Filters
total: 375
filtered: 183
-
Catalog
Chosen catalog filters
Search results for: CURRENT MEASUREMENT
-
Remote current measurement with FPGA digital processing
PublicationThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
Current measurement and analysis for induction motor diagnostics
PublicationPrzedstawiono sposób diagnozowania łożysk tocznych w silnikach indukcyjnych z wykorzystaniem pomiarów i analizy prądu zasilającego silnik. Zaprezentowano metodę pomiarową i opracowania danych diagnostycznych. Uzyskano zgodność częstotliwości składowych widma prądu otrzymanych z badań teoretycznych i eksperymentalnych.Podano wyniki badań łożysk o róznych uszkodzeniach i prawdopodobieństwa poprawnych diagnoz.
-
Comparison of induction motor bearing diagnostic test results through vibration and stator current measurement
PublicationThe paper discusses results of tests performed by authors, related to the angine bearings diagnostic using vibration and stator current measurements. The paper contains the description of an automatic measurement system, developed for measurement of those harmonics and processing that to obtain bearing diagnostic information. System was tested on objects with intentionally made defects in bearings, results of this test was also...
-
Leakage Current Measurements of Surge Arresters
PublicationThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...
-
Measurement cell - current density analysis.
PublicationW pracy przedstawiono model celki do pomiarów elektrycznych parametrów szkliwa i innych tkanek zęba. Wyniki otrzymano za pomocą metody elementu skończonego. Wykazano, że możliwa do osiągnięcia dokładność pomiaru jest zdeterminowana przez prąd upływu celki.
-
Visual measurement system for chosen parameters of current collectors
PublicationA current collector is an element in a traction vehicle, used for movable, contact con-nection between the main circuit of this vehicle and the contact line. Bad technical condi-tion of these important elements in the main circuit of the vehicle result in its incorrect cooperation with contact line. Periodic control of technical condition of current collectors ensures infallible current collection. The pantograph diagnostics consists...
-
Method and measurement system for DC characteristics measurement of power diodes in very wide current range
PublicationW artykule przedstawiono układ pomiarowy do pomiaru charakterystyk stałoprądowych diod. Pomiar przeprowadzany jest metodą impulsową w celu zapewnienia stałej temperatury badanego elementu w trakcie pomiaru. Do zapewnienia odpowiedniej liczby punktów pomiarowych wykorzystano układ zmodyfikowanej drabinki R2R z pojedynczymi kluczami sterującymi.
-
Indirect Measurement of Motor Current Derivatives in PMSM Sensorless Drives
PublicationMotor current derivatives contain useful information for control algorithms, especially in sensorless electric drives. The measurement of motor current derivatives in electric motors supplied by voltage source inverter can be performed using di/dt transducers. However, in such a solution additional sensors have to be installed, e.g. Rogowski coils. Another approach is to measure current derivatives indirectly – by oversampling...
-
Dead-Time Effect Compensation Based on Additional Phase Current Measurements
PublicationThis paper proposes a new method of dead-time effect compensation. The proposed solution is based on additional phase current measurements realized by analog-to-digital converters. These measurements are carried out at the time instants specified by a pulsewidth-modulation (PWM) strategy. This makes it possible to estimate inverter currents at the commutation instants and, finally, to estimate the voltage error caused by dead time. This...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublicationW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublicationThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
Optoelectronic properties of the metal-tetracene interface investigated by current noise measurement under monochromatic irradiation.
PublicationZaprezentowano badania prądów ograniczonych elektrodowo w warstwach tetracenu. Szczególną uwagę zwrócono na zależność szumów elektrycznych od przyłożonego napięcia i padającego światła.
-
O zastosowaniu metody prądów wirowych do technicznego pomiaru własności elektrycznych i magnetycznych metali = About application of eddy current method for technical measurement of electric and magnetic properties of metals
PublicationOpisano wyniki badań nad wykorzystaniem efektu prądów wirowych do badania własności elektrycznych i magnetycznych metali. Badania wykonano za pomocą sondy różnicowej. Wyniki pomiarów zależności częstotliwościowej wykonane dla modelowych materiałów porównano z wynikami modelowania metodą elementów skończonych.
-
Current divider-based nanosecond high current pulse measuring systems
PublicationThis paper presents the analysis of the new approach to the measurement methodology of significant values (in order of hundreds of kA) and huge steepness (in order of MA/μs) current pulses based on current dividers along with a comparison of the various types transducers suitability in measuring systems with such extreme parameters. Such dividers are used to extend the measurement ranges of current transducers with limited current...
-
Influence of vision measurement system spatial configuration on measurement uncertainty, based on the example of electric traction application
PublicationTechnical diagnostics plays a significant role in ensuring operational reliability of electrified rail transport. The most critical point in the transmission of electric energy to vehicles is the sliding contact of the current collector with the traction network. For this reason, work is currently being carried on new measuring methods, whose appliance allows for more complete diagnostics of the contact line and current collectors,...
