Filters
total: 4767
-
Catalog
- Publications 3280 available results
- Journals 79 available results
- Conferences 1 available results
- Publishing Houses 1 available results
- People 249 available results
- Projects 3 available results
- Laboratories 1 available results
- e-Learning Courses 68 available results
- Events 1 available results
- Open Research Data 1084 available results
displaying 1000 best results Help
Search results for: electrical installations measurements
-
Blended Learning in Teaching Safety of Electrical Installations
PublicationBlended learning becomes more commonly used in teaching information technology or other subjects, which involve practice in computer laboratories. In case of subjects with no access to computer rooms blended learning supports lecturing and teaching classes e.g. interactive lessons. The article presents the use of blended learning forms in Gdansk University of Technology in teaching the subject of Safety of Electrical Installations....
-
Modern power-electronics installations in the Polish electrical power network
PublicationThe paper discusses the most important areas of application of power electronics arrangements in the Polish electrical power system; especially in the distribution system. The examples presented demonstrate both the need for and the purpose of further research and its applications in these fields, as well as indicating the direction of future research, with special consideration given to the research required in Poland. The proposed...
-
Application of residual current devices in electrical installations with frequency converters
PublicationW instalacjach elektrycznych, w których znajdują się przemienniki częstotliwości mogą pojawić się prądy zwarcia doziemnego o różnej częstotliwości lub stałe. Większość wyłączników różnicowoprądowych nie reaguje na tego typu prądy, co powoduje, że ochrona przeciwporażeniowa jest nieskuteczna. W obwodach z przemiennikami częstotliwości mogą pojawiać się przejściowe i ustalone prądy upływowe o znacznych wartościach. Prądy te znacząco...
-
Evaluation of fire hazard in electrical installations due to unfavorable ambient thermal conditions
PublicationEvaluation of fire hazard caused by electrical installations is a difficult and important topic, and it limits the possibility of loss of life or health of people, as well as the occurrence of significant property damage. In particular, this hazard was caused by power cables and especially photovoltaic (PV) installations. The authors proved that power cables directly exposed to strong solar radiation are likely to exceed maximum...
-
Evaluation of Fire Hazard in Electrical Installations Due to Unfavorable Ambient Thermal Conditions
Publication -
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublicationThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Protection against electric shock in electrical installations with low voltage generating sets
PublicationW referacie przedstawiono zasady ochrony przeciwporażeniowej, zgodne z wymaganiami międzynarodowymi, w sytuacji kiedy instalacja elektryczna jest zasilana z niskonapięciowych zespołów prądotwórczych. Zwrócono uwagę na dobór zabezpieczeń przeciwporażeniowych oraz na wymiarowanie uziemień.
-
Reassesing whole tooth electrical impedance spectroscopy measurements
PublicationW pracy dokonano krytycznej oceny wyników wcześniejszych badań spektorskopowych zębów przeprowadzonych w innych ośrodkach i porównano je z własnymi. Wskazano na trudności występujące podczas pomiarów.
-
Thermal Transitions in P3HT:PC60BM Films Based on Electrical Resistance Measurements
Publication -
Virtual Models of Analog-Digital Converters in Education of Electrical Measurements and Instrumentation.
PublicationPrzedstawiono opracowane przez autorów przyrządy wirtualne do demonstracji działania przetworników analogowo-cyfrowych: integracyjnego, kompensacyjnego, sigma-delta, z pośrednim sygnałem częstotliwościowym. Programy umożliwiają obserwację zmian napięcia w punktach charakterystycznych układów w spowolnionej skali czasowej. Możliwe jest również zadawanie zakłóceń.
-
Assessment of copper surface coverage with corrosion inhibitor using AFM-based local electrical measurements
PublicationThe paper presents a new method of assessment of metal surface coverage with corrosion inhibitor and thus of inhibitor protective performance. It is based on the atomic force microscopy measurement performed in a contact mode. Apart from topography images the proposed approach allows acquisition of local DC maps and local electrical impedance spectra via application of DC bias voltage or AC perturbation signal between the conductive...
-
Electrical measurements of the dewetting of metal thin films
Open Research DataIn situ observations of dewetting of thin films is very complicated. One of the method, that helps to observe it, could be electrical measurements. For experiments, thin gold, silver and gold-silver nanoalloy films were deposited by magnetron sputtering method. Films were deposited on a Corning glass substrates. Samples were measured by four point method...
