Wyniki wyszukiwania dla: POWER MEASUREMENT
-
Management of MV/LV Transformer Replacement Based on AMI Platform
PublikacjaThe paper presents the extended possibilities of managing the selection and replacement of MV/LV transformers using the measurement data from the Advanced Metering Infrastructure (AMI) system. The analysis was conducted on samples of over 1900 transformers that operate in two different types of MV grids: rural and urban. The analysis has shown that there is a great potential in the field of optimizing the rated power of the transformers.
-
A cumulative probability function of instantaneous flicker sensation values measured in the industrial power system supplying the rolling mill motors
Dane BadawczeThe dataset presents a cumulative probability function CPF of the instantaneous flicker sensation level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Channel Impulse Response Measurements at mmWave Band in Office and Conference Rooms
PublikacjaIn this paper, the measurements of the channel impulse response at mmWave band in office and conference rooms are described. The central frequency is 27 GHz with a bandwidth of 400 MHz. The description of the used measurement stand and considered environments are presented. The initial analysis of the power delay profile, mean delay, and RMS delay spread allows preliminary conclusions to be drawn that there is a significant impact...
-
Audible noise in ship’s electrical drive systems with frequency converters
Dane BadawczeThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
Light box for investigation of characteristics of optoelectronics detectors
PublikacjaIn this paper, a light box for investigation of characteristics of optoelectronic detectors is described. The light box consists of an illumination device, an optical power sensor and a mechanical enclosure. The illumination device is based on four types of high-power light emitting diodes (LED): white light, red, green and blue. The illumination level can be varied for each LED independently by the driver and is measured by optical...
-
The conducted immunity test of an AC adaptor in accordance with EMC standards
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the ac adaptor PHILIPS DC power supply SBC 6654. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz...
-
Narrowband Transmission Quality in Presence of Modified IEEE 802.15.4a UWB Signal
PublikacjaThis paper presents results of measurement of narrowband transmission quality in presence of impulse radio UWB interference. In the first part of paper, unmodified IEEE 802.15.4a IR UWB signal is used. Then some modification of transmitted pulse sequence is proposed, which allow to reduce UWB power spectral density at frequency of narrowbandtransmission. Finally narrowband transmission quality in presence of modified ultrawideband...
-
Experimental Study of the Influence of Noise Level on the Uncertainty Value in a Measurement System Containing an Analog-to-Digital Converter
Dane BadawczeFor newly developed measuring systems it is easy to estimate type B uncertainties based on the technical data of the measuring modules applied. However, it is difficult to estimate A type un-certainties due to the unknown type and level of interferences infiltrating into the measuring sys-tem. This is a particularly important problem for measurements...
-
Problems of varistor quality assessment during exploitation
PublikacjaVaristors are commonly used elements which protect power supply networks against high-voltage surges or lightning. Therefore, quality and endurance of these elements is important to avoid losses when an expensive laboratory equipment would not be protected from random overvoltages. Additionally, excessive leakage currents generate serious costs due to high energy consumption. The paper presents shortly properties of varistors that...
-
Instrumental measurement of odour nuisance in city agglomeration using electronic nose
PublikacjaThe paper describes an operation principle of odour nuisance monitoring network in a city agglomeration. Moreover, it presents the results of investigation on ambient air quality with respect to odour obtained during six-month period. The investigation was carried out using a network comprised of six prototypes of electronic nose and Nasal Ranger field olfactometers employed as a reference method. The monitoring network consisted...
-
Analysis of Vibration and Acoustic Signals for Noncontact Measurement of Engine Rotation Speed
PublikacjaThe non-contact measurement of engine speed can be realized by analyzing engine vibration frequency. However, the vibration signal is distorted by harmonics and noise in the measurement. This paper presents a novel method for the measurement of engine rotation speed by using the cross-correlation of vibration and acoustic signals. This method can enhance the same frequency components in engine vibration and acoustic signal. After...
-
Installation of GNSS receivers on a mobile railway platform – methodology and measurement aspects
PublikacjaDetermining the course of a railway track axis using satellite methods relies on ensuring the precise assembly of GNSS receivers in dedicated measuring devices. Depending on the number of receivers, solutions that are based on placing the apparatus directly above the railway track axis (as well as in eccentric positions) are used to indirectly obtain data to form the basis of the desired results. This publication describes the...
