Filters
total: 903
filtered: 873
Search results for: coefficient of active power distribution
-
Machine-learning-based precise cost-efficient NO2 sensor calibration by means of time series matching and global data pre-processing
PublicationAir pollution remains a considerable contemporary challenge affecting life quality, the environment, and economic well-being. It encompasses an array of pollutants—gases, particulate matter, biological molecules—emanating from sources such as vehicle emissions, industrial activities, agriculture, and natural occurrences. Nitrogen dioxide (NO2), a harmful gas, is particularly abundant in densely populated urban areas. Given its...
-
Flow distribution and heat transfer in minigap and minichannel heat exchangers during flow boiling
PublicationThe topic of boiling heat transfer in miniscale geometries has focused the ever increasing interest of researchers in recent years. However, most of the works are related to mini- and microchannels and much less to minigaps. Meanwhile, minigaps allow for more comprehensive experimental studies, i.e. flow visualisations due to the flat, two-dimensional configuration of the flow. The results of the experimental investigations of...
-
Sensitivity analysis as a tool to optimise Human Development Index
PublicationResearch background: Composite indicators are commonly used as an approximation tool to measure economic development, the standard of living, competitiveness, fairness, effectiveness, and many others being willingly implemented into many different research disciplines. However, it seems that in most cases, the variable weighting procedure is avoided or erroneous since, in most cases, the so-called...
-
Effective Formula for Impact Damping Ratio for Simulation of Earthquake-induced Structural Pounding
PublicationStructural pounding during earthquakes may cause substantial damage to colliding structures. The phenomenon is numerically studied using different models of collisions. The aim of the present paper is to propose an effective formula for the impact damping ratio, as a parameter of the impact force model used to study different problems of structural pounding under seismic excitations. Its accuracy has been verified by four various...
-
Possibilities of Phoslock® application to remove phosphorus compounds from wastewater treated in hybrid wetlands
PublicationTreatment wetland technologies for wastewater treatment can be easily applied for removal of all pollutants except phosphorous. They are applicable in a small towns and rural areas, places where conventional wastewater treatment plant cannot properly operate because of common economic constraints. In Poland only the 8% of rural areas are equipped with sewer system, thus treatment wetlands might be an alternative, effective and...
-
Optimized AVHRR land surface temperature downscaling method for local scale observations: case study for the coastal area of the Gulf of Gdańsk
PublicationSatellite imaging systems have known limitations regarding their spatial and temporal resolution. The approaches based on subpixel mapping of the Earth’s environment, which rely on combining the data retrieved from sensors of higher temporal and lower spatial resolution with the data characterized by lower temporal but higher spatial resolution, are of considerable interest. The paper presents the downscaling process of the land...
-
Unlocking the Secrets of River Pollution: Analyzing Organic Pollutants in Sediments—Experimental Study
PublicationUntreated wastewater released into rivers can result in water pollution, the spread of waterborne diseases, harm to ecosystems, contamination of soil and groundwater, as well as air pollution and respiratory problems for nearby humans and animals due to the release of greenhouse gases. The current study aims to investigate the recent input of anthropogenic loads into the rivers using linear alkylbenzene (LAB), which is one of the...
-
Modern power-electronics installations in the Polish electrical power network
PublicationThe paper discusses the most important areas of application of power electronics arrangements in the Polish electrical power system; especially in the distribution system. The examples presented demonstrate both the need for and the purpose of further research and its applications in these fields, as well as indicating the direction of future research, with special consideration given to the research required in Poland. The proposed...
-
Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid
PublicationOne of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...
-
Code development of a DSP-FPGA based control platform for power electronics applications
PublicationThis paper focuses on the implementation of power electronics algorithms in control platforms based on DSP-FPGA. Today’s power electronics technology demands high power computation with high speed interfacing at the same time. The most popular configuration is a DSP for the former and a FPGA for the latter. The main goal of this work was to develop a generic control system for power electronics application, but it is explained...
-
Power electronic transformer based on cascaded H-bridge converter
PublicationIn this paper the control strategy of power electronic transformer (PET) is proposed. The analyzed structure of PET uses two seven-level cascaded H-bridge (CHB) rectifiers. The electrical power of PET is transferred between DC-links of CHB converters using dual-active-bridges (DABs) and low voltage high frequency transformers. The roposed solution allows for controlling the active and reactive power with a low level of harmonic...
-
Voltage and Reactive Power Load Flow Optimization in the Power System Using Fuzzy Logic
PublicationThe paper presents issues related to voltage control in the power system. An original method of reactive power flow optimization is considered, which leads to improved voltages in the power system and reduced active power losses. The optimization method is based on a procedure that employs fuzzy logic and is supported by a gradient search algorithm. The method has been implemented in PLANS software and verified.
