Wyniki wyszukiwania dla: DIFFERENTAL PULSE VOLATAMMETRY
-
Digital processing of pulse signal from light-to-frequency converter under dynamic condition
Publikacja -
The use of a static electrical energy meter as a transducer of active power to a pulse frequency signal
Publikacja -
Application of Analytic Signal and Smooth Interpolation in Pulse Width Modulation for Conventional Matrix Converters
PublikacjaThe paper proposes an alternative and novel approach to the PWM duty cycles computation for Conventional Matrix Converters (CMC) fed by balanced, unbalanced or non–sinusoidal AC voltage sources. The presented solution simplifies the prototyping of direct modulation algorithms. PWM duty cycles are calculated faster by the smooth interpolation technique, using only vector coordinates, without trigonometric functions and angles. Both...
-
Measurement of pulse signal period from incremental encorder by counters of Multifunctuin DAQ devices.
PublikacjaW artykule omówiono parametry liczników znajdujących się na wielofunkcyjnych kartach akwizycji sygnałów pomiarowych. Przedstawiono przygotowane w środowisku programowania Lab VIEW aplikacje wykorzystujące te liczniki. Służą one do pomiaru i rejestracji długości zadanej liczby okresów mierzonego sygnału oraz liczby okresów uzależnionej od ich długości (metoda zliczania zależnego z wydłużonym czasem pomiaru). Aplikacje te zostały...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
A Single-Carrier-Based Pulse-Width Modulation Template for Cascaded H-Bridge Multilevel Inverters
PublikacjaMultiplicity of the triangular carrier signals is a criterion for the extension of sinusoidal pulsewidth modulation, SPWM, to a number of output voltage levels per phase-leg in cascaded H-bridge (CHB) multilevel inverter (MLI). Considering medium and high voltage applications where appreciable number of output voltage levels from CHB MLI is needed, commensurate high number of carrier signals in either classical level- or phase-shifted...
-
An independent relationship between muscle sympathetic nerve activity and pulse wave velocity in normal humans
Publikacja -
Augmentation index, pulse pressure amplification and superoxide anion production in patients with coronary artery disease
Publikacja -
Software-based method of increasing the effective resolution of a measurement chain for a transducer with a pulse frequency output
Publikacja -
A microcontroller system for measurement of three independent components in impedance sensors using a single square pulse
PublikacjaOpracowano nową metodę pomiaru w dziedzinie czasu i wyznaczania trzech składowych elementów modelu czujnika impedancyjnego oraz zaimplementowano ją w inteligentnym czujniku impedancji sterowanym 8-bitowym mikrokontrolerem. Metoda bazuje na pobudzeniu dzielnika napięciowego składającego się z rezystora pełniącego funkcję konwertera prąd na napięcie i z czujnika impedancji pojedynczym impulsem prostokątnym o czasie trwania T bezpośrednio...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls
PublikacjaTwo different type of electrodes, boron-doped diamond electrode (BDD) and boron-doped carbon nanowalls (B:CNW) electrode, were used for the electrochemical determination of paracetamol using the cyclic voltammetry and the differential pulse voltammetry in phosphate buffered saline, pH = 7.0. The main advantage of these electrodes is their utilization without any additional modification of the electrode surface. The peak current...
-
space-vector pulse width modulation for three-level npc converter with the neutral point voltage control
PublikacjaPrzedstawiono strategię modulacji PWM dla trójpoziomowych falowników NPC z predykcją i kompensacją asymetrii rozkładu napięcia na kondensatorach obwodu pośredniczącego
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Experimental investigation of the weight averaging of pulse frequency modulated sensor output signal
Dane BadawczeThe research aims to practically verify the results of theoretical analysis and simulations of the efficiency of weight averaging of pulse frequency modulated signal. For this purpose, a suitable test stand was built, and the control software in the LabVIEW environment was prepared. Then, a series of experiments were carried out to process and analyze...
-
Medical Science Pulse
Czasopisma -
Melamine-modified boron-doped diamond towards enhanced detection of adenine, guanine and caffeine
PublikacjaThis work describes the electrochemical method of boron-doped diamond (BDD) modification by poly-melamine to obtain organic film. The detection of adenine, guanine and caffeine were carried out by differential pulse wave voltammetry. The poly-melamine modified B-NCD electrodes exhibit excellent activity towards the electrochemical oxidation of all examined analytes. The poly-melamine modified BDD electrodes in all measurements...
