Search results for: GENERATOR DUŻYCH MOCY
-
The distributed model predictive controller for the nuclear power plant turbo-generator set
PublicationTypically there are two main control loops with PI controllers operating at each turbo-generator set. In this paper a distributed model predictive controller DMPC, with local QDMC controllers for the turbine generator, is proposed instead of a typical PI controllers. The local QDMC controllers utilize step-response models for the controlled system components. These models parameters are determined based on the proposed black-box...
-
Pomiar efektywności wydatków budżetowych dużych miast w Polsce
PublicationArtykuł poświęcony jest pomiarowi efektywności wydatków ogółem. Podmiotem badania jest 37 miast na prawach powiatu zaliczanych do kategorii dużych, tzn. liczących od stu tysięcy do miliona mieszkańców. Horyzont czasowy analizy obejmuje lata 2009-2013. W badaniu zasto-sowano nieparametryczną metodę oceny efektywności względnej Data Envelopment Analysis (DEA). Jako nakład przyjęto wydatki budżetowe ogółem na mieszkańca, zaś rezultaty...
-
A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux
PublicationIn this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...
-
Przebudowa mostu kolejowego przez rzekę Pilicę z przystosowaniem do dużych prędkości
PublicationJednym z podstawowych założeń modernizacji polskich linii kolejowych jest przystosowanie ich do dużych prędkości ruchu (300 - 350 km/h). Wzrost prędkości ruchu powoduje zwiększenie efektów dynamicznych oddziaływania taboru na konstrukcję. Fakt ten niesie za sobą szereg dodatkowych wymagań stawianych nowym lub modernizowanym obiektom inżynierskim. W referacie przedstawiono proces projektowania i przebudowy mostu nad rzeką Pilicą,...
-
Prognozowanie mocy wytwórczej farmy wiatrowej
PublicationCelem pracy było opracowanie metody obliczeniowej oraz budowa narzędzia programowego do określenia produkcji mocy farmy wiatrowej na podstawie standardowej prognozy pogody z wyprzedzeniem jednej doby. W pracy przedstawiono rzeczywistą charakterystykę generacji mocy wytwórczej przemysłowych farm wiatrowych zależnej od zmiennych warunków wiatrowych. Analizując dane pomiarowe można znaleźć pewne zależności charakterystyczne. Wpływ...
-
Non-Adaptive Speed and Position Observer of Doubly-Fed Induction Generator
PublicationThe non-adaptive speed and position estimation of a doubly-fed induction generator (DFIG) is presented in this paper. The speed observer is based on the mathematical model of DFIG and to stabilize the structure the Lyapunov method is used. The classic stator field-oriented control to active and reactive power control is used in the sensorless control system. The performance of the proposed algorithm of a speed observer is validated...
-
Description logic based generator of data-centric applications
PublicationThe knowledge stored in Ontology Management Systems (OMS) that originally has the form of expressions, can be seen as a user application specification or as knowledge provided by an expert. The generator of applications discussed in this paper is defined as a program that automatically generates an application that meets a certain specification stored in OMS. It is shown that it is possible to build a user interface for data management...
-
Description logic based generator of data-centric applications
PublicationThe knowledge stored in Ontology Management Systems (OMS) that originally has the form of expressions, can be seen as a user application specification or as knowledge provided by an expert. The generator of applications discussed in this paper is defined as a program that automatically generates an application that meets a certain specification stored in OMS. It is shown that it is possible to build a user interface for data management...
-
Michał Michna dr hab. inż.
PeopleMichal Michna received the M.Sc. and Ph.D. degrees in electrical engineering from the Gdansk University of Technology (GUT), Gdansk, Poland, in 1998 and 2005, respectively. Since 2004, he was employed at the Department of Power Electronics and Electrical Machines of the Gdańsk University of Technology (assistant, assistant professor, senior lecturer). In 2010-2015 he was a deputy of head of the Department of Power Electronics and...
