fibrinogen, HbA1c, spirometry, diffusion capacity for carbonmonoxide(DLCO) and body pletysmography...
-
FFT spectrum based matching algorithm for activedynamic thermography
PublicationIn Active Dynamic thermography (ADT) sequences of consecutive temperature distributions are analyzed. In biomedical applications of ADT, the problems of a patient's movements in front of a thermal camera should be eliminated before data analysis. Complete mechanical stabilization of the patients is impossible due to natural voluntary and involuntary moves caused by pulse breathing, etc. This paper presents a simple and efficient...
-
Sympathetic Activation Does Not Affect the Cardiac and Respiratory Contribution to the Relationship between Blood Pressure and Pial Artery Pulsation Oscillations in Healthy Subjects
PublicationUsing a novel method called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) and subarachnoid width (sas-TQ) in humans, we assessed the influence of sympathetic activation on the cardiac and respiratory contribution to blood pressure (BP) cc-TQ oscillations in healthy subjects. The pial artery and subarachnoid width response to handgrip...
-
Multimodal Platform for Continuous Monitoring of the Elderly and Disabled
Publication,
-
Comparison of active proximity radars for the wearable devices
PublicationTwo methods of object position and movement estimation in relation to the user of smart glasses were investigated. An active infrared and ultrasonic methods of the obstacle detection were presented and compared. Application of these methods depend on active transducers type (physical medium used), geometry and surface properties of detected objects and their movement direction and speed. In the article properties of both detectors...
-
Deposition and Electrical and Structural Properties of La0.6Sr0.4CoO3 Thin Films for Application in High-Temperature Electrochemical Cells
PublicationLow-temperature deposition of electroceramic thin films allows the construction of new devices and their integration with existing large-scale fabrication methods. Developing a suitable low-cost deposition method is important to further advance the development of microdevices. In this work, we deposited a 1-lm-thick La0.6Sr0.4CoO3d (LSC) perovskite with high electrical conductivity on sapphire substrates at 400C and analyzed its...
-
Characteristics of La0.8Sr0.2Ga0.8Mg0.2O3-delta -supported micro-tubular solid oxide fuel cells with bi-layer and tri-layer electrolytes
PublicationIn this study, La0.8Sr0.2Ga0.8Mg0.2O3−δ (LSGM)-supported micro tubular solid oxide fuel cells (T-SOFCs) with two different configurations, one containing an LSGM–Ce0.6La0.4O2−δ (LDC) bi-layer electrolyte (Cell A) and one containing an LDC–LSGM–LDC tri-layer electrolyte (Cell B), were fabricated using extrusion and dip-coating. After optimizing the paste formulation for extrusion, the flexural strength of the dense and uniform LSGM...
-
Gaze pattern lock for elders and disabled
Publication...
-
Low cost electrochemical sensor module for measurement of gas concentration
PublicationThis paper describes a low cost electrochemical sensor module for gas concentration measurement. A module is universal and can be used for many types of electrochemical gas sensors. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 is used. The proposed equipment will be used as a component of electronic nose system employed for classifying and distinguishing...
-
Influence of Thermal Imagery Resolution on Accuracy of Deep Learning based Face Recognition
PublicationHuman-system interactions frequently require a retrieval of the key context information about the user and the environment. Image processing techniques have been widely applied in this area, providing details about recognized objects, people and actions. Considering remote diagnostics solutions, e.g. non-contact vital signs estimation and smart home monitoring systems that utilize person’s identity, security is a very important factor....
-
Determination of the ionic conductivity of Sr-doped lanthanum manganite by modified Hebb–Wagner technique
PublicationThe Hebb–Wagne rpolarization method with the electron blocking electrode has been discussed in this paper in aim to determine a partial ionic conductivity of Sr-doped lanthanum manganite.The “limiting current” in the proposed system was measured using the two-point DC technique with additional Pt electrode between LSM and blocking electrode.The electrochemical model based on bulk diffusion processes and Boltzmann statistics has...
-
In-situ odd random phase electrochemical impedance spectroscopy study on the electropolymerization of pyrrole on iron in the presence of sodium salicylate – The influence of the monomer concentration
PublicationIn this work, the potentiostatic electropolymerization of polypyrrole (PPy) on iron in aqueous solution of sodium salicylate and pyrrole is studied in situ by odd random phase electrochemical impedance spectroscopy (ORP-EIS). The influence of the pyrrole concentration on the electrosynthesis process is investigated. The ORP-EIS technique ensures a reliable analysis of the PPy electrosynthesis on iron by means of an advanced data...
