Filters
total: 3404
-
Catalog
displaying 1000 best results Help
Search results for: CURRENT COLLECTOR DIAGNOSTIC
-
Toxoplasma gondii Recombinant antigen AMA1: Diagnostic Utility of Protein Fragments for the Detection of IgG and IgM Antibodies
PublicationToxoplasma gondii is an important zoonotic protozoan that infects a wide variety of vertebrates as intermediate hosts. For this reason, the diagnosis of this disease is very important and requires continuous improvement. One possibility is to use recombinant antigens in serological tests. Apical membrane antigen 1 (AMA1), a protein located in specific secretory organelles (micronemes) of T. gondii, is very interesting in regard...
-
Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
PublicationThis paper presents the compensation tasks performed by a shunt active power filter, including compensation of harmonic currents, reactive power, and an unbalanced load current. The paper demonstrates novel control of the shunt active power filter in a closed-loop system. The control algorithm was verified by performing simulations and compared the simulated results with those obtained in an open-loop control system. All simulations...
-
JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY
Journals -
Annals of Diagnostic Paediatric Pathology
Journals -
Journal of Clinical and Diagnostic Research
Journals -
JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION
Journals -
Automated Diagnostics of Current Pick-Up Disturbances in Electric Traction Networks
PublicationThe present work defines the basic causes of bow disturbances of current pick-up, sets a task of establishing a system of automated control of bow disturbances at feeder zones of electric traction networks, proposes structural variants of the technical system implementation, describes the algorithm of detection of bow disturbances of current pick-up.
-
Behavior of residual current devices at frequencies up to 50 kHz
PublicationThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Diagnostic Analysis of Exhaust Gas with A Quick-Changing Temperature from a Marine Diesel Engine Part II / Two Factor Analysis
PublicationThe article presents a continuation of research carried out to determine the effect of input parameters (changes in engine structure parameters) on selected output parameters (diagnostic measures), based on quickly changing exhaust gas temperature. A method of determining the simultaneous influence of two input factors (the structure parameter and the engine load) on one output factor was presented, as well as an evaluation...
-
Behavior of residual current devices at earth fault currents with DC component
PublicationLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Increase of Diagnostic Capabilities of Voltage Fluctuation Indicies
Publication -
Abdominal epilepsy in patient of schizophrenia - a diagnostic dilemma
PublicationAbdominal epilepsy is a rare and uncomman cause of recurrent abdominal pain. It is commonly occuring in children, but rarely in adolescent and elderly. Paroxysmal episodes of abdominal pain with neurological symptoms like dizziness, lethargy, and abnormal electroencephalogram and remarkable response to anticonvulsant confirms the diagnosis. Here we present a case of schizophrenia, who has repoted with recurrent abdominal pain...
-
Fluorescent spectroscopy of collagen as a diagnostic tool in medicine
Publication -
Diagnostic PCR assay for Microsporum and Trichophyton infections
PublicationWe have previously described a highly sensitive 5-hour PCR test for the rapid diagnosis of onychomycosis which detects any dermatophyte and species-identify T. rubrum from patient specimens. We have subsequently developed and evaluated new PCR tests for detection of Trichophyton and Microsporum canis/audouinii infections.58 dermatophyte isolates (21) Microsporum spp. (4 different species), 35 Trichophyton spp (10 different species)...
-
Guided wave propagation in diagnostic of steel elements
PublicationThis paper is devoted to numerical investigations of elastic wave propagation in steel elements. The aim of this study is to conduct numerical analysis and experimental investigations on the propagation of elastic waves in steel elements in the context of damage detection. In particular, this paper is devoted to detection of damage occurring in the form of notch or changed thickness. This approach utilized the fact that any discontinuities...
-
Guided wave propagation in diagnostic of steel elements
PublicationThis paper is devoted to numerical investigations of elastic wave propagation in steel elements. The aim of this study is to conduct numerical analysis and experimental investigations on the propagation of elastic waves in steel elements in the context of damage detection. In particular, this paper is devoted to detection of damage occurring in the form of notch or changed thickness. This approach utilized the fact that any discontinuities...
-
Parameterized diagnostic module implemented in FPGA structures
Publication -
Abdominal epilepsy in patient of schizophrenia - a diagnostic dilemma
Publication -
Development and Verification of the Diagnostic Model of the Sieving Screen
Publication -
Diagnostic Accuracy of Liquid Biopsy in Endometrial Cancer
PublicationBackground: Liquid biopsy is a minimally invasive collection of a patient body fluid sample. In oncology, they offer several advantages compared to traditional tissue biopsies. However, the potential of this method in endometrial cancer (EC) remains poorly explored. We studied the utility of tumor educated platelets (TEPs) and circulating tumor DNA (ctDNA) for preoperative EC diagnosis, including histology determination. Methods:...
-
Multi gender genetic optimization of diagnostic observers.