-
Skuteczne prognozowanie krótkoterminowe mocy farm wiatrowych
PublicationPrognozowanie mocy wytwórczej konkretnej farmy wiatrowej (FW) w horyzoncie 24-godzinnymwymaga zarówno wiarygodnej prognozy wietrzności, jak i narzędzi wspomagających. Narzędzie to jest dedykowanym modelem mocy farmy. Model powinien uwzględniać nie tylko ogólne zasady przetwarzania energii wiatru na energię mechaniczną, ale także cechy szczególnekonkretnej farmy. Liczba czynników wpływających na moc farmy jest duża i dokładna prognozamocy,...
-
Metody predykcji produkcji mocy parku wiatrowego
PublicationW związku z coraz to większą ilością zainstalowanych siłowni wiatrowych do Krajowej Sieci Elektroenergetycznej, brakiem stabilnej pracy generatorów wiatrowych zależnych od zmiennej prędkości wiatru, zakłady energetyczne wraz z Operatorem Sieci Przesyłowej PolskimiSieciami Elektroenergetycznymi S.A., nałożyły na właścicieli farmwiatrowych obowiązek prognozowania produkcji energii elektrycznej. Celem tego artykułu jest sprawdzenie...
-
Model fizykalny czy neuronowy? - Narzędzia do predykcji mocy wytwarzanej przez elektrownie wiatrowe
PublicationUstawowy obowiązek prognozowania mocyXVI Międzynarodowa Szkoła Komputerowego Wspomagania Projektowania, Wytwarzania i Eksploatacji, Jurata, 14-18 maja 2012 r. dotyczy właścicieli elektrowni wiatrowych o mocy znamionowej powyżej 50MW. Ze względu na coraz większą ilość przyłączonych elektrowni wiatrowych do krajowej sieci elektroenergetycznej, zapis ten może ulec zmianie, obejmując źródła wiatrowe mniejszej mocy. Obecnie największa...
-
Design of synchronous generator two inputs regulator based on hinf control theory.
PublicationThe power system is highly nonlinear system, its dynamics depends on system network configuration, system loading… etc. To overcome the above mentioned difficulties and fulfill the performance requirements the different control methods are considered and tested for design of synchronous generator control system. Application of the H optimization method to synchronous generator regulator based on measurement of generator voltage...
-
Logistyka techniczna HL modernizacji oraz transportu dużych urządzeń transportu bliskiego drogą morską
PublicationOmówiono procedurę wyposażenia w urządzenia dźwignicowe terminalu kontenerowego. Przedstawiono operację modernizacji kontenerowej suwnicy nabrzeżowej. Podano technologię transportu dużych suwnic kontenerowych drogą morską.
-
Analiza silnika piezoelektrycznego małej mocy
PublicationZaprezentowano główne metody modelowania dwóch podstawowych typów silników piezoelektrycznych małej mocy: silników tarciowych oraz beztarciowych. Zostały zaprezentowane przykładowe elektrochemiczne schematy zastępcze tych typów silników. Przeprowadzono również analizę i dyskusję zasad modelowania i własności nowego typu silnika.
-
Power System Stabilizer as a Part of a Generator MPC Adaptive Predictive Control System
PublicationIn this paper, a model predictive controller based on a generator model for prediction purposes is proposed to replace a standard generator controller with a stabilizer of a power system. Such a local controller utilizes an input-output model of the system taking into consideration not only a generator voltage Ug but also an additional, auxiliary signal (e.g., α, Pg, or ωg). This additional piece of information allows for taking...
-
Axial-Flux Permanent-Magnet Dual-Rotor Generator for a Counter-Rotating Wind Turbine
PublicationCoaxial counter-rotating propellers have been widely applied in ships and helicopters for improving the propulsion efficiency and offsetting system reactive torques. Lately, the counter-rotating concept has been introduced into the wind turbine design. Distributed wind power generation systems often require a novel approach in generator design. In this paper, prototype development of axial-flux generator with a counter-rotating...
-
Analiza warunków pracy obciążenia wzorcowego dużej mocy.
PublicationOmówiono krótko rozwój reflektrometrów mikrofalowych oraz zasadę pracy i konstrukcję reflektrometrów pracujących z dużymi poziomami mocy. Przeanalizowano wpływ wartości modułu współczynnika odbicia obciążenia wzorcowego,które jest stosowane w procedurze kalibracyjnej reflektometrów, na dokładność reflektometrycznych pomiarów niedopasowania impedancyjnego oraz istotnych w badaniach procesów grzania mikrofalowego pomiarów...