-
Simulation Studies of Control Systems for Doubly Fed Induction Generator Supplied by the Current Source Converter
PublicationThe control system for a Doubly Fed Induction Generator (DFIG) supplied by a grid-connected Current Source Converter (CSC) is presented in this paper. Nonlinear transformation of DFIG model to the multi-scalar form is proposed. The nonlinear control strategy of active and reactive power of DFIG is realized by feedback linearization. In the proposed control scheme, the DFIG model and CSI parameters are included. Two Proportional-Integral...
-
Evaluation of VSC Impact on Power System Using Adequate P-Q Capability Curve
PublicationRenewable energy sources, which are becoming increasingly popular, often use a voltage source converter (VSC) for connection to the power system. Assessing the effects of connecting such a source to the power system is essential to ensure the proper operation of the power system and the connected source. For this purpose, it is necessary to know the range of active and reactive power generation by the converter. The authors indicate...
-
Problems of Connecting Wind Farms to the Power System with HV Cables
PublicationThis paper presents problems caused by connecting wind farms to a power system with high voltage cables. The author highlights possible problems with reactive power compensation, depending on the arrangement of the shunt reactor connection and settings of control systems for reactive power and voltage of the wind farm. The paper also discusses issues of increasing active power losses caused by a shunt reactor installation.
-
Time series analysis and impact assessment of the temperature changes on the vegetation and the water availability: A case study of Bakun-Murum Catchment Region in Malaysia
PublicationThe Bakun-Murum (BM) catchment region of the Rajang River Basin (RRB), Sarawak, Malaysia, has been under severe threat for the last few years due to urbanization, global warming, and climate change. The present study aimed to evaluate the time series analysis and impact assessment of the temperature changes on the vegetation/agricultural lands and the water availability within the BM region. For this purpose, the Landsat data for...
-
Effects of biotransport and hydro-meteorological conditions on transport of trace elements in the Scott River (Bellsund, Spitsbergen)
PublicationThe shaping of surface water chemistry in the Svalbard Archipelago is strongly dependent on the geology of the catchment and the process of long-range transport of atmospheric pollutants (LRATP). It was found that the dissolved trace elements in the Scott River, which catchment is characterized by a decreasing degree of glaciation, were of the natural origin (i.a. weathering and dissolution of local geological substratum). The...
-
Modeling of Passive and Forced Convection Heat Transfer in Channels with Rib Turbulators
PublicationThe main goal of the research presented in this paper was the experimental and numerical analysis of heat enhancement and aerodynamic phenomena during air flow in a channel equipped with flow turbulators in the form of properly configured ribs. The use of ribs intensifies the heat transfer and at the same time increases not only the flow resistance but also the energy costs. Therefore, designing modern heat exchangers with optimal...
-
Concentrations of monoaromatic hydrocarbons in the air of the underground car park and individual garages attached to residential buildings
PublicationThe paper describes the characteristics of a two-level underground car park and three individual garages attached to residential buildings, differing by the resident utilization habits, located in North Poland (Tri-City agglomeration area). The strategy of collecting the analyte samples from air in mentioned enclosed areas, concerning the determination of benzene, toluene, ethylbenzene, o-xylene and p,m-xylenes (BTEX) concentrations...
-
Power Hardware-In-the-Loop Approach for Autonomous Power Generation System Analysis
PublicationThe article presents the Power Hardware-In-the-Loop (PHIL) dynamic model of a synchronous generator of 125 kVA for autonomous power generation system analysis. This type of system is typically composed of electrical energy sources in the form of several diesel generator units with synchronous machines, the main distribution switchboard and different loads. In modern power distribution systems, the proposed power management strategies...
-
Interconnection of the Customer-Side Resources Using Single Phase VAPF
PublicationThe paper introduces method for utilization of the customer-side generated energy using single phase voltage active power filter. Structure and control method of the power electronics converter has been described and some simulation results are shown to prove usefulness of this arrangements. Proposed application realizes the following functions: power quality improvement, uninterruptible supplying and energy costs reduction.
-
Synchronous generator model taking into account the non-uniform saturation of the pole shoes
PublicationFor the evaluation of modern electric power systems with regard to their behavior, weight, and reliability a novel modeling and simulation tools have been developed. The paper presents circuit model of synchronous generator taking into account both the non-sinusoidal distribution of the stator and rotor winding, and non-uniform saturation of the pole shoes. This model is suitable for simulation of both salient and no-salient pole...
-
Static Series and Shunt-series PE Voltage-quality Controllers
PublicationAs presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...
-
Ancillary services to grids provided with distributed generation
PublicationThe paper introduces system for utilization of the customer-side generated energy. Additionally system can secure some ancillary services to grids. Those services include: current active filtering, load voltage stabilization and in case of grid voltage faults - uninterruptible load supplying (possible with energy storage device). Presented experimental results confirm flexibility of this arrangement in processes of power delivery...