-
Results of electrical voltage measurements in reactors - part 1
Open Research DataResults of electric voltage measurements in six reactors using various plantings. These are the results of the project: Integrated approach 3M (Macrophytes-Microbiome-Modelling) to elucidate mechanisms of bioenergy production and micropollutants transformation in Floating Treatment Wetlands combined with Microbial Fuel Cells.
-
Electrical conductivity relaxation measurements - water uptake of BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataFor Electrical Conductivity Relaxation (ECR) measurements, platinum reversible electrodes were applied in a four-probe arrangement and the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ sample was measured in the ProboStat™ measurement system. The ECR measurements were performed in air in the temperature range of 450-800 ℃ after switching water partial pressure between...
-
Electrical conductivity relaxation measurements - oxidation and reduction of BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataThe dataset consists of 2 main catalogs: measurements performed for oxidation/reduction in dry conditions and in humid conditions. For Electrical Conductivity Relaxation (ECR) measurements, platinum reversible electrodes were applied in a four-probe arrangement and the sample was measured in the ProboStat™ measurement system. The ECR measurements were...
-
D.C. electrical measurements of Bi2VO5.5 ceramic measured at high temperature region
Open Research DataD.C. electrical properties of Bi2VO5.5 ceramic was measured.
-
Electrical equipment and installations [2023/2024]
e-Learning Courses -
Electrical performance measurement of reference and SOFC with LSCNT layer fueled by H2 and 20ppm H2S/biogas mixture at 750 C - cyclic measurements (12h per cycle)
Open Research DataThe dataset contains the electrical IV measurements collected during the cyclic measurements of H2S poisoning in DIR-SOFC with/-out LSCNT layer. The H2S poisoning and H2 regenrating cycles were 12 h each. The spectra were collected every 10 min.
-
Time-current tripping characteristics of RCDs for sinusoidal testing current
PublicationLow-voltage electrical installations are verified initially – before being put into operation, as well as periodically – during their utilization. According to the IEC standards, the scope of the verification includes measurements of both the tripping current and the disconnection time of residual current devices (RCDs). Experiences in RCDs testing show that disconnection times of two or more similar RCDs can be quite different....
-
Tripping limitations of residual current devices in photovoltaic installations
PublicationIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...
-
Stanisław Galla dr inż.
PeopleStanisław Galla was born in 1970 in Gdańsk. He graduated from the Secondary Technical School of Mechanical and Electrical Engineering in Gdansk (1990). He studied at the Faculty of Electrical Engineering at Gdansk University of Technology (graduated in 1996). His PhD thesis entitled "Methodology for increasing the accuracy of low frequency measurements of periodic disturbance indicators in low voltage networks" was defended in...
-
Assessment of the factors influencing on the formation of energy-oriented modes of electric power consumption by water-drainage installations of the mines
PublicationPurpose. Performing the analysis to determine energy-efficient modes and assess the characteristics of the main indicators of electric power consumption by mine water-drainage installations based on the developed research mathematical model. Methods. To achieve the purpose set, a methodology is used to develop the multiple multifactor correlation-regression modeling with respect to the modes of electric power consumption by electrical...
-
Multifaceted Analyses of Four Different Prototype Lightweight Photovoltaic Modules of Novel Structure
PublicationDynamic growth of photovoltaic capacity in Poland encourages many entities to invest in photovoltaic systems. However, in the case of buildings with low roof-bearing capacity it can be problematic or even impossible to mount conventional PV modules due to their relatively high weight. Hence, the use of lightweight PV modules is a potential solution. In this paper four different prototype silicon lightweight modules of novel structure...
-
Leszek Jarzębowicz dr hab. inż.
PeopleLeszek Jarzebowicz received the M.Sc., Ph.D. and D.Sc. degrees from Gdansk University of Technology (GUT), Poland, in 2005, 2010 and 2019, respectively. His research areas include control and modeling of electric drives, diagnostics of railway vehicles, analysis of energy efficiency in electrified transport, and microprocessor implementation of control algorithms. His teaching interests focus on electric vehicles, electrical engineering...
-
PV installations and the safety of residential buildings
PublicationThe dynamic development of the photovoltaic industry entails threats that have a direct impact on the safety of residential buildings. Appropriate design of a PV installation can be a challenge due to the multifaceted nature of this issue. The designer should take into account issues related to the selection of electrical parameters of the installation, adapting lightning and surge protection in accordance...
-
Kazimierz Darowicki prof. dr hab. inż.