-
FIReWORK: FIR Filters Hardware Structures Auto-Generator
PublicationThe paper presents application called FIReWORK, that allows for automatic creation of the VHDL hardware structures of FIR filters. Automat- ically generated specialized hardware solutions dedicated to the FPGA and ASIC are commonly known as Intellectual Property Cores. The essential fu- ture of the application is easy initialization of FIR filter parameters in GUI, and then automatically design, calculate and generate the IP Core...
-
Feedback Control of Doubly-Fed Generator Connected to Current Source Converter
PublicationDoubly-fed induction generator (DFIG) system supplied by current source converter (CSC) is considered in this article. The DFIG can work in two independent modes: AC grid connection and stand-alone mode. The DFIG is connected to the ac grid directly through its stator and the CSC links the rotor side. In this mode, the active and reactive powers of the DFIG must be controlled. This article proposes two control system structures...
-
Nonlinear Model of Synchronous Generator for Autonomous Electrical Power Systems Analysis
PublicationThis paper presents the nonlinear lookup table model for synchronous generator (SG) analysis. The saturation effects of the SG magnetic circuit have been considered. The saturated characteristic of the SG magnetic circuit are based on the open circuit saturation curve for magnetizing inductances. The model has been implemented into the Synopsys/Saber software using the MAST modelling language. To implement the no-load voltage characteristic...
-
Comparative Study of Integer and Non-Integer Order Models of Synchronous Generator
PublicationThis article presents a comparison between integer and non-integer order modelling of a synchronous generator, in the frequency domain as well as in the time domain. The classical integer order model was compared to one containing half -order systems. The half-order systems are represented in a Park d-q axis equivalent circuit as impedances modelled by half-order transmittances. Using a direct method based on the approximation...
-
Fault-tolerant performance of the novel five-phase doubly-fed induction generator
PublicationThe article presents the concept of a new design of a multi-phase doubly-fed induction generator (DFIG). The innovative design approach uses a five-phase power supply from the rotor side of the generator with a three-phase classic stator power supply. Modern three-phase doubly-fed induction generators are the dominant choice for Wind Energy Conversion Systems (WECS). Solutions of this type are sensitive to the loss of at least...
-
Ocena charakterystyki mocy parku wiatrowego
PublicationPrognozowanie mocy parków wiatrowych nie należy do łatwych przedsięwzięć, nie tylko ze względu na stochastyczny charakter wymuszenia jakim jest wiatr, ale wiele innych czynników mających wpływ na wartość prognozy. W artykule przedstawiono główne czynniki wpływające na moc parku wiatrowego: prędkość wiatru, kierunek wiatru, pionowy profil wiatru, przesłonięcie oraz dynamika zmian wiatru. Rozważania poparto na wynikach pomiarów.
-
UKŁAD REGULACJI MOCY DUŻEJ FARMY FOTOWOLTAICZNEJ
PublicationW dniu 17 maja 2016 r. weszło w życie Rozporządzenie Komisji (UE) 2016/631 z dnia 14 kwietnia 2016 r. ustanawiające kodeks sieci dotyczący przyłączenia jednostek wytwórczych [3]. Na podstawie tego dokumentu i Prawa Energetycznego OSP i OSD przygotowało wymogi w zakresie przyłączania jednostek wytwórczych do sieci energetycznej. Moduły wytwarzania B, C i D powinny posiadać możliwość regulacji mocy czynnej i biernej. Niniejszy artykuł...
-
Technical evaluation of marine auxiliary diesel engine on the basis of parameters synchronous generator
PublicationThe article presents a method for evaluating the technical condition of selected structural elements of the reciprocating internal combustion engine driving a synchronous generator. Th results of measurements of the electric generator parameters are the diagnostic information source. On this basis it is possible to determine the instantaneous angular speed marine engine crankshaft which, in turn, is the basis for reasoning about...
