Filters
total: 3189
filtered: 2399
displaying 1000 best results Help
Search results for: SWITCHED CURRENT FILTERS
-
Technical diagnostics and monitoring of traction current collectors
PublicationNew evaluation methods of the technical condition of rolling stock current collectors are proposed in this paper. The method of automatic measurement of the pantograph static force characteristic, realized when the vehicle runs through the test section of the track with especially prepared overhead line height distribution, has been practically implemented by the Polish Railways. The method of testing the slipper spring suspension...
-
Indirect Measurement of Motor Current Derivatives in PMSM Sensorless Drives
PublicationMotor current derivatives contain useful information for control algorithms, especially in sensorless electric drives. The measurement of motor current derivatives in electric motors supplied by voltage source inverter can be performed using di/dt transducers. However, in such a solution additional sensors have to be installed, e.g. Rogowski coils. Another approach is to measure current derivatives indirectly – by oversampling...
-
Remarks on the Subject of Back-Up Protection of Residual Current Devices
PublicationResidual current devices without integral overcurrent protection (RCCBs) are back-up protected by fuses or miniature circuit-breakers (MCBs). If the latter are used, special attention must be given to the coordination between an RCCB and an MCB. This paper indicates probable cases of the aforementioned devices coordination, in which back-up protection of the RCCB is not adequate. A laboratory test has shown that depending on the...
-
Zero-pole approach to computer aided design of in-line siw filters with transmission zeros
PublicationThis paper presents a design of a new type of in-line pseudo-elliptic filters implemented in substrate integrated waveguide(SIW) technology. To realize transmission zeros in in-line topology,frequency-dependent couplings were used. Such dispersive couplingswere implemented as shorted stubs. The design process startswith the generation of a suitable starting point. To this end, anapproximation of SIW as a rectangular waveguide is...
-
Visual measurement system for chosen parameters of current collectors
PublicationA current collector is an element in a traction vehicle, used for movable, contact con-nection between the main circuit of this vehicle and the contact line. Bad technical condi-tion of these important elements in the main circuit of the vehicle result in its incorrect cooperation with contact line. Periodic control of technical condition of current collectors ensures infallible current collection. The pantograph diagnostics consists...
-
Determining the leakage current resistive component by the orthogonal vector method
PublicationThe measurement of the metal – oxide surge arresters (MOSA) leakage current and the analysis of its components is a key diagnostic criterion according to technical standards. During on site MOSA condition assessment, the easy way is based on the measurement only leakage current, without the inconvenient live working measurements of supply voltage. Orthogonal vectors method of determination the resistive leakage current is presented....
-
Errors of a Linear Current Approximation in High-Speed PMSM Drives
PublicationCurrent sampling techniques and predictive algorithms used in the digital control of electric drives rely on a simple mathematical model that assumes linear current changes upon constant supplying voltages. This paper identifies rotor movement as a factor that makes this assumption invalid when the rotor covers an angular distance of a few tens of degrees during the control interval duration. The errors of the linear current approximation...
-
Dimensional Synthesis of Coupled-Resonator Pseudoelliptic Microwave Bandpass Filters with Constant and Dispersive Couplings
PublicationIn this paper, we propose a novel technique for the dimensional synthesis of coupled-resonator pseudoelliptic microwave filters with constant and dispersive couplings. The proposed technique is based on numerical simulations of small structures, involving up to two adjacent resonators, and it accounts for a loading effect from other resonators by replacing them with terminations coupled through appropriately scaled inverters. The...
-
Treatment of malodorous air in biotrickling filters: A review
PublicationOdour nuisance, resulting mainly from the presence of the compounds containing osmophore group and characterized by low olfactory threshold, is associated with danger and may be the cause of negative psychosomatic symptoms. Among different methods of malodorous air treatment, biological methods are of importance, mainly due to reduced operating costs, high purification efficiency of voluminous gas streams characterized by low concentrations...
-
Remote current measurement with FPGA digital processing
PublicationThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
The Influence of Limiters UEL and OEL (The power angle, stator's current and excitation current) ot the possibility of voltage collapse development
PublicationVoltage stability has been a major concern for power system utilities because of event of voltage collapses in the recent past. Sometimes, power system events have shown the need for generators to operate in the overexcited and underexcited region to support stable operation. Modern excitation systems include devices for controlling or limiting machine terminal voltage (overvoltage limiters), volts per hertz ratio (V/Hz limiters),...