-
Electrodes array for contactless ECG measurement of a bathing person - a sensitivity analysis
PublikacjaAn applicability of a remote (contactless) electrocardiogram (ECG) measurements in a bathtub is presented in the paper. Possibility of ECG measurements in shallowly filled tube with a water was examined. A bathing person was, both, sitting and lying during experiments performed. The problem became non-trivial when the bathing person was moving in reference to a fixed set of electrodes and located at the longer walls of the bathtub....
-
Nanocrystalline diamond sheets as protective coatings for fiber-optic measurement head
PublikacjaFiber-optic sensors find numerous applications in science and industry, but their full potential is limited because of the risk of damaging the measurement head, in particular, due to the vulnerability of unprotected tips of the fiber to mechanical damage and aggressive chemical agents. In this paper, we report the first use of a new nanocrystalline diamond structure in a fiber-optic measurement head as a protective coating of...
-
Selection of measurement frequency in Mott–Schottky analysis of passive layer on nickel
Publikacja -
3D MONITORING � IDENTIFICATION OF MEASUREMENT PROBLEMS AT LARGER MOVEMENTS OF THE TRACKED POINTS
Publikacja -
Study of swimbladder morphometry of Baltic herring and sprat (development of measurement methodology)
PublikacjaEffective management of Baltic clupeids, which are valuable commercially and ecologically,requires the biomass control. The acoustical techniques are recognized as effective in fishstock assessment. The study of Baltic herring and sprat individual backscatteringcharacteristics is required for the accurate biomass estimation using acoustical techniques.The previous measurements demonstrated significant...
-
Shaping coherence function of sources used in low-coherent measurement techniques
Publikacja -
Experimental certification of an informationally complete quantum measurement in a device-independent protocol
PublikacjaMinimal informationally complete positive operator-valued measures (MIC-POVMs) are special kinds of measurement in quantum theory in which the statistics of their d2-outcomes are enough to reconstruct any d-dimensional quantum state. For this reason, MIC-POVMs are referred to as standard measurements for quantum information.Here, we report an experiment with entangled photon pairs that certifies, for what we believe is the first...
-
Chapter 6 : Non-intrusive measurement techniques in bubble dynamics investigation
PublikacjaPrzedstawiono wyniki badań dynamiki pęcherzyków parowych i gazowych przy użyciu nieinwazyjnych metod optycznych i akustycznych.
-
Installation of GNSS receivers on a mobile railway platform – methodology and measurement aspects
Publikacja -
Portable computer diagnostics system PSD - the measurement potentiality and application examples
PublikacjaOpisano system diagnostyczny do pomiarów statycznych i dynamicznych wszelkiego typu maszyn stosowanych w przemyśle drzewnym. ocena stanu maszyny może byc dokonywana na podstawie wyników pomiaru bicia osiowego i promieniowego wrzecion, pił tarczowych, przemieszczeń poprzecznych piły tasmowej itp.. System jest wyposażony w specjalne oprogramowanie i pozwala m. in. na przeprowadzanie szczegółowych analiz tj. wykonywanie FFT lub filtrowanie...
-
Shaping of coherence function of sources used in low-coherent measurement techniques
PublikacjaW artykule przedstawiono zależność pomiędzy charakterystyką widmową źródła i ekwiwalentną długością drogi koherencji źródła. Wyniki analizy teoretycznej i symulacji komputerowych wykazały, że użycie źródła syntezowanego wpływa na zmniejszenie wartości ekwiwalentnej długości drogi koherencji. Dodatkowo wykazano, że zmniejszenie ekwiwalentnej długości drogi koherencji można otrzymać poprzez odpowiednie kształtowanie funkcji koherencji...
-
P-674 Automatizing ovarian follicle counting and measurement with artificial intelligence
Publikacja -
Application of acoustic emission metod for measurement of joint gap and cartilage surfaces
PublikacjaW artykule przedstawiono zastosowanie emisji akustycznej do lokalizacji wczesnych uszkodzeń stawu biodrowego lub kolanowego człowieka. Ponadto metoda ta służy do pomiaru wysokości szczeliny stawu oraz struktury geometrycznej powierzchni chrząstki stawowej. Jest to metoda nieinwazyjna. Pomiary metodą emisji akustycznej stosujemy na ogół w materiałach, w których energia sprężysta zmienia się nagle. Takie zmiany energii mogą być...
