Filters
total: 1391
filtered: 781
-
Catalog
Chosen catalog filters
Search results for: BONE-IMPLANT INTERFACE
-
Nanotubular oxide layers and hydroxyapatite coatings on porous titanium alloy Ti13Nb13Zr
PublicationThe surface condition of an implant has a significant impact on response occurring at the implant-biosystem border. The knowledge of physical-chemical and biological processes allows for targeted modification of biomaterials to induce a specified response of a tissue. The present research was aimed at development of technology composing of obtaining the nanotube oxide layers on a porous titanium alloy Ti13Nb13Zr, followed by the...
-
Design of radio communication systems for unmanned transport applications
PublicationIn the paper the principle of OFDMA-based radio communication systems design for unmanned transport applications is presented. The concept of system radio interface is analysed and its basic parameters proposal are considered. In the last part of the paper some air interface characteristics useful for optimization of throughput and system capacity are considered.
-
Smart Healthy Age-Friendly Environments (SHAFE) Bridging Innovation to Health Promotion and Health Service Provision
Publication -
Effect of welding conditions on susceptibility to cold cracking of underwater welded joints
PublicationPrzedstawiono wybrane aspekty spawalności stali przy spawaniu pod wodą metodą lokalnej komory suchej. Zwrócono szczególną uwagę na skłonność do tworzenia peknięć zimnych w SWC. Przy pomocy planowania doświadczeń określono ilościowy wpływ parametrów spawania na naprężenia krytyczne z próby implant.
-
Medially positioned plate in first metatarsophalangeal joint arthrodesis
PublicationObjective The purpose of this study was to biomechanically compare the stability of first metatarsophalangeal (MTP1) joint arthrodesis with dorsally and medially positioned plates. Methods A physical model of the MTP1 joint consists of printed synthetic bones, a titanium locking plate and screws. In the experiments, samples with dorsally and medially positioned plates were subjected to loading of ground load character in a universal...
-
BJS-03 DO WE NEED FIXATION OF THE MESH IN LAPAROENDOSCOPIC TECHNIQUES FOR M3 INGUINAL DEFECTS? AN EXPERIMENTAL STUDY
PublicationThe authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. The results showed that mesh fixation is not the only alternative to preventing recurrence in complex defects and that the type of implant seems to be a key factor from the point of view of mechanics and biophysics.
-
Evaluation of the Cathodic Electrodeposition Effectiveness of the Hydroxyapatite Layer Used in Surface Modification of Ti6Al4V-Based Biomaterials
PublicationThe important issue associated with the design and the fabrication of the titanium and titanium alloy implants is the increase of their biointegration with bone tissue. In the presented paper, the research results concerning the conditions used in the cathodic deposition of hydroxyapatite on the surface Ti6Al4V substrates primarily modified by the production of TiO2 nanoporous coatings, TiO2 nanofibers, and titanate coatings, are...
-
The influence of biological environment on the appearance of silver-coated implants
PublicationDespite antibiotics preventive treatment before and after implantation, risk of infection is real. The infections at the implant surface developein a few months after applying them into the body. To prevent the development of bacteria and to reduce the risk of infection, implants coated with silver layer come into use. The paper presents the research results in biological environment on vein and orthopaedicimplants covered with...
-
Self-Organized Nanotubular Oxide Layers on Ti and Ti Alloys
PublicationTo improve bioactivity of titanium and titanium, the implant surface modification by formation of self-organized TiO2 nanotube arrays with electrochemical techniques is presented. The influence of electrolyte composition and deposition parameters during anodization is characterized. The enhancement of phosphates deposition by titanium nanotubular structure is discussed. The calcium phosphate ceramics is shown to be uniformly deposited...
-
M2M communications system proposal for maritime applications
PublicationThis article describes the proposal to use the M2M communication to enhance the safety of people, ships and other marine infrastructure, in broadly defined marine systems. In addition, there are numerous examples of planned solutions to be implemented in the near future as well as new services. The proposal for M2M communication system architecture is described below. In addition, the use of the STRUGA system radio interface as...