-
Yerba Mate - A Long but Current History
PublicationBearing in mind the growing interest in Yerba Mate, a comprehensive study has been prepared containing the most important aspects and possibilities of its use. The introduction of the work contains the species characteristics of Yerba Mate, as well as information about the origin and places of cultivation. The next part focuses on the analysis of the composition, pointing to purine alkaloids, polyphenols, saponins, and minerals...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Removal of cyclohexane and ethanol from air in biotrickling filters inoculated with Candida albicans and Candida subhashii
PublicationThis paper presents investigations on the removal of cyclohexane and ethanol from air in polyurethane- -packed biotrickling filters, inoculated with Candida albicans and Candida subhashii fungal species. Results on process performance together with flow cytometry analyses of the biofilm formed over packing elements are presented and discussed. The results indicate that the presence of ethanol enhances the removal efficiency of cyclohexane...
-
A Novel Coupling Matrix Synthesis Technique for Generalized Chebyshev Filters With Resonant Source–Load Connection
PublicationThis paper reports a novel synthesis method for microwave bandpass filters with resonant source–load connection. In effect, a network realizing N+1 transmission zeros (where N is the number of reflection zeros) is obtained. The method is based on a prototype transversal coupling matrix (N+2, N+2) with source and load connected by a resonant circuit formed by a capacitor in parallel with a frequency-invariant susceptance. To complement...
-
Suppression of Supply Current Harmonics of 18-Pulse Diode Rectifier by Series Active Power Filter with LC Coupling
PublicationThe reported research aims at improving the quality of three-phase rectifier supply currents. An effective method consists of adding properly formed booster voltages to the fundamental supply voltages using a series active filter. In the proposed solution, the booster voltages are generated by three single-phase systems consisting of inverters, LC filters, and single-phase transformers. The application of LC couplings ensures low...
-
Current advances in membrane processing of wines: A comprehensive review
PublicationBackground Membrane-based operations, especially pressure-driven membrane operations, are today well-established procedures for various applications in the wine industry thanks to their intrinsic properties and undoubted advantages over traditional methods. Emerging membrane processes, such as pervaporation, electrodialysis and osmotic distillation, forward osmosis, membrane contactors, offer new and interesting perspectives to...
-
Conducted EMI mitigation in switched mode DC-DC converters by spread spectrum techniques
PublicationW artykule przedstawiono skuteczność technik rozpraszania widma do ograniczenia emisji przewodzonej EMI dla szeregowego przerywacza napięcia. Badania porównawcze zostały wykonane laboratoryjnie za pomocą generatora funkcyjnego, miernika zaburzeń i sieci sztucznej. Analiza otrzymanych wyników wykazała, szczególnie korzystne do 20 dB, ograniczenie charakterystyki napięcia emisji przewodzonej dla losowej modulacji częstotliuwości...
-
THE USE OF MORPHOLOGICAL FILTERS AND GRANULOMETRIC METHOD TO ANALYZE THE MOVEMENT OF THE MOLECULES IN THE SEA WATER OF THE SOUTHERN BALTIC SEA
PublicationModern granulometry opens a new way of analysing images by means of morphological filters. In this paper a closer look has been presented on the problem of interpreting information about the features and conditions of marine environment from images taken at the sea coast and shallow water. Using this method allows for example selection of the objects on the image according to the differences in shape. Processes occurring in the...
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublicationAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
Requirements for Residual Current Devices Intended for Electric Vehicle Charging Systems
PublicationThe properties of residual current devices have been presented from the point of view of their ability to detect a specific shape of the residual current waveform. Moreover, the standard requirements relating to residual current protection used in electric vehicle charging installations have been pointed out. The operating characteristics of the IC-CPD and RDC-DD protections, which are intended for charging electric vehicles in...
-
Current Challenges in Targeting Tumor Desmoplasia to Improve the Efficacy of Immunotherapy
Publication -
The effect of earth fault current harmonics on tripping of residual current devices
PublicationSzerokie zastosowanie przekształtników, a w szczególności przemienników częstotliwości sprawia, że wyłączniki różnicowoprądowe znajdują się w obwodach, w których może płynąć odkształcony prąd ziemnozwarciowy. Prąd ziemnozwarciowy w obwodach z przemiennikami częstotliwości zawiera harmoniczne, których rząd głównie zależy od częstotliwości PWM. Odkształcony prąd wpływa na poprawne wyzwalanie wyłączników różnicowoprądowych. W artykule...
-
Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
PublicationThis paper presents the compensation tasks performed by a shunt active power filter, including compensation of harmonic currents, reactive power, and an unbalanced load current. The paper demonstrates novel control of the shunt active power filter in a closed-loop system. The control algorithm was verified by performing simulations and compared the simulated results with those obtained in an open-loop control system. All simulations...
-
Automated Diagnostics of Current Pick-Up Disturbances in Electric Traction Networks
PublicationThe present work defines the basic causes of bow disturbances of current pick-up, sets a task of establishing a system of automated control of bow disturbances at feeder zones of electric traction networks, proposes structural variants of the technical system implementation, describes the algorithm of detection of bow disturbances of current pick-up.