-
Shaping coherence function of sources used in low-coherent measurement techniques
PublikacjaW niskokoherencyjnych technikach pomiarowych kształt funkcji koherencji wykorzystywanego źródła ma bezpośredni wpływ na parametry metrologiczne układu pomiarowego. Z tego względu, w wielu aplikacjach niezbędne jest użycie metod pozwalających na zmianę kształtu tej funkcji. W artykule przeanalizowano możliwości kształtowania funkcji koherencji, a przedstawione analizy teoretyczne i wyniki symulacji komputerowych wskazują, że kształtowanie...
-
Measurement of complex refractive index of human blood by low-coherence interferometry
PublikacjaIn this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherencei nterferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum...
-
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublikacjaThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
Measurement of the Development of a Learning IT Organization Supported by a Model of Knowledge Acquisition and Processing
PublikacjaThe paper presents a model of knowledge acquisition and processing for the development of learning organizations. The theory of a learning organization provides neither metrics nor tools to measure its development The authors' studies in this field are based on their experience gathered after projects realized in real IT organizations. The authors have described the construction of the model and the methods of its verification...
-
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublikacjaThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
Measurement of rare probes with the silicon tracking system of the CBM experiment at FAIR
Publikacja -
2015. Motion analysis of a kitesurfer employing a vision-based measurement system
PublikacjaAbstract. Kitesurfing is a relatively new phenomenon with rising popularity worldwide – a recently developed extreme watersport considered a high-risk injury sport. It combines elements of several other sports, in particular, sailing, surfing, windsurfing, wakeboarding, and snowboarding. The main purpose of authors’ research in the present paper is to use a vision-based system for measuring a kitesurfer’s body movements in order...
-
3D Monitoring - Identification of measurement problems at larger movements of the tracked points
PublikacjaAuthors identified the problems associated with the determination of the controlled points coordinates by use of automated Total Station placed behind transparent barrier. Important thing in the mentioned analysis was a large change of controlled points position and not stable Total Station’s stand (because of stand’s thermal drift). This two elements, combined with measurement made through glass plate determine the need for impact...
-
Polarization interferometer using a Liquid Crystalline Polymer waveplate for wavelength measurement
PublikacjaA two-beam polarization interferometer for measuring wavelength changes of a tunable semiconductor laser was designed, built and tested. This interferometer uses a λ/8 waveplate made from Liquid Crystalline Polymer in order to generate two output signals in quadrature. The λ/8 waveplate can be manufactured either on a beamsplitter face or on the mirror surface, reducing the cost and complexity of the optomechnical assembly. Experiment...
-
Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants
PublikacjaThe study presents information about the measurement techniques used for the assessment of air quality in terms of the olfactory intensity resulting from the operation of municipal sewage treatment plants. Advantages and disadvantages of the measurement techniques used are presented. Sources of malodourous substance emission from sewage treatment plants were described, and the malodourous substances emitted were characterised....
-
Application of electrochemical sensors and sensor matrixes for measurement of odorous chemical compounds
PublikacjaIn this paper describes the principle of operation of the electrochemical sensors and the sensor matrixes comprised of electrochemical sensors intended for measurement of odorous compounds. Critical comparison of these sensors’ advantages and disadvantages has been made. The fields of economy contributing to release of odours and the potential sources of their emission have been identified. Commercially available electrochemical...
-
Comparison of the measurement techniques employed for evaluation of ambient air odour quality
PublikacjaThe paper presents the results of investigation on ambient air odour quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field...
-
Measurement and visualization of sound intensity vector distribution in proximity of acoustic diffusers
PublikacjaIn this work, we would like to present analyses and visualizations of sound intensity distribution measured in proximity of an acoustic diffuser. Such distribution may be used for estimation of basic acoustic parameters of a diffuser. Measurement is performed with the use of a logarithmic sine sweep which allows for the analysis of waves scattered by the diffuser and rejecting the direct sound signal component. Pressure and sound...
-
Measurement of luminance and color uniformity of displays using the large-format scanner
PublikacjaUniformity of display luminance and color is important for comfort and good perception of the information presented on the display. Although display technology has developed and improved a lot over the past years, different types of displays still present a challenge in selected applications, e.g. in medical use or in case of multi-screen installations. A simplified 9-point method of determining uniformity does not always produce...