-
Acute hypoxia diminishes the relationship between blood pressure and subarachnoid space width oscillations at the human cardiac frequency
PublicationAcute hypoxia exerts strong effects on the cardiovascular system. Heart-generated pulsatile cerebrospinal fluid motion is recognised as a key factor ensuring brain homeostasis. We aimed to assess changes in heart-generated coupling between blood pressure and subarachnoid space width oscillations during hypoxic exposure.
-
Computerized Color Processing for Dichromats
PublicationArtykuł przedstawia opis metod w zakresie symulacji kolorów postrzeganych przez osoby z dichromacją oraz metod rozpoznawania kolorów jak i etykietowania kolorów w obrazach cyfrowych.
-
Determination of toxic gases based on the responses of a single electrocatalytic sensor and pattern recognition techniques
PublicationA response from an electrocatalytic gas sensor contains fingerprint information about the type of gas and its concentration. As a result, a single gas sensor can be used for the determination of different gases. However, information about the type of gas and its concentration is hidden in the unique shape of the current–voltage response and it is quite difficult to explore. One of the ways to get precise information about the measured...
-
Application of smart glasses for fast and automatic color correction in health care
PublicationIn recent years different applications of smart glasses in health care have been proposed. In this paper we present the experiments related to automatic color correction using smart glasses platform developed within the eGlasses project. The color pattern is proposed and tested enabling the automatic detection of the pattern and automatic correction of colors. Additionally, the method for encoding and decoding of patient ID in...
-
Increased inspiratory resistance affects the dynamic relationship between blood pressure changes and subarachnoid space width oscillations
PublicationBackground and objective Respiration is known to affect cerebrospinal fluid (CSF) movement. We hypothesised that increased inspiratory resistance would affect the dynamic relationship between blood pressure (BP) changes and subarachnoid space width (SAS) oscillations. Methods Experiments were performed in a group of 20 healthy volunteers undergoing controlled intermittent Mueller Manoeuvres (the key characteristic of the procedure...
-
Electrical conductivity of nanostructured acceptor-doped ceria fabricated by spark plasma sintering (SPS)
PublicationHigh purity nanoscale powders (~10–15 nm size) of two different compositions of ceria, doped with Gd3+ and Ca2+, have been consolidated by spark plasma sintering (SPS) at different temperatures. Fully-dense samples were observed only at a sintering temperature of 980 °C. The as-sintered samples showed rather fast grain growth with an average grain size below 300 nm. The electrical properties of the samples were evaluated by impedance...
-
Complex human computer interface for las patient
PublicationW pracy zaprezentowano system umożliwiający komunikację osobie sparaliżowanej z komputerem przy pomocy wzroku.
-
Investigation of sensing mechanism of Nasicon electrocatalytic sensors in nitrogen dioxide and ammonia
PublicationIn this paper a sensing mechanism of Nasicon electrocatalytic sensor in nitrogen dioxide and ammonia is investigated. Both gases are environmentally hazardous and contain nitrogen atom in the molecule. However, it seems that their sensing mechanism in electrocatalytic sensor could be totally different. Namely, the maximum sensitivity for each gas was obtained at different temperatures. Also, different auxiliary layers are formed...
-
Active dynamic thermography method for TRAM flap blood perfusion mapping in breast reconstruction
PublicationThis paper presents the new method of the transverse rectus abdominis musculocutaneous flap blood perfusion mapping based on the active dynamic thermography. The method is aimed at aiding a surgeon during breast reconstruction procedure. A pair of dTnorm and t90_10 parameters were used as parametric image descriptors of the flap blood perfusion. The method was tested on 38 patients that were subjected to breast reconstruction procedure....
-
A body position influence on ECG derived respiration
PublicationAn influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...
-
The Influence of Iron Doping on Performance of SrTi1-XFexO3-δ Perovskite Oxygen Electrode for SOFC
PublicationSolid Oxide Fuel Cells (SOFC) are based on electrolytes and mixed ionic and electronic conductivity (MIEC) materials. The need to reduce costs causes an increase in interest of new compounds suitable for operating temperatures between 600 °C and 800 °C. The SrTi1-xFexO3 (STF) perovskite material is a perspective material that could be used for the oxygen electrodes. In this work STF materials with different content of iron (x =...
