displaying 1000 best results Help
Search results for: PASSIVE EARTH PRESSURE
-
Experimental investigation on straight and u-bend double tube heat exchanger with active and passive enhancement methods
PublicationAuthors in this work want to demonstrate the possibility to increase the heat transfer efficiency by using simple wire coil inserts to create turbulent flow in the boundary layer as well as air blowing into the annulus of the pipe. In the study, Wilson plot approach was applied in order to estimate heat transfer coefficients for all heat exchanger (HX) configurations. The study focuses on experimental values of heat transfer coefficient...
-
Application of passive sampling techniques as a usable tool in the field of environmental quality monitoring
PublicationAnalysis of literature data published for the past 20 years leads to the conclusion, that passive sampling technique has been developing very quickly and is commonly used in the field of monitoring pollutants in air, water and soil environment. The popularity of application of passive sampling techniques in analytical and environmental chemistry results from its many advantages e.g.: Simplicity in use, low costs of exploitation,...
-
Miniaturized Passive Emission Chambers for In Situ Measurement of Emissions of Volatile Organic Compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air. The presence of dangerous chemical compounds in indoor air can have an adverse impact on human health and cause numerous diseases of the respiratory and circulatory systems. Such harmful chemicals get into indoor air as a result of their emission from building and indoor materials....
-
Optical properties of TeOx gels doped with a mix of rare-earth ions
Open Research DataThe DataSet contains the UV-Vis spectra of the TeOx gels doped with a mix of rare-earth ions. The material was obtained by the sol-gel method. The starting solution was prepared by mixing telluric acid (precursor) with thetraetylene glycol, water, and ethanol. Next, the different molar concentration of rare-earth ions was added, nitrates were used...
-
Miniaturized passive emission test chamber for in-situ measurement of emissions of organic compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air (outdoor). One of the main groups of chemical compounds present in indoor air, with proven harmfulness to health,are volatile organic compounds (VOCs). VOCs present indoor comprise a wide variety of hydrocarbons and hydrocarbons derivatives including aliphatic, aromatics, alkylbenzens,...
-
Buck-Boost Inverters with Symmetrical Passive Four-terminal Networks
PublicationAlternating Voltage Inverters (Converters) supplied by low-voltage sources DC (ex. fuel cell, photovoltaic cell) are most frequently realized on the basis of the three fundamental topologies: a) PWM voltage inverter with boost-converter" system, b) PWM voltage inverter with transformed converter DC/DC in the ,,boost-converter" system, c) PWM current converter. However none of these solutions is claimed to be the best and dominant...
-
Cheap Cancellation of Strong Echoes for Digital Passive and Noise Radars
PublicationThe problem of cancellation of strong, potentially nonstationary,echoes in noise radars and passive radars utilizing digitaltransmissions is considered. The proposed solution is a multi-stage procedure.Initial clutter estimates, obtained using the least mean squares(LMS) algorithm, are refined using specially designed filters, "matched"to spectral densities of targets and clutter. When the postprocessing filtersare noncausal, the...
-
New Alternative Passive Networks to Improve the Range Output Voltage Regulation of the PWM Inverters
PublicationThis paper presents different topologies of buck-boost converters with passive input networks that have alternative topologies; this is known in the literature as a Z-source inverter. Alternative passive networks were named by the authors as T-inverters; these improve output voltage regulation of the PWM inverters. T-inverter has fewer reactive components in comparison to conventional Z-source inverter. The most significant advantage...
-
Selected problems of earth fault loop impedance testing in circuits fed from UPS
PublicationIn the paper a principle of earth fault loop impedance testing in low voltage systems has been presented. Selected factors, influencing accuracy of the testing, are indicated. A structure of UPS of VFI-type and the problem of impedance testing in circuits with such type of UPS are discussed.
