Filters
total: 1178
filtered: 924
Search results for: FAULT LOOP IMPEDANCE
-
Determination of occurrence of anodic excursion peaks by dynamic electrochemical impedance spectroscopy, atomic force microscopy and cyclic voltammetry
PublicationStruktura oraz skład warstw anodowych na ołowiu najbardziej zależy od; dodatków stopowych, stężenia kwasu siarkowego oraz od zakresu potencjału. Zjawisko powstawania pików "anodic excursion peaks" od zawsze było w centrum uwagi wielu naukowców. W tej pracy zachowanie się powyższego zjawiska (AEP) zostało zbadane metodami dynamicznej elektrochemicznej spektrokopii impedancyjnej, mikroskopu sił atomowych oraz chronowoltamperometrii....
-
Dynamic electrochemical impedance spectroscopy and polarization studies to evaluate the inhibition effect of benzotriazole on copper-manganese-aluminium alloy in artificial seawater
PublicationPrzeprowadzono badania wpływu benzotriazolu (BTA) na korozję nowego typ mosiądzu (CMA) w środowisku syntetycznej wody morskiej przy użyciu dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS), techniki polaryzacji rezystancyjnej i ekstrapolacji krzywych Tafela. Wyniki pomiarowe otrzymane przy użyciu tych metod wskazują spadek szybkości korozji wraz ze wzrostem stężenia BTA. Wskazuje to na inhibicyjne własności BTA w...
-
Atomic force microscopy based approach to local impedance measurements of grain interiors and grain boundaries of sensitized AISI 304 stainless steel
Publication -
Atomic force microscopy based approach to local impedance measurements of grain interiors and grain boundaries of sensitized AISI 304 stanless steel
PublicationPraca prezentuje wyniki badań uzyskane z pomiarów techniką lokalnej spektroskopii impedancyjnej (LIS) wykonanych w trybie kontaktowym mikroskopii sił atomowych (AFM), które zostały przeprowadzone w lokalnych obszarach powierzchni ziarna austenitu i na granicy ziarna austenitu wysokostopowej stali austenitycznej AISI 304 poddanej procesowi uczulania oraz na próbkach odniesienia nie poddanych obróbce cieplnej.Badania LIS-AFM były...
-
Impedance spectroscopy as a diagnostic tool of degradation of Solid Oxide Fuel Cells = Spektroskopia impedancyjna jako narzędzie diagnostyczne degradacji tlenkowych ogniw paliwowych
PublicationTlenkowe ogniwa paliwowe SOFC sa obecnie bliskie komercjalizacji. Wiedza na temat mechanizmów degradacji ogniw paliwowych jest niezbędna do dalszej poprawy ich działania. Spektroskopia impedancyjna jest skutecznym narzędziem diagnostycznym. Pozwala ona na wskazanie który element ogniwa SOFC ulega pogorszeniu oraz pozwala poznać dokładniej naturę procesu degradacji. W tej pracy degradacja ogniwa SOFC została zbadana przy użyciu...
-
Impedance Evaluation of the Effect of Ru[sub 0.3]Ti[sub 0.7]O[sub 2] on Electrochemical Properties of Polymeric Conducting Electrodes Used in Cathodic Protection
Publication -
Corrosion behaviour of low carbon steel in artificial seawater using TP, LP, EIS, Harmonic Analysis (HA) and new method Dynamic Electrochemical Impedance Spectroscopy (DEIS)
PublicationZe względu na istotną rolę technik elektrochemicznych w badaniach procesów korozyjnych są one szeroko stosowane w monitorowaniu korozji. Celem niniejszej pracy jest zgromadzenie rezultatów wyników doświadczalnych uzyskanych różnymi technikami i znalezienie korelacji między nimi. Własności korozyjne stali stopowej (AISI 1026) w sztucznej wodzie morskiej zostały zbadane z wykorzystaniem ekstrapolacji tafelowskiej (TP), polaryzacji...
-
Self-Testing of Analog Parts Terminated by ADCs Based on Multiple Sampling of Time Responses
PublicationA new approach for self-testing of analog parts terminated by analog-to-digital converters in mixed-signal electronic microsystems controlled by microcontrollers is presented. It is based upon a new fault diagnosis method using a transformation of the set of voltage samples of the time response of a tested analog part to a square impulse into localization curves placed in a multidimensional measurement space. The method can be used...
