Wyniki wyszukiwania dla: QUALITY MONITORING
-
Innovative Solutions in Surface Water Quality Monitoring
PublikacjaIn 2010 a project entitled "Integrated Support System for Management and Protection of Water Dam Reservoir (ZiZOZap)” was initiated, to aid solving water management problems on a river and dam reservoir formed on it. An innovative system of continuous monitoring was created, that encompassed selected physical and chemical parameters of river and lake waters in three chosen sites. This article presents a selection of results, that...
-
Toward the next generation of air quality monitoring: Mercury
PublikacjaMercury is a global pollutant that is ubiquitous in the environment. Enrichment of mercury in the biosphere as the result of human activities and subsequent production of methylmercury (MeHg) has resulted in elevated concentrations in fish, wildlife and marine mammals globally. Elemental mercury (Hg0) is the most common form of mercury in the atmosphere, and the form that is most readily transported long distances from its emission...
-
Quality monitoring of therapeutic processes in small treatment center for children
PublikacjaW artykule przedstawiono specyfikę oraz opis zasad nadzorowania procesów terapeutycznych w ramach systemu zarzadzania jakością w małej placówce służby zdrowia.
-
Poland: Quality Monitoring of Therapeutic Processes in a Small Treatment Center for Children
PublikacjaThis article presents the case of the first ISO 9001:2000-certified small healthcare organization (the Center for Therapy and Rehabilitation) providing therapeutic and rehabilitation services for disabled children in Northern Poland. Elements of the process-oriented healthcare quality system implementation, initial benefits, and the organization's quality system structure and process descriptions are described. Particular attention...
-
The applicability of low-cost PM10 sensors for atmospheric air quality monitoring
PublikacjaDescribed in this work are the results of field tests carried out in the Tricity Agglomeration between 01 April 2018 and 30 June 2018 in order to evaluate the usefulness of low-cost PM10 sensors in atmospheric air quality monitoring. The results were juxtaposed with the results obtained using reference methods. The results were validated based on the measurement uncertainty as described in...
-
Passive sampling as a tool for obtaining reliable analyticalinformation in environmental quality monitoring
PublikacjaSpośród technik pobierania próbek analitów technika dozymetrii pasywnej wydaje się być interesującą alternatywą w stosunku do powszechnie stosowanych technik dynamicznych. Dozymetria pasywna łączy w sobie etap pobierania próbki z etapem izolacji i wzbogacania analitów, które są zatrzymywane w odpowiednim medium zatrzymującym. Prowadzi to do znacznego uproszczenia operacji analitycznych wykonywanych in situ. W odróżnieniu od aktywnych...
-
Application of passive sampling techniques as a usable tool in the field of environmental quality monitoring
PublikacjaAnalysis of literature data published for the past 20 years leads to the conclusion, that passive sampling technique has been developing very quickly and is commonly used in the field of monitoring pollutants in air, water and soil environment. The popularity of application of passive sampling techniques in analytical and environmental chemistry results from its many advantages e.g.: Simplicity in use, low costs of exploitation,...
-
REAL-TIME VOICE QUALITY MONITORING TOOL FOR VOIP OVER IPV6 NETWORKS
PublikacjaThe primary aim of this paper is to present a new application which is at this moment the only open source real-time VoIP quality monitoring tool that supports IPv6 networks. The application can keep VoIP system administrators provided at any time with up-to-date voice quality information. Multiple quality scores that are automatically obtained throughout each call reflect influence of variable packet losses and delays on voice...
-
Network design for surface water quality monitoring in a road construction project using Gamma Test theory
PublikacjaRoad construction has a negative environmental impact on the surrounding aquatic environment, requiring the continuous monitoring of surface water quality. Here, optimization of the water quality monitoring network (WQMN) is an essential step in supporting the sustainable development of road construction projects. This study introduces Gamma Test theory (GTT) as a practical method for optimizing the WQMN of surface waters during...
