Filtry
wszystkich: 2032
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: LOAD EQUIVALENCY FACTOR
-
Speed sensorless ac drive with inverter output filter and fault detection using load torque signal
PublikacjaIn this paper, a sensorless induction motor (IM) drive using speed observer system is presented. The system includes load torque computation for gear fault detection. Nonlinear control method is adopted for controlling the motor over a wide speed range. An LC filter for smoothing current and voltage waveforms is used at the output of the voltage inverter. The use of filter imposes more building of the used observer to avoid using...
-
Analysis of temporary steel grandstand with different bracing systems exposed to crowd load
PublikacjaGrandstands are structures which are regularly subjected to dynamic loads generated by crowd motions. It is a dangerous situation when spectators induce rhythmic jumping, dancing, stamping, etc. If the synchronized movement of spectators excites a natural frequency of the structure, resonant response might occur. To avoid such situations, temporary steel grandstands are commonly strengthened using additional elements that create...
-
Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid
PublikacjaCurrent low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...
-
The influence of reinforcement on load carrying capacity and cracking of the reinforced concrete deep beam joint
PublikacjaThe paper presents the results of experimental research of the spatial reinforced concrete deep beam systems orthogonally reinforced and with additional inclined bars. Joint of the deep beams in this research was composed of the longitudinal deep beam with a cantilever suspended at the transversal deep beam. The cantilever deep beam was loaded throughout the depth and the transversal deep beam was loaded at the mid-span by longitudinal...
-
Validation of Hydraulic Mechanism during Blowout Trauma of Human Orbit Depending on the Method of Load Application
PublikacjaThe more we know about mechanisms of the human orbital blowout type of trauma, the better we will be able to prevent them in the future. As long as the buckling mechanism’s veracity is not in doubt, the hydraulic mechanism is not based on equally strong premises. To investigate the correctness of the hydraulic mechanism’s theory, two different methods of implementation of the hydraulic load to the finite element method (FEM) model...
-
Morphology of damage inflicted on brittle polymer in lubricated contact under cyclic static load
PublikacjaIn this article morphology of damage inflicted on the polymethylmethacrylate (PMMA) plate in static point lubricated contact with a ball made of five different materials under cyclic normal load has been presented. It is argued that the counterface material and lubricating film play an important role in the damage process and the extent of damage inflicted in the PMMA plate.
-
A Novel Coupling Matrix Synthesis Technique for Generalized Chebyshev Filters With Resonant Source–Load Connection
PublikacjaThis paper reports a novel synthesis method for microwave bandpass filters with resonant source–load connection. In effect, a network realizing N+1 transmission zeros (where N is the number of reflection zeros) is obtained. The method is based on a prototype transversal coupling matrix (N+2, N+2) with source and load connected by a resonant circuit formed by a capacitor in parallel with a frequency-invariant susceptance. To complement...
-
Implementation of failover and load balancing algorithms in SIP PBX High Availability system
PublikacjaGoal of the project was to design a High Availability SIP VoIP system that guarantees access to additional services like auto-attendent and automatic call distribution. The realization of the project required system to have load balancing and failover algorithms implemented. From the end users’ point of view the whole system had to figure as a single element. After taking under consideration the known methods of implementations...
-
STABILITY AND LOAD BEARING CAPACITY OF A BARS WITH BUILT UP CROSS SECTION AND ELASTIC SUPPORTS
PublikacjaThe present paper is devoted to the numerical analysis and experimental tests of compressed bars with built–up cross section which are commonly used as a top chord of the roof trusses. The significant impact on carrying capacity for that kind of elements in case of out-of-plane buckling is appropriate choice of battens which are used to provide interaction between separate members. Linear buckling analysis results and nonlinear static...
-
Vascular endothelial growth factor (VEGF)-C - a potent risk factor in children diagnosed with stadium 4 neuroblastoma.
Publikacja -
Vascular endothelial growth factor C—a potent risk factor in childhood acute lymphoblastic leukaemia: an immunocytochemical approach
Publikacja -
Influence of the notch rounding radius on estimating the elastic notch stress concentration factor in a laser welded tee joint
PublikacjaIn recent years an increased interest of industry in sandwich-type metal structures can be observed. These structures consist of thin plates of 2.5 mm in thickness separated by stiffeners of different shapes and forms. Welds joining the plates and stiffeners are made on the outer side of the plates using laser welding technique. A locally focused source of heat causes the plate to melt creating a very narrow and elongated joint....