-
Układy sterowania silnika piezoelektrycznego małej mocy.
PublicationW artykule zaprezentowano główne metody zasilania, sterowania i kontroli silników piezoelektrycznych małej mocy. Zaprezentowano nowy system zasilania i sterowania. Przeanalizowano również schemat badań laboratoryjnych.
-
Voltage and frequency regulation of a standalone induction generator by reduced-rating power electronic compensators - comparative evaluation
PublicationIn this paper are considered two fundamental topologies of power electronic compensators for voltage and frequency control of a standalone self-excited induction generator (IG) system. These are voltage and current source inverter based shunt compensators with energy storage. The aim of this study is to assess main features of both topologies in dynamic and steady-state IG operation. The whole system is modelled with the aid of...
-
Non-Salient Brushless Synchronous Generator Main Exciter Design for More Electric Aircraft
PublicationThis paper presents a prototype of high speed brushless synchronous generators (BSG) design for the application in autonomous electric power generation systems (e.g., airplane power grid). Commonly used salient pole field of the main generator part of BSG was replaced with a prototype non-salient pole field. The main objective of the research is an investigation into the advantages and disadvantages of a cylindrical field of the...
-
Analiza mocy chwilowej do celów diagnostyki łożysk.
PublicationW artykule przedstawiono tematykę dotyczącą diagnostyki łożysk przy wykorzystaniu metody badawczej, opartej na pomiarze i analizie sygnału mocy chwilowej pobieranej przez silnik indukcyjny. Zaprezentowano przykładowe wyniki wykonanych pomiarów w oparciu o zaproponowaną metodę. Na podstawie przeprowadzonej analizy sformułowano wnioski dotyczące możliwości wykorzystania sygnału mocy chwilowej jako symptomu diagnostycznego, przeznaczonego...
-
Ochrona odgromowa dużych obiektów sportowych na przykładzie stadionu PGE ARENA w Gdańsku
PublicationW artykule przedstawiono specyfikę ochrony dużych obiektów sportowych przed skutkami wyładowań atmosferycznych. Omówiono zasady ochrony tych obiektów przed bezpośrednim uderzeniem pioruna oraz sposoby ograniczenia przepięć powstających w instalacjach elektroenergetycznych oraz sterujących i pomiarowych zainstalowanych w takich obiektach. Wskazano konieczność indywidualnego rozwiązywania systemów ochronnych.
-
Wolnoobrotowy generator z magnesami trwałymi do elektrowni wiatrowej z turbiną o pionowej osi obrotu
PublicationW artykule przedstawiono założenia projektowe, wybrane wyniki etapu projektowania i badania prototypu wolnoobrotowego generatora z magnesami trwałymi współpracującego z elektrownią wiatrową z innowacyjną turbiną o pionowej osi obrotu. Projekt został wykonany na zlecenie firmy ALU ECO Sp. z o.o. z Gdańska w ramach projektu badawczorozwojowego Pionowa Turbina Wiatrowa, współfinansowanego przez Polską Agencję Rozwoju Przedsiębiorczości...
-
Adaptacyjny regulator transformatora blokowego = Adaptive controller of generator transformer
PublicationW referacie przedstawiono koncepcję adaptacyjnego regulatora transformatora blokowego jako narzędzia do rozszerzenia ograniczeń generacji mocy biernej generatora synchronicznego.
-
Sensorless Rotor Position Estimation of Doubly-Fed Induction Generator Based on Backstepping Technique
PublicationThis paper proposes a speed observer algorithm for the sensorless control of a doubly-fed induction generator based on classical adaptive backstepping technique. The sensorless control is shown using classic stator field oriented control which is used to active and reactive power control. Performance of the proposed algorithm of a speed observer is validated by simulation and experimental results obtained using a small-rating generator...
-
ROZPRZESTRZENIANIE SIĘ SKUTKÓW DUŻYCH KATASTROF KOLEJOWYCH
PublicationPrzy ciągle rosnącej wielkości kolejowych przewozów towarowych z udziałem materiałów niebezpiecznych, coraz większego znaczenia nabiera bezpieczeństwo tych przewozów. W przypadku katastrofy należy minimalizować jej skutki. Jest to możliwe tylko wtedy, gdy zostanie rozpoznany mechanizm rozprzestrzeniania się skutków katastrofy z udziałem materiałów niebezpiecznych. Pomocne tu jest modelowanie tych zjawisk.