-
Electric shock hazard in circuits with variable-speed drives
PublicationThe conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50/60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives...
-
Practical issues for the implementation of survivability and recovery techniques in optical networks
PublicationFailures in optical networks are inevitable. They may occur during work being done for the maintenance of other infrastructures, or on a larger scale as the result of an attack or large-scale disaster. As a result, service availability, an important aspect of Quality of Service (QoS), is often degraded. Appropriate fault recovery techniques are thus crucial to meet the requirements set by the Service Level Agreements (SLAs) between...
-
A method of self-testing of an analog circuit terminated by an ADC in electronic embedded systems controlled by microcontrollers
PublicationA new self-testing method of analog parts terminated by an ADC in electronic embedded systems controlled by microcontrollers is presented. It is based on a new fault diagnosis method based on on-line (i.e. during measurement), transformations of voltage samples of the time response of a tested part to a square pulse - onto localization curves placed in the measurement space. The method can be used for fault detection and single...
-
A method of self-testing of analog circuits based on fully differential op-amps with theTCBF classifier
PublicationA new approach of self-testing of analog circuits based on fully differential op-amps of mixed-signal systems controlled by microcontrollers is presented. It consists of a measurement procedure and a fault diagnosis procedure. We measure voltage samples of a time response of a tested circuit on a stimulation of a unit step function given at the common-mode reference voltage input of the op-amp. The fault detection and fault localization...
-
Five-phase induction motor drive with sine-wave filter
PublicationThe paper presents closed loop ac drive with 5 phase induction motor operating with voltage source inverter and sine wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed co ntrol can be applied. In the presence of output filter both control and estimation algorithms should be modified due to sine wave filter installation....
-
A testing method of analog parts of mixed-signal electronic systems equipped with the IEEE1149.1 test bus
PublicationA new solution of the JTAG BIST for testing analog circuits in mixed-signal electronic microsystems controlled by microcontrollers and equipped with the IEEE1149.1 bus is presented. It is based on a new fault diagnosis method in which an analog circuit is stimulated by a buffered signal from the TMS line, and the time response of the circuit to this signal is sampled by the ADC equipped with the JTAG. The method can be used for...
-
Tripping limitations of residual current devices in photovoltaic installations
PublicationIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...
-
Two‐functional μBIST for Testing and Self‐Diagnosis of Analog Circuits in Electronic Embedded Systems
PublicationThe paper concerns the testing of analog circuits and blocks in mixed‐signal Electronic Embedded Systems (EESs), using the Built‐in Self‐Test (BIST) technique. An integrated, two‐functional, embedded microtester (μBIST) based on reuse of signal blocks already present in an EES, such as microprocessors, memories, ADCs, DACs, is presented. The novelty of the μBIST solution is its extended functionality. It can perform 2 testing functions:...
-
Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
PublicationThe paper dealt with the issue of breakdowns detection of isolated hanging wires on the medium-voltage transmission. The main aim of article is to describe the function of created breakdowns detector and evaluation its. The breakdowns detector is created based in indicators of faults such as touch between tree limbs and insulated wire, touch tree limbs with several phases or fall insulated wire on the ground. Breakdowns detector...
-
Model-Free Controller Tuning Based on DFT Processing: Application to Induction Motor Drives
PublicationIn this paper, we present a new approach based on discrete Fourier transform (DFT) analysis for controller tuning of the closed-loop system with unknown plant. The DFT analysis is used to process the closed-loop measurements collected online to derive the frequency response of an initial closed-loop system that does not provide a good performance. Based on the closed-loop frequency response data, we propose two methods for tuning PID...
-
Application of data driven methods in diagnostic of selected process faults of nuclear power plant steam turbine
PublicationArticle presents a comparison of process anomaly detection in nuclear power plant steam turbine using combination of data driven methods. Three types of faults are considered: water hammering, fouling and thermocouple fault. As a virtual plant a nonlinear, dynamic, mathe- matical steam turbine model is used. Two approaches for fault detection using one class and two class classiers are tested and compared.