-
Selection of AHI + SC Hybrid Storage Based on Mathematical Models and Load Variation Characteristics
PublikacjaThe article deals with the design of a hybrid storage consisting of Aqueous Hybrid Ion battery (AHI) and supercapacitor (SC) modules. The selection of components is based on the knowledge of the load profile of the storage and the AHI battery and supercapacitor models. The paper presents the method of selecting components of the storage made of AHI batteries and supercapacitor modules The article includes an example of the hybrid...
-
Inverse Analysis as a Key Element of Safety Assessment under the Snow Load For The Large Suspension Roofs Structure
PublikacjaThe paper presents a concept and realization of monitoring system for the Silesian Stadium in Chorzow. The idea of the system lies in fusion of structure monitoring with a calibrated numerical FEM model [1]. The inverse problem is solved. On the base of measured selected displacements, the numerical FEM model of the structure combined with iterative method, develops the current snow load distribution. Knowing the load, we can calculate...
-
Destruction of shell structures under the dynamic load on the human skull trauma basis
PublikacjaThe main aim of this work is to investigate patterns of potential orbital bone fractures due to mechanical injuries. The solution of the main problem is followed by analysis of several testing examples having straight correlation with civil engineering structures, in which materials of wide range of stiffness are applied. To solve the main problem, the three-dimensional finite element method (FEM) model of the orbital region has...
-
Downlink Capacity-Coverage Trade-off Estimation Based on Measurement of WCDMA/FDD Interface Load
PublikacjaThe method of capacity-coverage trade-off determination by using of universal load characteristics and normalized coverage curves for the WCDMA/FDD radio interface has been presented. The practical applications of discussed method for UMTS radio network planning process and network exploitation has been mentioned.
-
DIAGNOSTIC INFORMATION ANALYSIS OF QUICKLY CHANGING TEMPERATURE OF EXHAUST GAS FROM MARINE DIESEL ENGINE PART I SINGLE FACTOR ANALYSIS
PublikacjaIn this paper, attention was paid to the problem of low controllability of marine medium- and high-speed engines during operation, which significantly limits the parametric diagnosis. The measurement of quickly changing temperature of engine exhaust gas was proposed, the courses of which can be a source of diagnostic information. The F statistic of the Fisher-Snedecor distribution was chosen as a statistical tool. Laboratory tests...
-
A facile approach to fabricate load-bearing porous polymer scaffolds for bone tissue engineering
PublikacjaBiodegradable porous scaffolds with oriented interconnected pores and high mechanical are load-bearing biomaterials for bone tissue engineering. Herein, we report a simple, non-toxic, and cost-effective method to fabricate high-strength porous biodegradable scaffolds, composed of a polymer matrix of polycaprolactone (PCL) and water-soluble poly (ethylene oxide) (PEO) as a sacrificial material by integrating annealing treatment,...
-
A 0.5 V Nanowatt Biquadratic Low-Pass Filter with Tunable Quality Factor for Electronic Cochlea Applications
PublikacjaA novel implementation of an analogue low-power, second-order, low-pass filter with tunable quality factor (Q) is presented and discussed. The filter feature is a relatively simple, buffer-based, circuit network consisting of eleven transistors operating in a subthreshold region. Q tuning is accomplished by injecting direct current into a network node, which changes the output resistance of the transistors and, as a result, modifies...
-
Scaling of signed residue numbers with mixed-radix conversion in FPGA with extended scaling factor selection
PublikacjaA scaling technique of signed residue numbers in FPGA is proposed. The technique is based on conversion of residue numbers to the Mixed-Radix System (MRS). The scaling factor is assumed to be a moduli product from the Residue Number System (RNS) base. Scaling is performed by scaling of MRS terms, the subsequent generation of residue representations of scaled terms, binary addition of these representations and generation of residues...
-
Load-carrying capacity of axially loaded concrete-filled steel tubular columns made of thin tubes
PublikacjaAn experimental investigation was conducted on 30 CFST columns. An influence of the following factors on load-carrying capacity of the investigated columns was analyzed: the column slenderness (l1 = 42, l2 = 27 and l3 = 15), the tube thickness (the reinforcement ratio was equal to 4% or 6%), the way of applying the load to CFST columns (through the concrete core or through the entire cross-section), the bond strength between a...
-
Laboratory Load Model Based on 150 kVA Power Frequency Converter and Simulink Real-Time – Concept, mplementation, Experiments
PublikacjaFirst section of the paper provides technical specification of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is presented. Theoretical considerations based on criteria which load types may be simulated using discussed laboratory setup, are described. As described model contains transformer with thyristor-controlled tap changer,...