-
Behavior of residual current devices at frequencies up to 50 kHz
PublicationThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
A general approach to continuous time Gm-C filters.
PublicationW pracy zaproponowano ogólną strukturę filtrów Gm-C z odpowiednim opisem macierzowym. W odniesieniu do tej struktury podano formuły analizy wrażliwościowej dla dowolnego filtru Gm-C czasu ciągłego. Analiza oparta na opisie macierzowym była wykorzystana również do porównania właściwości filtrów Gm-Ctrybu napięciowego i prądowego. Zdefiniowano dwie kanoniczne transformacje dla klasy filtrów zmiennych stanu.
-
Tolerance Analysis of Continuous Time Gm-C Filters.
PublicationW pracy opisano metodę analizy tolerancji dla filtrów Gm-C dowolnego typu i rzędu. Opracowano odpowiednie formuły analityczne korzystając z ogólnego modelu filtrów tej klasy oraz zunifikowanego opisu macierzowego. W końcowej części pracy przedstawiono wybrane przykłady zastosowań proponowanej procedury z włączeniem analizy metody najgorszego przypadku dla filtrów Gm-C wysokiego rzędu.
-
General Gm-C filters with finite band transconductors.
PublicationW pracy przedstawiono wyniki badań dotyczących wpływu skończonego pasma przenoszonych częstotliwości elementów transkonduktancyjnych na właściwości filtrów Gm-C czasu ciągłego. Opracowano miary dewiacji charakterystyk częstotliwościowych filtrów Gm-C spowodowanych skończonymi wartościami elementów pojemnościowych i rezystancyjnych na wyjściu transkonduktorów. Proponowana procedura analizy może znaleźć szerokie zastosowanie...
-
Automated design of waveguide filters with frequency-dependent couplings.
PublicationW artykule zaproponowano szybką technikę pozwalającą na automatyczne projektowanie filtrów falowodowych ze sprzężeniami zależnymi od częstotliwości. Procedura optymalizacyjna jest trójetapowa z różnymi funkcjami celu w każdym etapie.
-
Performance optimization of continuous-time OTA-C filters.
PublicationW pracy przedstawiono analityczne podejśćie do optymalizacji właściwości filtrów OTA-C czasu ciągłego. Zaprezentowano efektywne metody analizy zniekształceń nieliniowych i szumów dla dowolnego filtru OTA-C wykorzystując ogólny model oparty na opisie macierzowym. Rezultaty teoretyczne odnoszące się do kaskadowego filtru typu Butterwotha były weryfikowane na drodze porównawczej z wynikami otrzymanymi na poziomie ''Transistor-Level''...
-
Noise performance of continuous-time active-RC filters.
PublicationW pracy przedstawiono metodę analizy właściwości szumowych filtrów aktywnych RC czasu ciągłego. Prezentowana procedura wykorzystuje model integratorowy, z odpowiednim dla tej klasy filtrów opisem macierzowym. Dokładność osiągniętych wyników teoretycznych dla przykładowego filtru potwierdzono rezultatami otrzymanymi przy pomocy symulatora SPICE.
-
Distortion Analysis of Gm-C Filters - Numerical Approach
PublicationW pracy przedstawiono efektywną procedurę symulacji numerycznej zniekształceń nieliniowych dla dowolnych filtrów Gm-C. Zaprezentowano ogólny model filtrów Gm-C zawierających nieliniowe elementy aktywne (transkonduktory). Przeprowadzono analizę modelu, która prowadzi do sformułowania ogólnego nieliniowego układu równań różniczkowych zwyczajnych opisujacych dynamikę napięć węzłowych filtru w dziedzinie czasu. Scałkowanie numeryczne...
-
General Approach to Continuous-Time OTA-C Filters
PublicationW książce zaprezentowano podstawy analizy i projektowania filtrów aktywnych typu OTA-C. Podana została procedura zunifikowanego opisu macierzowego ogólnej struktury układowej filtrów OTA-C czasu ciągłego dla pracy w trybie napięciowym i prądowym. Przyjęty formalizm macierzowy jest dogodny do zastosowania w różnego rodzaju programowych narzędziach komputerowego wspomagania analizy i syntezy filtrów aktywnych tej klasy. Zaproponowana...
-
Generalized Savitzky–Golay filters for identification of nonstationary systems
PublicationThe problem of identification of nonstationary systems using noncausal estimation schemes is consid-ered and a new class of identification algorithms, combining the basis functions approach with localestimationtechnique,isdescribed.Unliketheclassicalbasisfunctionestimationschemes,theproposedlocal basis function estimators are not used to obtain interval approximations of the parametertrajectory, but provide a sequence of point...