-
The voltage across and current through the RC model object tested using pulse excitation in impedance spectroscopy measurement method
Dane BadawczeThe raw data (voltage across and current through RC model object ) obtained using pulse excitation EIS impedance spectroscopy measurement method. The data was acquired using 12-bit ADC (LTC1420) with sampling frequency changed in time segments. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. For...
-
A multi-pulse diode rectifier with a coupled three-phase reactor and additional small shunt active power filter
Publikacja -
Supply system based on the 18-pulse diode rectifier with coupled reactors and integrated with the series active power filter
Publikacja -
Temporal fine structure of all-normal dispersion fiber supercontinuum pulses caused by non-ideal pump pulse shapes
Publikacja -
Jacek Stefański prof. dr hab. inż.
OsobyJacek Stefański ukończył studia na Wydziale Elektroniki Politechniki Gdańskiej (PG) w 1993 r. W 2000 r. uzyskał stopień doktora nauk technicznych w dyscyplinie telekomunikacja, w 2012 r. stopień doktora habilitowanego, natomiast w 2020 r. tytuł profesora nauk inżynieryjno-technicznych. Obecnie pracuje na stanowisku profesora w Katedrze Systemów i Sieci Radiokomunikacyjnych (KSiSR) PG. W latach 2005-2009 był zatrudniony w Instytucie...
-
Konfrontowanie reprezentatywnych struktur spektralnych odpowiedzi impulsowej kanału głosowego [Confronting representative spectral structures of vocal tract pulse responses]
Publikacja -
Safety Analysis for the Operation Process of Electronic Systems Used Within the Mobile Critical Infrastructure in the Case of Strong Electromagnetic Pulse Impact
Publikacja -
Characterization and properties of low-friction, multilayered Cr-doped diamond-like carbon coatings prepared by pulse biased filtered cathodic arc deposition
Publikacja -
A Novel Electrochemical Sensor Based on Graphene Oxide Nanosheets and Ionic Liquid Binder for Differential Pulse Voltammetric Determination of Droxidopa in Pharmaceutical and Urine Samples
Publikacja -
Simulation of the weight averaging of pulse frequency modulated sensor output signal
Dane BadawczeThe aim of the research is investigation of the efficiency of weight averaging of pulse frequency modulated signal. It was shown that from the point of view of the reduction of the sampling error the best are polynomial weighing functions, for which the maximum of this component error decreases proportionally to the appropriate power of the number of...
-
Pulse-Modulated Radio-Frequency Alternating-Current-Driven Atmospheric-Pressure Glow Discharge for Continuous-Flow Synthesis of Silver Nanoparticles and Evaluation of Their Cytotoxicity toward Human Melanoma Cells
Publikacja -
Poly-L-Lysine-modified boron-doped diamond electrodes for the amperometric detection of nucleic acid bases
PublikacjaBoron-doped diamond (BDD) is a very promising supporting material used in the construction of biosensors for molecular recognition. The direct immobilization of structurally-organized huge molecules, such as poly-L-Lysine (PLL) provides the possibility of determining organic molecules, e.g. nucleic acid bases (e.g. adenine, guanine) or peptides and proteins. This paper describes the direct method for chemical and electrochemical...
-
Measurements of ultrasonic bulk and guided wave propagation in additively manufactured cubes and plates obtained by ultrasonic pulse velocity analyzer and scanning laser vibrometry
Dane BadawczeThe DataSet contains the results of measurements of ultrasonic wave propagation in additively manufactured samples made of polylactic acid (PLA). Three types of raster angles in two consecutive layers were assumed: 0°/90° (#1), 45°/-45° (#2) and 90°/90° (#3) with respect to the x-axis. For each printing variants a cubic sample (#C1-3) with dimensions...
-
Exhaled nitric oxide in smokers and former smokers with chronic obstructive pulmonary disease
Publikacja -
Simulation of signal acquisition from a rotary flowmeter
Dane BadawczeThe dataset contains results of simulation measuring the flow of homogeneous substances by rotational flow meter: a moment of impulse at the output of flow meter, time between successive pulses, number of pulses counted from standard generator and relative error of measurement.
