Filters
total: 344
filtered: 209
-
Catalog
Chosen catalog filters
Search results for: LOAD TESTS
-
Dynamic load tests of piles in non-cohesive soils.
PublicationThe results of investigations of various types of piles, the analysis of dynamic tests carried out recently in Poland and the correlations between the results of dynamic and static tests of piles are presented. Przedstawiono wyniki badań nośności różnych rodzajów pali, analizę badań dynamicznych wykonanych w Polsce w ostatnich latach oraz korelacje pomiędzy wynikami badań statycznych i dynamicznych.
-
Load Tests of the Movable Footbridge Over the Port Canal in Ustka
PublicationThe paper presents the acceptance tests carried out on the open footbridge over the port canal in the Port of Ustka. The steel footbridge construction is created by a single pylon to which a movable truss span is suspended with a theoretical span of 52.3 m. The studies about load test of the object included static and dynamic extortion and measurements. In static tests the ballast was of pallets with concrete blocks. Dynamic studies...
-
Identification of residual force in static load tests on instrumented screw displacement piles
PublicationOccurrence of the so-called residual force of an unknown value significantly disturbs interpretation of static load tests performed on piles equipped with additional measuring instruments. Screw displacement piles are the piling technology in which the residual force phenomenon is very common. Its formation mechanism is closely related to the installation method of this type of piles, which initiates generation of negative pile...
-
Bearing capacity of piles based on static load tests and calculation principles provided by EN 1997-1
PublicationW artykule scharakteryzowano i przeanalizowano ogólne zalecenia Eurokodu 7 dotyczące wyznaczania nośności pali na podstawie próbnych obciążeń statycznych. Porównano je z zaleceniami dotychczasowej polskiej normy PN-83/B-02482. Przedstawiono kilka przykładów interpretacji rzeczywistych wyników próbnych obciążeń pali według zaleceń wyżej wymienionych dwóch norm wraz z analizą porównawczą.
-
The assessment of load-settlement curve for Atlas piles correlated with CPT tests
PublicationRacjonalne stosowanie pali przemieszczeniowych typu Atlas wymaga analitycznej oceny pełnej krzywej obciążenie - osiadanie. W pracy przedstawiono możliwości wykorzystania metody funkcji transformacyjnych t-z (dla pobocznicy) oraz q-z (dla podstawy) dla oceny krzywej osiadania. Jednostkowe graniczne opory na pobocznicy, tmax, oraz pod podstawą, gf, określono na podstawie metody bezpośredniej, wykorzystując opory stożka sondy, qc....
-
Analysis of the cyclic load-unload-reload tests of VALMEX aged fabric
PublicationThe paper presents mechanical response of the VALMEX fabric during the cyclic loading-unloading and re-loading experiments. Two types of the aged material used for nearly 20 years as the roofing of the Forest Opera in Sopot (Poland) have been tested. The results have been separately obtained for the warp and fill di-rections. The comparative analysis has revealed that the material aged in service is more durable in the fill di-rection,...
-
Load capacity of steel-aluminium brackets under static and cyclic laboratory tests
PublicationThe aim of the research is the laboratory investigation of steel-aluminium brackets employed to fasten lightweight curtain walls to building facilities. Static pressure, suction forces, and cyclic loads parallel to end plates (horizontal – to simulate wind influence) were applied in the study. The steel-aluminium brackets were tested on a reinforced concrete substrate made of C30/37 concrete class to simulate the real working conditions....
-
Comparison the heat load as the results of tests on human subject in a hot environment with the results obtained from numerical simulation
Publication -
Displacement measurements during load testing of railway arch bridge
PublicationThe paper discusses issues concerning load tests carried out on a twin-track, arch railway bridge over the Martwa Wisla river in Gdansk. Currently, it is the bridge with the longest span in its class in Poland. The load-bearing structure consists of three no-hinge arches and an orthotropic deck suspended from them. The studies of the structure assumed the performing of static and dynamic tests. The paper presents the method for...
-
Application of probabilistic tools to extend load test design of bridges prior to opening
PublicationLoad tests of bridges are widely performed in a large number of countries. Deterministic comparison of measurement results to the theoretical, FEM (finite element method)-based outcomes with possible further calibration is mostly applied. Sometimes, the data collected in the tests are also used to calibrate the reliability factors of bridge structures or their components. This work proposes to complement the stage of the load test...
