Filters
total: 3522
filtered: 2162
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: BODY MASS INDEX
-
Nitrogen transformations and mass balances in anaerobic/anoxic/aerobic batch experiments with full-scale biomasses from BNR activated sludge systems.
PublicationThe aim of this study was to investigate nitrogen mass balances occurring inside full-scale BNR activated sludge systems, with special attention to colloidal and dissolved organic nitrogen (CON and DON) transformations. For this purpose, laboratory experiments were carried out using process biomass from two large BNR plants in northern Poland. Two parallel batch reactors were operated in a 3-phase (anaerobic/anoxic/aerobic) cycle....
-
Nitrogen transformations and mass balances in anaerobic/anoxic/aerobic batch experiments with full-scale biomasses from BNR activated sludge systems.
PublicationThe aim of this study was to investigate nitrogen mass balances occurring inside full-scale BNR activated sludge systems, with special attention to colloidal and dissolved organic nitrogen (CON and DON) transformations. For this purpose, laboratory experiments were carried out using process biomass from two large BNR plants in northern Poland. Two parallel batch reactors were operated in a 3-phase (anaerobic/anoxic/aerobic) cycle....
-
Comprehensive two dimensional gas chromatography coupled with mass spectrometry as tool for characterization of the main pollutants present in atmospheric air in Gdansk
PublicationNowadays, the technique that is commonly used to identify and quantify the chemical compounds in gas sample is gas chromatography. The separation resolution in gas chromatography can be improved by applying the modulation technique. In this paper present is the most important information regarding the pollutants present in atmospheric air. The areas in which the tests were carried out are one of the largest industrial zones in...
-
Surface characteristics of glass fibres covered with an aluminum layer after a chemical modification process using secondary ion mass spectrometry (SIMS) and atomic force microscopy (AFM)
PublicationPrzedstawiono wyniki z badań powierzchni modyfikowanych włókien szklanych (przed i po procesie chemicznej modyfikacji ich powierzchni), które są kandydatem na przyszły oryginalny bezmatrycowy materiał odniesienia lotnych analitów etenu (C2H4) metodami spektrometrii mas jonów wtórnych oraz mikroskopii sił atomowych. Badania miały na celu obserwację zmian oraz procesów, jakie zaszły na powierzchni włókien szklanych pokrytych...
-
Quantification of key red blood cell folates from subjects with defined MTHFR 677C>T genotypes using stable isotope dilution liquid chromatography/mass spectrometry
Publication -
On-line assessment of oil quality during deep frying using an electronic nose and proton transfer reaction mass spectrometry
PublicationWe describe a novel method for the quality assessment of oil utilized for deep frying. The method is based on the analysis of frying fumes using a custom electronic nose. The quality score could be obtained after less than 3 min of analysis and without interrupting the frying process or sampling the oil directly. The obtained results were correlated with the peroxide value using a multivariate linear regression model. The most...
-
Boron-doped carbon nanowalls for fast and direct detection of cytochrome C and ricin by matrix-free laser desorption/ionization mass spectrometry
PublicationDetecting proteins via surface assisted laser desorption/ionization mass spectrometry (SALDI-MS) method is still highly challenging, and only few examples of nanomaterials have been demonstrated to perform such detection so far. In this study, carbon nanowalls (CNWs), vertically aligned graphene sheet-based materials, presenting specific morphology, dimensions, and boron doping levels have shown improved performances for both qualitative...
-
Development of a liquid chromatography–tandem mass spectrometryprocedure for determination of endocrine disrupting compounds infish from Mediterranean rivers
PublicationA new, sensitive and rapid method based on QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe)approach followed by ultra high performance liquid chromatography coupled with tandem mass spec-trometry (UHPLC–MS/MS) was developed for the determination of nineteen endocrine disruptors (EDCs)and related compounds belonging to different classes in various fish species. Matrix effect on the analyti-cal performance was evaluated,...
-
Post-Chromatographic Derivatization Coupled with Mass Spectrometry as a Method of Profiling and Identification of Antioxidants; Ligustrum vulgare Phytocomplex as an Example
PublicationHigh-performance liquid chromatography (HPLC) and high-performance thin-layer chromatography (HPTLC) coupled with radical scavenging assays, such as 2,2-diphenyl-1-picrylhydrazyl (DPPH) and 2,2′-azinobis-(3-ethylbenzothiazoline-6-sulfonic acid (ABTS) can be both used for the detection of the antioxidants in plant extracts. In this study, the ethanolic (70% v/v) extracts from different morphological parts of Ligustrum vulgare collected...