-
Output voltage, current and DC-link voltages under SVPWM, experimental results
Dane BadawczeThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The comparison studies between proposed Space Vector Pulse-Width...
-
Rheological and compressive strength (ultrasonic pulse method) properties of cement pastes containing iron oxide (Fe3O4) nanoparticles
Dane BadawczeRheological data of cement pastes containing different replacement levels of cement with iron oxide nanoparticles deterimined using MCR 301 (Anton Paar) stress-imposed rheometer, equipped with calibrated helicoidal geometry
-
Adaptacja akustyczna pomieszczenia wykładowego - studium przypadku
PublikacjaW niniejszej pracy przedstawiono analizę rozkładu pola akustycznego sali wykładowej znajdującej się w budynku Wydziału Elektroniki i Telekomunikacji Politechniki Gdańskiej. Badania przeprowadzono metodą pomiarową oraz symulacyjną z wykorzystaniem programu Odeon. Wybór parametrów oceny akustyki wnętrz sugerowany jest wymaganiami stawianymi pomieszczeniom lekcyjnym z zaznaczeniem multimedialnego charakteru wykładów prowadzonych...
-
Images revealing the effect of local femtosecond laser ablation of conductive poly(lactic acid) 3D printed electrodes
Dane BadawczeThe dataset reveals the images of the femtosecond laser (FSL) ablation at the surface of commercially available carbon black-filled poly(lactic acid) 3D printed electrode. The process is used for the increase of the charge transfer of this electrode in electrochemical studies.
-
Sertoli cell tumor, NOS - Male, 66 - Tissue image [9160729581051131]
Dane BadawczeThis is the histopathological image of TESTIS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sertoli cell tumor, NOS - Male, 52 - Tissue image [9070730015331601]
Dane BadawczeThis is the histopathological image of TESTIS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Zastosowanie wyłącznika bezpiecznikowego do formowania impulsu wielkiej mocy
PublikacjaW wielu układach fizycznych i technicznych konieczne jest wytwarzanie impulsów wielkiej mocy o krótkim czasie trwania (rzędu ułamków µs). Impulsy te uzyskuje się stosując układy formujące zasilane ze źródła impulsowego wielkiej mocy, o długim czasie trwania impulsu, rzędu kilkudziesięciu µs. Jednym z układów formujących jest bezpiecznik wyłącznikowy. W pracy metodą symulacyjną badano wpływ parametrów bezpiecznika wyłącznikowego...
-
Output voltage, current and DC-link voltages under SPWM, experimental results
Dane BadawczeThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The Carrier-Based Pulse-Width Modulation (CBPWM) technique was...
-
Hybrid Modulation for Modular Voltage Source Inverters with Coupled Reactors
PublikacjaThis paper proposes and discusses a concept of a hybrid modulation for the control of modular voltage source inverters with coupled reactors. The use of coupled reactors as the integrating elements leads to significant reduction in the size and weight of the circuit. The proposed modulation combines novel coarsely quantized pulse amplitude modulation (CQ-PAM) and innovative space-vector pulse width modulation (SVPWM). The former...
-
Dual drive control under SVPWM, experimental results
Dane BadawczeThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The analysis includes the behaviour of the drive system, examining the dynamic system response to speed and angle changes, and encompassing data...
-
Time domain model of the resonance-based electromagnetic pulses emission system
PublikacjaIn the literature, the emission properties of the electromagnetic field pulse systems based on high voltage antennas (HVR) have been widely described. In order to increase the emission efficiency by extending duration and increasing amplitude of the impulse it is possible to use a resonance system tuned to the parameters of the signal shaped in the pulse forming circuit. The synthesis of a time-domain simulation model of a complex...
-
The forming and emission of high power electromagnetic pulses
PublikacjaAn impulse energy source, a power conditioning system and an electromagnetic field emitter are essential to generate an electromagnetic field pulse (EMFP) with a specific frequency bandwidth. Selected simulation results for a power conditioning system consisting of a fuse opening switch and a paraboloidal electromagnetic emitter have been presented in this article. The synthetic system examined in the simulation is powered by an...