-
Load Testing of GFRP Composite U-Shape Footbridge
PublicationThe paper presents the scope of load tests carried out on an innovative shell composite footbridge. The tested footbridge was manufactured in one production cycle and has no components made from materials other than GFRP laminates and PET foam. The load tests, performed on a 14-m long structure, were the final stage of a research program in the Fobridge project carried out in cooperation with: Gdańsk University of Technology (leader),...
-
Load-settlement characteristics of piles working in a group
PublicationLoad-settlement characteristic (Q-s) of an axially loaded pile can be empirically determined from a static pile load test or on the basis of calculations using, e.g. transfer functions or numerical methods (FEM). The transfer functions method usually rely on empirical data, i.e. the function parameters are determined on the basis of numerous pile test results. Thus this method takes into account pile installation technology and...
-
Load testing of a suspended footbridge in Radom (Poland)
PublicationThe footbridge in Radom is a suspended bridge of an interesting architectural form. The structure was de-signed for 4 kN/m2 of crowd loading. Dynamic calculations were not included in the design. The structure’s acceptance tests took place on the 14th of October 2016. The behaviour of the footbridge in static testing met the expectations. Unfortunately, as a result of dynamic tests, dangerous behaviour of the footbridge was revealed....
-
Experimental tests for the determination of mechanical properties of PVC foil
PublicationThe paper presents an application of the PVC film in civil engineering. Mechanical behaviour of the PVC film applied for suspended ceilings, in the form of a stretch ceiling is investigated under uniaxial and biaxial tensile tests. The study is focused on the determination of mechanical properties from experimental data (uniaxial and biaxial tensile tests). The uniaxial cyclic tests are performed in order to observe a variation...
-
Load test of new European record holder in span length among extradosed type bridges
PublicationThe article presents acceptance load tests of a newly built extradosed MS-3 bridge located along the national road DK-16 near Ostróda (Poland). The structure features significant dimension in European reference scale. It is a new record holder in span length regarding this distinct bridge category. Its length ranges 206 m. Static and dynamic load tests were performed here. The program was extended by entire structural laser scanning...
-
Mechanical properties of polyvinyl chloride-coated fabric under cyclic tests
PublicationThe aim of the present paper is to propose a method of laboratory tests necessary for the identification of mechanical properties of the coated fabric. The material parameters of the coated fabric AF 9032 are specified on the basis of the uniaxial and biaxial tensile tests. For the identification process, the techniques based on the least squares methods are used. Additionally, the uniaxial and biaxial cyclic tests are performed...
-
Static load test on concrete pile – instrumentation and results interpretation
PublicationFor some time (since 8-10 years in Poland) a special static load tests on instrumented piles are carried out. Such studies are usually of a scientific nature and provide detailed quantitative data on the load transfer into the ground and characteristics of particular soil layers interaction with a pile shaft and pile base. Deep knowledge about the pile-subsoil interaction can be applied for a various design purposes, e.g. numerical...
-
Mechanical properties of PVDF-coated fabric under tensile tests
PublicationThis article describes the laboratory tests necessary to identify the mechanical properties of the polyvinylidene fluoride (PVDF)-coated fabrics named Precontraint 1202S and Precontraint 1302S. First, a short survey of the literature concerning the description of coated woven fabrics is presented. Second, the material parameters for PVDF-coated fabrics are specified on the basis of biaxial tensile tests. A comparison of the 1:1...
-
Static Load Test on Instrumented Pile – Field Data and Numerical Simulations
PublicationFor some time (since 8-10 years in Poland) a special static load tests on instrumented piles are carried out. Such studies are usually of a scientific nature and provide detailed quantitative data on the load transfer into the ground and characteristics of particular soil layers interaction with a pile shaft and pile base. Deep knowledge about the pile-subsoil interaction can be applied for a various design purposes, e.g. numerical...
-
Pile Model Tests Using Strain Gauge Technology
PublicationOrdinary pile bearing capacity tests are usually carried out to determine the relationship between load and displacement of pile head. The measurement system required in such tests consists of force transducer and three or four displacement gauges. The whole system is installed at the pile head above the ground level. This approach, however, does not give us complete information about the pile-soil interaction. We can only determine...