-
Detection of person presence and its activity in the bathtub
PublicationA practical application of a bioimpedance technique for a detection of a bathing person is presented in the paper. It addresses the possibility of supervising people in the bathtub without voiding of their intimacy. The measurement system installed in a fiber-glass or a plastic bathtub is able to detect a presence of the bathing person, to estimate its activity and thus to detect potentially dangerous events. In the paper a principle...
-
Feasibility Study for Food Intake Tasks Recognition Based on Smart Glasses
PublicationIn this exploratory study 13 adult test subjects have performed different food intake tasks while wearing a three axis accelerometer mounted at a temple of glasses. Two different algorithms for task recognition have been applied and compared. The retrospective data processing leads to better task recognition results when the frequency range of 50 Hz to 100 Hz is analysed within accelerometer signal recordings. A straightforward...
-
Gas sampling system for matrix of semiconductor gas sensors
PublicationSemiconductor gas sensors are popular commercial sensors applied in numerous gas detection systems. They are reliable, small, rugged and inexpensive. However, there are a few problem limiting the wider use of such sensors. Semiconductor gas sensor usually exhibits a low selectivity, low repeatability, drift of response, strong temperature and moisture influence on sensor properties. Sample flow rate is one of the parameters that...
-
Evaluating Accuracy of Respiratory Rate Estimation from Super Resolved Thermal Imagery
PublicationNon-contact estimation of Respiratory Rate (RR) has revolutionized the process of establishing the measurement by surpassing some issues related to attaching sensors to a body, e.g. epidermal stripping, skin disruption and pain. In this study, we perform further experiments with image processing-based RR estimation by using various image enhancement algorithms. Specifically, we employ Super Resolution (SR) Deep Learning (DL) network...
-
Performance Analysis of Interaction between Smart Glasses and Smart Objects Using Image-Based Object Identification
PublicationWe propose the use of smart glasses to collaborate with smart objects in the Internet of Things environment. Particularly we are focusing on new interaction methods and the analysis of acceptable reaction times in the process of object recognition using smart glasses. We evaluated the proposed method using user studies and experiments with three different smart glasses: Google Glass, Epson Moverio, and the developed eGlasses platform....
-
Monitoring of breast tissue thermo-ablation by means of impedance measurements
PublicationW pracy przedstawiono rozważania dotyczące monitorowania jakości termoablacji zmian nowotworowych w piersi przy pomocy pomiarów impedancyjnych. Pokazano prototypowe konstrukcje sond do termoablacji jak również zaprezentowano wyniki symulacji i pierwszych eksperymentów. A usefulness of a developed probe combining power delivery to ablated breast tumour and simultaneous impedance measurements is discussed in the paper. It consists...
-
Age Prediction from Low Resolution, Dual-Energy X-ray Images Using Convolutional Neural Networks
PublicationAge prediction from X-rays is an interesting research topic important for clinical applications such as biological maturity assessment. It is also useful in many other practical applications, including sports or forensic investigations for age verification purposes. Research on these issues is usually carried out using high-resolution X-ray scans of parts of the body, such as images of the hands or images of the chest. In this...
-
Impedance spectroscopy of BaTiO3 cubes suspended in lossy liquids as a physical model of two-phase system
PublicationTechniki spektroskopii impedancyjnej zostały wykorzystane do analizy modelu fizycznego w układzie dwufazowym w celu wyznaczanie stałej dielektrycznej dielektryka umieszczonego w cieczy. Badania eksperymentalne przeprowadzono z użyciem BaTiO3 jako materiału dielektrycznego, który został przygotowany jako kostki o jednakowej wielkości 2x2x1 mm3.
-
The role of EMG module in hybrid interface of prosthetic arm
PublicationNearly 10% of all upper limb amputations concern the whole arm. It affects the mobility and reduces the productivity of such a person. These two factors can be restored by using prosthetics. However, the complexity of human arm makes restoring its basic functions quite difficult. When the osseointegration and/or targeted muscle reinnervation (TMR) are not possible, different modalities can be used to control the prosthesis. In...
