Filters
total: 3036
displaying 1000 best results Help
Search results for: HIGHER-HARMONIC IMAGING
-
Optimizing of target detection and tracking processes realized on consoles of passive sonar with linear towed antenna
PublicationThe long-range passive towed sonar was first modernised a few years ago. Building on operator experience over that period, a concept was developed of optimising the tasks performed by sonar operators, and improving forms of imaging to inform about object detection and support object tracking. The concept was implemented and successfully tested during ships’ manoeuvres. The optimisation of operator tasks was designed to keep listening...
-
Liquid Crystals, PIV and IR-Photography in Selected Technical and Biomedical Applications
PublicationThermochromic liquid crystals (TLC), Particle Image Velocimetry (PIV), Infrared Imaging Themography (IR) and True-Colour Digital Image Processing (TDIP) have been successfully used in non-intrusive technical, industrial and biomedical studies and applications. These four tools (based on the desktop computers) have come together during the past two decades to produce a powerful advanced...
-
Strategy, effectiveness and quality of non-profit organisations as exempli-fied by Polish higher Education Institutions. VATT Governement Inst. Econ. Res. C**2002 [nr] 290 s. 189-202, 7 rys. bibliogr. 20 poz. Discussion papers. Workshopon Studies for Nordthern. Kalastajatorrpa,30-31 May 2002. Strategia, efektywność i jakość organizacji non-profit na przykładzie pol- skich wyższych uczelni.
PublicationW pracy wskazano, że do oceny jakości i efektywności organizacji niedochodo-wych zasadne jest wykorzystanie metod stosowanych w biznesie. W szczególno-ści zaproponowano zastosowanie metody balanced scorecard, benchmarkingu dooceny efektywności i jakości funkcjonowania instytucji szkolnictwa wyższego.Wskazano na możliwość wykorzystaniania analizy SWOT do opracowania strategiiuczelni.
-
Dual drive control under SVPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The analysis includes the behaviour of the drive system, examining the dynamic system response to speed and angle changes, and encompassing data...
-
The AFM micrographs of pitting corrosion evolution on high-alloy steel 1.4301
Open Research DataThe dataset contains the results of topographic imaging of high-alloy stainless steel 1.4301 on which the pitting corrosion process was induced by electrochemical methods. The study of the effects of a local attack allows for conclusions about the intensity and mechanism of this type of corrosion. The file contains atomic force microscopy (AFM) data...
-
XRD analysis of the tellurium dioxide thin films
Open Research DataTellurium dioxide thin films were deposited by magnetron sputtering method. The XRD analysis of the films annealed at 200, 500, 650 and 700 celsius degree showed appearing of crystalline phase in a higher temeratures.
-
Acoustic Streaming Induced by Periodic and Aperiodic Sound in a Bubbly Liquid
PublicationThe vortex ow which follows intense sound propagating in a bubbly liquid, is considered. The reasons for acoustic streaming are both nonlinearity and dispersion. That makes streaming especial as compared with that in a Newtonian uid. Conclusions concern the vortex ow induced in a half-space by initially harmonic or impulse Gaussian beam. The vortex ow recalls a turbulent ow with increasing in time number of small-scale vortices...
-
Fully Adaptive Savitzky-Golay Type Smoothers
PublicationThe problem of adaptive signal smoothing is consid-ered and solved using the weighted basis function approach. Inthe special case of polynomial basis and uniform weighting theproposed method reduces down to the celebrated Savitzky-Golaysmoother. Data adaptiveness is achieved via parallel estimation.It is shown that for the polynomial and harmonic bases andcosinusoidal weighting sequences, the competing signal estimatescan be computed...
-
Linear viscoelastic transversely isotropic model based on the spectral decomposition of elasticity tensors
PublicationThe linear viscoelasticity is still a useful model in the engineering for studying the behavior of materials loaded with different loading rates (frequencies). Certain types of materials reveal also an anisotropic behavior: fiber reinforced composites, asphalt concrete mixtures, or wood, to name a few. In general, researchers try to identify experimentally the dependence of engineering constants like: directional Young’s moduli...
-
An unorthodox view on the problem of tracking facial expressions
PublicationRecent developments in imaging cameras has opened a new way of analyzing facial expression. We would like to take advantage from this new technology and present a method of imaging and processing images of human face as a response to the particular stimuli. The response in this case is represented by the facial expressions and the stimuli are still images representing six basic emotions according to Eckmann. Working hypothesis...
-
An unorthodox view on the problem of tracking facial expressions
PublicationRecent developments in imaging cameras has opened a new way of analyzing facial expression. We would like to take advantage from this new technology and present a method of imaging and processing images of human face as a response to the particular stimuli. The response in this case is represented by the facial expressions and the stimuli are still images representing six basic emotions according to Eckmann. Working hypothesis...