-
Modular multipulse voltage source inverters with integrating coupled reactors
PublikacjaA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...
-
The Influence of Laser Alloying of Ti13Nb13Zr on Surface Topography and Properties
PublikacjaThe laser alloying is a continually developing surface treatment because of its significant and specific structuration of a surface. In particular, it is applied for Ti alloys, being now the most essential biomaterials` group for load-bearing implants. The present research was performed on the Ti13Nb13Zr alloy subject to laser modification in order to determine the treatment effects on surface topography and its some mechanical...
-
Blood Pressure Estimation Based on Blood Flow, ECG and Respiratory Signals Using Recurrent Neural Networks
PublikacjaThe estimation of systolic and diastolic blood pressure using artificial neural network is considered in the paper. The blood pressure values are estimated using pulse arrival time, and additionally RR intervals of ECG signal together with respiration signal. A single layer recurrent neural network with hyperbolic tangent activation function was used. The average blood pressure estimation error for the data obtained from 21 subjects...
-
The forming and emission of high power electromagnetic pulses
PublikacjaAn impulse energy source, a power conditioning system and an electromagnetic field emitter are essential to generate an electromagnetic field pulse (EMFP) with a specific frequency bandwidth. Selected simulation results for a power conditioning system consisting of a fuse opening switch and a paraboloidal electromagnetic emitter have been presented in this article. The synthetic system examined in the simulation is powered by...
-
Estimating Intercept Range of Silent Sonar
PublikacjaWhen used in military application, sonars should ensure secretiveness. There is some evidence suggesting that silent sonars have a significant advantage over pulse sonars in the respect. If improved, the secretiveness of silent sonar translates into the distance over witch its soundings signal are detected by intercept sonars. The article gives estimated distances for far, medium, and short range sonars operating in the oceans...
-
Raman spectroscopy analysis of poly(lactic acid)-carbon black composite treated by femtosecond laser
Dane BadawczeThe dataset contains the Raman spectroscopy measurements of commercially available carbon black-filled poly(lactic acid) 3D printed electrodes after femtosecond laser ablation. These results were utilized in the manuscript published in Electrochimica Acta: 10.1016/j.electacta.2022.140288
-
A concept of software extension of 3D low-PRF radar systems to 4D semi-medium-PRF radar systems
PublikacjaWe present a concept of software modification of three-dimensional (3D) radar systems, designed to work in the low pulse repetition frequency mode, that equips them with the ability to estimate the radial velocity and to properly measure the range of targets that are detected outside the radar’s instrumented range. Despite the fact that the proposed modifications are designed so as to require only minor changes in software, they...
-
Remote Estimation of Video-Based Vital Signs in Emotion Invocation Studies
PublikacjaAbstract— The goal of this study is to examine the influence of various imitated and video invoked emotions on the vital signs (respiratory and pulse rates). We also perform an analysis of the possibility to extract signals from sequences acquired with cost-effective cameras. The preliminary results show that the respiratory rate allows for better separation of some emotions than the pulse rate, yet this relation highly depends...
-
Ultrashort Opposite Directed Pulses Dynamics with Kerr Effect and Polarization Account
PublikacjaWe present the application of projection operator methods to solving the problem of the propagation and interaction of short optical pulses of different polarizations and directions in a nonlinear dispersive medium. We restrict ourselves by the caseof one-dimensional theory, taking into account material dispersion and Kerr nonlinearity. The construction of operators is delivered in two variants: for the Cauchy problem and for the...
-
Propagation of acoustic pulses in some fluids with yield stress
PublikacjaThis study is devoted to the derivation of approximate equations governing acoustic pulses in flows with yieldstress, including some time-dependent flows with a slow dependence on time of yield stress and apparent viscosity. Themodeling of yield stress and apparent viscosity in the vicinity of a zero deformation rate allows us to consider a thixotropicfluid as a Bingham plastic with coefficients that are dependent on time. The...
-
Cross-talk Between the Heart and Arteries in Older 65+ Adults
PublikacjaRegulatory synchronization between the heart and the arterial walls is essential for optimal blood delivery to tissues. We investigated functional coherence between heart rhythm and aortic wall compliance in 30 volunteers aged 65 – 74. ECG and carotid and iliac pulse-wave were recorded and digitized at 2 kHz. Carotid-femoral pulse-wave transit time (cfTT) which reflex aortic compliance was assessed using the intersecting tangent...