-
Application potential of dummy molecularly imprinted polymers as solidphase extraction sorbents for determination of low-mass polybrominated diphenyl ethers in soil and sediment samples
PublicationDespite the introduction of restrictive regulations in the USA and the European Union, polybrominated diphenyl ethers (PBDEs) are still found in various types of environmental and biological samples at significant concentration levels. The presence of these persistent organic pollutants in the environment raises important issues because of their negative impact on immunological and neurological systems, and on the hormonal balances...
-
Comparison of different techniques for extracting Polychlorinated Biphenyls from bottom sediment samples using Isotope Dilution Mass Spectrometry
PublicationIn this work, problems that may occur during determination of trace levels of polychlorinated biphenyls in sediment samples are described. The main error sources are connected with extraction of analytes prior to final determination. During model studies, polychlorinated biphenyls have been extracted from sediment reference material (METRANAL 2) with the use of different solvents (dichloromethane, hexane, and toluene); the process...
-
Determination of antifreeze substances in the airport runoff waters by solid-phase microextraction and gas chromatography–mass spectrometry method
PublicationA new method has been developed for the determination of antifreeze agents such as ethylene glycol (EG), propylene glycol (PG), and diethylene glycol (DEG) in the samples of airport runoff water. The method is based on headspace solid–phase microextraction (HS–SPME) of target analytes, which is coupled with gas chromatography–mass spectrometry (GC–MS). Until now, there was a lack of appropriate methodology for collecting reliable...
-
Enhance Color Rendering Index via Full Spectrum Employing the Important Key of Cyan Phosphor
Publication -
Brassica Napus Florescence Modeling Based on Modified Vegetation Index Using Sentinel-2 Imagery
Publication -
Augmentation index, pulse pressure amplification and superoxide anion production in patients with coronary artery disease
Publication -
Modification of the structural model of manipulator's carrying system for a use of modal control at energy performance index.
PublicationW pracy rozważa się drgania niestacjonarnego układu nośnego manipulatora IRb-6 modelowanego dyskretnie metodą sztywnych elementów skończonych. Z uwagi na gwałtowne ruchy (start, zatrzymanie) poszczególnych członów manipulatora, jest to problem o dużym znaczeniu praktycznym. Jednym ze sposobów nadzorowania tych drgań jest wykorzystanie sterowania modalnego przy energetycznym wskaźniku jakości. Uwzględnia on zmianę w czasie względem...
-
Application of the chromatographic retention index system for theestimation of the calibration constants of permeation passivesamplers with polydimethylsiloxane membranes
PublicationW pracy przedstawiono wyniki badań z zastosowaniem pasywnych dozymetrów typu permeacyjnego, wyposażonych w membrany wykonane z PDMS. Badania dotyczyły oszacowania wartości stałych kalibracyjnych dozymetrów przy wykorzystaniu systemu indeksów retencji, wyznaczanych chromatograficznie, w warunkach liniowego narostu temperatury pracy kolumny (LTPRI). Znaleziono korelację pomiędzy wartościami stałych kalibracyjnych próbników typu pasywnego,...
-
A frequency-domain surveillance of the robot's structural vibration with a use of modal control at energy performance index
PublicationRozważano drgania niestacjonarnego układu nośnego robota IRb-6. W celu nadzorowania drgań zastosowano algorytm sterowania modalnego przy energetycznym wskaźniku jakości w dziedzinie częstotliwości. Podejście takie umożliwia wykorzystanie elementów projektowania mechatronicznego do nadzorowania drgań, którego celem jest minimalizacja amplitudy drgań końcówek manipulacyjnych, a w konsekwencji - poprawa dokładności i powtarzalności...
-
Mechatronics in the design of three wheeled mobile platform controlled by surveillance system at energy performance index
PublicationPraca jest poświęcona projektowaniu mechatronicznemu trójkołowej platformy mobilnej, sterowanej systemem nadzorowania bazującym na energetycznym wskaźniku jakości. Zdefiniowany zakres badań i silna nieliniowość obiektu wymagały niezawodnego systemu sterowania. Warunki deterministyczne i zastosowany algorytm wpłynęły na wybór metody opracowania systemu. Przedstawione techniki projektowania mechatronicznego i przeprowadzone warianty...