-
A Paradigm for HV, MV, LV Distribution Grid Development Planning
PublicationIn the literature, including that relating to businesses in the energy (and power) sector, the concept of these organizations’ operating paradigm may be found. The paper discusses the concept of the paradigm, with a focus on the power grid development planning paradigm. Against this background, issues related to energy security and power systems development trends and problems are presented. A new paradigm is proposed for distribution...
-
On the well posedness of static boundary value problem within the linear dilatational strain gradient elasticity
PublicationIn this paper, it is proven an existence and uniqueness theorem for weak solutions of the equilibrium problem for linear isotropic dilatational strain gradient elasticity. Considered elastic bodies have as deformation energy the classical one due to Lamé but augmented with an additive term that depends on the norm of the gradient of dilatation: only one extra second gradient elastic coefficient is introduced. The studied class...
-
Experimental validation of the rolling resistance measurement method including updated draft standard
PublicationThe main objective of ROSANNE is the harmonisation and standardisation of the measurement of skid resistance, noise emission and rolling resistance of road pavements. Regarding rolling resistance characterisation, a draft for standardization of a harmonized procedure for classification of road surfaces across Europe has been prepared within WP3 (deliverable 3.5). The procedure deals with the direct measurement on real roads of...
-
Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym
PublicationZnanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy....
-
Cross-border transmission line configuration influence on the electrical power and energy billing process
PublicationIn 2015 a connection between the Polish and Lithuanian power systems become fully operational. The connection consists of a 400 kV double circuit transmission line and a back-to-back HVDC substation located on the Lithuanian side. A magnetic couplings between the circuits of the transmission line cause that during power transmission a different values of active power losses are observed in both circuits. This situation may cause...
-
Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis
PublicationStarvation, flooding, and dry‐out phenomena occur in polymer electrolyte membrane fuel cells (PEMFCs), due to heterogeneous local conditions, material inhomogeneity, and uneven flow distribution across the single cell active area and in between the individual cells. The impact of the load level and air feed conditions on the performance was identified for individual single cells within a 10‐cell stack. Analysis of the current density...
-
Power Surge Compensator based on a Four Level Diode Clamped Inverter for ship application. Average model
PublicationPaper presents continuous average value model of Power Surge Compensator based on a Four Level Diode Clamped Inverter with super capacitor as a energy storage device. This conditioner is design for power surge or fluctuation elimination, by compensating it with energy stored in ESD. Continuous average value model of multilevel S-PWM has been presented also. Summary of raised problem is a simulation model made in PowerSim Psim 8...
-
Laboratory Load Model Based on 150 kVA Power Frequency Converter and Simulink Real-Time – Concept, mplementation, Experiments
PublicationFirst section of the paper provides technical specification of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is presented. Theoretical considerations based on criteria which load types may be simulated using discussed laboratory setup, are described. As described model contains transformer with thyristor-controlled tap changer,...
-
Selection of main engines for hopper suction dredgers with the use oobability models
PublicationThis paper presents a new original method of selection of main engines for hopper suction dredgers with regard to probabilistic models. It was proposed to use the normal distribution to describe the operational loads of the main receivers. The principles for determination of parameters of load distribution and design power of the main engines were formulated. Lastly, the principles of selection of the size and number of main engines...
-
THE INFLUENCE OF PHASE SHIFTERS ON THE VOLTAGE STABILITY OF CONNECTED POWER SYSTEMS
PublicationThe paper presents the results of simulation tests of connected power systems in which phase shifters were installed on cross-border links. The analysis was carried out in terms of assessing the impact of shifters on node voltage stability. Individual systems were characterized by different balance of active power: deficit or excess. The evaluation of voltage stability was based on the dU/dQ and dU/dP criteria.
-
Współczynniki strat energetycznych w elementach napędu hydrostatycznego
PublicationW każdym układzie napędowym należy zastąpić obraz przepływu mocy opisany dotychczas powszechnie stosowanym wykresem Sankey’a spadku mocy zgodnego z kierunkiem przepływu mocy proponowanym przez autora wykresem wzrostu mocy w układzie przeciwnego do kierunku przepływu mocy. Należy więc opisywać straty i sprawność energetyczną a także pole pracy każdego silnika i układu napędowego jako zależne od wielkości fizycznych niezależnych...
-
Modern Arrangement for Reduction of Voltage Perturbations
PublicationThe contents of this chapter encompass general problems and the most important issues of power-supply-quality improvement in AC systems. In the context of the above, consideration is given to evaluation of bilateral interactions of receivers with an electrical power-distribution system and methods of their reduction. Also are discussed the basis of operation of the most important compensation-filtration devices and their applications...