-
Discussion of “Stress-Displacement Response of Sand–Geosynthetic Interfaces under Different Volume Change Boundary Conditions” by Aliyeh Afzali-Nejad, Ali Lashkari, and Alejandro Martinez
PublicationThe influence of normal stiffness of interface on the interpretation of shear box tests
-
Nanotubular Oxide Layer Formed on Helix Surfaces of Dental Screw Implants
PublicationSurface modification is used to extend the life of implants. To increase the corrosion resistance and improve the biocompatibility of metal implant materials, oxidation of the Ti-13Nb- 13Zr titanium alloy was used. The samples used for the research had the shape of a helix with a metric thread, with their geometry imitating a dental implant. The oxide layer was produced by a standard electrochemical method in an environment of...
-
The Setting Time of Polyether Impression Materials after Contact with Conventional and Experimental Gingival Margin Displacement Agents
Publication -
Analiza możliwości zastosowania planowania badań do określania skłonności do tworzenia pęknięć zimnych.
PublicationW pracy przedstawiono rozważania na temat możliwości zastosowania teorii planowania badań do określania skłonności do tworzenia pęknięć na zimno badanej metodą implant. Opisano wady i zalety wybranych planów badań z uwzględnieniem kryteriów realizowalności, informatywności i efektywności. Szczególną uwagę zwrócono na trudności związane z zastosowaniem planowania badań do zagadnień spawalniczych.
-
A method of measuring RLC components for microcontroller systems
PublicationA new method of measuring RLC components for microcontroller systems dedicated to compact smart impedance sensors based on a direct sensor-microcontroller interface is presented. In the method this direct interface composed of a reference resistor connected in series with the tested sensor impedance is stimulated by a square wave generated by the microcontroller, and then its voltage response is sampled by an internal ADC of the...
-
In Vitro Biological Characterization of Silver-Doped Anodic Oxide Coating on Titanium
PublicationDespite the high biocompatibility and clinical effectiveness of Ti-based implants, surface functionalization (with complex osteointegrative/antibacterial strategies) is still required. To enhance the dental implant surface and to provide additional osteoinductive and antibacterial properties, plasma electrolytic oxidation of a pure Ti was performed using a nitrilotriacetic acid (NTA)-based Ag nanoparticles (AgNP)-loaded calcium–phosphate...
-
Skłonność do tworzenia pęknięć zimnych złączy spawanych ze stali o podwyższonej wytrzymałości wykonanych pod wodą.
PublicationW pracy przedstawiono zagadnienie spawalności stali 18G2A w odniesieniu do spawania pod wodą metodą lokalnej komory suchej. Zaprezentowano wyniki badań skłonności do tworzenia pęknięć zimnych metodą implant. Ustalono, że podczas spawania pod wodą stal 18G2A cechuje się zwiększoną wrażliwością na tworzenie się pęknięć zimnych w porównaniu ze spawaniem w środowisku powietrznym.
-
Effect of lag screw on stability of first metatarsophalangeal joint arthrodesis with medial plate
PublicationBackground: First metatarsophalangeal joint (MTP-1) arthrodesis is a commonly performed procedure in the treatment of disorders of the great toe. Since the incidence of revision after MTP-1 joint arthrodesis is not insignificant, a medial approach with a medially positioned locking plate has been proposed as a new technique. The aim of the study was to investigate the effect of the application of a lag screw on the stability and...
-
FEM approach to modeling of an irregular trabecular structure
PublicationThe aim of the study is elaboration of a method for creating irregular scaffolds that can be used to model the behaviour of trabecular bone placed in the proximal epiphysis of the femur. The scope of the study encompasses creating six numerical models of irregular scaffolds (two solid irregular scaffolds, two shell irregular scaffolds and two shell irregular scaffolds with fortification) and performing numerical analysis of the...
-
Fabrication of Composite Polyurethane/Hydroxyapatite Scaffolds Using Solvent-Casting Salt Leaching Technique
PublicationScaffolds are porous three-dimensional structures which are used to fill bone losses and make them possible to cells to grow. Many different structural and biological properties are required from them: porosity, mechanical strength and biocompability. The present research is aimed at development of composite polyurethane/hydroxyapatite scaffolds by using the solvent-casting salt leaching method. The SEM examinations were applied...