-
Is the soil quality monitoring an effective tool in consumers’ protection of agricultural crops from cadmium soil contamination?—a case of the Silesia region (Poland)
Publikacja -
Current air quality analytics and monitoring: A review
PublikacjaThis review summarizes the different tools and concepts that are commonly applied in air quality monitoring. The monitoring of atmosphere is extremely important as the air quality is an important problem for large communities. Main requirements for analytical devices used for monitoring include a long period of autonomic operation and portability. These instruments, however, are often characterized by poor analytical performance....
-
Monitoring and diagnosis of quality and quantity in drinking water systems.
PublikacjaArtykuł przedstawia nowe podejście do inteligentnego monitorowania oraz diagnostyki Systemu Wodnego (WS) jako problem statusu, warunków operacyjnych oraz rozpoznawania zdarzeń. Oprogramowanie komputerowego systemu monitorowania i diagnostyki zawiera narzędzia dla identyfikacji modeli dyskretnych statusów oraz określenia parametrów ilości i jakości wody dla każdego statusu. Dla każdego stanu decyzje podejmowane są przy użyciu metody...
-
Mobile monitoring system for control of atmospheric air quality
PublikacjaW pracy przedstawiono ruchomy system monitoringu powietrza, który zapewnia możliwość ciągłego pomiaru stężenia takich zanieczyszczeń powietrza jak benzen, tlenek i ditlenek azotu oraz tlenek i ditlenek węgla. Opracowany zestaw pomiarowy może być zainstalowany na rożnych pojazdach (samochód, autobus, ciężarówka).System zbudowany jest z zestawu małych przenośnych jednostek pomiarowych (elektroniczne urządzenia pomiarowe, rejestrator...
-
Optimised Allocation of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublikacjaA problem of optimised placement of the hard quality sensors in Drinking Water Distribution Systems for robust quality monitoring is formulated. Two numerical algorithms to solve the problem are derived. The optimality is meant as achieving a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm. The robust estimation algorithm recently developed...
-
Robust Monitoring of Water Quality in Drinking Water Distribution System
PublikacjaThe paper develops a novel open loop set bounded observer for robust estimation of water quality in DWDS based on the advanced nonlinear quality dynamics model including disinfections by-products (DBPs). The observer utilises a cooperativeness of the quality dynamics model and is computationally efficient, hence applicable to on-line quality monitoring. The simulation results illustrate its good and sustainable performance.
-
Chemometrics in monitoring spatial and temporal variations in drinking water quality
PublikacjaOpracowanie przedstawia wyniki zastosowania wybranych technik chemometrycznych w monitoringu okresowych i powierzchniowych zmian jakości wody pitnej na podstawie wyników oznaczeń chloro i bromopochodnych produktów dezynfekcji wody w 12 dzielnicach w Gdańsku w okresie 1993-2000. Na podstawie wyników analizy podobieństwa lokalizacje podzielono na dwie grupy dzielnic różniących się jakością wody pitnej spowodowanej różnicami wynikającymi...
-
Optimised Robust Placement of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublikacjaA problem of optimised robust placement of the hard quality sensors in Drinking Water Distribution Systems under several water demand scenarios for robust quality monitoring is formulated. Numerical algorithms to solve the problem are derived. The optimality is meant as achieving at the same time a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm...
-
Mobile monitoring system for air quality control along traffic routes = Monitoring zanieczyszczeń wzdłuż ciągów komunikacyjnych
PublikacjaW referacie przedstawiono budowę i zasadę działania mobilnej stacji monitoringu do badania i analizy zanieczyszczeń powietrza atmosferycznego wzdłuż ciagów komunikacyjnych. Przedstawiono również wyniki badań imisji substancji emitowanych z pojazdów poruszających się wzdłuż układu komunikacyjnego Trójmiasta stosując urzadzenie ETL 2000 Bus, zamontowane na dachu samochodu osobowego. Wcześniej, uzyskane wyniki porównano z wynikami...
-
Quality Model for Integrated Security Monitoring and Control in Water Distribution Systems
PublikacjaThis article addresses the problem of drinking water distribution system (DWDS) security in the terms of water quality which in the era of terrorist threat is of high importance to the public. The contribution of this paper is the development of the so called security module to extend a multi-species water quality model. This gives an insight to the situation in DWDS not only under normal operational conditions but also in case...