PublicationW pracy przedstawiana jest nowa metoda rozwiązywania zadań wielokryterialnej optymalizacji. W omawianej metodzie wykorzystywana jest informacja o genetycznym rodzajniku osobnika w celu odpowiedniego rozróżnienia i agregacji wielu kryteriów. Charakterystyczne cechy mechanizmu są prezentowane na przykładzie wielokryterialnej optymalizacji detekcyjnych obserwatorów stanu.
-
Control theory methods in diagnostic system design
PublicationPraca dotyczy zastosowania wybranych metod teorii sterowania do syntezy al-gorytmów detekcji uszkodzeń. Algorytmy takie, stanowiące istotną gałąźwspółczesnej diagnostyki technicznej obiektów dynamicznych, w swej istocieopierają się na rozwiązaniach odpowiednich zadań odpornego wyznaczania wek-torów resztowych, czyli ważonych błędów oszacowań wyjściadanego obiektu dy-namicznego (nadzorowanego procesu). Na treść pracy...
-
Method of sacrificial anode dual transistor-driving in stray current field
PublicationIn order to control a magnesium anode in a stray current interference field, a dual transistor driving system has been proposed. It consisted of a combination of PNP and NPN transistors. Dual transistor driven system and direct anode to cathode connection were electrochemically tested in 3% NaCl solution. The dual transistor driven system increased the anode efficiency and reduced hydrogen evolution and the risk of embrittlement....
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Comprehensive compensation of grid current distortion by shunt active power filters
PublicationThe paper presents a comprehensive approach to the compensation of grid current distortion in shunt active power filter systems. Four sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Time-current tripping curves of arc fault detection devices
PublicationTripping curves of arc fault detection devices, in accordance with PN-EN 62606 “General requirements for arc fault detection devices” have been presented in the paper. Consequently the most fundamental differences in arc fault detection devices tripping compared to circuit-breakers and residual current devices have been indicated.
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublicationElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
Comparison of residual current devices tripping characteristics for selected residual current waveforms
PublicationZgodnie z normami międzynarodowymi, w instalacjach o zwiększonym ryzyku porażenia prądem elektrycznym należy stosować wyłączniki różnicowoprądowe wysokoczułe. Dla zapewnienia skutecznej ochrony przeciwporażeniowej zainstalowany wyłącznik różnicowoprądowy powinien prawidłowo wykrywać określony kształt prądu różnicowego. W artykule przedstawiono charakterystyki działania wyłączników różnicowoprądowych przy wybranych przebiegach odkształconego...
-
Modular high precision high current source for special applications — Simulation and verification
PublicationThis paper presents selected issues concerning realization of high precision high current source for special applications, where high demands of output parameters of such device are required. A new 80 kW prototype of modular high precision high current source is presented, where output current accuracy reaches 5x10-5. This paper presents also results of operation of the simulation model and of the prototype converter. In order...
-
The tawny owl Strix aluco as a material collector in faunistic investigations: the case study of small mammals in NE Poland
Publication -
Mobility management solutions for current IP and future networks
PublicationEnormous progress in the design of portable electronic devices allowed them to reach a utility level comparable to desktop computers, while still retaining their mobility advantage. At the same time new multimedia services and applications are available for IP users. Unfortunately, the performance of base IP protocol is not satisfactory in mobile environments, due to lack of handover support and higher layer mobility management...
-
Speed sensorless induction motor drive with predictive current controller
PublicationToday, speed sensorless modes of operation are becoming standard solutions in the area of electric drives. This paper presents a speed sensorless control system of an induction motor with a predictive current controller. A closed-loop estimation system with robustness against motor parameter variation is used for the control approach. The proposed algorithm has been implemented using field-programmable gate arrays (FPGAs) and a...
-
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublicationIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublicationIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
Sensorless Control of Induction Machine Supplied by Current Source Inverter
PublicationThe paper describes the voltage control technique of induction machines supplied by a current source inverter. The control system is based on proposed new multi-scalar variables, which are named “r.” The control system contains the output filter capacitor's model. In the sensorless control system the Z type backstepping speed observer was applied. The mathematical dependences are confirmed by simulation and experimental research.
-
Programmable Input Mode Instrumentation Amplifier Using Multiple Output Current Conveyors
PublicationIn this paper a programmable input mode instrumentation amplifier (IA) utilising second generation, multiple output current conveyors and transmission gates is presented. Its main advantage is the ability to choose a voltage or current mode of inputs by setting the voltage of two configuration nodes. The presented IA is prepared as an integrated circuit block to be used alone or as a sub-block in a microcontroller or in a field...
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Determination of Local Corrosion Current from Individual Harmonic Components
PublicationHarmonic analysis has been used in corrosion measurements for several decades. During this period the method has been refined and developed. Nevertheless, the technique has not been applied to properties determination in local scale yet. This paper is focused on local corrosion current measurements based on harmonic analysis. For this purpose, a non-linear nature of electrode processes is used and measured in local scale applying...