-
Selection of material for X-ray tomography analysis and DEM simulations: comparison between granular materials of biological and non-biological origins
PublicationPhysical properties and X-ray tomography images of five different granular materials: glass bead, glass grit, short grain white rice, sorghum and clay granules (Seramis) are investigated to select the most promising materials for numerical simulations and time-lapse X-ray tomography imaging. The examined materials represent granular materials of non-biological origin (glass bead, glass grit and Seramis) and granular plant materials...
-
Deterioration of masonry structure investigated by a thermal camera with a qualitative assessment of thermal image processing
PublicationThermal imaging is contemporary remote sensing measurement technique, which provides an image of the temperature distribution in the measured object. The method is widely used, due to its mobility as well as the non-destructive character of the measurement. Infrared thermography is especially relevant in the inspection of insulation, what is more, it is a suitable device for detecting thermal bridges and structural changes, which...
-
EMBOA - affective loop in Socially Assistive Robotics as an intervention tool for children with autism
e-Learning CoursesThe aim of the training course "Intensive programmes for higher education learner" within the EMBOA project is to familiarise participants with the use of social robots as an intervention tool for children with autism, emotion recognition and the combination of both methods. Students will be informed about the guidelines and results of the project.
-
Wiktoria Wojnicz dr hab. inż.
PeopleDSc in Mechanics (in the field of Biomechanics) - Lodz Univeristy of Technology, 2019 PhD in Mechanics (in the field of Biomechanics) - Lodz Univeristy of Technology, 2009 (with distinction) List of papers (2009 - ) Wojnicz W., Wittbrodt E., Analysis of muscles' behaviour. Part I. The computational model of muscle. Acta of Bioengineering and Biomechanics, Vol. 11, No.4, 2009, p. 15-21 Wojnicz W., Wittbrodt E., Analysis of...
-
DALSA: Domain Adaptation for Supervised Learning From Sparsely Annotated MR Images
Publication -
Respiratory compensation point during incremental test in overweight and normoweight boys: is it useful in assessing aerobic performance? A longitudinal study
Publication -
Spatial Calibration of a Dual PTZ-Fixed Camera System for Tracking Moving Objects in Video
PublicationA dual camera setup is proposed, consisting of a fixed (stationary) camera and a pan-tilt-zoom (PTZ) camera, employed in an automatic video surveillance system. The PTZ camera is zoomed in on a selected point in the fixed camera view and it may automatically track a moving object. For this purpose, two camera spatial calibration procedures are proposed. The PTZ camera is calibrated in relation to the fixed camera image, using interpolated...
-
Theory versus experiment for vacuum Rabi oscillations in lossy cavities. II. Direct test of uniqueness of vacuum
PublicationThe paper continues the analysis of vacuum Rabi oscillations we started in part I [Phys. Rev. A 79, 033836 (2009)]. Here we concentrate on experimental consequences for cavity QED of two different classes of representations of harmonic-oscillator Lie algebras. The zero-temperature master equation, derived in part I for irreducible representations of the algebra, is reformulated in a reducible representation that models electromagnetic...
-
Propagation of Acoustic Disturbances in Shallow Sea
PublicationPropagation of acoustic waves in shallow sea differs fundamentally from the same phenomenon occurring in deep sea in view of non-negligible distance from the sea bottom in the first case, where presence of two regions limiting the water layer results in the acoustic pressure distribution induced by a harmonic source has an interferential nature as a result of multi-path propagation of the acoustic signal. These interferential properties...
-
Sensorless Predictive Multiscalar-Based Control of the Five-Phase IPMSM
PublicationThis article proposes multi-scalar variables based predictive control of sensorless multiphase interior permanent magnet synchronous machine. Estimated parameters from adaptive observers are used to implement the proposed control scheme. The control approach is divided into two parts: for the fundamental plane, torque and its dual quantity from the multi-scalar model are directly predicted by the controller, and torque density...
-
Comparative Analysis of Reactive Power Compensation Devices in a Real Electric Substation
PublicationA constant worldwide growing load stress over a power system compelled the practice of a reactive power injection to ensure an efficient power network. For this purpose, multiple technologies exist in the knowledge market out of which this paper emphasizes the usage of the flexible alternating current transmission system (FACTS) and presents a comparative study of the static var compensator (SVC) with the static synchronous compensator...
-
Mieczysław Brdyś prof. dr hab. inż.
People -
Wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego sterowanego ze sprzężeniem od prądu zasilającego
PublicationW artykule przedstawiono wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego i zdolność kompensacji prądów harmonicznych. Zbadano wpływ opóźnień czasowych wynikających z implementacji cyfrowej sterowania, wpływ impedancji zwarciowej sieci zasilającej oraz błędów generowania napięcia przekształtnika na jakość kompensacji filtru. Badania symulacyjne przeprowadzono dla trzech układów sterowania: otwartego, zamkniętego...