-
A Special Section on Intelligent User Interfaces in Healthcare (IUIH)
PublicationA concept of interface has evolved from the first appearance in the form of a command line interface to the established use of direct manipulation or WIMP (windows, icons, menus and pointing) interfaces in nearly all applications. Intelligent user interfaces (IUI) form a subfield of Human-Computer Interaction research. Optimal human-computer interactions are defined as ones where users are able to perform complex tasks more quickly...
-
Urban Waterfront Regeneration: Origins of the Issue
PublicationThis paper deals with the origins of the issue of urban waterfront regeneration. The process of city-water interface was described with references to the three generations of port structures.
-
Test Execution Logging and Visualization Techniques
PublicationTraditionally, log traces of test cases ex ecution are stored in textual format and their analysis is done in a post- execution phase. Our approach bases on the concept of gr aphical presentation of te st execution which enables better analysis of log traces and also gives the opportunity to consider them on-line. In particular, we discuss the graphical symbols we chose, we pres ent the logging interface we defined a nd describe...
-
Modelowanie i badania doświadczalne implantów stosowanych w operacjach laparoskopowych
PublicationW pracy przedstawiono problemy modelowania implantów wszczepianych do powięzi w czasie operacji przepuklin brzusznych. Zastosowano metodę elementów skończonych w implementacj komputerowej systemu MSC.Marc.Wyniki symulacji komputerowej porównano z wynikami badań doświadczalnych implantu połączonego z powięzia zszywkami, które przeprowadzono w specjalnej, szczelnej komorze. Badany układ implant-powięź poddany był działaniu impulsowego...
-
Nonlinear dynamic analysis of the pure “buckling” mechanism during blow-out trauma of the human orbit
PublicationConsidering the interplay between orbital bones and intraorbital soft tissues, commonly accepted patterns of the blow-out type of trauma within the human orbit require more thorough investigation to assess the minimal health-threatening impact value. Two different three-dimensional finite element method (FEM) models of the human orbital region were developed to simulate the pure “buckling” mechanism of orbital wall fracture in...
-
Light intensity analysis of photovoltaic parameters for perovskite solar cells
PublicationThe number of publications on perovskite solar cells (PSC) continues to grow exponentially. Although the efficiency of PSC is exceeded 25.5%, not every research laboratory can reproduce this result or even pass the border of 20%. Unfortunately, it is not always clear which dominating mechanism is responsible for the performance drop. Here, we develop a simple method of light intensity analysis of JV parameters allowing the understanding...
-
Polynomial Chaos Expansion in Bio-and Structural Mechanics
PublicationThis monograph presents a probabilistic approach to modelling the mechanics of materials and structures where the modelled performance is influenced by uncertainty in the input parameters. The work is interdisciplinary and the methods described are applied to medical and civil engineering problems. The motivation for this work was the necessity of mechanics-based approaches in the modelling and simulation of implants used in the...
-
Mechanics of mesh implanted into abdominal wall under repetitive load. Experimental and numerical study
PublicationThere are a number of papers discussing medical and mechanical aspects of ventral hernia management. Despite intensive work on the problem understanding, recurrences of the sickness still happen too often. For that reason new aspects of the problem must be considered. In this paper, a change in the abdominal implant’s stiffness is discussed, which is caused by cyclic loading. Such loading influence abdominal implant e.g. while...
-
Polynomial Chaos Expansion in Bio- and Structural Mechanics
PublicationThis thesis presents a probabilistic approach to modelling the mechanics of materials and structures where the modelled performance is influenced by uncertainty in the input parameters. The work is interdisciplinary and the methods described are applied to medical and civil engineering problems. The motivation for this work was the necessity of mechanics-based approaches in the modelling and simulation of implants used in the repair...
-
Beam on elastic foundation with anticlastic curvature: Application to analysis of mode I fracture tests
PublicationA first order correction is proposed taking into account both interface elasticity and transverse anticlastic curvature of flexible substrate(s) in the DCB (and related tests). Adherends are represented by Kirchhoff-Love plates, and the interface by Winkler-type elastic foundation. Two functions are introduced, representing evolution of beam deflection along the sample midline and anticlastic curvature along the plate. A method...