-
Application of passive sampling technique in monitoring research on quality of atmospheric air in the area of Tczew, Poland.
PublikacjaThis paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. Analytical procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID)...
-
An optimised placement of the hard quality sensors for a robust monitoring of the chlorine concentration in drinking water distribution systems
PublikacjaThe problem of an optimised placement of the hard quality sensors in drinking water distribution systemsunder several water demand scenarios for a robust monitoring of the chlorine concentration is formulatedin this paper. The optimality is understood as achieving a desired trade off between the sensors and theirmaintenance costs and the accuracy of estimation of the chlorine concentration. The contribution of thiswork is a comprehensive...
-
Employment of passive sampling in monitoring indoor air quality in selected residences in a Tri-city area in Poland
PublikacjaTime-weighted average concentrations of selected volatile compounds were measured in chosen residences in a Tri-City area of Poland by means of passive sampling. The results were compared to those obtained by dynamic technique – sorption tubes filled with Tenax TA sorbent. Results obtained by employing the two techniques were similar. Total volatile organic compound (TVOC) parameters were also determined. An attempt was also...
-
Employment of passive sampling in monitoring indoor air quality in selected residences in a Tri-city area in Poland
PublikacjaNa etapie pobierania próbek analitów zastosowano dwie techniki: pasywną - wykorzystującą permeacyjne dozymetry pasywne oraz technikę klasyczną - wykorzystującą rurki sorpcyjne. Wyznaczono sumaryczną zawartość TVOC lotnych związków organicznych.
-
The European Union's Water Framework Directive - A new challenge in monitoring water quality. Ramowa Dyrektywa Wodna Unii Europejskiej - Nowe wyzwanie w monitoringu jakości wody
PublikacjaMonitoring jakości wody polega zwykle na punktowym pobieraniu próbek z użyciem odpowiednich próbników, po którym następuje etap analizy w celu określenia stężenia zanieczyszczeń. Pomimo wielu zalet, metoda ta ma ograniczenia w zakresie badania rozkładu czasowego i przestrzennego zanieczyszczeń oraz w zakresie oceny biodostępności zanieczyszczeń. Wdrożenie Ramowej Dyrektywy Wodnej (2000/60/EC)w krajach Unii Europejskiej będzie wymagało...
-
The Quality of Life and Satisfaction with Continuous Glucose Monitoring Therapy in Children under 7 Years of Age with T1D Using the rtCGM System Integrated with Insulin Pump—A Caregivers Point of View
Publikacja -
Remote Monitoring of Environmental Pollutants
PublikacjaAtmospheric air quality is one of the key factors influencing human health. Air quality evaluation is not an easy task as the atmosphere is a complex system subjected to continuous changes in time. Observed progress in the development of measurement devices and technologies is fundamental for acquisition of more reliable information about condition and quality of atmospheric air. Unfortunately, this process leads to an increase...
-
Air Pollution: Monitoring
PublikacjaThe entry presents an overview of the issues in the field of air pollution monitoring. At the beginning, the general objectives of air monitoring, ambient air quality standards for so-called criteria pollutants, and their sources are discussed. In the next part, both analytical methods and instruments for monitoring of ambient air and stack gases are briefly presented. Additionally, other approaches used in air pollution monitoring,...
-
The Role of Thermal Monitoring in Cardiosurgery Interventions
PublikacjaThe results of a research project devoted to the analysis of the value of IR-thermal imaging in monitoring the quality of cardiosurgery interventions are presented. The role of the ADT is underlined.
-
Evaluation of the Electronic Nose Used for Monitoring Environmental Pollution
PublikacjaAir pollution is a one of the major concern of civilized world, which has a significant impact on human health and the environment. Recent studies highlight that the exposure to polluted air can increase the incidence of diseases and deteriorate the quality of life. Hence, it is necessary to develop tools for real-time air quality monitoring. Electronic-nose systems based on sensors are an interesting and promising technology in...
