The AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters
Open Research DataThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
The short-term flicker severity level measured in the industrial power system supplying the rolling mill motors
Open Research DataThe dataset presents a short-term flicker severity level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of...
-
A cumulative probability function of instantaneous flicker sensation values measured in the industrial power system supplying the rolling mill motors
Open Research DataThe dataset presents a cumulative probability function CPF of the instantaneous flicker sensation level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage...
-
Nonlinear impedance of as-quenched Bi2VO5.5 glass-ceramic was measured with impedance spectroscopy method at low temperature region
Open Research DataThe nonlinear electrical properties of as-quenched Bi2VO5.5 glass-ceramic was measured by impedance spectroscopy method.
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_004)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Fire Weather Index data for Poland (March – September 2019) based on high-resolution Weather Research and Forecasting Model
Open Research DataThis dataset contains forecasted FWI indices calculated for the period: March 1 - September 30, 2019, based on the meteorological fields derived from the Weather Research and Forecasting Model (WRF) ver. 4.2.1. For each day FWI data with the forecast range equal 24 and 48 hour were stored in GeoTIFF files. In addition, soil moisture and temperature...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_005)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Parameters of land reference points in the Gdynia region and the Free-air anomaly grid of the South Baltic
Open Research DataThe data was registered during the campaign to verify the catalog value of the absolute point coordinates [point 5403 (POLREF-GORA DONAS)] of the national gravimetric control network. The data was recorded in two three-hour stationary measurement campaigns at the following points: Rozewie of the EUREF-POL network, Góra Donas POLREF, and mareograph points...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0010)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_002)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0012)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Vibration data for 1205 EKTN9 bearings
Open Research DataThe data contains measurements of vibration obtained with VIBstand manufactured by EC systems.
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_008)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_003)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_007)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_006)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0011)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_009)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Data from 76- to 81-GHz mmWave Sensor located at S7 road
Open Research DataThe set consists data recorded employing IWR1642 mmWave sensor from Texas Instruments. The purpose of the experiment was to detect vehicles and their speed in real conditions – at S7 road, near Dworek village (54°14'40.0"N 18°59'59.0"E).
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0017)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0021)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0020)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0019)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0024)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K was measured by impedance spectroscopy method.
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0023)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Microscopic examination of the texture of paper products
Open Research DataAtomic force microscopy (AFM) can be used to study the state of the paper fibers with the aim of providing qualitative and semi-quantitative information on degradation and aging. The work [1] reports the results of tests of various paper products subjected to deliberate aging processes under the influence of various factors. Chemical and biological...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
The set of 22 sessions of 14-channel eeg signals recorded during watching pictures
Open Research DataThe data were collected in order to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals collected from 10 persons within 22 sessions, during which 45 different random photos taken from the ImageNet...
-
UAV spectrometer reflectance and leaf area index for vegetation near Gdynia, Poland
Open Research DataReflectance data from the UAV flights with UV-VIS spectrometer along with leaf area index measurements for vegetaion near Gdynia, Poland.
-
Entrepreneurs' intention to use tax relief
Open Research DataThe dataset presents the results of research conducted by the author among Polish entrepreneurs in 2017–2020. The diagnostic survey method was used to collect primary data among enterprises from the SME sector. The measurement instrument was a survey questionnaire developed by the author. This study is a key piece of research. The aim was to examine...
-
API 5L X65 steel - tensile properties in room temperature -10°C, along rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - CMOD-force record in -10°C, along rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - tensile properties in room temperature +20°C, across rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - tensile properties in room temperature -10°C, across rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - CMOD-force record in -10°C, across rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - tensile properties in room temperature +20°C, along rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - fracture documentation of CMOD-force test in -10°C, along rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
The luminescence study of Sr2TiO4:Sm3+ coumpounds.
Open Research DataA luminescent material based on the strontium orthotitanate (Sr2TiO4) matrix doped with 1% of a mole of samarium was obtained using the typical solid-state synthesis method under a neutral atmosphere of nitrogen. The sample was investigated using powder X-ray diffraction (XRD) and several luminescence techniques to study the phase composition, luminescence...
-
API 5L X65 steel - fracture documentation of CMOD-force test in -10°C, across rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
Data obtained by computation for X-ray imaging of grating without magnification using oriented Gaussian beams
Open Research DataThe propagation of X-ray waves through an optical system consisting of grating and X-ray refractive lenses is considered. In this approach, the propagating wave is represented as a superposition of the oriented Gaussian beams. The direction of wave propagation in each Gaussian beam is consistent with the local propagation direction of the X-ray wavefront.
-
Permanent traffic counting stations - Expressway S7 in Gdansk, Poland
Open Research DataThe data includes traffic data from permanent traffic count station located on the expressway S7 in the Tri-City Agglomeration area in Poland. The data covers the 2 months of 2015 (May, October) and one direction of traffic (eastbound).
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Electronic transition dipole moment functions of the second singlet Sigma gerade plus state of the Lithium dimer
Open Research DataElectronic transition dipole moment functions (ETDMF) of the second singlet Sigma gerade plus (2sSg+) state have been calculated for the Lithium dimer. ETDMFs are needed in understanding processes like photodissociation, photoassociation, cooling, and trapping of molecules. The results of the five ETDMFs have been obtained by the nonrelativistic multireference...
-
Electronic transition dipole moment functions of the fifth singlet Sigma gerade plus state of the Lithium dimer
Open Research DataElectronic transition dipole moment functions (ETDMF) of the fifth singlet Sigma gerade plus (5sSg+) state have been calculated for the Lithium dimer. ETDMFs are needed in understanding processes like photodissociation, photoassociation, cooling, and trapping of molecules. The results of the five ETDMFs have been obtained by the nonrelativistic multireference...
-
Electronic transition dipole moment functions of the third singlet Sigma ungerade plus and third triplet Sigma gerade plus states of the Lithium dimer
Open Research DataElectronic transition dipole moment functions (ETDMF) of the third singlet Sigma ungerade plus (3sSu+) and third triplet Sigma gerade plus (3tSg+) states have been calculated for the Lithium dimer. ETDMFs are needed in understanding processes like photodissociation, photoassociation, cooling, and trapping of molecules. The results of the four ETDMFs...
-
Electronic transition dipole moment functions of the second singlet Pi gerade and second triplet Pi gerade states of the Lithium dimer
Open Research DataElectronic transition dipole moment functions (ETDMF) of the second singlet Pi gerade (2sPg) and second triplet Pi gerade (2tPg) states have been calculated for the Lithium dimer. ETDMFs are needed in understanding processes like photodissociation, photoassociation, cooling, and trapping of molecules. The results of the four ETDMFs have been obtained...
-
Electronic transition dipole moment functions of the fifth triplet Sigma ungerade plus state of the Lithium dimer
Open Research DataElectronic transition dipole moment functions (ETDMF) of the fifth triplet Sigma ungerade plus (5tSu+) state have been calculated for the Lithium dimer. ETDMFs are needed in understanding processes like photodissociation, photoassociation, cooling, and trapping of molecules. The results of the five ETDMFs have been obtained by the nonrelativistic multireference...
-
Electronic transition dipole moment functions of the first singlet Sigma gerade plus state of the Lithium dimer
Open Research DataElectronic transition dipole moment functions (ETDMF) of the first singlet Sigma gerade plus (1sSg+) state have been calculated for the Lithium dimer. ETDMFs are needed in understanding processes like photodissociation, photoassociation, cooling, and trapping of molecules. The results of the five ETDMFs have been obtained by the nonrelativistic multireference...