-
Analysis of Organic Rankine Cycle efficiency and vapor generator heat transfer surface in function of the reduced pressure
PublicationIn the paper presented is analysis of the influence of reduced pressure on efficiency and heat transfer area of vapor generator of Organic Rankine Cycle (ORC) in case of subcritical and supercritical parameters of operation. Compared are two cases of subcritical and supercritical ORC featuring a similar arrangement of heat source supply and heat removal, that is featuring the same temperatures of working fluid before the turbine,...
-
Kogeneracja gazowa vs rynek mocy w Polsce
Publicationprzedstawiono prolemy rozwoju kogenerfacji gazowej w Polsce w aspekcie tworzonego rynku mocy.
-
Low speed permanent magnet synchronous generator for vertical axis wind turbine
PublicationThe paper presents design process and tests of a prototype low speed permanent magnet synchronous generator (PMSG) dedicated for the innovative vertical-axis wind turbine. The rated data of the designed generator are following: power - 15 kVA, voltage - 400 V (Y), rotation speed - 93.75 rpm. The design assumptions, chosen results of the design process and experimental tests of the prototype PMSG are presented. The considered PMSG...
-
Przegląd metod monitorowania stanu technicznego tranzystorów mocy
PublicationW artykule przedstawiono kilka metod monitorowania stanu technicznego tranzystorów mocy, które są lub mogą być wbudowane w układy przekształtnikowe. Celem artykułu jest określenie aktualnego stanu badań na ten temat. Prezentowane metody przeznaczone są do monitorowania istotnych objawów starzenia modułów mocy: rozwarstwiania struktury modułu na skutek termomechanicznego zmęczenia stopu lutowniczego, uszkodzeń połączeń drutowych...
-
Przegląd metod monitorowania stanu technicznego tranzystorów mocy
PublicationW artykule przedstawiono kilka metod monitorowania stanu technicznego tranzystorów mocy, które są lub mogą być wbudowane w układy przekształtnikowe. Celem artykułu jest określenie aktualnego stanu badań na ten temat. Prezentowane metody przeznaczone są do monitorowania istotnych objawów starzenia modułów mocy: rozwarstwiania struktury modułu na skutek termomechanicznego zmęczenia stopu lutowniczego, uszkodzeń połączeń drutowych...
-
Winding function approach based design of novel five-phase brushless doubly fed induction generator
PublicationThe paper presents the concept of the new design of the five-phase brushless doubly fed induction generator. The generator is dedicated to the modern wind turbine. The innovative design approach uses a five-phase power supply from the stator control winding side of the generator with a stator three-phase classic power winding. The research results presented indicate that the electromagnetic coupling between the control and power...
-
Wykrywanie sygnałów z widmem rozproszonym o małej mocy
PublicationNiniejszy artykuł podzielony został na trzy części. Pierwsza z nich zawiera opis koncepcji oraz schemat blokowy stanowiska do wykrywania sygnałów z widmem rozproszonym o małej mocy. Ponadto, w tej części jest zaprezentowana realizacja praktyczna takiego stanowiska. Część druga jest charakterystyką oprogramowania, realizującego cyfrowe przetwarzanie sygnałów i stanowiącego interfejs użytkownika dla operatora stanowiska. W ostatniej...
-
Algorytmiczne metody redukcji poboru mocy w układach CMOS
PublicationW pracy przedstawiono wybrane możliwości zredukowania poboru mocy układów CMOS z wykorzystaniem dwóch algorytmów szeregowania zadań w procesie syntezy wysokiego poziomu układów cyfrowych. Zaprezentowano dwa opracowane algorytmy, a mianowicie MAREL i UNILO, dla których utworzono odpowiednie programy pozwalające uzyskać redukcję mocy projektowanych układów CMOS. Przeprowadzone badania testowe przy pomocy standardowych benchmarków...