-
Experimental tests of lintel hybrid beams
PublicationThe results of experimental tests of lintel hybrid beams made of air concrete and prestressed concrete were presented in paper. Blocks of air concrete was a protective element for the construction one. The length of hybrid beams was 3.0 m, while total height 27 cm. It was assumed that hybrid beams will work in the simply-supported scheme (with a 10 cm support) loaded uniformly over the entire length. The object of the tests were...
-
Mechanical properties of Precontraint 1202S coated fabric under biaxial tensile test with different load ratios
PublicationThe paper describes a method of laboratory tests necessary for identifying the mechanical properties of polyester coated fabrics named Precontraint 1202S with PVDF surface treatment. Two sets of initial material parameters for dense net model and orthotropic model are specified. Material parameters for Precontraint 1202S coated fabric are specified on the basis of the biaxial tensile tests for different load ratios. In order to...
-
Experimental tests of steel double-type balcony connections
PublicationThe paper presents analysis and results of experimental tests of full scale prefabricated balcony sets with dimensions (width × length × height): 2.0 m × 2.78 m × 0.186 m (in slope to 0.17 m). The sets consists of reinforced concrete slabs (balcony and ceiling) connected with each other by double-type balcony connections. The paper analyses the impact of variable parameters on the load carry capacity of elements. Additionally...
-
Establishing Relationships between Parameters of the controlled Compaction Soil by Using Various In-Situ Tests
PublicationThe aim of research was evaluating reliable correlations between chosen soil parameters describing state of surface layers of soil. The paper presents site comparative tests based on the light falling weight deflectometer (LFWD), the static plate load tester (VSS), the dynamic probing light tester (DPL) and the bearing ratio tester (CBR in-situ) with relationships between soil state parameters. All featured in-situ...
-
STABILITY AND LOAD BEARING CAPACITY OF A BARS WITH BUILT UP CROSS SECTION AND ELASTIC SUPPORTS
PublicationThe present paper is devoted to the numerical analysis and experimental tests of compressed bars with built–up cross section which are commonly used as a top chord of the roof trusses. The significant impact on carrying capacity for that kind of elements in case of out-of-plane buckling is appropriate choice of battens which are used to provide interaction between separate members. Linear buckling analysis results and nonlinear static...
-
Retrievable strain measuring system in screw displacement piles - readings and results interpretation problems
PublicationStatic load tests on foundation piles are generally carried out in order to determine load – displacement characteristic of the pile. For more detailed information, e.g. force distribution along the shaft, load transfer mechanism and characteristics of soil-structure interaction (unit resistance curves t-z, q-z) additional pile instrumentation is required. Most popular techniques focus on direct concrete strain measurements and...
-
Numerical Determination of the Load-Bearing Capacity of a Perforated Thin-Walled Beam in a Structural System with a Steel Grating
PublicationThis article presents the results of numerical simulations of a structural system consisting of steel perforated thin-walled beams and a steel grating. The simulations were conducted using the finite element method. The analysis took into account physical and geometric nonlinearity as well as the contact between the steel grating and the beams. The main goal of the research was to develop load-bearing curves for the main beam in...
-
Hydrogen induced degradation of structural steel exposed to the technical liquid hydrocarbons
PublicationSusceptibility of the differently heat treated 26H2MF steel to stress corrosion cracking has been evaluated in the constant strain rate tension tests done at the strain rate 10-6s-1 and in the constant load tests done at the 0,98 of fracture load. The boiler fuel and the aged mineral oil at 135C and 80C respectively, have been used as the aggressive environments.
-
Sustainable development requires risky decisions - problematic 300 ton overweight transport passing a bridge
PublicationOversize load passages over bridges are one of the research issues related to sustainable development that engineering and scientific teams around the world have to deal with . The article presents the scope of activities that enabled the passage of an oversized vehicle with a total weight of over 300 tons over a reinforced concrete slab. The bridge load capacity is 30 tons. In order to assess the capacity of the bridge, detailed...
-
Shaft friction from the DMT and direct shear interface tests
PublicationThe article presents preliminary attempt to create tri-linear transfer curves for describing pile behaviour under axial loading. Transfer curves would use the parameter measured in dilatometer test, particularly a constrained modulus MDMT. The proposed method is based on concrete rough and smooth interface tests performed in a direct shear apparatus. Based on the obtained mobilization curves, relationships were created between...