-
Data on bicycle traffic in Gdansk paired with weather and air quality data
Dane BadawczeThe file contains data on bicycle traffic registered by counting stations loacted in Gdańsk in the years 2013-2020. The data are paired with weather and air quality data from Gdansk collected for the same period. The data is described below:
-
Selecting wells for an optimal design of groundwater monitoring network based on monitoring priority map: A Kish Island case study
PublikacjaThis paper presents a novel approach, i.e. a combination of gamma test and monitoring priority map, for optimal design of groundwater monitoring network (GMN) by considering the cumulative effects of industries, human activities, and natural factors on the groundwater quality. The proposed method was successfully applied to design an optimal network for groundwater salinity monitoring on Kish Island, Persian Gulf. The priority...
-
Data on bicycle traffic in Lodz (Poland) paired with weather and air quality data
Dane BadawczeThe file contains data on bicycle traffic registered by counting stations loacted in Lodz in the years 2016-2019. The data are paired with weather and air quality data from Lodz collected for the same period. The data is described below:
-
Mobile Systems (Portable, Handheld, Transportable) for Monitoring Air Pollution
PublikacjaThe monitoring and analysis of atmospheric air pollutants is a rapidly developing branch of analytical chemistry. The in situ analysis of atmospheric air quality using mobile instrumentation is becoming routine. The article provides information on devices used in various kinds of mobile laboratories. It reviews the portable gas chromatographs and handheld devices used for detecting and determining specific harmful substances in...
-
Evaluation of the Commercial Electrochemical Gas Sensors for the Monitoring of CO in Ambient Air
PublikacjaAir pollution is a growing concern of civilized world, which has a significant impact on human health and the environment. Recent studies highlight that the exposure to polluted air can increase the incidence of diseases and deteriorate the quality of life. Hence, it is necessary to develop tools for real-time air quality monitoring. For air pollution monitoring a wide range of stationary gas and particulate analysers can be used....
-
Electronic Noses for Indoor Air Quality Assessment
PublikacjaThis chapter presents a proposal of the use of electronic noses in the monitoring of indoor air quality. The main focus is put on the detailed characteristics of today’s indoor air quality control methods, the types of pollution in the air, and the development of electronic noses for air testing. Currently, scientists seek methodological and structural solutions that would enable real-time online indoor air control. It has been...
-
On the problem of optimised allocation of water quality sensors and actuators in DWDS
PublikacjaThe problems of water quality sensors and actuators placement in drinking water distribution systems (DWDSs) are addressed as separate, primarily. However, against the background of control systems theory, the nature of DWDSs dynamics indicates that these both problems are interdependent and impact the design of related water quality monitoring and control structures and algorithms. The research work presented in this paper is...
-
Assessment and Optimization of Air Monitoring Network for Smart Cities with Multicriteria Decision Analysis
PublikacjaEnvironmental monitoring networks need to be designed in efficient way, to minimize costs and maximize the information granted by their operation. Gathering data from monitoring stations is also the essence of Smart Cities. Agency of Regional Air Quality Monitoring in the Gdańsk Metropolitan Area (pol. ARMAAG) was assessed in terms of its efficiency to obtain variety of information. The results on one-month average concentrations...
-
Research on Quality Requirements of Data Transmission Services in RSMAD
PublikacjaThe paper presents a results and analysis of research of the quality of service requirements (defined by the QoS attributes) for imaging data transmission services using Radio System for Monitoring and Acquisition of Data from Traffic Enforcement Cameras (in short RSMAD). The paper also presents and discusses results of test on the impact of the size of photos from traffic enforcement cameras on the average transmission time. These...
-
Intelligent monitoring the vertical dynamics of wheeled inspection vehicles
PublikacjaThe problem of intelligent monitoring of the vertical dynamics of wheeled inspection vehicles is addressed. With the independent MacPherson suspension system installed, the basic analysis focuses on the evaluation of the parameters of the so-called quarter car model. To identify a physically motivated continuous description, in practice, dedicated integral-horizontal filters are used. The obtained discrete model, which retains...
-
The protection and monitoring of a distribution piping network for potable water supply
PublikacjaPurpose – The purpose of this paper is to implement the corrosion protection method for steel pipes used in a municipal water-pipe network. Results of an inhibitor protection system installed on the system are presented. Inhibitor protection was required due to the high corrosivity of the water collected by a surface intake, which had resulted in a large number of failures and low water quality, due to the presence of corrosion...