-
Automatic analysis of the aggressive behavior of laboratory animals using thermal video processing
PublicationThe bite detection is very important but difficult element of the social interaction analysis. Standard observation methods like human observer or a camcorder of visible light frequencies fail in this case. However, it is possible to discern cooler spots on the rodent's body that appear after body contact with another individual, and vanish after short time. These spots are assumed to be a saliva trace left on fur after bite. In...
-
The passive operating mode of the linear optical gesture sensor
PublicationThe study evaluates the influence of natural light conditions on the effectiveness of the linear optical gesture sensor, working in the presence of ambient light only (passive mode). The orientations of the device in reference to the light source were modified in order to verify the sensitivity of the sensor. A criterion for the differentiation between two states - "possible gesture" and "no gesture" - was proposed. Additionally,...
-
Comparison of near infrared spectroscopy (NIRS) and near-infrared transillumination-backscattering sounding (NIR-T/BSS) methods
PublicationThe aim of the study was to compare simultaneously recorded a NIR-T/BSS and NIRS signals from healthy volunteers. NIR-T/BSS is a device which give an ability to non-invasively detect and monitor changes in the subarachnoid space width (SAS). Experiments were performed on a group of 30 healthy volunteers (28 males and 2 females, age 30.8 ± 13.4 years, BMI = 24.5 ± 2.3 kg/m2). We analysed recorded signals using analysis methods based...
-
Solid electrolyte gas sensors based on cyclic voltammetry with one active electrode
PublicationW artykule przedstawiono wyniki badań elektrokatalitycznego czujnika gazów toksycznych z jedną elektrodą aktywną.
-
Enhanced Remote Control Providing Medical Functionalities
PublicationThis paper presents the enhanced remote control and its role in pervasive healthcare in the home. The device was equipped with health-related measurement modules and a message-processing unit. Preliminary results are presented for monitoring of a pulse, hand tremors, grip forces, and for self evaluation procedures. The interaction of the device with the smart environment is presented and discussed.
-
High Temperature Corrosion Evaluation of Porous Hastelloy X Alloy in Air and Humidified Hydrogen Atmospheres
PublicationIn this work a commercially available porous Hastelloy X alloy is characterized in terms of high temperature corrosion resistance. The alloy was oxidized in the temperature range from 500C to 900C in air and humidified hydrogen for 100 hours. Corrosion rates and porosity changes were measured. Microstructural characterization was performed using X-ray diffractometry and scanning electron microscopy. Results show that porous alloys...
-
Ionic conductivity behavior by activated hopping conductivity (AHC) of barium aluminoborosilicate glass–ceramic system designed for SOFC sealing
PublicationNon-conducting BaO-B2O3-Al2O3-SiO2 parent glasses designed for solid oxide fuel cell (SOFC) sealing applications were prepared using the melt-quenching technique. The glass formation region was determined according to phase equilibrium relations and was found to be in the composition range 70BaO-(x)Al2O3-(10−x)B2O3-20SiO2 where 3.0 < x < 6.0 wt%. The conductivity values obtained conductivity ranged from 10−5 to 10−10 S/cm at temperatures...
-
Distribution of relaxation times as a method of separation and identification of complex processes measured by impedance spectroscopy
PublicationImpedance spectroscopy is one of the most commonly performed measurements to characterize electronic and electrochemical systems. Impedance spectra have limited resolution and many different processes may overlap what could be the reason of obstructions in its proper later analysis. Up to date, there are three approaches to solve this problem: examining impedance spectra itself, fitting spectra with equivalent circuits, and calculating...
-
Effect of sintering temperature on electrochemical performance of porous SrTi1-xFexO3-δ (x = 0.35, 0.5, 0.7) oxygen electrodes for solid oxide cells
PublicationThis work evaluates the effects of the sintering temperature (800 °C, 900 °C, 1000 °C) of SrTi1-xFexO3-δ (x = 0.35, 0.5, 0.7) porous electrodes on their electrochemical performance as potential oxygen electrode materials of solid oxide cells. The materials were prepared by a solid-state reaction method and revealed the expected cubic perovskite structure. After milling, the powders were characterised by a sub-micrometre particle...
-
Deep Instance Segmentation of Laboratory Animals in Thermal Images
PublicationIn this paper we focus on the role of deep instance segmentation of laboratory rodents in thermal images. Thermal imaging is very suitable to observe the behaviour of laboratory animals, especially in low light conditions. It is an non-intrusive method allowing to monitor the activity of animals and potentially observe some physiological changes expressed in dynamic thermal patterns. The analysis of the recorded sequence of thermal...