-
Acoustic journal bearing – Performance under various load and speed conditions speed conditions
PublikacjaThe paper presents results of experimental testing aiming at finding out what effect system of piezo-electric actuators (PZTs)attached to an aerodynamic journal bearing has on the magnitude of shaft's motion within the bearing operating at specified speed and load. The results clearly demonstrate effectiveness of PZTs in mitigating the shaft's motion thus contributing to the increased stability of the bearing. This stabilizing...
-
The analysis of the empathy factor in students of medical sciences
Publikacja -
CRH functions as a growth factor/cytokine in the skin
Publikacja -
Performance persistence of government bond factor premia
Publikacja -
Seasonality in government bond returns and factor premia
Publikacja -
Spending on Innovation as a Factor of Competitiveness of Market Economies
Publikacja -
Sectarianism as a Factor Shaping Persian Gulf Security
Publikacja -
Noise as a Factor of Green Areas Soundscape Creation
Publikacja -
A boost topology active power factor corrector.
PublikacjaPrzedstawiono układ analogowego aktywnego korektora zbudowanego na układzie scalonym kontrolera PWM oraz tranzystorem MOS jako okresowo przełączonym kluczem. Układ korektora zapewnia pobór prądu z sieci energetycznej w postaci przebiegu prawie sinusoidalnego o małych zniekształceniach i w fazie z sinusoidalnym napięciem sieci.
-
Communication as a Factor Limiting University-Business Cooperation
PublikacjaObjective - Despite the broad extent of the scientific activity dealing with university-business cooperation, Poland has yet to develop a satisfactory cooperation strategy that takes business needs into account. This issue is still relevant due to the need for continuous improvement and resulting benefits aimed at improving enterprise competitiveness. Methodology/Technique - Authors of this article attempt to select an overriding...
-
Human Centric Lighting. The New X Factor?
PublikacjaWe live in challenging times, and one could even claim we’re experiencing a revolution in lighting with LED technology taking over the world. Part of this rapid change involves a concept called Human Centric Lighting (HCL). In Frankfurt this year, during Light+Building, it was the buzzword, with nearly every second manufacturer’s stand claiming they had figured out the special formula necessary to create perfect HCL illumination....
-
Robust Parameter Estimation and Output Prediction for Reactive Carrier-Load Nonlinear Dynamic Networks
PublikacjaIn this paper an extension of on-line model simplification technique for a class of networked systems, namely reactive carrier-load nonlinear dynamic networked system (RCLNDNS), kept within point-parametric model (PPM) framework is addressed. The PPM is utilised to acquire a piece wise constant time-varying parameter linear structure for the RCLNDNS suitable for the on-line one step ahead prediction that may be applied to monitoring...
-
Corrugated Sheeting as a Member of a Shear Panel Under Repeated Load—Experimental Test
PublikacjaIn stressed-skin design, the cladding stiffening effect on structures is taken into account. However, the “traditional” design is more usual, wherein this effect is neglected. Even if the diaphragm actions are not regarded, in particular cases such as big sheds (and others), the parasitic (unwanted) stressed-skin action may occur with the result of leakage or even failure. The structures of this kind have already been built. Thus,...
-
Bearing testing machine with rotating load vector.
PublikacjaW pracy przedstawiono koncepcję konstrukcyjną i prototyp stanowiska badawczego z wirująca reakcją łożyskową przeznaczonego do testowania wytrzymałości zmęczeniowej warstw ślizgowych w łożyskach poprzecznych. Konstrukcja i przeznaczenie maszyny zbudowanej w laboratorium tribologicznym Politechniki Gdańskiej jest zgodna z zaleceniami normy ISO 7905. Przeanalizowano zalety i wady maszyny badawczej o takim wzorcu obciążenia testującego.
-
An ANN-Based Method for On-Load Tap Changer Control in LV Networks with a Large Share of Photovoltaics—Comparative Analysis
PublikacjaThe paper proposes a new local method of controlling the on-load tap changer (OLTC) of a transformer to mitigate negative voltage phenomena in low-voltage (LV) networks with a high penetration of photovoltaic (PV) installations. The essence of the method is the use of the load compensation (LC) function with settings determined via artificial neural network (ANN) algorithms. The proposed method was compared with other selected...
-
Angiopoietin-like growth factor-derived peptides as biological activators of adipose-derived mesenchymal stromal cells
PublikacjaAdipose-derived mesenchymal stromal cells (AD-MSCs) are an essential issue in modern medicine. Extensive preclinical and clinical studies have shown that mesenchymal stromal/stem cells, including AD-MSCs, have specific properties (ability to differentiate into other cells, recruitment to the site of injury) of particular importance in the regenerative process. Ongoing research aims to elucidate factors supporting AD-MSC culture...