-
Modifiers for Medical Grade Polymeric Systems used in FDM 3D Printing - Short Review
PublicationFDM 3D printing could find an application in the wide range of biomedical applications. Unfortunately, the quantity of polymeric biomaterials suitable to processing into filaments is limited. The most frequently used biomaterials for medical constructs such as bone grafts, soft tissue scaffolds or another DDS include PCL, PLA, PVA, HPC, EVA copolymer, EC and TPUs. Various modifiers such as TCP, HA, TEC, MMC could be applicated...
-
Wave transmission across surface interfaces in lattice structures
PublicationWithin the lattice dynamics formulation, we present an exact solution for anti-plane surface waves in a square lattice strip with a surface row of material particles of two types separated by a linear interface. The considered problem is a discrete analog of an elastic half-space with surface stresses modelled through the simplified Gurtin–Murdoch model, where we have an interfacial line separating areas with different surface...
-
pH-dependent composite coatings for controlled drug delivery system - Review
PublicationNowadays in case of long-term implants, the most common postoperative complications are bacterial infections, which in consequence may provoke loos- ening of the implants in the primary phase of stabilization. Bacterial infections are currently the most frequent cause of revision surgery of the implants such as hip joint endoprosthesis, knee joint endoprosthesis and dental implants. In order to provide the local and long-term antibacterial...
-
Is mesh fixation necessary in laparoendoscopic techniques for M3 inguinal defects? An experimental study.
Publicationrepairs, in case of large direct hernias (M3) mesh fixation is recommended to reduce recurrence risk. Despite lack of highquality evidence, the recommendation was upgraded to strong by expert panel. The authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. Method The authors conducted...
-
Reactive deposition of TiNx layers in a DC-magnetron discharge
PublicationTiNx layers have been deposited in 'balanced mode' and 'unbalanced mode' of a reactive DC-magnetron plasma (carrier gas argon, reactive gas nitrogen) under different conditions. Discharge power and reactive gas flow have been varied. The layers have been examined by X-ray photoelectron spectroscopy (XPS), X-ray reflectometry (XR), and spectroscopic ellipsometry (SE). The results of the layer analyses were combined with plasma investigations...
-
Bisquare robust polynomial fitting method for dimple distortion minimization in surface quality analysis
Publication -
Proposal of frequency‐based decomposition approach for minimization of errors in surface texture parameter calculation
Publication -
Application of multisine nanoscale impedance microscopy to heterogeneous alloy surface investigations
PublicationIn the recent years atomic force microscopy is recognized as valuable tool for investigation of surficial features of construction materials. It concerns, among other things, studies of changes caused by such phenomena as galvanic corrosion, passivation associated with the growth of oxide layers, or sensitization of austenitic steels with the formation of carbide phases. In addition, atomic forcemicroscopy allows easy coupling...
-
Analysis and comparision of safety of children and adult passanger in car based on crash tests results
PublicationThis paper presents analysis and comparision of safety of children and adult passanger in car based on crash tests results. The car crash test with four dummies, including two car seats allowed a direct comparison of the security under the same conditions of children and passengers directly to the car seat. Analysis of acceleration and video from the test allows to understand the phenomena during the collision, the air bags influence,...
-
3D Computer Model of the Hip Joint Cartilage
PublicationThis paper presents 3D computer model of the hip joint cartilage in the ANSYS program. Model is made on the basis of anatomy and collected data on the material constants of bone and cartilage components. Analysis and comparison of biochemical model, viscoelastic and molecular mixed - aggregation serves to facilitate the creation of the next model of reality, which could be used in the design of joint prostheses. The correctness...
-
Channel State Estimation in LTE-Based Heterogenous Networks Using Deep Learning
PublicationFollowing the continuous development of the information technology, the concept of dense urban networks has evolved as well. The powerful tools, like machine learning, break new ground in smart network and interface design. In this paper the concept of using deep learning for estimating the radio channel parameters of the LTE (Long Term Evolution) radio interface is presented. It was proved that the deep learning approach provides...