-
Comparative Evaluation of Multicoil Inductive Power Transfer Approaches Based on Z-source Network
PublicationThis paper describes comparative evaluation between wireless power transfer topologies with utilization of Z-source network. Paper describes components calculation method. List of open-loop, close-loop simulations were conducted to compare both topologies. Spectrum of signals is also researched.
-
OBSERVATION OF THE THERMOSIPHON EFFECT IN THE CIRCULATION OF ACETONE AS WORKING FLUID IN MODERN COOLING SYSTEM
Publicationplants or computer server rooms has led to the demand for new and reliable methods for electronic cooling. Because of bigger and bigger power levels and miniaturization of the electronic devices, lack of free space in such a high heat flux. The increasing integration of electronic logy that supposed to be designed for high thermal performance, low mass, and able to work in harsh environments. In this paper presented a prototype...
-
A solution of the integrated µBIST for functional and diagnostic testing in mixed-signal electronic embedded systems
PublicationMain problem of the paper is testing of analog circuits and blocks in mixed-signal electronic embedded systems (EESs), using the built-in self-test (BIST) technique. The integrated mBIST based on reusing signal blocks already present in an EES, such as processors, memories, ADCs, is presented. The novelty of the solution is the extended functionality of the mBIST. It can perform 2 testing functions: functional testing and fault...
-
Improving Control Dynamics of PMSM Drive by Estimating Zero-Delay Current Value
PublicationDynamic performance of current control loop still remains crucial for position-, speed-, and torque-controlled drives. In the study, a current loop solution has been designed for field oriented control of permanent magnet synchronous motors (PMSM). It enhances typical PI controller with an estimator of zero-delay current (ZDC) value. The ZDC estimation allows for selecting substantially higher controller gain. It reduces control...
-
Zastosowanie sygnałów o projektowanych kształtach do diagnostyki obiektów wysoko-impedancyjnych metodą spektroskopii impedancyjnej
PublicationW artykule przedstawiono metodę szybkiej spektroskopii impedancyjnej obiektów o wysokich impedancjach (|Zx| > 1 GOhm) z zastosowaniem sygnałów o projektowanych kształtach. Sygnał pobudzenia wytwarzany jest w module DAQ U2531A i doprowadzany na wejście badanego obiektu za pośrednictwem przetwornika cyfrowo-analogowego (CA). Sygnały odpowiedzi proporcjonalne do napięcia na mierzonej impedancji Zx oraz prądu płynącego przez Zx są...
-
Iterative Global Sensitivity Analysis Algorithm with Neural Network Surrogate Modeling
PublicationGlobal sensitivity analysis (GSA) is a method to quantify the effect of the input parameters on outputs of physics-based systems. Performing GSA can be challenging due to the combined effect of the high computational cost of each individual physics-based model, a large number of input parameters, and the need to perform repetitive model evaluations. To reduce this cost, neural networks (NNs) are used to replace the expensive physics-based...
-
Resonance problems in UHV transmission lines
PublicationThe paper presents resonance phenomena observed in 400 kV transmission lines in the Polish power system. Two events are analysed, when shunt reactors used for reactive power compensation, caused overvoltages and overcurrent protection tripping as a result of resonance. An oscillographic fault recordings from protection devices are compared to time domain simulation results. The obtained simulation results match fault recordings,...
-
Service-based Resilience via Shared Protection in Mission-critical Embedded Networks
PublicationMission-critical networks, which for example can be found in autonomous cars and avionics, are complex systems with a multitude of interconnected embedded nodes and various service demands. Their resilience against failures and attacks is a crucial property and has to be already considered in their design phase. In this paper, we introduce a novel approach for optimal joint service allocation and routing, leveraging virtualized...
-
Residual current devices in electric vehicles charging installations
PublicationThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...
-
Programmable dynamically changing RC model for evaluation of Dynamic EIS methods and instrumentation
PublicationThe paper concerns the RC equivalent circuit of electrochemical cell with the impedance changed during the experiment. The model was constructed using the digital potentiometers controlled by the microcontroller. This solution allows to control the model impedance by the software means. By creating adequate changes of the impedance spectrum as a time function, the different impedance measurement method can be tested to find out...