-
Load carrying capacity of the eccentric joint in the truss made of open cross-sections
PublicationThe influence of eccentricity at intersections of truss members on the load carrying capacity of the truss joint is presented in the paper. The research truss elements were designed as cold-formed open cross section. Analytical calculations, numerical analysis and experimental research were conducted to reveal how the eccentricity affects the effort of material in the joint area. The results of analysis and investigations are compared...
-
Ultimate strength of stiffened plates subjected to compressive load and spatially distributed mechanical properties
PublicationThe present study deals with the ultimate strength of stiffened plates subjected to spatially distributed mechanical properties and compressive load. Normally, mean values of mechanical properties based on tensile tests are used to validate the numerical assessment with experimental results. However, mechanical properties may vary within a single specimen. To investigate the impact of that, random fields of yield stress and Young...
-
Destruction of shell structures under the dynamic load on the human skull trauma basis
PublicationThe main aim of this work is to investigate patterns of potential orbital bone fractures due to mechanical injuries. The solution of the main problem is followed by analysis of several testing examples having straight correlation with civil engineering structures, in which materials of wide range of stiffness are applied. To solve the main problem, the three-dimensional finite element method (FEM) model of the orbital region has...
-
Model tests of cast-in-place piles formed by using different types of auger
PublicationModel tests are still a popular research tool used to observe and determine the mechanisms of pile-soil interaction. Due to the significant scale effect, the results of model tests performed in the 1g system can only be analysed from the qualitative side. This article describes and presents the results of 1g pile model tests carried out for comparative purposes. There were tested the effectiveness and efficiency of various types...
-
Preload monitoring in a bolted joint using Lamb wave energy
PublicationThe knowledge of the load in prestressed bolted connections is essential for the proper operation and safety of engineering structures. Recently, bolted joints have become an area of intensive research associated with non-destructive diagnostics, in particular in the context of wave propagation techniques. In this paper, a novel procedure of bolt load estimation based on the energy of Lamb wave signals was proposed. Experimental...
-
Impact and stretching standardized tests as useful tools for assessment of viscoelastic behavior for highly rubberized asphalt binder
PublicationAsphalt binder is generally identified as a brittle material at low service temperature or under high-speed load, and the brittleness becomes serious after weathering aging. Improving the toughness of asphalt binder through adding high-content of crumb tire rubber is an efficient method to solve this problem. Devulcanized rubber modified asphalt binder (DRMA) with different contents (15–40%) of devulcanized rubber (DR) were prepared...
-
Experimental Tests Of Sandwich Beams In The Design Process Of GFRP Shell Footbridge Structure
PublicationThe paper includes selected aspects of the study to elaborate architectural, material and construction design of pedestrian footbridge spans made of composite materials. The considered footbridge is a sandwich-type shell structure. The cooperation of PET foam core with outer lining surfaces is crucial for its load bearing capacity. The paper is aimed to experimental investigation of sandwich beams subjected to bending loading....
-
Corrugated Sheeting as a Member of a Shear Panel Under Repeated Load—Experimental Test
PublicationIn stressed-skin design, the cladding stiffening effect on structures is taken into account. However, the “traditional” design is more usual, wherein this effect is neglected. Even if the diaphragm actions are not regarded, in particular cases such as big sheds (and others), the parasitic (unwanted) stressed-skin action may occur with the result of leakage or even failure. The structures of this kind have already been built. Thus,...
-
INFLUENCE OF TIME ON THE BEARING CAPACITY OF PRECAST PILES
PublicationOne of the most popular types of foundations in layered subsoil with very differentiated soil shear strengths are precast piles. One of the reasons is a fact that we can well control the driving process during the installation of these piles. The principles of the assessment of bearing capacity and settlements of the piles given by Eurocode 7, concentrate on two main methods, i.e. Static Pile Load Tests (SPLT) and Dynamic Driving...
-
Prediction of Pile Shaft Capacity in Tension Based on Some Direct CPT Methods—Vistula Marshland Test Site
PublicationThis paper presents different CPT methodologies for the prediction of the pile shaft resistance in tension on the example of three reference screw piles of the Jazowa test site in Poland. The shaft capacity was estimated based on the cone resistance, sleeve friction and CPT excess pore water pressure. Three piles with diameter 0.4 m and the length varied from 8 m to 14.6 m were subjected to static load tests in tension. Their...