-
Caffeine detection using CB-PLA electrode after Nd:YAG laser ablation in He atmosphere
Dane BadawczeThe dataset contains electrochemical studies in form of cyclic voltammetry (CV) and differential pulse voltammetry (DPV) of laser-activated 3D printed CB-PLA electrodes. The ablation of the 3D-printed CB-PLA electrodes was carried out using a pulsed LaserBlast 500 Nd:YAG laser (Quantel, France) operating at 1064 nm and a 6 ns pulse duration.
-
Partial PLA composite surface activation by femtosecond laser ablation
Dane BadawczeThe dataset contains the studies on electrochemical activity of PLA composite (commercially available CB-PLA Protopasta), which was 3D printed in a form of 1x1cm electrodes. The electrodes were submitted to femtosecond laser ablation operating with different parameters. These were: gas atmosphere (He or air, data in different subfolders), the percentage...
-
A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux
PublikacjaIn this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...
-
Control strategy for the multilevel cascaded H-bridge converter
PublikacjaThe paper presents the control strategy for Cascaded H-bridge (CHB) converter . The converter output voltage using Space-Vector Pulse Width Modulation (SV-PWM) strategy is controlled. The DC-link voltages are controlled by appropriate choice of H-Bridges and appropriate choice of active and passive vectors.
-
Enhanced Remote Control Providing Medical Functionalities
PublikacjaThis paper presents the enhanced remote control and its role in pervasive healthcare in the home. The device was equipped with health-related measurement modules and a message-processing unit. Preliminary results are presented for monitoring of a pulse, hand tremors, grip forces, and for self evaluation procedures. The interaction of the device with the smart environment is presented and discussed.
-
Electrodeposited Biocoatings, Their Properties and Fabrication Technologies: A Review
PublikacjaCoatings deposited under an electric field are applied for the surface modification of biomaterials. This review is aimed to characterize the state-of-art in this area with an emphasis on the advantages and disadvantages of used methods, process determinants, and properties of coatings. Over 170 articles, published mainly during the last ten years, were chosen, and reviewed as the most representative. The most recent developments...
-
Studying the Effect of Working Conditions on WEDM Machining Performance of Super Alloy Inconel 617
PublikacjaWire electrical discharge machining (WEDM) has been for many years a precise and efficient non-conventional manufacturing solution in various industrial applications, mostly involving the use of hard-to machine materials like, among other, the Inconel super alloys. The focus of the present study is on exploring the effect of selected control parameters, including pulse duration, pulse-off time and the dielectric flow pressure on...
-
Femtosecond Er-doped fiber laser source tunable from 872 to 1075 nm for two-photon vision studies in humans
PublikacjaWe report the development of a widely-tunable femtosecond fiber laser system and its application for two-photon vision studies. The source is based on an Er-doped fiber laser with spectral shift up to 2150 nm, followed by a second harmonic generation module to generate a frequency-doubled beam tunable from 872 to 1075 nm. The source delivers sub-230 fs pulses with nearly-constant duration over the entire tuning range, with output...
-
The data exchange between smart glasses and healthcare information systems using the HL7 FHIR standard
PublikacjaIn this study we evaluated system architecture for the use of smart glasses as a viewer of information, as a source of medical data (vital sign measurements: temperature, pulse rate, and respiration rate), and as a filter of healthcare information. All activities were based on patient/device identification procedures using graphical markers or features based on visual appearance. The architecture and particular use cases were implemented...
-
Radar time budget optimization subject to angle accuracy constraint via cognitive approach
PublikacjaThe problem of minimizing dwell time in multifunction phased array radar is considered. Target of interest is assumed to fluctuate according to a generalization of Swerling family and the parameters of fluctuation model are assumed to be known. The a'priori position of the target is uncertain. Optimization, whose variables include pulse count and array transmit beampattern, is carried out subject to achieving a desired accuracy...
-
Gate Driver with Overcurrent Protection Circuit for GaN Transistors
PublikacjaThe improvement of the gate driver for GaN transistor is presented in this paper. The proposed topology contains the overcurrent protectionwith the two-stage turning off and independent control of turn on and off time of the GaN transistor. The operation of driver and its application in thehalf-bridge converter are described using both simulation and prototype measurements. The overcurrent protection was tested in Double Pulse...