-
Measurement methods for assessing insulation condition of underground pipelines
PublicationThe paper discusses the most frequently applied measurement methods for assessing the quality of external insulation along pipelines and detecting defect locations in the protective coating. The quality of coating along a given pipeline section under investigation is assessed by determining unitary resistance of the coating, which is calculated on the basis of measurement results obtained along a pipeline subjected to cathodic...
-
Determining the leakage current resistive component by the orthogonal vector method
PublicationThe measurement of the metal – oxide surge arresters (MOSA) leakage current and the analysis of its components is a key diagnostic criterion according to technical standards. During on site MOSA condition assessment, the easy way is based on the measurement only leakage current, without the inconvenient live working measurements of supply voltage. Orthogonal vectors method of determination the resistive leakage current is presented....
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublicationVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Residual Current Devices: Selection, Operation, and Testing
PublicationIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublicationA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Technical diagnostics and monitoring of traction current collectors
PublicationNew evaluation methods of the technical condition of rolling stock current collectors are proposed in this paper. The method of automatic measurement of the pantograph static force characteristic, realized when the vehicle runs through the test section of the track with especially prepared overhead line height distribution, has been practically implemented by the Polish Railways. The method of testing the slipper spring suspension...
-
The issue of uncertainty of visual measurement techniques for long distance measurements based on the example of applying electric traction elements in diagnostics and monitoring
PublicationRail transport is the most economical and energy-effective in the field of land transport, in particular electrified. In order to ensure efficient and reliable operation of electrified rail transport, the issues of monitoring and diagnostics of the traction infrastructure and vehicles are extremely important. The most critical point in the transmission of electric energy to the vehicle is the sliding contact of the current collector...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Using A Particular Sampling Method for Impedance Measurement
PublicationThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Evaluation of expanded uncertainty of instantaneous power measurement in a bearing diagnostic system.
PublicationThe paper presents the issues concerning the estimation of the expanded uncertainty in the system for the diagnosis of rolling bearings, consisting of transducers: voltage and current voltage, which is used for diagnostic bearing motors method based on the measurement and analysis of the instantaneous power signal consumed by the induction motor. It presents the methodology for assessing the measurement uncertainty and presents...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Low-power device simulator for micro-energy measurement methods testing
PublicationThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor
PublicationDiagnosis of induction motors, conducted remotely by measuring and analyzing the supply current is attractive with the lack of access to the engine. So far there is no solution, based on analysis of current, the credibility of which allow use in industry. Statistics of IM bearing failures of induction motors indicate, that they constitute more than 40% of IM damage, therefore bearing diagnosis is so important. The article provides...
-
Current-based higher-order spectral covariance as a bearing diagnostic feature for induction motors
PublicationConducting the diagnosis of induction motors remotely by analyzing the supply current is an attractive prospect with the lack of access to the engine. Currently, there is no solution, based on analysis of the current, the credibility of which would allow its use in industry. The statistics of bearing failures in induction motors indicate that they constitute more than 40% of induction motor damage, therefore, bearing diagnosis...
-
An Innovative New Approach to Light Pollution Measurement by Drone
PublicationThe study of light pollution is a relatively new and specific field of measurement. The current literature is dominated by articles that describe the use of ground and satellite data as a source of information on light pollution. However, there is a need to study the phenomenon on a microscale, i.e., locally within small locations such as housing estates, parks, buildings, or even inside buildings. Therefore, there is an important...
-
Sensorless IPMSM drive with rotor position estimator based on analysis of phase current derivatives
PublicationThis paper describes a sensorless Interior Permanent Magnet Synchronous Motor (IPMSM) drive designed for traction applications. Wide-speed sensorless operation is provided with the use of three methods of rotor position estimation designed for: a standstill, low- and high-speed range. The paper focuses on the high-speed estimation algorithm. The estimator uses the derivatives of motor phase currentsresulting from PWM modulation...
-
Experimental verification of visual method for measuring displacements of contact line elements
PublicationThe increase of rail vehicles speed, as well as the increase of their power, puts high demands on the power delivery system for traction vehicles The most critical point in the vehicle's power supply circuit is the contact between the current collector and contact wires. Ensuring a reliable co-operation of the current collector and contact line, requires technical development...
-
STUDY OF ARRAY OF MEMS INERTIAL MEASUREMENT UNITS UNDER QUASI-STATIONARY AND DYNAMIC CONDITIONS
PublicationA measurement system includes all components in a chain of hardware and software that leads from a measured variable to processed data. In that context, the type and quality of the sensors or measuring devices are critical to any measurement system. MEMS/IMU sensors lag behind leading technologies in this respect, but the MEMS/IMU performance rapidly changes while is relatively inexpensive. For this reason, the paper proposes...