-
Improving the procedure of probabilistic load testing design of typical bridges based on structural response similarities
PublikacjaThis paper concerns load testing of typical bridge structures performed prior to operation. In-situ tests of a two-span post-tensioned bridge loaded with three vehicles of 38-ton mass each formed the input of this study. On the basis of the results of these measurements, an advanced FEM model of the structure was developed for which the sensitivity analysis was performed for chosen uncertainty sources. Three uncorrelated random...
-
Ultimate strength of stiffened plates subjected to compressive load and spatially distributed mechanical properties
PublikacjaThe present study deals with the ultimate strength of stiffened plates subjected to spatially distributed mechanical properties and compressive load. Normally, mean values of mechanical properties based on tensile tests are used to validate the numerical assessment with experimental results. However, mechanical properties may vary within a single specimen. To investigate the impact of that, random fields of yield stress and Young...
-
Measurements of no-load and short-circuit parameters of power transformers with taps
Dane Badawcze1) The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E).
-
Report no WOiO/II/67/2015 - Expertise about load capacity of twistlock foundation and sliding foundation
PublikacjaCustomer delivered to Laboratory 17 elements - twist lock foundations and sliding lock foundations (ship equipment for container lashing). Elements were selected from production series. Each element was loaded for braking load. After test visual inspection had been performed. The expertise contains: description of tested elements, test assumptions, test stand, results and conclusions
-
The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid
PublikacjaThis paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered...
-
A CONCEPT OF DETERMINING THE RELATION BETWEEN LOAD AND WEAR OF TRIBOLOGICAL SYSTEMS OF SHIP MAIN SELF-IGNITION ENGINES BY USING PROBABILISTIC APPROACH PROBABILISTIC APPROACH
PublikacjaThis paper presents a proposal of simultaneous consideration of load and wear associated with it , of tribological systems of ship main engines (intended for ship propulsion) . Based on results of investigations it was assumed that both the load Q (i.e. a cause of wear ) and the wear Z (i.e. an effect of load occurrence) considered in a given time t(0 ≤ t ≤ t) are random variables Qt and Zt, respectively. There was characterized...
-
Prototype design and development of low-load-roof photovoltaic modules for applications in on-grid systems
PublikacjaFour prototypes of lightweight photovoltaic modules for applications in on-grid systems have been designed, developed, manufactured and tested for compliance with relevant IEC standards. Selected, commercially available materials characterized by thermogravimetry, differential scanning calorimetry, dilatometry, scanning electron microscopy and nanoindentation technique were used in frameless, adhesively-bonded sandwich-structures...
-
Simplified approach to assess the dynamic response of a container ship subjected to bow slamming load
PublikacjaSimplified approach to assess the dynamic response of a container ship subjected to the bow slamming load, resulting in a transient vibratory response, typically called a 'whip-ping', is presented. The accurate numerical modelling is very complex and involves cou-pling of the hydrodynamic and structural solution at every time step, leading to huge com-putational and workload cost. Thus, the one-way coupling methodology is adopted,...
-
Degradation of stiffness of building columns exposed to bending and impact load during ground motions
PublikacjaThe safety of civil engineering structures under external loads, including ground motions, is one of the issues related to the idea of sustainable society. The earthquake-induced soft-storey failure is a typical type of damage observed in buildings due to seismic excitation. The failure of an intermediate soft storey of a structure results in large vertical impact loading acting on the lower floors due to the fall of the upper...
-
Improvement of the load capacity of the road overpass as a result of repairs after breakage caused by vehicle impacts
PublikacjaDamage of spans of the overpass caused by impact of underpassing vehicles are a frequent case. Objects that use prefabricated load-bearing elements that are not designed for such impacts are particularly exposed. After impact, such parts suffer extensive damage that need repair. Taking advantages of this recovery actions it is worth to perform strengthening that will protect object against possible future impacts. In this study...
-
Numerical modelling and analysis of steel specimens subjected to marine immersed corrosion and tensile load
PublikacjaThe present study develops numerical models to analyse the behaviour of steel specimens subjected to marine immersed corrosion degradation and tensile load. The finite element method with the use of the explicit dynamic solver LS-DYNA, satisfying the quasi-static conditions, is employed. Two numerical models are developed, where in the first one, the scans of surfaces gathered from corroded plate specimens are implemented directly...
-
Study on deformed steel columns subjected to impact load due to soft-storey failure in buildings during earthquakes
PublikacjaThe so called soft-storey failure is one of the most typical types of damage induced in buildings as the result of earthquake excitation. It has been observed during ground motions that the failure of an upper soft storey of a structure results in large vertical impact load acting on the lower floors. If the resistance of the structural members of the lower storeys is not sufficient it may further lead to progressive collapse of...