-
Coupling between Blood Pressure and Subarachnoid Space Width Oscillations during Slow Breathing
PublicationThe precise mechanisms connecting the cardiovascular system and the cerebrospinal fluid (CSF) are not well understood in detail. This paper investigates the couplings between the cardiac and respiratory components, as extracted from blood pressure (BP) signals and oscillations of the subarachnoid space width (SAS), collected during slow ventilation and ventilation against inspiration resistance. The experiment was performed on...
-
Can we rely on the pulse transit time - pressure relationship - models comparison
PublicationAn unobtrusive, noninvasive and continuous pressure measurement is invaluable however, still being under research and development. There are many attempts proposing an appropriate relationship between pulse pressure velocity and pressure. Fifteen different formulas, both theoretical and experimental, describing relation between blood pressure and crosssectional area of the vessel were examined. Using these formulas the relation...
-
Effects of Na+, K+ and B3+ Substitutions on the Electrical Properties of La10Si6O27 Ceramics
PublicationDoping of Na and K at La sites and of B at Si site in La10Si6O27 with oxyapatite structure and fabrication of their ceramics were made by the solid-state reaction method. It was found that partial substitution of Na+ and K+ on La sites decreased the sinterability of the La10Si6O27 based ceramics, whereas partial substitution of B3+ on the Si site improved the sinterability. Na+ and K+ substitutions in La10−xNaxSi6O27−x and La10−xKxSi6O27−x...
-
Estimation of the amplitude of the signal for the active optical gesture sensor with sparse detectors
PublicationIn this paper we deal with the problem of precise gesture recognition for the active optical proximity sensor with sparse 8 photodiodes. We particularly focus on developing the method of estimating the real, usually not observable, maximum signal value representing maximum intensity of light reflected from an obstacle present in the front of the sensor. Different configurations of the fingers were used as an obstacle. The Monte Carlo...
-
Semi complex navigation with an active optical gesture sensor
PublicationThis paper presents the methods of diversified touchless interactions between a user and a mobile platform utilizing the optical gesture sensor. The sensor uses 8 photodiodes to measure the reflected light in the active mode (using embedded LEDs) or it measures shadows caused by fingers in the passive mode. Several algorithms were implemented: automatic mode switching, adaptive illumination level compensation, resolution improvements...
-
A new diagnostic IR-thermal imaging method for evaluation of cardiosurgery procedures
PublicationTwo methods for monitoring the state of the myocardium during cardiosurgical interventions based on thermal IR imaging are presented below. These methods, called static thermography and active dynamic thermography (ADT), use information about the distribution of temperature on the surface, and an external excitation source to induce thermal transient processes in a tested object. Recording the time series of thermograms allows...
-
Capacitively coupled ECG measurements - a CMRR circuit improvement
PublicationA typical galvanic-connected electrocardiogram (ECG) measurement system utilizes two signal’s electrodes and a third one in driven-right-leg (DRL) circuit for improving a common-mode rejection ratio(CMRR) of the acquisition system. In capacitive-coupled ECG similar techniques are used, however it is expected, that the utilized DRL subsystem is formed using a capacitive coupling approach, too. An improvement of the acquisition system...
-
An electronic nose based on the semiconducting and electrochemical gas sensors
PublicationThe practical application of human nose for fragrance recognition is severely limited by the fact that our sense of smell is subjective and gets tired easily. Consequently, there is a significant need for an instrument that can be a substitution of the human sense of smell. Development of an electronic nose devices is an active area of research starting from pioneering research of Dodd and Persuad in the mid-1980s. Such systems...
-
Preparation of Hydrogen Electrodes of Solid Oxide Cells by Infiltration: Effects of the Preparation Procedure on the Resulting Microstructure
PublicationIn this work, the infiltration technique was used to produce hydrogen electrodes for solid oxide cells. Different infiltration methodologies were tested in order to try to shorten the infiltration cycle time. The porous scaffolds used for infiltration were based on highly porous yttria-stabilized zirconia (YSZ) obtained by etching the reduced nickel from the Ni-YSZ cermet in HNO3 acid. The support had a complex structure which...