-
Influence of span length and impulse front time on earthing measurement accuracy of power line towers
PublicationThe article discusses the issue of measuring and assessing the features of power line tower earthings using fast-changing waveform. The study analyses the effect of impulse front time and the line span length on errors made during these measurements using impulse meters. It has been found that the assessment conditions similar to the static measurement results occur for the use of 4 μs current impulses and such procedure is useful...
-
Wear estimation of current collector contact strips by analysis of a 3D scanning results
PublicationThe technical condition of current collector contact strips is very important when operational reliability of railway transportation is considered. The authors proposed a novel measurement system based on a 3D camera to register the shape and dimensions of the current collector contact strips surface. The system was installed above the railway track for tests in target ambient. During the trial operation a few dozen of contact...
-
The concept of estimation of elevator shaft control measurement results in the local 3D coordinate system.
PublicationGeodetic control measurements play an important part because they provide information about the current state of repair of the construction, which has a direct impact on the safety assessment of its exploitation. Authors in this paper have focused on control measurements of the elevator shaft. The article discusses the problem of determining the deviation of elevator shaft walls from the vertical plane in the local 3D coordinate...
-
The method of location and identification of weak electric field source in seawater
PublicationThe paper presents the method and measurement system that allows to lacate the detected object and to identify parameters of its simplified model in form of a current dipole.
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublicationThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Analysis of thoracic regional impedance changes using PCA approach
PublicationA multichannel impedance and one lead electrocardiographic recording system has been developed. The impedance measurement unit is built using a four-electrode technique. It consists of a sinusoidal, 40 kHz, current source and five measurement channels. Circumferential current electrodes have been located at a neck and an abdomen. Voltagemeasurement disk electrodes formed five two-electrode measurement ports. The impedance change...
-
Effect of the let-through energy of overcurrent protective devices on the temperature of conductors during short-circuits
PublicationThe scope of the verification of low-voltage systems covers the earth fault loop impedance measurement. This measurement is usually performed with the use of low-value current meters, which force a current many times lower than the one occurring during a real short-circuit. Therefore, the international standard recommends consideration of the increase of resistance of conductors with the increase of temperature, which may occur...
-
Metrological analysis of an computerized system of protection against electric shock in circuits with variable speed drives
PublicationDrive systems, that can be operated at variable speed, are equipped with power electronics converters. This causes distortion of the earth current, and consequently the need to take into account the use of proper protective devices in relation to earth current harmonics. This paper presents a system for protection against electric shock in circuits with power electronics converters and metrological analysis indicating the requirements...
-
3D Machine Vision System for Inspection of Contact Strips in Railway Vehicle Current Collectors
PublicationConstruction and technical condition of current collectors is crucial to reliability and safety of railway transportation. According to the Technical Specifications for Interoperability railway vehicles in the European Union should be equipped with carbon contact strips. Excessive wear or defects of contact strips degrade the capability of undisturbed power transmission, cause faster wear of contact wire, and can even result in...
-
Old-timer Vehicle - Braking Efficiency Measurement at Vehicle Inspection Stations and Roadworthiness Validity Certificate.
PublicationObtaining the Roadworthiness Validity Certificate for an old-timer vehicle involves an appropriate test performance, namely, "Old-timer Vehicle Technical Specification Compliance Test". It seems obvious that this kind of test should include a considerable checklist, however, the current legal regulations connected with this test are not specific enough. One of the certificates issued on this test results is "Old-timer Vehicle Technical...
-
Hydrogen sulphide electrocatalytic gas sensor
PublicationIn this article measurement results of the electrocatalytic gas sensor in different concentrations of hydrogen sulphide are presented. Working principle of such sensor is based on electric current acquisition, while voltage ramp is applied to the sensor. During voltage sweep oxidation and reduction reactions occurs on the sensor electrodes. Obtained current-voltage plot has unique shape connected...
-
Testing of Software for the Planning of a Linear Object GNSS Measurement Campaign under Simulated Conditions
PublicationThe precision of a linear object measurement using satellite techniques is determined by the number and the relative position of the visible satellites by the receiver. The status of the visible constellation is described by DOP. The obtained geometric coefficient values are dependent on many variables. When determining these values, field obstacles at the receiver location and satellite positions changing with time must be taken...
-
Analysis of measurement uncertainty for contact-less method used to measure the position of catenary contact wire, performed with the use of Monte Carlo method
PublicationCurrently the majority of main railway lines in Europe are electrified, and electric trains have the biggest share in the entire amount of rail transport. Reliability of electrified railways is closely related to the issue of supplying traction vehicles with energy. The problems connected with diagnostics of energy consumption node, namely the contact line and the current collector, are therefore of fundamental importance for maintaining...
-
Diagnostics of induction motor bearings - possibility of measurements
PublicationIn induction motors damage in the elements of electromagnetic system, for example in the wiring of stator, rotor or in the magnetic circuit can appear as well as damage of mechanical parts (bearings, rotor, shaft). Bearing diagnostics is so important in supervision of motor condition, because extensive research shows that the bearings arethe elements most susceptible to damage. This paper presents the research which the author...