-
BLOOD PRESSURE MONITORING
Journals -
Electrolyte and Blood Pressure
Journals -
HIGH PRESSURE RESEARCH
Journals -
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Rehabilitation device supporting active and passive upper limb exercises
PublicationThis article presents a mechatronic solution for rehabilitation devices supporting active and passive exercises in persons with motor dysfunctions of the upper limbs in the area of the elbow and shoulder joints. A planar positioner integrated with original software and a control system, served as the basis for creating the present solution. Bellman’s programming method was applied to optimize the motion trajectory of the planar...
-
Determination of Volatile Organic Compounds in Indoor Air in the Gdansk Area Using Permeation Passive Samplers
PublicationPassive dosimetry — known for over a hundred years — is still a useful tool in monitoring air pollutants. In this work, permeation passive samplers were used to determine indoor air quality in 22 apartments located in the Gdansk area in the northern part of Poland. The results obtained by the passive sampling technique were compared to those obtained by dynamic sampling. Attempts were also made to identify indoor sources of...
-
Anisotropy and compaction gradient assessment on rammed earth specimens through sonic tomography approach
PublicationRammed earth is a traditional construction technique that has recently gained attention because of its benefits from an ecological perspective. The conservation of the existing valuable cultural heritage sites and the quality control of new constructions built with this material require the development and application of practical inspection techniques. This paper explores the application of sonic tests and sonic tomography as...
-
Apparent molar volumes and compressibilities of alkaline earth metal ions in methanol and dimethylsulfoxide
PublicationTemperature dependencies of density of magnesium (II), calcium (II), strontium (II), barium (II) perchlorates as well as beryllium (II), and sodium trifluoromethanesulfonates in methanol and dimethylsulfoxide have been determined over the composition range studied. From density data the apparent molar volumes and partial molar volumes of the salts at infinite dilution as well as the expansibilities have been evaluated. The apparent...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Zero-Pole Approach in Microwave Passive Circuit Design
PublicationIn this thesis, optimization strategies for design of microwave passive structures including filters, couplers, antenna and impedance transformer and construction of various surroogate models utilized to fasten the design proces have been discussed. Direct and hybrid optimization methodologies including space mapping and multilevel algorithms combined with various surrogate models at different levels of fidelity have been utilized...
-
Planning a Cost-Effective Delay-Constrained Passive Optical Network for 5G Fronthaul
PublicationWith the rapid growth in the telecommunications industry moving towards 5G and beyond (5GB) and the emergence of data-hungry and time-sensitive applications, Mobile Network Operators (MNOs) are faced with a considerable challenge to keep up with these new demands. Cloud radio access network (CRAN) has emerged as a cost-effective architecture that improves 5GB performance. The fronthaul segment of the CRAN necessitates a high-capacity...
-
Earth
Journals -
GeoPlanet: Earth and Planetary Sciences
Journals -
Treatment of high blood pressure in elderly and octogenarians: European Society of Hypertension statement on blood pressure targets
Publication -
Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives
PublicationThis paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...
-
Application of galvanodynamic impedance spectroscopy for studying passive film cracking under mechanical strain
PublicationThe paper reports the results of simultaneous mechanical and electrochemical investigations on austenitic (18/8) stainless steel in a 2 % solution of sulphuric acid. The measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Electrochemical analysis of mechanical passive layer cracking and repassivation conditions during a tensile test was carried out. Application of this methodology allowed...
-
Computer System for Evaluation of Shock Hazard in Circuits with Non-sinusoidal Earth Currents
PublicationEffects of current on people are mainly considered for 50/60 Hz sinusoidal current and smooth direct current. However, modern low voltage circuits are very often equipped with power electronics converters – rectifiers, frequency converters, therefore non-sinusoidal earth currents (touch currents) occur. For non-sinusoidal currents safety criteria should be modified. This paper presents a computer system, based on LabVIEW environment,...
-
Journal of Active and Passive Electronic Devices
Journals -
Pressure Pulsations in Turbine Blade Seal
PublicationThe paper presents the results of experimental investigations into pressure forces generated in a turbine labyrinth seal. The experiments were performed on a single-stage air model turbine of the impulse type. The performed experimental research proved that in a shroud clearance the pressure pulsates and the effects of the nozzle trailing edge thickness as well as the influence of the rotor blades are observed. The exemplary results...