-
Security of Cryptocurrencies: A View on the State-of-the-Art Research and Current Developments
Publication[Context] The goal of security is to protect digital assets, devices, and services from being disrupted, exploited or stolen by unauthorized users. It is also about having reliable information available at the right time. [Motivation] Since the inception in 2009 of the first cryptocurrency, few studies have been undertaken to analyze and review the state-of-the-art research and current developments with respect to the security...
-
Dc Leakage Current in Isolated Grid-Connected dc Nanogrid - Origins and Elimination Methods
PublicationThe LV dc system is a relatively new trend in the distribution sector, which seems to grow widely in the near future due to its promising advantages. In this context, LV dc protection and grounding are challenging issues. Although the galvanically isolated connection mode of dc nanogrid to the ac grid has high reliability, the leakage current can still be injected into the ac grid through the interwinding capacitors and the insulation...
-
Improving Control Dynamics of PMSM Drive by Estimating Zero-Delay Current Value
PublicationDynamic performance of current control loop still remains crucial for position-, speed-, and torque-controlled drives. In the study, a current loop solution has been designed for field oriented control of permanent magnet synchronous motors (PMSM). It enhances typical PI controller with an estimator of zero-delay current (ZDC) value. The ZDC estimation allows for selecting substantially higher controller gain. It reduces control...
-
Multiple output second-generation current conveyor utilizing high frequency output stage
PublicationIn this paper a multiple output second-generation current conveyor (MOCCII) is presented. The main advantage of the proposed general circuit architecture over a typical structure, well known in the literature, is the use of a high passband multiple output current mplifier block instead of cascaded current mirrors. It gives similar frequency responses for all the outputs of the current conveyor and also maintains simplicity of the...
-
Diagnostic testing of marine propulsion systems with internal combustion engines by means of vibration measurement and results analysis
PublicationIn this paper selected issues concerning vibration diagnosis of the mechanical system within marine propulsion units have been presented, carried out on the basis of experimental examinations of a real object in which an exceedance of the allowable vibration’s level had been observed. Used diagnosing system has been characterised. A procedure of longitudinal and transverse vibrations shaft lines of the mechanical system within...
-
POSSIBILITY OF IDENTIFICATION OF TECHNICAL CONDITION OF BEARINGS FOR SELF-IGNITION ENGINES BY APPLICATION OF ACOUSTIC EMISSION AS A DIAGNOSTIC SIGNAL
PublicationThis paper presents the results of empirical studies where the acoustic emission (AE) method was applied to identify the technical condition of sliding surfaces of main and crank bearings for main diesel engines. The test results indicate that the measurements of the AE parameters allow the technical condition identification for bearings of this type. The results refer to the measurements of the parameters for AE generated in the...
-
Feedback Control of Doubly-Fed Generator Connected to Current Source Converter
PublicationDoubly-fed induction generator (DFIG) system supplied by current source converter (CSC) is considered in this article. The DFIG can work in two independent modes: AC grid connection and stand-alone mode. The DFIG is connected to the ac grid directly through its stator and the CSC links the rotor side. In this mode, the active and reactive powers of the DFIG must be controlled. This article proposes two control system structures...
-
Exhaust gas temperature measurements in diagnostic examination of naval gas turbine engines. Part II. Unsteady processes
PublicationThe second part of the article presents the results of operating diagnostic tests of a two- and three-shaft engine with a separate power turbine during the start-up and acceleration of the rotor units. Attention was paid to key importance of the correctness of operation of the automatic engine load control system, the input for which, among other signals, is the rate of increase of the exhaust gas flow temperature. The article...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Nonlinear Control of a Doubly Fed Generator Supplied by a Current Source Inverter
PublicationNowadays, wind turbines based on a doubly fed induction generator (DFIG) are a commonly used solution in the wind industry. The standard converter topology used in these systems is the voltage source inverter (VSI). The use of reverse-blocking insulated gate bipolar transistor (RB-IGBT) in the current source inverter topology (CSI), which is an alternative topology, opens new possibilities of control methods. This paper presents...
-
Impact of thermal backfill parameters on current-carrying capacity of power cables installed in the ground
PublicationProper design of power installations with the participation of power cables buried in homogeneous and thermally well-conductive ground does not constitute a major problem. The situation changes when the ground is non-homogeneous and thermally low-conductive. In such a situation, a thermal backfill near the cables is commonly used. The optimization of thermal backfill parameters to achieve the highest possible current-carrying capacity...
-
Marine polymers in tissue bioprinting: Current achievements and challenges
PublicationBioprinting has a critical role in tissue engineering, allowing the creation of sophisticated cellular scaffolds with high resolution, shape fidelity, and cell viability. Achieving these parameters remains a challenge, necessitating bioinks that are biocompatible, printable, and biodegradable. This review highlights the potential of marine-derived polymers and crosslinking techniques including mammalian collagen and gelatin along...