-
Preliminary results from HEDGEHOG REXUS project – A sounding rocket experiment on accelerations, vibrations and heat flow
PublicationDuring flight, a sounding rocket is subject to a unique environment - severe vibrations and substantial heat flux. In order to design payloads, precise measurement of these conditions is required. This paper presents preliminary results from HEDGEHOG REXUS Project, whose scientific goal was to characterise the thermal and dynamic environment of REXUS sounding rockets. For this purpose, two new sensors have been designed - mechanical...
-
The effect of PEDOT morphology on hexavalent chromium reduction over 2D TiO2/PEDOT photocatalyst under UV–vis light
PublicationThe present study represents an approach to apply organic-inorganic hybrid materials for photocatalytic removal of heavy metals from the aqueous environment. The photocatalytic activity of the semiconductor modified with the conjugated polymer may depends on the conjugated polymer type, its amount and morphology. Therefore, in the present study the effect of poly (3, 4-ethylenedioxythiophene) (PEDOT) morphology on adsorption and photoreduction...
-
Effective dielectric constant of two phase systems: Application to mixed conducting systems
PublicationW pracy przedstawiono wyniki badań spektroskopii impedancyjnej systemów dwufazowych oraz ich porównanie z wynikami oczekiwanymi przez różne modele.
-
BP-EVD: Forward Block-Output Propagation for Efficient Video Denoising
PublicationDenoising videos in real-time is critical in many applications, including robotics and medicine, where varying light conditions, miniaturized sensors, and optics can substantially compromise image quality. This work proposes the first video denoising method based on a deep neural network that achieves state-of-the-art performance on dynamic scenes while running in real-time on VGA video resolution with no frame latency. The backbone...
-
Global Optimization for Recovery of Clipped Signals Corrupted With Poisson-Gaussian Noise
PublicationWe study a variational formulation for reconstructing nonlinearly distorted signals corrupted with a Poisson-Gaussian noise. In this situation, the data fidelity term consists of a sum of a weighted least squares term and a logarithmic one. Both of them are precomposed by a nonlinearity, modelling a clipping effect, which is assumed to be rational. A regularization term, being a piecewise rational approximation of the ℓ0 function...
-
Comparison of the exponential thermal transient parameterization methods with the SMTP method in the unipedicled DIEP flap computer modelling and simulation
PublicationThe aim of this paper is to compare the spatial contrast of the image descriptors obtained via three different thermal transient parameterization methods in Active Dynamic Thermography. The thermal constants and amplitude values of the one- and two- exponential parametrization are compared to the Simplified Magnitude-Temporal Parametrization method (SMTP). The comparison is performed using the data obtained by simulating the cold...
-
An assessment of health status and health behaviours in adolescents: main points and methods of the SOPKARD-Junior programme.
PublicationThe study involved preparing and implementing a model of screening assessments for adolescents and comparison of anthropometric examinations between the population of the SOPKARD-Junior programme and representative sample of Polish children in the same years.Additionally, data concerning attendance rates for particular examinations carried out under SOPKARD-Junior programme were presented.Revier2,comment 1
-
Interactions using passive optical proximity detector
PublicationIn this paper we evaluated the possible application of a passive, optical sensor as an interface for human-smart glasses interactions. The designed proximity sensor is composed of set of photodiodes and the appropriate hardware and software components. First, experiments were performed for the estimations of such parameters as distance to an object, its width and velocity. Achieved results were satisfactory. Therefore, next, a...
-
Active and Dynamic Graphical Code for Object Identification in Healthcare
PublicationA new approach for item marking using two dimensional discrete graphics markers. Proposed solution allow o change the code rapidly, upon request and in the case of thermal markers make the code invisible for unauthorized observers. Connecting the proposed codes with wearable multmedial platform such as eGlasses can create new possibilities in human-environment interaction.
-
Local Texture Pattern Selection for Efficient Face Recognition and Tracking
PublicationThis paper describes the research aimed at finding the optimal configuration of the face recognition algorithm based on local texture descriptors (binary and ternary patterns). Since the identification module was supposed to be a part of the face tracking system developed for interactive wearable computer, proper feature selection, allowing for real-time operation, became particularly important. Our experiments showed that it is...