-
Automatic localization and continous tracking of mobile sound source using passive acoustic radar
PublicationA concept, practical realization and applications of the passive acoustic radar for localization and continuous tracking of fixed and mobile sound sources such as: cars, trucks, aircrafts and sources of shooting, explosions were presented in the paper. The device consists of the new kind of multi-channel miniature three dimensional sound intensity sensors invented by the Microflown company and a group of digital signal processing...
-
Experimental Designs of Mass Customized Passive Single-family Houses - Prospects and Limitations
PublicationAbstract The article deals with case studies of selected architectural designs of the past fifteen years the authors of which intended to rethink both the typology and the means of constructing single family houses. The analysis covers contemporary design issues such as variation, curvilinearity, customization, digital manufacturing and ecological concerns. The purpose behind the research was to establish in what way new design...
-
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublicationThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...
-
Application of the chromatographic retention index system for the estimation of the calibration constants of permeation passive samplers with polydimethylsiloxane membranes
PublicationThe paper presents the results of research on the calibration of permeation passive samplers equipped with polydimethylsiloxane (PDMS) membranes using the physico-chemical properties of the analytes. Strong correlations were found between the calibration constants of the samplers and the linear temperature-programmed retention indices of the analytes determined on columns coated with pure PDMS (r2 = 0.914). These correlations...
-
THE SYNCHROSQUEEZING METHOD IN BEARING ESTIMATION OF STATIONARY SIGNALS FOR PASSIVE SONAR WITH TOWED ARRAY
PublicationIn this paper, a novel method of bearing estimation in a passive sonar system with a towed array is introduced. The classical approach of bearing estimation based on the spatial spectrum [1] is extended by using the synchrosqeezing method that is a part of the reassignment method introduced by Kodera et al. [2]. Using this method leads to a precise bearing estimation. The proposed method requires a relatively small amount of computation,...
-
Expedited Optimization of Passive Microwave Devices Using Gradient Search and Principal Directions
PublicationOver the recent years, utilization of numerical optimization techniques has become ubiquitous in the design of high-frequency systems, including microwave passive components. The primary reason is that the circuits become increasingly complex to meet ever growing performance demands concerning their electrical performance, additional functionalities, as well as miniaturization. Nonetheless, as reliable evaluation of microwave device...
-
Pounding mitigation of a short-span cable-stayed bridge using a new hybrid passive control system
PublicationThis paper investigates the effectiveness of a new hybrid passive control system on the seismic response of an existing steel cable-stayed bridge considering the pounding effect. The proposed hybrid passive control system comprises a seismic isolator and a metallic damper. The bridge is located in a high seismic zone and has suffered several damages including the earthquake-induced pounding damage during the 1988 earthquake....
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
PROPERTIES OF DOPED ALKALINE-EARTH STANNATES
PublicationThe lanthanum doped barium stannate properties are investigated in this work. Including electrical and microstructural properties.
-
The external walls of a passive building: A classification anddescription of their thermal and optical properties
PublicationThis paper attempts a new classification of insulating materials from the perspective of their utility in thepro-ecological passive construction industry. The main criterion is the conductivity of thermal and solarenergy. Based on their ability to conduct or block fluxes of thermal and solar energy, six types of insulatingwalls are proposed. On the basis of this criterion there are traditional dividing walls (typical walls, wallinsulating...
-
Implementation of 24-hour Blood Pressure Control
Publication -
Passive sonar with cylindrical array
PublicationArtykuł prezentuje sposób wykorzystania sonaru aktywnego z anteną cylindryczną do nasłuchu pasywnego podwodnych źródeł dźwięku. Wykazano, że wykrycie źródła dźwięku i określenie jego namiaru może być zrealizowane bez zmian konstrukcji odbiornika. Wymagana jest jedynie zmiana algorytmów przetwarzania sygnałów w beamformerze. Wykazano również, że w celu zwiększenia dokładności namiaru można zastosować wysokorozdzielcze metody estymacji...