-
Incorporating installation effects into the probability analysis of controlled modulus columns
PublicationThis technical report presents the probabilistic analysis which integrates the Monte Carlo simulation (MCS) with random field theory to model the load–displacement behavior of Controlled Modulus Columns (CMCs) in overconsolidated Poznań clay. Presented study focuses on the practical aspects of statistical analysis of geotechnical data, numerical model development, and results evaluation. Variability and spatial distribution of...
-
Using deep learning to increase accuracy of gaze controlled prosthetic arm
PublicationThis paper presents how neural networks can be utilized to improve the accuracy of reach and grab functionality of hybrid prosthetic arm with eye tracing interface. The LSTM based Autoencoder was introduced to overcome the problem of lack of accuracy of the gaze tracking modality in this hybrid interface. The gaze based interaction strongly depends on the eye tracking hardware. In this paper it was presented how the overall the...
-
Cough influence on fascia-mesh system built for a hernia repair - an experimental research
PublicationAn experimental approach to identify stronger and weaker fixation schemes in laparoscopic ventral hernia repair is presented in the paper. Two types of implants, whose mechanical properties are significantly different and five kinds of connectors are considered. Physical models of operated hernia have been built using those materials and porcine abdominal tissue. The models have been subjected to dynamic impulse load, similar to...
-
Exploring the interfacial effects at the ETL/perovskite boundary in the semitransparent perovskite solar cells
PublicationThe recent focus has been made on the perovskite solar cells (PSCs) with an inverted configuration, where substantial improvements have been already achieved. However, the p–i–n structure needs a buffer layer for most of the configurations to modify the work-function of a deposited electrode. Additionally and very importantly, such a layer can also serve as a protective film that improves a stability of solar cells. Here, we study...
-
Układ informatyczny systemu diagnostycznego ciągników kołowych
PublicationPodstawowym elementem systemu diagnostycznego jest komputer pokładowy Fujitsu FUTRO S100 z chłodzeniem pasywnym w wykonaniu odpornym na drgania i wstrząsy, z pamięcią Compact Flesh 16Gb. Do komputera dołączony jest monitor dotykowy NVOX LCD 10" VGA/FVAT. Oprogramowanie komputera obejmuje system operacyjny Windows XP-2000, driver konwertera USB/DeviceNet oraz opracowany program diagnostyczny. Komputer połączony jest łączem USB z...
-
Electrophoretic Deposition and Characterization of Chitosan/Eudragit E 100 Coatings on Titanium Substrate
PublicationCurrently, a significant problem is the production of coatings for titanium implants, which will be characterized by mechanical properties comparable to those of a human bone, high corrosion resistance, and low degradation rate in the body fluids. This paper aims to describe the properties of novel chitosan/Eudragit E 100 (chit/EE100) coatings deposited on titanium grade 2 substrate by the electrophoretic technique (EPD). The deposition...
-
The influence of a change in the meniscus cross-sectional shape on the medio-lateral translation of the knee joint and meniscal extrusion
PublicationObjective The purpose of this study was to evaluate the influence of a change in the meniscus cross sectional shape on its position and on the biomechanics of a knee joint. Methods One main finite element model of a left knee joint was created on the basis of MRI images. The model consisted of bones, articular cartilages, menisci and ligaments. Eight variants of this model with an increased or decreased meniscus height were then...
-
Soft Tissue Retraction Maneuver in Cone Beam Computed Tomography Prior to Crown-Lengthening Procedure—A Technical Note
PublicationBackground: An accurate determination of the biological width and the relationship of the cemento-enamel junction with the border of the alveolar bone is crucial during a clinical crown-lengthening (CCL) procedure. The aim of this study was to present a technical note about the retraction techniques in cone beam computed tomography (CBCT) prior to CCL, highlighting the significant enhancement in procedural accuracy and predictability...
-
Calculation Program Supporting Switched Capacitor DC-DC Charge Pump Design (CP Design Calculator) - PartII: User's Guide
PublicationPrzewodnik użytkownika programu wspomagającego projektowanie pomp ładunkowych z przełączanymi pojemnościami. Praca jest podzielona na 3 rozdziały (INTRODUCTI ON, GRAPHICAL USER INTERFACE (GUI), PROGRAM NOTIFICATIONS) i podziękowania.