-
Temperature measurements in monitoring of large thrust bearings
PublicationW pracy przedstwiono krytyczną analizę aktualnych metod diagnostyki dużych hydrodnamicznych łożysk wzdłużnych hydrozespołów elektrowni wodnych. Wykazano niedostatki i zagrożenia płynące ze stosowania diagnostyki opartej na jednopunktowym pomiarze temperatury. Zaprezentowano wstępna koncepcję nowej metody diagnostycznej opartej na odwrotnym zagadnieniu przepływu ciepła (IPHC).
-
Sterowanie poziomami napięć i rozpływem mocy biernej w lokalnych elektrowniach z generatorami synchronicznymi.
PublicationW krajowym systemie elektoenergetycznym możliwości regulacyjne lokalnych elektrowni w zakresie sterowania poziomami napięć i rozpływem mocy biernej dotychczas wykorzystywane są mało. Przyczyną jest brak odpowiednich systemów rozliczeń i nieprzystosowanie układów regulacyjnych. Opisano możliwe cele takiej regulacji oraz zaprezentowano niektóre sposoby potrzebnego rozwoju układów regulacyjnych elektrowni lokalnych. W szczególności...
-
Experimental and numerical analysis of streamwise vortex generator for subsonic flow
PublicationW pracy przedstawiono porównanie wyników obliczeń numerycznych dwoma kodami (FLUENT i SPARC) na tle badań eksperymentalnych generatora wirów wzdłużnych. Przedstawiono wyniki dla liczb Macha przepływu głównego 0.3 i 0.8. Porównano ciśnienie całkowite w dwóch przekrojach za otworem przez który realizowany jest wydmuch. Przedstawiono strukturę wiru wzdłużnego uzyskaną dla obu programów. Średnica otworu jetu jest równa 1mm, co odpowiada...
-
Bezczujnikowe sterowanie trakcyjnym silnikiem IPMSM małej mocy
PublicationW referacie przedstawiono bezczujnikowy napęd trakcyjny wykorzystujący silnik synchroniczny z magnesami trwałymi zagłębionymi w wirniku (IPMSM). Zaprezentowano ogólną strukturę układu regulacji momentu silnika. Omówiono estymatory położenia kątowego wirnika dla małych i dużych prędkości kątowych. Opisano laboratoryjne stanowisko badawcze. Przedstawiono wybrane wyniki eksperymentalne z bezczujnikowej pracy napędu.
-
Porównanie mocy strat energetycznych w pompie wyporowej o zmiennej wydajności określonych bez uwzględnienia bądź z uwzględnieniem mocy ściskania oleju hydraulicznego
PublicationPorównano moce strat energetycznych w pompie wyporowej o zmiennej wydajności, określone bez uwzględnienia bądź z uwzględnieniem mocy ściskania oleju hydraulicznego. Ocena mocy ściskania cieczy w pompie stała się możliwa dzięki zastosowaniu, zaproponowanej przez autora, metody określenia stopnia zapowietrzenia cieczy w pompie. W metodzie określenia stopnia zapowietrzenia cieczy w pompie oraz w ocenie mocy strat objętościowych ściskania...
-
Experimental investigations and simulations of the microturbine unit with permanent magnet generator
PublicationIn dispersed power generation, low power devices are used for local combined generating of heat end electric power. There are developing concepts of micropower plants with electric generators driven by steam or gas microturbines. The paper presents the results of an experimental investigations of the microturbine set consists of the turbine with partial admission, permanent magnet generator and three phase AC-to-DC rectifier. The...
-
Reaktory jądrowe małej i średniej mocy
PublicationOstatnie lata przyniosły wzrost zainteresowaniareaktorami jądrowymi małej i średniej mocy (SMR - ang.Small and Medium Reactors), których moce nie przekraczają700 MW, jako rozwiązania alternatywnego dladużych skomercjalizowanych bloków jądrowych. Obecnierozwijane reaktory małych i średnich mocy mogą konkurowaćz dużymi reaktorami z uwagi na zalety w postaci:1) mniejszej konstrukcji pozwalającej na produkcjęelementów reaktora w nadzorowanych...