-
3-phase medium frequency transformer for a 100kW 1.2kV 20kHz Dual Active Bridge converter
PublicationThe article presents a three-phase Medium Frequency Transformer being a part of a 100kW 1.2kV 20kHz Dual Active Bridge DC-DC converter. The transformer design is detailed focusing on winding and core power loss calculation. The high power three-phase MFT prototype is presented. The experimental results include the transformer impedance characteristics, no load test and three-phase DAB full load test waveforms
-
A city is not a tree: a multi-city study on street network and urban life
PublicationChristopher Alexander, a British-American scholar, differentiated an old (natural) city from a new (planned) one by structure. The former resembles a “semilattice”, or a complex system encompassing many interconnected sub-systems. The latter is shaped in a graph-theoretical “tree”, which lacks the structural complexity as its sub-systems are compartmentalized into a single hierarchy. This structural distinction explains why, or...
-
Improving Thermal Insulation Properties for Prefabricated Wall Components Made of Lightweight Aggregate Concrete with Open Structure
PublicationPorous concrete is commonly used in civil engineering due to its good thermal insulation properties in comparison with normal concrete and high compression strength in comparison with other building materials. An extremely porous concrete, called ‘lightweight aggregate concrete with open structure’ (LAC), is used in some German plants to produce prefabricated wall components. They are used mainly in hall buildings, e.g. supermarkets....
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublicationThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters
PublicationThis study presents the structure and the space vector pulse-width modulation (SVPWM) for power electronic transformer (PET) based on two seven-level cascade H-bridge (CHB) inverters. The DC links of CHB inverters are coupled with nine dual-active bridge (DAB) converters with medium-frequency transformers. The DC-link voltages are equalised with two methods – through the control of DAB voltages...
-
Integrated algorithm for selecting the location and control of energy storage units to improve the voltage level in distribution grids
PublicationThis paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing...
-
Estimation of Selected Synchronous Generator Parameters Based on the Gradient Method
PublicationThe authors present a method for the estimation of synchronous generator model parameters using a gradient algorithm. The paper shows an example of model parameter estimation for a turbogenerator and hydrogenerator, based on the generator voltage time responses obtained during an active and reactive power rejection test.
-
50’ Sail Catamaran with Hybrid Propulsion, Design, Theoretical and Experimental Studies
PublicationThe development of modern lithium batteries and propulsion systems now allows the use of complex propulsion systems for vessels of various sizes. As part of the research and implementation project, a parallel hybrid drive system was designed, built and then tested in the laboratory. The experimental studies conducted allowed for the measurements of power, fuel consumption and electric power distribution in various operating modes...
-
Distribution Transformer with Multi-Zone Voltage Regulation for Smart Grid System Application
PublicationThe article presents four concepts of the multi-zone voltage regulation (MZVR) system. It is a combination of a distribution transformer with an on-load tap-changer, for step voltage regulation, and a power electronic converter, dimensioned for a fraction of MZVR power, realizing continuous voltage regulation, supplemented by a special switch, the so-called bypass. This allows voltage regulation at high resolution, wide range and...
-
Voltage profiles improvement in a power network with PV energy sources – results of a voltage regulator implementation
PublicationThe constant increase in the number of photovoltaic (PV) energy sources in distribution networks is the cause of serious voltage problems. The networks built at least a dozen years ago are not provided for the installation of a large number of micro-sources. It happens that the previously properly functioning power networks are not able to provide to consumers power with the required parameters, after installing many PV sources....
-
Experimental test results of an automatic voltage regulator with independent phase voltage controllers
PublicationThe growing number of distributed renewable energy sources and dynamic constant-power loads (e.g. electric vehicle charging stations) pose new challenges for network operators. These changes result in alterations to network load profiles and load flows, leading to greater voltage volatility. One effective solution to these problems can be the use of automatic voltage regulators (AVRs), which stabilize and symmetrize voltage output,...
-
Comparative analysis of three‐phase dual active bridge converter with different transformer topology and modern universal control for DC microgrids
PublicationThe presented work discusses issues related to the use of modern multiphase topologies of Dual Active Bridge (DAB)-type converters. Converters of this type are widely used in most DC microgrid applications. The introduction emphasizes a comparative analysis between single-phase and multi-phase DAB topologies within high-power DC microgrids, delving into their respective advantages, drawbacks, design procedures, and considerations...
-
Estimation of Synchronous Generator and AVR Parameters Based on Gradient and Genetic Methods
PublicationThe author present a method for the estimation of selected synchronous generator model and AVR parameters using a gradient and a genetic algorithm. The paper shows an example of model parameter estimation for a turbogenerator, based on the generator voltage time responses obtained during an active and reactive power rejection test
-
Application capabilities of the maximum distributed generation estimate methodology
PublicationThe paper presents application capabilities of the maximum distributed generation estimate methodology. This subject is an example of solutions to the problem that today face the transmission system operator and distribution system operators, which is related to the high saturation with wind power generation predicted for the near future.