-
Behavior of residual current devices at earth fault currents with DC component
PublicationLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Method of sacrificial anode dual transistor-driving in stray current field
PublicationIn order to control a magnesium anode in a stray current interference field, a dual transistor driving system has been proposed. It consisted of a combination of PNP and NPN transistors. Dual transistor driven system and direct anode to cathode connection were electrochemically tested in 3% NaCl solution. The dual transistor driven system increased the anode efficiency and reduced hydrogen evolution and the risk of embrittlement....
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Time-current tripping curves of arc fault detection devices
PublicationTripping curves of arc fault detection devices, in accordance with PN-EN 62606 “General requirements for arc fault detection devices” have been presented in the paper. Consequently the most fundamental differences in arc fault detection devices tripping compared to circuit-breakers and residual current devices have been indicated.
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublicationElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
Modular high precision high current source for special applications — Simulation and verification
PublicationThis paper presents selected issues concerning realization of high precision high current source for special applications, where high demands of output parameters of such device are required. A new 80 kW prototype of modular high precision high current source is presented, where output current accuracy reaches 5x10-5. This paper presents also results of operation of the simulation model and of the prototype converter. In order...
-
Comparison of residual current devices tripping characteristics for selected residual current waveforms
PublicationZgodnie z normami międzynarodowymi, w instalacjach o zwiększonym ryzyku porażenia prądem elektrycznym należy stosować wyłączniki różnicowoprądowe wysokoczułe. Dla zapewnienia skutecznej ochrony przeciwporażeniowej zainstalowany wyłącznik różnicowoprądowy powinien prawidłowo wykrywać określony kształt prądu różnicowego. W artykule przedstawiono charakterystyki działania wyłączników różnicowoprądowych przy wybranych przebiegach odkształconego...
-
Softly switched model predictive control for control of integratedwastewater treatment system at medium time scale.
PublicationW przypadku gdy system jest sterowany za pomocą jednej, uniwersalnej strategii sterowania w pełnym zakresie jego obciążeń, powstają poważne trudności w znalezieniu optymalnego sterowania. W celu jak najlepszego dopasowania strategii sterowania do panujący warunków, zdefiniowano trzy stany operacyjne: normalny, zakłóceniowy oraz awaryjny. Dla tych stanów zaprojektowano odpowiednie strategie sterowania. W związku z tym pojawia się...
-
Mobility management solutions for current IP and future networks
PublicationEnormous progress in the design of portable electronic devices allowed them to reach a utility level comparable to desktop computers, while still retaining their mobility advantage. At the same time new multimedia services and applications are available for IP users. Unfortunately, the performance of base IP protocol is not satisfactory in mobile environments, due to lack of handover support and higher layer mobility management...
-
Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor
PublicationDiagnosis of induction motors, conducted remotely by measuring and analyzing the supply current is attractive with the lack of access to the engine. So far there is no solution, based on analysis of current, the credibility of which allow use in industry. Statistics of IM bearing failures of induction motors indicate, that they constitute more than 40% of IM damage, therefore bearing diagnosis is so important. The article provides...
-
Speed sensorless induction motor drive with predictive current controller
PublicationToday, speed sensorless modes of operation are becoming standard solutions in the area of electric drives. This paper presents a speed sensorless control system of an induction motor with a predictive current controller. A closed-loop estimation system with robustness against motor parameter variation is used for the control approach. The proposed algorithm has been implemented using field-programmable gate arrays (FPGAs) and a...
-
Sensorless Control of Induction Machine Supplied by Current Source Inverter
PublicationThe paper describes the voltage control technique of induction machines supplied by a current source inverter. The control system is based on proposed new multi-scalar variables, which are named “r.” The control system contains the output filter capacitor's model. In the sensorless control system the Z type backstepping speed observer was applied. The mathematical dependences are confirmed by simulation and experimental research.
-
Programmable Input Mode Instrumentation Amplifier Using Multiple Output Current Conveyors
PublicationIn this paper a programmable input mode instrumentation amplifier (IA) utilising second generation, multiple output current conveyors and transmission gates is presented. Its main advantage is the ability to choose a voltage or current mode of inputs by setting the voltage of two configuration nodes. The presented IA is prepared as an integrated circuit block to be used alone or as a sub-block in a microcontroller or in a field...
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Determination of Local Corrosion Current from Individual Harmonic Components
PublicationHarmonic analysis has been used in corrosion measurements for several decades. During this period the method has been refined and developed. Nevertheless, the technique has not been applied to properties determination in local scale yet. This paper is focused on local corrosion current measurements based on harmonic analysis. For this purpose, a non-linear nature of electrode processes is used and measured in local scale applying...