-
Imaging forms in passive sonars
PublicationReferat jest kontynuacją tematyki organizacji zobrazowań we współczesnych systemach hydrolokacyjnych przedstawionej w referacie zaproszonym na ubiegłorocznym OSA dla systemów aktywnych. Tym razem dotyczy organizacji zobrazowań w systemach pasywnych. W praktyce, prócz prostych systemów nasłuchu i rejestracji dźwięków podwodnych, używanych przez badaczy fauny wodnej czy oceanografów, systemy pasywne są wykorzystywane w marynarkach...
-
Microwave Ring Resonator Based Pressure Sensor
PublicationThis paper demonstrates a microwave pressure sensor, which is based on microstrip line-fed ring resonators. The first ring resonator is loaded with the concentric cylindrical shafts, while the same number of the hollow shanks as the shafts are mounted on the second ring resonator. The arrangement of the cylindrical shaft and hollow shank allows for mechanical movement between two substrates while maintaining electrical contact....
-
Application of passive sampling technique in monitoring research on quality of atmospheric air in the area of Tczew, Poland.
PublicationThis paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. Analytical procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID)...
-
Performance of Passive and Active Balancing Systems of Lithium Batteries in Onerous Mine Environment
PublicationTo use lithium-iron-phosphate battery packs in the supply systems of any electric mining equipment and/or machines, the required conditions of work safety must be met. This applies in particular to coal mines endangered by fire and/or explosion. To meet the spark-safety conditions, the cells (together with the battery management system—BMS) must be isolated from the influence of the environment, and therefore placed in special...
-
Influence of the femoral offset on the muscles passive resistance in total hip arthroplasty
PublicationBackground Soft tissue tension is treated as a crucial factor influencing the post-THA dislocation. The femoral offset is regarded as one of the major parameters responsible for the stabilization of the prosthesis. It is unclear which soft tissue is mostly affected by the offset changes. Methods A finite element model of the hip was created. The model comprised muscles, bones, a stem, the acetabular component and a liner. The muscles...
-
Phytoextraction and recovery of rare earth elements using willow (Salix spp.)
PublicationSoil and water contaminations are caused by rare earth elements (REEs) due to mining and industrial activities, that threaten the ecosystem and human health. Therefore, phytoremediation methods need to be developed to overcome this problem. To date, little research has been conducted concerning the phytoremediation potential of Salix for REEs. In this study, two Salix species (Salix myrsinifolia and Salix schwerinii) and two Salix...
-
Selection Pressure in the Evolutionary Path Planning Problem
PublicationThis article compares an impact of using various post-selection methods on the selection pressure and the quality of the solution for the problem of planning the path for a moving object using the evolutionary method. The concept of selection pressure and different methods of post-selection are presented. Article analyses behaviour of post-selection for four options of evolutionary algorithms. Based on the results achieved, waveform...
-
Issues relating to the efficient Application of passive solar protection in multi-family residential buildings
PublicationThe following article is intended to discuss the issues concerning the introduction of passive measures aimed at improving solar protection in multi-family buildings. A system of classifying these methods into two groups of solutions (architectural and material-building) was applied. The first group includes issues concerning facade design, the spatial features of which (such as loggias, balconies and other overhangs) can be treated...
-
Pressure pulsations in turbine blade seal clearance
PublicationThe paper presents the results of numerical and experimental investigations into pressure forces generated in a turbine labyrinth seal. The experiments were performed on a single-stage air model turbine of the impulse type, while the numerical results were obtained by means of CFD Fluent Code. The performed experimental research and numerical calculations prove that in a shroud clearance the pressure pulsates and the effects of...
-
COMPARISON OF BLOOD PRESSURE PREDICTION METHODS
PublicationIn the paper dierent approaches of predicting blood pressure values are presented. Basically, two methods and theirs modifications are considered. In total, seven algorithms have been examined. Tests have been conducted using both synthetic and clinical data. From our study it follows that none of the examined methods is superior to other.