PeopleStudia wyższe ukończyłem w czerwcu 1981 roku po zdaniu egzaminu dyplomowego i obronie pracy magisterskiej. Opiekunem pracy magisterskiej był dr hab. inż. Tadeusz Szauer. W roku 1991, 27 listopada uzyskałem stopień naukowy broniąc pracę doktorską zatytułowaną „Symulacyjna i korelacyjna analiza widm immitancyjnych inhibitowanej reakcji elektrodowej”. Promotorem pracy był prof. dr hab. inż. Józef Kubicki (Wydział Chemiczny...
-
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublicationEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Behavior of residual current devices at earth fault currents with DC component
PublicationLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Technology and Energy Conversion Machines - Nowy
e-Learning CoursesThe course covers the basics of mechanical, electrical and thermal energy production in industry and maritime transport. Describes installations supporting high-power engines. Particular attention has been paid to the fuel systems of internal combustion engines. The treatment of engine exhaust gases is described.
-
Technology and Energy Conversion Machines - Nowy kopiuj 1
e-Learning CoursesThe course covers the basics of mechanical, electrical and thermal energy production in industry and maritime transport. Describes installations supporting high-power engines. Particular attention has been paid to the fuel systems of internal combustion engines. The treatment of engine exhaust gases is described.
-
Technology and Energy Conversion Machines
e-Learning CoursesThe course covers the basics of mechanical, electrical and thermal energy production in industry and maritime transport. Describes installations supporting high-power engines. Particular attention has been paid to the fuel systems of internal combustion engines. The treatment of engine exhaust gases is described.
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublicationResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Tripping of F-type RCDs for high-frequency residual currents
PublicationResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs are...
-
Tripping of F-type RCDs for High-Frequency Residual Currents
PublicationResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs...
-
RADIATION MEASUREMENTS
Journals -
Praktyka wykonywania pomiarów instalacji fotowoltaicznych prowadząca do określenia rzeczywistego stanu technicznego
PublicationPraca przedstawia zasady wykonywania pomiarów instalacji fotowoltaicznych wg normy PN-EN 62446-1. Proponowany w normie zakres podstawowy pozwala tylko na ocenę bezpieczeństwa pracy instalacji. Dopiero zakres dodatkowy umożliwia uzyskanie informacji o referencyjnych mocach zainstalowanej elektrowni, jej sprawności, a nawet jednorodności poszczególnych ogniw fotowoltaicznych. Załączone przykłady pomiarów czystych i zabrudzonych paneli...
-
The effect of current delay angle on tripping of residual current devices
PublicationPower electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....
-
Assessment of thermal and electrical performance of flat plate air-cooled photovoltaic roof tile – experimental and numerical studies
PublicationThe current state of development of the solar energy sector necessitates a new form of incentive for entities to invest in photovoltaic (PV) installations. Building-integrated photovoltaic/thermal (BIPV/T) systems are gaining increasing interest. Effective methods for heat recovery from BIPV/T collectors are searched for. Presented research experimentally and numerically considered the influence of cooling conditions on the electrical...
-
Profesor Stanisław Trzetrzewiński – polski prekursor niepewności pomiaru
PublicationArtykuł ma na celu przybliżenie sylwetki Profesora Stanisława Trzetrzewińskiego, jako pierwszego kierownika Katedry Miernictwa Elektrycznego na Wydziale Elektrycznym Politechniki Gdańskiej, odpowiedzialnego za organizację Katedry po wojnie, dydaktyka, ale przede wszystkim wybitnego metrologa. Profesora Stanisława Trzetrzewińskiego można nazwać polskim prekursorem teorii niepewności pomiaru, co potwierdza wygłoszony w 1952 roku...
-
The Possibility of Phase Change Materials (PCM) Usage to Increase Efficiency of the Photovoltaic Modules
PublicationSolar energy is widely available, free and inexhaustible. Furthermore this source of energy is the most friendly to the environment. For direct conversion of solar energy into useful forms like of electricity and thermal energy, respectively photovoltaic cells and solar collectors are being used. Forecast indicate that the first one solution will soon have a significant part in meeting the global energy demand. Therefore it is...
-
Badanie wybranych właściwości wyłączników różnicowoprądowych typu F
PublicationW instalacjach elektrycznych niskiego napięcia instaluje się coraz więcej przekształtników energoelektronicznych (systemy fotowoltaiczne, instalacje ładowania pojazdów elektrycznych, układy napędowe o regulowanej prędkości obrotowej silnika), a mają one wpływ na dobór typu wyzwalania wyłączników różnicowoprądowych (AC, A, F lub B). W obwodach, w których pojawia się prąd różnicowy zawierający składowe o częstotliwości innej niż...