-
Measurement of Impulse Response of Shallow Water Communication Channel by Correlation Method
PublikacjaPerformances of underwater acoustic communication (UAC) systems are strongly related to specific propagation conditions of the underwater channel; conditions that can additionally change in time due to the movement of the acoustic system transmitter and receiver or to reflection by underwater objects of the transmitted signal. The time-varying impulse response is a comprehensive description of dynamically changing transmission...
-
Analysis of the Usefulness of Cheap Audio Recorders for Spectral Measurement of Environmental Noise
PublikacjaEnvironmental noise pollution is nowadays one of the most serious health threats. The impact of noise on the human body depends not only on the sound level but also on its spectral distribution. Reliable measurements of the environmental noise spectrum are often hampered by the very high price of top quality measuring devices. This paper explores the possibility of using much cheaper audio recorders for the frequency analysis....
-
Sounding Mechanism of a Flue Organ Pipe—A Multi-Sensor Measurement Approach
PublikacjaThis work presents an approach that integrates the results of measuring, analyzing, and modeling air flow phenomena driven by pressurized air in a flue organ pipe. The investigation concerns a Bourdon organ pipe. Measurements are performed in an anechoic chamber using the Cartesian robot equipped with a 3D acoustic vector sensor (AVS) that acquires both acoustic pressure and air particle velocity. Also, a high-speed camera is employed...
-
The evaluation of the vibration measurement usability of electronic indicator lemag "premet C"
PublikacjaThe measuring possibilities of modern compression and combustion pressure analyzers are extended with additional functions. One of them is parallel to the pressure measurement, the measurement of vibrations in the region of the cylinder head. The paper presents a general assessment of the vibration measurement function of the electronic indicator LEMAG "PREMET C". This feature is very rarely offered by manufacturers of these devices....
-
A review of design approaches for the implementation of low-frequency noise measurement systems
PublikacjaElectronic noise has its roots in the fundamental physical interactions between matter and charged particles, carrying information about the phenomena that occur at the microscopic level. Therefore, Low-Frequency Noise Measurements (LFNM) are a well-established technique for the characterization of electron devices and materials and, compared to other techniques, they offer the advantage of being non-destructive and of providing...
-
Selection of measurement frequency in Mott-Schottky analysis of passive layer on nickel
PublikacjaPrzedstawiono zależności Mott'a - Schottky'ego dla różnych częstotliwości pomiarowych. Kształt uzyskanych zależności zależy od doboru tych częstotliwości. Związane jest to z tym, że stężenie defektów w warstwie pasywnej zależy od doboru częstotliwości. Metoda DEIS pozwala na uniknięcie tych niedogodności.
-
Analytical progress on symmetric geometric discord: Measurement-based upper bounds
PublikacjaQuantum correlations may be measured by means of the distance of the state to the subclass ofstates having well defined classical properties. In particular, a geometric measure of asymmetricdiscord [Daki´c et al., Phys. Rev. Lett. 105, 190502 (2010)] was recently defined as the Hilbert-Schmidt distance of a given two-qubit state to the closest classical-quantum (CQ) correlated state.We analyze a geometric measure of symmetric...
-
Neural network model of ship magnetic signature for different measurement depths
PublikacjaThis paper presents the development of a model of a corvette-type ship’s magnetic signature using an artificial neural network (ANN). The capabilities of ANNs to learn complex relationships between the vessel’s characteristics and the magnetic field at different depths are proposed as an alternative to a multi-dipole model. A training dataset, consisting of signatures prepared in finite element method (FEM) environment Simulia...
-
The influence of sampling parameters on accuracy of capacitance measurement in the method based on DSP.
PublikacjaW artykule przedstawiono metodę pomiaru parametrów impedancyjnych bazującą na próbkowaniu sygnałów pomiarowych i DSP. Przeanalizowano wpływ głównych źródeł niepewności i błędów na dokładność pomiaru pojemności. Zawarto analizę dla następujących parametrów: niesynchroniczne próbkowanie sygnałów pomiarowych (napięciowego i prądowego), rozdzielczość przetwornika a/c i ilość zbieranych próbek. Załączono wyniki symulacji.