-
Dilemmas associated with the implementation of quality management systems in Polish smaller health care units
PublikacjaThe article presents the considerations and recommendations for the implementation of the process-oriented quality management systems (QMS) in small health care units. As an example, the unit providing services for children with disabilities (therapy and rehabilitation) localized in northern part of Poland have been selected. The essential elements of the implementation of the quality system, taking into account the objectives...
-
Monitoring of Chlorine Concentration in Drinking Water Distribution Systems Using an Interval Estimator
PublikacjaThis paper describes the design of an interval observer for the estimation of unmeasured quality state variables in drinking water distribution systems. The estimator utilizes a set bounded model of uncertainty to produce robust interval bounds on the estimated state variables of the water quality. The bounds are generated by solving two differential equations. Hence the numerical efficiency is sufficient for on-line monitoring...
-
Monitoring of underdeck corrosion by using acoustic emission method
PublikacjaThis paper presents first short characteristics of underdeck corrosion process as well as a problem of its monitoring. Next is described an acoustic emission (AE) method elaborated by Department of Ship Technology , Quality Systems and Material Engineering, Gdańsk University of Technology in cooperation with partners of CORFAT project realized within 7th EU Frame Program . Further are presented short characteristics of the emission...
-
Cellular network quality evaluation at a university campus on the eve of 5G
PublikacjaThanks to the availability of mobile devices and the spread of broadband access around the world, the number of network users continues to grow. This has raised user awareness when it comes to the quality of content they consume. Many service providers and operators focus on monitoring QoN (Quality of Network) and QoS (Quality of Service) parameters, particularly those influenced by bandwidth and latency. However, for most end-users,...
-
Smartphones as tools for equitable food quality assessment
PublikacjaBackground: The ubiquity of smartphones equipped with an array of sophisticated sensors, ample processing power, network connectivity and a convenient interface makes them a promising tool for non-invasive, portable food quality assessment. Combined with the recent developments in the areas of IoT, deep learning algorithms and cloud computing, they present an opportunity for advancing wide-spread, equitable and sustainable food...
-
An interval estimator for chlorine monitoring in drinking water distribution systems under uncertain system dynamics, inputs and chlorine concentration measurement errors
PublikacjaThe design of an interval observer for estimation of unmeasured state variables with application to drinking water distribution systems is described. In particular, the design process of such an observer is considered for estimation of the water quality described by the concentration of free chlorine. The interval observer is derived to produce the robust interval bounds on the estimated water quality state variables. The stability...
-
Interactive information and decision support system for urban and industrial air quality management based on multi-agent system
PublikacjaThis article presents conception of interactive information and decision support system for urban and industrial air quality management. The emphasis of the project is on real-time analysis and multi-media information, and the support of distributed and mobile clients through the Internet. The approach integrates meteorological data and forecasts, air quality and emission monitoring, dynamic 3D simulation modelling and forecasting,...
-
Optoelectronic system for monitoring of thin diamond layers growth
PublikacjaDevelopment of the optoelectronic system for monitoring of diamond/DLC (Diamond-Like-Carbon) thin films growth during mu PA ECR CVD (Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition) process is described. The multi-point Optical Emission Spectroscopy (OES) and Raman spectroscopy were employed as non-invasive optoelectronic tools. Dissociation of H-2 molecules, excitation and ionization of hydrogen...
-
Assessment of wastewater quality indicators for wastewater treatment influent using an advanced logistic regression model
PublikacjaInfluent quality indicators play a significant role in wastewater treatment plant performance due to their correlation with reactor operations and effluent quality. However, selecting a specific/best parameter indicator for predicting influent wastewater quality is one of the challenges in wastewa- ter treatment. This study, therefore, focused on determining suitable variables as influent quality indicators. For this purpose, a...
-
Monitoring of odour nuisance in the Tricity Agglomeration
PublikacjaThe paper describes a principle of operation of odour nuisance monitoring network, which is being designed in the Tricity Agglomeration. Moreover, it presents the preliminary results of an investigation on ambient air quality with respect to odour nuisance in a vicinity of the municipal landfill. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The...