-
Cichy sonar - stan aktualny i perspektywy
PublikacjaW zastosowaniach militarnych często istnieje potrzeba prowadzenia obserwacji w sposób skryty za pomocą urządzeń emitujących sygnały trudne do przechwycenia przez przeciwnika. Rozwiązania stosowane w cichych radarach stanowiły punkt wyjścia do opracowania cichego sonaru. Prace nad projektem rozpoczęto na Politechnice Gdańskiej w roku 2010 w ramach Grantu NCBiR i są one dalej kontynuowane. W celu zachowania w cichym sonarze warunków...
-
Methods of measurement signal acquisition from the rotational flow meter for frequency analysis
PublikacjaOne of the simplest and commonly used instruments for measuring the flow of homogeneous substances is the rotational flow meter. The main part of such a device is a rotor (vane or screw) rotating at a speed which is the function of the fluid or gas flow rate. A pulse signal with a frequency proportional to the speed of the rotor is obtained at the sensor output. For measurements in dynamic conditions, a variable interval between...
-
Continuous blood pressure monitoring by photoplethysmography - signal preprocessing requirements based on blood flow modelling
PublikacjaObjective. The aim of the study is to investigate the effect of the signal sampling frequency and low-pass filtering on the accuracy of the localisation of the fiducial points of the photoplethysmographic signal (PPG), and thus on the estimation of the blood pressure (i.e. the accuracy of the estimation). Approach. Statistical analysis was performed on 3,799 data samples taken from a publicly available database. Four PPGfiducial...
-
Narrowband Transmission Quality in Presence of Modified IEEE 802.15.4a UWB Signal
PublikacjaThis paper presents results of measurement of narrowband transmission quality in presence of impulse radio UWB interference. In the first part of paper, unmodified IEEE 802.15.4a IR UWB signal is used. Then some modification of transmitted pulse sequence is proposed, which allow to reduce UWB power spectral density at frequency of narrowbandtransmission. Finally narrowband transmission quality in presence of modified ultrawideband...
-
Eksperymentalna analiza modalna stojanów silników indukcyjnych
PublikacjaW artykule zaprezentowano technikę pomiarów i wyniki obliczeń postaci drgań własnych badanego stojana silnika indukcyjnego klatkowego. Przedstawiono również teoretyczne podstawy zastosowanej techniki obliczeniowej. Jako narzędzie akwizycji danych wykorzystano pomiarowy system PULSE firmy Brüel&Kjær, a w celu przeprowadzenia koniecznych obliczeń oraz wizualizacji wyników wykorzystano środowisko Matlab.
-
Narrowband Transmission Quality in Presence of Modified IEEE 802.15.4a UWB Signal
PublikacjaThis paper presents results of measurement of narrowband transmission quality in presence of impulse radio UWB interference. In the first part of paper, unmodified IEEE 802.15.4a IR UWB signal is used. Then some modification of transmitted pulse sequence is proposed, which allow to reduce UWB power spectral density at frequency of narrowband transmission. Finally narrowband transmission quality in presence of modified ultrawideband...
-
A compact smart sensor based on a neural classifier for objects modeled by Beaunier's model
PublikacjaA new solution of a smart microcontroller sensor based on a simple direct sensor-microcontroller interface for technical objects modeled by two-terminal networks and by the Beaunier’s model of anticorrosion coating is proposed. The tested object is stimulated by a square pulse and its time voltage response is sampled four times by the internal ADC of microcontroller. A neural classifier based on measurement data classifies the...
-
A method of self-testing of an analog circuit terminated by an ADC in electronic embedded systems controlled by microcontrollers
PublikacjaA new self-testing method of analog parts terminated by an ADC in electronic embedded systems controlled by microcontrollers is presented. It is based on a new fault diagnosis method based on on-line (i.e. during measurement), transformations of voltage samples of the time response of a tested part to a square pulse - onto localization curves placed in the measurement space. The method can be used for fault detection and single...