-
Redundantly Actuated 3RRR Parallel Planar Manipulator - Numerical Analyses of its Dynamics Sensitivity on Modifications of its Platform’s Inertia Parameters
PublicationIn the paper, numerical analyses, as well as dynamics of a complex mechanism, are presented. Two objectives are crucial for the paper: inverse dynamic model is needed (dedicated to be use in the model predictive controller); an identification method is searched (some trajectory parameters are controlled, when specific trajectory is tracked under an open-loop model-based control), as selected parameters must be identified for the...
-
Rurka ciepła z pętlą obiegową jako urządzenie do odzysku ciepła
PublicationW pracy przedstawiono możliwości odzysku ciepła za pomocą rurki ciepła z pętlą obiegową (ang. loop heat pipe)
-
Multichannel self-optimizing narrowband interference canceller
PublicationThe problem of cancellation of a nonstationary sinusoidal interference, acting at the output of an unknown multivariable linear stable plant, is considered. No reference signal is assumed to be available. The proposed feedback controller is a nontrivial extension of the SONIC (self-optimizing narrowband interference canceller) algorithm, developed earlier for single-input, single-output plants. The algorithm consists of two loops:...
-
Indirect adaptive controller based on a self-structuring fuzzy system for nonlinear modeling and control
PublicationIn this paper, a unified nonlinear modeling and control scheme is presented. A self-structuring Takagi-Sugeno (T-S) fuzzymodel is used to approximate the unknown nonlinear plant based on I/O data collected on-line. Both the structure and theparameters of the T-S fuzzy model are updated by an on-line clustering method and a recursive least squares estimation(RLSE) algorithm. The rules of the fuzzy model can be added, replaced or...
-
Improvement of time difference of arrival measurements resolution by using fractional delay filters in a direct sequence-code division multiple access radionavigation system
PublicationThis study presents a method of improving time measurements resolution in a direct sequence-code division multiple access receiver by using a fine code tracking loop based on fractional delay filtering of a despreading sequence. It briefly describes the structure of a generic digital code tracking loop and the proposed modification which allows to measure time difference of arrival values with the subsample resolution, together...
-
Optimising approach to designing kernel PCA model for diagnosis purposes with and without a priori known data reflecting faulty states
PublicationFault detection plays an important role in advanced control of complex dynamic systems since precise information about system condition enables efficient control. Data driven methods of fault detection give the chance to monitor the plant state purely based on gathered measurements. However, they especially nonlinear, still suffer from a lack of efficient and effective learning methods. In this paper we propose the two stages learning...
-
Local properties of organic coatings close to glass transition temperature
PublicationAcrylic coating applied on copper substrate has been investigated at different temperatures starting from the ambient one up to the level above the glass transition temperature. Its local topographic and electric properties have been examined with the atomic force microscopy (AFM) based approach including dc current mapping and local impedance spectroscopy. The local findings have been compared with the information from global...
-
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublicationEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Low-frequency tripping characteristics of residual current devices
PublicationFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
A method of measuring RLC components for microcontroller systems
PublicationA new method of measuring RLC components for microcontroller systems dedicated to compact smart impedance sensors based on a direct sensor-microcontroller interface is presented. In the method this direct interface composed of a reference resistor connected in series with the tested sensor impedance is stimulated by a square wave generated by the microcontroller, and then its voltage response is sampled by an internal ADC of the...
-
Electrical Propterties of Solution Mixtures for Bath Supervision in Ambient Assisted Living
PublicationImpedance properties of bath solution are compared. Any ingredient such as soap, shampoo or bathing salt changes bath-solution’s electrical properties eg. impedance. We have measured and analysed influence of typical bathing ingredients on electrical properties of the solution. We investigate impedance changes over frequency range from 100Hz tu 100kHz as it is most applicable for person detection. Electrical properties of bath...