-
Brain/blood distribution described by a combination of partition coefficient and molecular mass
Publication -
Effects of a rotating magnetic field on gas-liquid mass transfer coefficient
Publication -
The simultaneous determination of hydrophobicity and dissociation constant by liquid chromatography–mass spectrometry
Publication -
Observation of a new boson at a mass of 125 GeV with the CMS experiment at the LHC
Publication -
Expansion of the self of activists and nonactivists involved in mass gatherings for collective action
Publication -
Improving peak detection by Gaussian mixture modeling of mass spectral signal
Publication -
Experimental an numerical investigation of wave propagation in composite beam with an additional mass
PublicationW pracy przedstawiono wyniki badań eksperymentalnych i symulacji numerycznych ilustrujace wpływ dodatkowej masy na propagacje fali Lamba w belce kompozytowej.
-
A parametric method for preliminary determining of mass characteristics of inland navigation ships
PublicationPrzedstawiono metodę którą opracowano, wykorzystując algorytmy realizujące zalecenia zawarte w Przepisach Klasyfikacji i Budowy Statków Śródlądowych PRS-u, oraz zastosowano uproszczoną metodę wyznaczania mas usztywnień poszycia kadłuba. Metoda wymiarowania oparta na tym algorytmie dotyczy klasycznych statków służących do przewozu drobnicy, ładunków masowych i płynnych - określających zakres stosowania metody. Metoda nie obejmuje...
-
The control of the mass of an aggregates deliveries and its impact on the effectiveness of earthworks execution
Publication -
Analysis of the effect of mass events on car traffic in the city in the daily interval
Publication -
Proportional-derivative and Model-based Controllers for Control of a Variable Mass Manipulator
PublicationW artykule prezentowano wyniki analiza numeryczna dynamiki manipulatora o zmiennej masie. W skład manipulatora wchodzą jedynie członu i przeguby obrotowe. Ładowność chwytaka jest traktowana jako jedyny element o zmiennej masie. Podobnie jak w przypadku innych manipulatorów wyposażonych w przeguby obrotowe, parametry jego dynamika zależą od aktualnego ustawienia. Gdy przemieszczenia obejmują większy zakres roboczy, w równaniach...
-
Nitrogen mass balance and mathematical model of a Structured- Bed Reactor (SBRRIA)
PublicationAn up-flow structured-bed reactor subjected to recirculation and intermittent aeration (SBRRIA) was operated under varying influent conditions. The influent COD/N ratio was adjusted by maintaining a stable organic loading rate (average of 1.07 kgCOD m-3 d-1) and changing the nitrogen loading rate from 0.1 to 0.4 kg N m-3. Therefore, three different COD/N ratios were tested: 9.7±1 (Scenario 1); 7.6±1 (Scenario 2) and 2.9±1 (Scenario...
-
PROTOCOL FOR IN VITRO MASS PRODUCTION OF NEPHROLEPIS EXALTATA SCHOTT (BOSTON FERN)
Publication -
Singlet oxygen in the removal of organic pollutants: An updated review on the degradation pathways based on mass spectrometry and DFT calculations
PublicationThe degradation of pollutants by a non-radical pathway involving singlet oxygen (1O2) is highly relevant in advanced oxidation processes. Photosensitizers, modified photocatalysts, and activated persulfates can generate highly selective 1O2 in the medium. The selective reaction of 1O2 with organic pollutants results in the evolution of different intermediate products. While these products can be identified using mass spectrometry...
-
Monolithic capsule phase microextraction prior to gas chromatography-mass spectrometry for the determination of organochlorine pesticides in environmental water samples
PublicationIn this study, a capsule phase microextraction (CPME) protocol followed by gas chromatography-mass spectrometry is proposed for the accurate and sensitive monitoring of organochlorine pesticides (OCPs) in environmental water samples. Different monolithic sol–gel encapsulated sorbents were compared and monolithic sol–gel poly(ethylene glycol)-based sorbent incorporated into porous microextraction capsules resulted in the highest...
-
The impact of resistance exercise range of motion on the magnitude of upper-body post-activation performance enhancement
Publication -
Efficacy of the Whole-Body Cryotherapy as Add-on Therapy to Pharmacological Treatment of Depression—A Randomized Controlled Trial
Publication -
Arterial stiffness, body fat compartments, central hemodynamics, renal function and left atrial size
Publication -
Effect of diet on the capacity to remove mercury from the body of a penguin (Spheniscus demersus) living in the ZOO
Publication -
Ochratoxin A, deoxynivalenol, T-2 and HT-2 toxins – occurrence in food and their effect on the human body
Publication -
THE EFFECT OF THE FRICTION OF THE REFUSE INSIDE THE REFUSE COLLECTION VEHICLE BODY ON THE WORKING PARAMETERS OF THE COMPACTION MECHANISM
PublicationMechanizm prasujący pojazdu do usuwania odpadów z pojemników (w skrócie PUOP) spełnia dwie funkcje. W pierwszym etapie zagęszcza zebrane z pojemników odpady, a następnie przemieszcza je w głąb skrzyni zbiorczej. Znajo-mość właściwości mechanicznych odpadów znajdujących się wewnątrz skrzyni może w znaczący sposób wpłynąć na poprawę wydajności pojazdu. Celem ba-dań było zwiększenie wydajności PUOP poprzez opracowanie w oparciu...