-
A filter bank solution for active power filter control algorithms
PublicationThb paper describes the proposed active power fiIter (APF) with a new control circuit based on an algorithm using ufilter bank and a harmonic predictor. The conirol circuit was realized using the digiiaI signor processor ADSP-21065L and FPGA circuiL In the proposed circuit transient performunee of APF is improved The active power fdter circuil has been built and teste6 and some illustrative, experimental results are uIso presented...
-
Electrical and noise responses of carbon nanotube networks enhanced by UV light for detection of organic gases (ethanol, acetone)
Open Research DataCarbon nanotube networks of different optical transparencies were investigated via resistance and 1/f noise measurements for detection of ethanol and acetone. The sensor resistive and noise responses were collected for dark and UV-assisted conditions, revealing the improvement in sensor sensitivity and limit of detection after applying UV light (275...
-
Monthly mean concentration of chlorophyll a on the sea surface of the Baltic Sea
Open Research DataMonthly mean surface concentration of chlorophyll a in the years 2003-2022 calculated on the basis of data from the SatBaltic System (https://satbaltyk.iopan.gda.pl/). Maps of monthly average values with a resolution of 1 km were derived from daily satellite data from the Moderate Resolution Imaging Spectroradiometer (MODIS). Gaps in satellite images...
-
The AFM micrographs of gold nanoparticles on silicon substrate
Open Research DataThe dataset contains the first approach towards AFM topographic imaging of gold nanoparticles synthesized and immobilized on the silicon surface. Measurements were made in the semi-contact mode on the NTEGRA Prima device, manufactured by NT-MDT. Scans were performed with amplitude detection at an operating value of 60% of the free oscillation amplitude....
-
The measurement of input power of power supply in network disturbed by low frequency distortions
PublicationIn the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed
-
New perspective on the in vivo use of cold stress dynamic thermography in integumental reconstruction with the use of skin-muscle flaps
PublicationAmong the problems encountered by plastic surgeons is the reconstruction of defects following tumors. One of the reconstructive options is TRAM flap. Despite that anatomy is well-explored, marginal flap necrosis may develop. To minimize complications imaging examinations was designed to determine the degree of flap perfusion. One of them is the thermographic examination.
-
Impact of Energy Slope Averaging Methods on Numerical Solution of 1D Steady Gradually Varied Flow
PublicationIn this paper, energy slope averaging in the one-dimensional steady gradually varied flow model is considered. For this purpose, different methods of averaging the energy slope between cross-sections are used. The most popular are arithmetic, geometric, harmonic and hydraulic means. However, from the formal viewpoint, the application of different averaging formulas results in different numerical integration formulas. This study...
-
Verification of the method of reconstructing convective velocity fields on the basis of temperature fields in vertical, differential and equally heated, open and closed channels
PublicationThis paper describes a method of reconstructing velocity fields, i.e. a numerical reconstruction procedure (NRP) that involves the numerical processing of experimentally measured temperature distributions in free convection heat transfer. The NRP consists in solving only the continuity and Navier–Stokes equations with an additional source term. This term is proportional to a known temperature (e.g. from a thermal imaging camera)...
-
Advanced polarization sensitive analysis in optical coherence tomography
PublicationThe optical coherence tomography (OCT) is an optical imaging method, which is widely applied in variety applications. This technology is used to cross-sectional or surface imaging with high resolution in non-contact and non-destructive way. OCT is very useful in medical applications like ophthalmology, dermatology or dentistry, as well as beyond biomedical fields like stress mapping in polymers or protective coatings defects detection....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #3The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #5.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #5.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,8 V at 241 mA. Sample 24, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,8 V and discharged to 10 mV by constant current 241 mA, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #2The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 250 mA. Sample 23, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 250 mA. Sample 23, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,8 V at 241 mA. Sample 24, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,8 V and discharged to 10 mV by constant current 241 mA, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,8 V at 241 mA. Sample 24, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,8 V and discharged to 10 mV by constant current 241 mA, experiment run #3.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,9 V at 241 mA. Sample 24, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,9 V and discharged to 10 mV by constant current 241 mA, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 250 mA. Sample 23, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 250 mA. Sample 23, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #4.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #4.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,9 V at 241 mA. Sample 24, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,9 V and discharged to 10 mV by constant current 241 mA, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 102 mA. Sample 51, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 102 mA. Experiment run #3. This experiment was preceded by experiment 10.34808/m9mn-yy02. The images were taken with thermographic camera VigoCAM V50....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,1 V at 561 mA. Sample 71, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,1 V and discharged to 10 mV by constant current 561 mA. Sample 71, experiment run #3.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #3. This experiment was preceded by experiment 10.34808/jf84-x137. The images were taken with thermographic camera VigoCAM V50....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,1 V at 561 mA. Sample 71, run #4.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,1 V and discharged to 10 mV by constant current 561 mA. Sample 71, experiment run #4.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #7.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #7. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...