-
Szybkie uziemniki do ograniczania skutków zwarć łukowych w okrętowych rozdzielnicach SN
PublicationW artykule scharakteryzowano moc i napięcie łuku, jak również przedstawiono model termodynamiczny służący do obliczania ciśnienia i temperatury gazów w otoczeniu łuku zwarciowego. Przedstawiono przykładowy układ elektrowni okrętowej i zasilania najważniejszych odbiorników na statku do przewozu gazu ziemnego w stanie ciekłym. Na podstawie parametrów prądnic i silników odbiorników zasilanych z rozdzielnicy głównej obliczono prądy...
-
Parametry uziemień przy przebiegach udarowych i wysokoczęstotliwościowych
PublicationW artykule skupiono się na porównaniu dwóch metod badania impedancji uziemienia odgromowego: udarowej z wysoką częstotliwościową. Zestawiono wyniki pomiarów istniejących uziemień z wynikami komputerowych obliczeń symulacyjnych przeprowadzonych w środowisku programu PSIM. Uzyskane wyniki wskazują na poprawność przyjętego toku modelowania, a uzyskane w ten sposób dane mogą być przydatne w fazie projektowania do szacowania...
-
Price convergence in the European Union and in the new member states
PublicationThis paper examines price dispersion in the European Union (EU15) and in three New Member States (Poland, Hungary and the Czech Republic) between 1995 and 2006. The analysis utilizes both disaggregate and aggregate price data, including the prices of 157 products and two indices constructed using two different weighting procedures. For each category of goods the price dispersion is lower in EU15 than EU15 plus 3 NMS. Sigma convergence...
-
Demonstrator testera wbudowanego BIST dla układów w pełni różnicowych
PublicationPrzedstawiono demonstrator testera wbudowanego, przeznaczony do pracy na stanowisku dydaktycznym w laboratorium z przedmiotu Zaawansowane Metody Pomiarowe i Diagnostyczne. Na stanowisku studenci zapoznają się z technologią BIST (ang. Built-In Self-Test), która jest przykładem wdrożenia strategii projektowania dla testowania.
-
Evaluation of organic coatings condition with AFM-based method
PublicationThe paper presents an atomic force microscopy (AFM)-based approach to evaluation of local protective properties of organic coatings. Apart from topography, it provides local ac and dc characteristics of examined coating. The method consists in application of ac voltage perturbation signal between conductive AFM tip and coated metal substrate. The resulting current is used to determine local impedance characteristics. Both impedance...
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublicationThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Influence of vacuum sublimation deposited metal layer thickness on metrological parameters of the amperometric gas sensor with Nafion membrane
PublicationThe paper presents the results of investigation on an influence of vacuum sublimation deposited platinum layer thickness on the signal, sensitivity and response time of a prototype of sulphur dioxide sensor with Nafion membrane. The working electrode was made by vacuum sublimation deposition of platinum on a surface of Nafion membrane. Pt layers deposited changed an initial structure of Nafion membrane and that phenomenon was utilized...
-
Use of Neural Networks in Diagnostics of Rolling-Element Bearing of the Induction Motor
PublicationBearing defect is statistically the most frequent cause of an induction motor fault. The research described in the paper utilized the phenomenon of the current change in the induction motor with bearing defect. Methods based on the analysis of the supplying current are particularly useful when it is impossible to install diagnostic devices directly on the motor. The presented method of rolling-element bearing diagnostics used indirect...
-
Adaptive estimation of the transformer stray capacitances for DC–DC converter modelling
PublicationNew low cost and accurate estimation method of transformer stray capacitances for wide band DC–DC converter modelling and design is proposed. The Wiener filter (WF) method is applied to estimate the transformer impedance – referred to the selected transformer winding configurations. Laboratory tests are used to adapt the filter, that is to find optimal impedance which minimises mean square error between measured, noise perturbed...
-
Optimal retrofit strategy using viscous dampers between adjacent RC and SMRFs prone to earthquake‑induced pounding
PublicationNowadays, retrofitting-damaged buildings is an important challenge for engineers. Finding the optimal placement of Viscous Dampers (VDs) between adjacent structures prone to earthquake-induced pounding can help designers to implement VDs with optimizing the cost of construction and achieving higher performance levels for both structures. In this research, the optimal placement of linear and nonlinear VDs between the 3-story, 5-story,...