-
Developing a methodology for model tests of floating platforms in a towing tank of low depth
PublicationThe paper presents two ways to mooring model of semi-submersible platform for research in the small depth towing pool. The tested model was made in the likeness of 1:100 Thunder Horse platform moored in the Gulf of Mexico at a depth of 1,920 m. Its mooring system consisted of 16 semi-taut mooring lines (chain-wire-chain) spaced Star-shape and attached at the bottom to the suction piles. The tests were performed in the towing pool...
-
A Novel Coupling Matrix Synthesis Technique for Generalized Chebyshev Filters With Resonant Source–Load Connection
PublicationThis paper reports a novel synthesis method for microwave bandpass filters with resonant source–load connection. In effect, a network realizing N+1 transmission zeros (where N is the number of reflection zeros) is obtained. The method is based on a prototype transversal coupling matrix (N+2, N+2) with source and load connected by a resonant circuit formed by a capacitor in parallel with a frequency-invariant susceptance. To complement...
-
Dynamic Response of the Suspended on a Single Cable Footbridge
PublicationThe article presents numerical simulations, dynamic in situ load tests and a structural health monitoring (SHM) system installed in a suspended on a single cable footbridge. Numerical simulations performed prior to construction indicated the possibility of structural dynamics problems, finally confirmed in the course of dynamic test loading. In the dynamic load course the bridge deck developed vibrations displaying accelerations...
-
Implementation of failover and load balancing algorithms in SIP PBX High Availability system
PublicationGoal of the project was to design a High Availability SIP VoIP system that guarantees access to additional services like auto-attendent and automatic call distribution. The realization of the project required system to have load balancing and failover algorithms implemented. From the end users’ point of view the whole system had to figure as a single element. After taking under consideration the known methods of implementations...
-
Developing Methodology for Model Tests of Floating Platforms in Low -Depth Towing Tank
PublicationThe paper presents two different methods of physical modeling of semi-submersible platform mooring system for research in low depth towing tank. The tested model was made in the scale of 1:100 resembling the "Thunder Horse" platform moored in the Gulf of Mexico at a depth of 1,920 m. Its mooring system consisted of 16 semi-taut mooring lines (chain-wire-chain) spaced starshape and attached at the bottom to suction piles. The tests...
-
OPERATION OF TWO-SHAFT GAS TURBINE IN THE RANGE OF OPEN ANTI-SURGE VALVE
PublicationThis paper presents experimental tests of full-scale two-shaft gas turbine in the range of open anti-surge valve (ASV). The tests were carried out in a laboratory gas- turbine test stand belonging to Department of Automation and Power Engineering , Faculty of Ocean Engineering and Ship Technology , Gdańsk University of Technology. The tests covered the start-up and low load operation of the turbine set in the range of open...
-
Evaluation of Mechanical Properties of Two-Stage Concrete and Conventional Concrete Using Nondestructive Tests
PublicationDifferent types of concrete mixtures are used as building materials. The manufacturing process of two-stage concrete (TSC) differs from that of conventional concrete. This study investigated conventional mechanical properties derive empirical relations for estimation of the mechanical parameters of TSC and conventional concrete mixtures. TSC was used to prepare 216 specimens and conventional concrete was used to prepare 108 specimens...
-
Experimental and numerical study on deformed steel columns subjected to impact load during earthquakes
PublicationThe soft-storey failure is one of the most typical types of damage observed in buildings during earthquakes. The failure of an upper soft storey of a structure results in large impact load acting on the lower floors and if the resistance of the structural members of the lower storeys is not sufficient it may further lead to progressive collapse of the whole building. The aim of the present paper is to investigate the dynamic behaviour...
-
Laboratory Load Model Based on 150 kVA Power Frequency Converter and Simulink Real-Time – Concept, mplementation, Experiments
PublicationFirst section of the paper provides technical specification of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is presented. Theoretical considerations based on criteria which load types may be simulated using discussed laboratory setup, are described. As described model contains transformer with thyristor-controlled tap changer,...
-
CHARACTERIZATION STUDY ON MECHANICAL PROPERTIES OF POLYESTER COATED FABRIC
PublicationThe scope of the paper is to determine the mechanical properties of the Precontraint 1302 polyester coated fabric under uniaxial and biaxial tensile tests. The results are compared for Precontraint 1302 fabric and other types of coated fabrics. The author applied an orthotropic model and a dense net model to reflect the polyester coated fabric performance under uniaxial and biaxial tensile tests. Material parameters are specified...