-
NEW SOLUTIONS FOR THE SOLAR CHARGE CONTROLLERS DESIGN FOR OBTAINING TRUE MPP IN PARTLY SHADED PV MODULES
PublicationSoft shading sources such as tree limbs, structural elements of buildings and chimneys, scatter and refract sunlight, significantly reducing the amount of radiation reaching the surface of the module. The hard shadings located directly on the surface (i.e. bird droppings, leaves, snow) tend to stop sunlight completely. These phenomena significantly affects the output characteristics of photovoltaic modules and often contribute...
-
Biofouling UF car wash
Open Research DataPolyethersulfone (PES) membranes were used to separate wastewater from car washes containing bacteria.After the separation was completed, the UF installations were washed with chemical agents.The study examined how effectively these chemical agents remove bacterial contamination from the installation.P3 Ultrasil 11 alkaline solutions (pH = 12) were...
-
OCENA WŁAŚCIWOŚCI ROZLEGŁYCH SYSTEMÓW UZIEMIEŃ PRACUJĄCYCH W UKŁADACH OCHRONY ODGROMOWEJ
PublicationW wyniku połączenia wszystkich elementów uziemionych w obiekcie budowlanym do szyny ekwipotencjalnej powstaje często bardzo rozległy system uziemień. Ocena tak rozległego systemu za pomocą metod wykorzystujących przebiegi wolnozmienne prowadzi do zbyt optymistycznych wniosków odnośnie do ich właściwości podczas odprowadzania prądów wyładowań atmosferycznych. Pomiary z zastosowaniem metody wykorzystującej przebiegi impulsowe pomiaru...
-
Ocena systemów uziemień z wykorzystaniem pomiarów metodą udarową
PublicationW artykule zostały omówione procedury i wymagania stawiane systemom uziemień przez przepisy normalizacyjne z punktu widzenia ich skuteczności w systemie ochrony odgromowej. Podstawą tak sformułowanej oceny są pomiary z zastosowaniem metody udarowej. Metoda taka okazuje się bardzo przydatna zwłaszcza w przypadku uziemień rozległych, jakie pojawiają się we współczesnych obiektach wskutek połączenia różnych elementów uziemiających...
-
ASPEKTY BEZPIECZEŃSTWA W OCENIE WYNIKÓW POMIARÓW UZIEMIEŃ ODGROMOWYCH
PublicationOcena rozległego systemu za pomocą metod wykorzystujących przebiegi wolnozmienne prowadzi do zbyt optymistycznych wniosków odnośnie ich właściwości podczas odprowadzania prądów wyładowań atmosferycznych. Bardziej bezpieczne wnioski powstają w wyniku pomiarów z zastosowaniem metody wykorzystującej przebiegi impulsowe, ponieważ wtedy jest uwzględniana tylko ta część nawet bardzo rozległego systemu uziemień, która bierze udział w...
-
Oznaczanie tlenu – od metody Winklera do czujników enzymatycznych (Determination of oxygen – from Winkler Method to enzymatic sensor)
PublicationMonitoring of dioxygen levels is of utmost importance from the view-point of life processes, medical diagnostics, nutrition and chemical industries. In all these measurements both low and high levels of this element are important. The common methods for the determination of dioxygen are the Winkler method, Clark electrode and pulsoxymeters. A new, already strong field of research can be now recognized – the development of miniaturized...
-
Jarosław Guziński prof. dr hab. inż.
PeopleJaroslaw Guzinski received M.Sc., Ph.D. and D.Sc. degrees from the Electrical Engineering Department at Technical University of Gdansk, Poland in 1994, 2000 and 2011 respectively. Since 2016 he is Associate Professor at Gdansk University of Technology. Currently he is the head of the Department of Electric Drives and Energy Conversion. From 2006 to 2009 he was involved in European Commission Project PREMAID Marie Curie, ‘Predictive...
-
Residual current devices in installations with PV energy sources
PublicationThe paper presents the principles of residual current devices (RCDs) application in photovoltaic (PV) installations. Provisions of standards in this regard are commented on, in particular, attention is drawn to the lack of obligation to use of RCDs in PV installations. The issue of the shape of the earth fault current and the level of leakage currents in such installations are discussed. These factors influence the selection of...
-
Residual current devices in electric vehicles charging installations
PublicationThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...