-
Samotestowanie toru analogowego ze wzmacniaczem w pełni różnicowym w elektronicznych systemach wbudowanych sterowanych mikrokontrole-rami
PublikacjaPrzedstawiono nową metodę samotestowania toru analogowego opartego na wzmacniaczu w pełni różnicowym w elektronicznych systemach wbu-dowanych sterowanych mikrokontrolerami. Bazuje ona na nowej metodzie diagnostycznej opartej na przekształceniu transformującym próbki odpo-wiedzi czasowej badanej części analogowej na pobudzenie "ujemnym" impulsem prostokątnym na wejściu Vocm na krzywe identyfikacyjne w przestrzeni pomiarowej. Metoda...
-
Analysis of the possibility of creep damage detection in T24 heat resistant steel with the help of magnetic nondestestructive testing methods
PublikacjaThe paper presents the result of an analysis of applicability of various electromagnetic methods of nondestructive evaluation for creep damage detection in a novel heat resistant steel - T24 grade. Two sample sets, cut out from membrane wall tubes, were investigated – the as-delivered one and another exploited for 36,000 h in a power plant. There are described results of magnetic hysteresis loops B(H), Barkhausen noise (BN) and...
-
Long Distance Vital Signs Monitoring with Person Identification for Smart Home Solutions
PublikacjaAbstract— Imaging photoplethysmography has already been proved to be successful in short distance (below 1m). However, most of the real-life use cases of measuring vital signs require the system to work at longer distances, to be both more reliable and convenient for the user. The possible scenarios that system designers must have in mind include monitoring of the vital signs of residents in nursing homes, disabled people, who...
-
FFT spectrum based matching algorithm for activedynamic thermography
PublikacjaIn Active Dynamic thermography (ADT) sequences of consecutive temperature distributions are analyzed. In biomedical applications of ADT, the problems of a patient's movements in front of a thermal camera should be eliminated before data analysis. Complete mechanical stabilization of the patients is impossible due to natural voluntary and involuntary moves caused by pulse breathing, etc. This paper presents a simple and efficient...
-
Application of the laser diode with central wavelength 975 nm for the therapy of neurofibroma and hemangiomas
PublikacjaThis paper presents newly developed dermatological laser (with central wavelength 975 nm) for application in therapies requiring deep penetration of tissue, e.g. cutaneous (dermal) neurofibroma (Recklinghausen disease) and hemangiomas. This laser can work either in pulse or continues wave mode. Laser radiation is transmitted toward the application region by optical fiber with a diameter of 0.6 mm. The compact design of the laser...
-
Scanning electrochemical micrographs of poly(lactic acid) 3D printed electrodes ablated by femtosecond laser
Dane BadawczeThe dataset contains the scanning electrochemical micrographs of the femtosecond laser (FSL) ablation at the surface of commercially available carbon black-filled poly(lactic acid) 3D printed electrode. The process is used for the increase of the charge transfer of this electrode in electrochemical studies.
-
DC-link voltage balancing in cascaded H-Bridge converters
PublikacjaIn the paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches...
-
Multipulse inverter structures with low voltage distortion
PublikacjaA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...
-
Zastosowanie sieci neuronowych do detekcji impulsów o znanym kształcie w obecności silnego szumu i trendu
PublikacjaDetekcja impulsów w odebranym sygnale radiowym, zwłaszcza w obecności silnego szumu oraz trendu, jest trudnym zadaniem. Artykuł przedstawia propozycje rozwiązań wykorzystujących sieci neuronowe do detekcji impulsów o znanym kształcie w obecności silnego szumu i trendu. Na potrzeby realizacji tego zadania zaproponowano dwie architektury. W pracy przedstawiono wyniki badań wpływu kształtu impulsu, mocy zakłóceń szumowych oraz trendu...
-
A New Three-Dimensional Space Vector Modulation for Multilevel Four-Leg Converters Based on the Shape Functions of Tetrahedral Element
PublikacjaThe paper proposes a new three-dimensional space vector pulse-width modulation (3D-SVPWM) algorithm for multilevel four-leg converters. The proposed PWM duty cycle calculation is based on the shape functions of the threedimensional tetrahedral finite elements. The algorithm ensures synthesis of accurate and undistorted output voltages even under significant imbalance or ripple in the DC-link voltages. At the same time, the algorithm...