-
Limited selectivity of amperometric gas sensors operating in multicomponent gas mixtures and methods of selectivity improvement
PublicationIn recent years, smog and poor air quality have became a growing environmental problem. There is a need to continuously monitor the quality of the air. The lack of selectivity is one of the most important problems limiting the use of gas sensors for this purpose. In this study, the selectivity of six amperometric gas sensors is investigated. First, the sensors were calibrated in order to find a correlation between the concentration...
-
Microporous N-Doped Carbon Obtained from Salt Melt Pyrolysis of Chitosan toward Supercapacitor and Oxygen Reduction Catalysts
PublicationThe direct carbonization of low-cost and abundant chitosan biopolymer in the presencesalt eutectics leads to highly microporous, N-doped nanostructures. The microporous structureeasily manufactured using eutectic mixture (ZnCl2 -KCl) and chitosan. Potassium ions here can act as an intercalating agent, leading to the formation of lamellar carbon sheets, whereas zinc chloride generates significant porosity. Here, we present an efficient...
-
The accuracy of pulse rate estimation from the sequence of face images
PublicationThe goal of this paper is to analyze the accuracy of pulse rate estimation from the sequence of face images. Simulated and real signals were used to evaluate two pulse rate estimators; one for frequency domain and the second one for time domain using the autocorrelation function. The results show that the mean difference between the reference measurements and estimated pulse rate values are about 2bpm. In the analysis of short...
-
Quantitative active dynamic thermal ir-imaging and thermal tomography in medical diagnostics
PublicationPraca dotyczy nowych technik obrazowania w diagnostyce medycznej, wykorzystując przetwarzanie obrazów termicznych rejestrowanych w podczerwieni. Opisano właściwości termiczne tkanek biologicznych, omówiono medele termiczne i zdefiniowano zastępcze parametry syntetyczne, metody pomiarów i stosowane urządzenia. Omówiono procedury akwizycji danych i ich przetwarzania. Wprowadzono pojęcie tomografii termicznej. Opisano przeprowadzone...
-
Evaluation of Praseodymium and Gadolinium Doped Ceria as a Possible Barrier Layer Material for Solid Oxide Cells
PublicationIn this work, nanocrystalline layers based on the Pr, Gd co-doped CeO2 were investigated. For the preparation of thin layers, lowtemperature spray pyrolysis technique was used. Different stoichiometries of the layers were produced for comparison on polished sapphire substrates. The microstructure of the prepared thin layers was studied by scanning electron microscopy (SEM), energydispersive X-ray spectroscopy (EDS) and X-ray diffractometry (XRD)....
-
Influence of the electrosynthesis conditions on the spontaneous release of anti-inflammatory salicylate during degradation of polypyrrole coated iron for biodegradable cardiovascular stent
PublicationIn this work, the spontaneous release of anti-inflammatory salicylate from polypyrrole (PPy) coated iron has been studied during degradation of the material in phosphate buffer saline at 37 C. The sodium salicylate was incorporated into PPy in a one-step electropolymerization process. The influence of the synthesis conditions such as sodium salicylate concentration, pyrrole concentration and deposition charge on drug release profile...
-
Analysis of Properties of an Active Linear Gesture Sensor
PublicationBasic gesture sensors can play a significant role as input units in mobile smart devices. However, they have to handle a wide variety of gestures while preserving the advantages of basic sensors. In this paper a user-determined approach to the design of a sparse optical gesture sensor is proposed. The statistical research on a study group of individuals includes the measurement of user-related parameters like the speed of a performed...
-
Structural and electrical properties of titanium-doped yttrium niobate
PublicationIn this work, the influence of the substitution of niobium by titanium in Y3Nb1-xTixO7-δ on the structural and electrical properties is reported. Several experimental techniques, i.e. X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM), X-Ray Photoelectron Spectroscopy (XPS) and Electrochemical Impedance Spectroscopy (EIS), were applied to investigate the system Y3Nb1-xTixO7-δ. Titanium in Y3Nb1-xTixO7-δ is an acceptor-type...
-
Characteristics of La 0.8 Sr 0.2 Ga 0.8 Mg 0.2 O 3-δ -supported micro-tubular solid oxide fuel cells with LaCo 0.4 Ni 0.6-x Cu x O 3-δ cathodes
PublicationIn this study, micro-tubular solid oxide fuel cells (T-SOFCs) with extruded La0.8Sr0.2Ga0.8Mg0.2O3-δ (LSGM) electrolyte as the mechanical support and LaCo0.4Ni0.6O3-δ (LCNO) or LaCo0.4Ni0.4Cu0.2O3-δ (LCNCO) as cathodes were prepared and characterized. Partial substitution of Cu for the Ni-ion positions in the LCNO lattices was found to significantly enhance the densification and accelerate the grain growth. The porosity-corrected...