-
Multianalyte Calibration Methods for Potentiometric Integrated Sensors System for Determination of Ions Concentration in a Body Fluids
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in a small sample volume. One of the key problems related to the preparation of integrated sensors systems (ISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim of the research...
-
BADANIA I ANALIZA DEPOLARYZACJI FAL RADIOWYCH W SIECIACH WBAN TYPU OFF-BODY
PublicationTechniki telekomunikacyjne stanowią niezwykle istotną część naszego życia. Ich dynamiczny rozwój w ostatnich latach wpłynął na sposób komunikacji pomiędzy ludźmi, a także pomiędzy ludźmi a maszynami. Komunikacja bezprzewodowa przeżywa rozkwit w erze urządzeń mobilnych oraz rozmaitych sensorów.
-
The Mechanism of a Retro-Diels–Alder Fragmentation of Luteolin: Theoretical Studies Supported by Electrospray Ionization Tandem Mass Spectrometry Results
PublicationThe mechanisms of retro-Diels–Alder fragmentation of luteolin are studied theoretically using the Density Functional Theory method (B3LYP hybrid functional) together with the 6-311++G(d,p) basis set and supported by electrospray ionization tandem mass spectrometry (ESI-MS) results. The reaction paths leading to the formation of 1,3A and 1,3B fragment ions observed as the main spectral features in the ESI-MS spectrum are described...
-
All-fiber tunable devices based on high-index photonic crystal fibers filled with liquid crystals
Publication -
Laboratory Examination of Frost-heaving Properties of Road Unbound Mixtures Based on Fines Content and Plasticity Index
Publication -
Gradient-Index (GRIN) Matrices Based On Mosaic Assembling Technology (MAT) For Multichannel Fiberoptic Environmental Sensors
Publication -
Application of the chromatographic retention index system for the estimation of the calibration constants of permeation passive samplers with polydimethylsiloxane membranes
PublicationThe paper presents the results of research on the calibration of permeation passive samplers equipped with polydimethylsiloxane (PDMS) membranes using the physico-chemical properties of the analytes. Strong correlations were found between the calibration constants of the samplers and the linear temperature-programmed retention indices of the analytes determined on columns coated with pure PDMS (r2 = 0.914). These correlations...
-
Labview in mechatronic design of control system for three wheeled mobile platform at time changeable performance index
PublicationPraca przedstawia metodykę projektowania mechatronicznego w środowisku Labview systemu sterowania trójkołową platformą mobilną przy zmiennym w czasie energetycznym wskaźniku jakości, zaproponowanym i rozwiniętym w pracach K. Kalińskiego. Autorzy przedstawili ogólną koncepcję stanowiska badawczego oraz badali rozmieszczenie elementów układu sterowania. Ponadto, artykuł zawiera wyniki testów i symulacji zrealizowanych w trakcie programu...
-
Online Volatile Compound Emissions Analysis Using a Microchamber/Thermal Extractor Coupled to Proton Transfer Reaction-Mass Spectrometry
PublicationIndoor air is a complex and dynamic mixture comprising manifold volatile organic compounds (VOCs) that may cause physiological and/or psychological discomfort, depending on the nature of exposure. This technical note presents a novel approach to analyze VOC emissions by coupling a microchamber/thermal extractor (μ-CTE) system to a proton transfer reaction-mass spectrometer (PTR-MS). This configuration provides an alternative to...
-
The preparation and evaluation of core-shell magnetic dummy-template molecularly imprinted polymers for preliminary recognition of the low-mass polybrominated diphenyl ethers from aqueous solutions
PublicationThe design, preparation process, binding abilities, morphological characteristic and prospective field of application of dummy-template magnetic molecularly imprinted polymer (DMMIP) for preliminary recognition of the selected low-mass polybrominated diphenyl ethers (PBDE-47 and PBDE-99) from aquatic environment were investigated. The surface of iron oxide (Fe3O4) nanopowder (50-100 nm particles size) was modified with tetraethoxysilane...