-
Synthesis and Testing of BCZY/LNZ Mixed Proton–electron Conducting Composites for Fuel Cell Applications
PublicationA composite of BaCe0.6Zr0.2Y0.2O3–δ and Li2O:NiO:ZnO was investigated for fuel cell applications. The composite was successfully synthesized and its phase stability was confirmed at temperatures up to 900 °C. The influence of sintering and pressing aids on density was also investigated. Electrical properties were measured. DC electrical conductivity was about 8•10-4 S/m at 845 K. Open circuit voltage measurements in wet hydrogen...
-
Quantitative active dynamic thermal Ir-Imaging and thermal tomography in medical diagnostics
Publication -
Quantitative Active Dynamic Thermal IR-Imaging and Thermal Tomography in Medical Diagnostics
Publication.
-
Visual Attention Distribution Based Assessment of User's Skill in Electronic Medical Record Navigation
PublicationCurrently, the most precise way of reflecting the skills level is an expert’s subjective assessment. In this paper we investigate the possibility of the use of eye tracking data for scalar quantitative and objective assessment of medical staff competency in EMR system navigation. According to the experiment conducted by Yarbus the observation process of particular features is associated with thinking. Moreover, eye tracking is...
-
Investigation of solid polymer electrolyte gas sensor with different electrochemical techniques
PublicationIn this work solid polymer electrolyte (SPE) amperometric sulphur dioxide sensor is investigated. Nafion was used as a membrane electrode and 1M sulphuric acid as an internal electrolyte. Sensor response to sulphur dioxide was measured. Besides traditional constant voltage amperometry also different electrochemical techniques were used. Results obtained by these methods are compared.
-
Smart city and fire detection using thermal imaging
PublicationIn this paper, we summarize the results obtained from fire experiments. The aim of the work was to develop new methods of fire detection using IR thermal imaging cameras and dedicated image processing. We conducted 4 experiments in different configurations and with the use of different objects. The conducted experiments have shown the great usefulness of infrared cameras for detecting the seeds of a fire. Even cheap low-resolution...
-
The motion influence on respiration rate estimation from low-resolution thermal sequences during attention focusing tasks
PublicationGlobal aging has led to a growing expectancy for creating home-based platforms for indoor monitoring of elderly people. A motivation is to provide a non-intrusive technique, which does not require special activities of a patient but allows for remote monitoring of elderly people while assisting them with their daily activities. The goal of our study was to evaluate motion performed by a person focused on a specific task and check...
-
Influence of yttria surface modification on high temperature corrosion of porous Ni22Cr alloy
PublicationProtective coatings for porous alloys for high temperature use are relatively new materials. Their main drawback is high temperature corrosion. In this work protective coatings based the on Y-precursor infiltrated into the sintered Ni22Cr alloys are studied at 700°C. Effects of the amount of the protective phase on the resulting corrosion properties are evaluated in air and humidified hydrogen. Weight gain of the samples, their...
-
Coupling of Blood Pressure and Subarachnoid Space Oscillations at Cardiac Frequency Evoked by Handgrip and Cold Tests: A Bispectral Analysis
PublicationThe aim of the study was to assess blood pressure–subarachnoid space (BP–SAS) width coupling properties using time–frequency bispectral analysis based on wavelet transforms during handgrip and cold tests. The experiments were performed on a group of 16 healthy subjects (F/M; 7/9) of the mean age 27.2 ± 6.8 years and body mass index of 23.8 ± 4.1 kg/m². The sequence of challenges was first handgrip and then cold test. The handgrip...
-
Towards Contactless, Hand Gestures-Based Control of Devices
PublicationGesture-based intuitive interactions with electronic devices can be an important part of smart home systems. In this paper, we adapt the contactless linear gesture sensor for the navigation of smart lighting system. Set of handled gestures allow to propose two methods of active light source selection, continuous dimming, and turning on and off based on discrete gestures. The average gesture recognition accuracy was 97.58% in the...