Filters
total: 931
-
Catalog
Search results for: POTENTIOMETRIC TASTE SENSOR
-
Multiple sound sources localization in real time using acoustic vector sensor
PublicationMethod and preliminary results of multiple sound sources localization in real time using the acoustic vector sensor were presented in this study. Direction of arrival (DOA) for considered source was determined based on sound intensity method supported by Fourier analysis. Obtained spectrum components for considered signal allowed to determine the DOA value for the particular frequency independently. The accuracy of the developed...
-
New bis(azobenzocrown)s with dodecylmethylmalonyl linkers as ionophores for sodium selective potentiometric sensors
PublicationNovel biscrowns 1 and 2 were synthesized from 13-membered azobenzocrown ethers containing bromoalkylenoxy chains in para position relative to the azo group. The synthesized diester molecules are dodecylmethylmalonic acid derivatives differing by the linker length. The synthesized compounds have the potential of being used as sodium ionophores in ion-selective electrodes. They were characterized and used as ionophores in classic...
-
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
PublicationThis paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear...
-
Electrochemically directed biofunctionalization of a lossy-mode resonance optical fiber sensor
PublicationIn this work, we present a direct electrochemical biofunctionalization of an indium-tin-oxide-coated lossy-mode resonance optical fiber sensor. The functionalization using a biotin derivative was performed by cyclic voltammetry in a 10 mM biotin hydrazide solution. All stages of the experiment were simultaneously verified with optical and electrochemical techniques. Performed measurements indicate the presence of a poly-biotin...
-
Estimating Traffic Intensity Employing Passive Acoustic Radar and Enhanced Microwave Doppler Radar Sensor
PublicationInnovative road signs that can autonomously display the speed limit in cases where the trac situation requires it are under development. The autonomous road sign contains many types of sensors, of which the subject of interest in this article is the Doppler sensor that we have improved and the constructed and calibrated acoustic probe. An algorithm for performing vehicle detection and tracking, as well as vehicle speed measurement,...
-
Optical Sensor Based Gestures Inference Using Recurrent Neural Network in Mobile Conditions
PublicationIn this paper the implementation of recurrent neural network models for hand gesture recognition on edge devices was performed. The models were trained with 27 hand gestures recorded with the use of a linear optical sensor consisting of 8 photodiodes and 4 LEDs. Different models, trained off-line, were tested in terms of different network topologies (different number of neurons and layers) and different effective sampling frequency...
-
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
PublicationThis article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization...
-
Zirconia-based mixed potential sensor with Pt electrode prepared by spin-coating of polymeric precursor
PublicationMany types of yttria-stabilized zirconia (YSZ) based gas sensors have been explored extensively in recent years. Great attention have been directed to mixed-potential-type gas sensors. It is due to growing concerns with environmental issues. Not without a significance is the fact of very attractive performance of this type of sensor allowing to detect low concentration of pollutant gases. In this paper two types of YSZ based mixed-potential...
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublicationThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter
PublicationA new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...
-
Fiber optic sensor based on optical frequency domain reflectometry.Optical Fibres and their Applications VIII.
PublicationW pracy przedstawiono wyniki modelowania systemu sensorów światłowodowych wykorzystującego reflektometrię optyczną w dziedzinie częstotliwości. Na podstawie tych wyników zrealizowano quasi-rozłożony sensor temperatury. Zaprezentowano i omówiono wyniki pomiarów.
-
Multi-functional sensor based on photonic crystal fiber using plasmonic material and magnetic fluid
PublicationA unique highly sensitive photonic crystal fiber is investigated based on plasmonic material and magnetic fluid (MF) for the simultaneous measurement of temperature and magnetic field sensor. The designed sensor is explored by tracing the different parameters such as birefringence, coupling length, power spectrum, and the peak wavelength of the transmission intensity. The magnetic field and temperature computation are attained...
-
Using differential pressure sensor to measure nitrous oxide level in a tank
PublicationA method for measuring the level of liquid nitrous oxide oxidizer in a hybrid rocket motor oxidizer tank is proposed. Presented approach is more accurate than the most commonly used method of this measurement, which employs weighting of the whole sounding rocket or an oxidizer tank. In our solution we use a differential pressure sensor to measure the change of pressure at the bottom of an oxidizer tank in comparison to the pressure...
-
MONTE CARLO MODELING OF OPTICAL SENSOR FOR POST-OPERATIVE FREE FLAP MONITORING
PublicationAfter a preliminary study of the currently employed methods in vitality monitoring of the tissue flaps (TRAM, DIEP, SIEA), a usefulness of optical techniques is discussed. It seems that one of the most promising in monitoring tissue flaps blood flow is a near infrared spectrometry (NIRS). However, a special design of a measurement sensor has to be developed. First, basing on the literature study an optical “window” is characterized....
-
Road surface roughness estimation employing integrated position and acceleration sensor
PublicationAssessment of a surface quality being an essential task for the authorities supervising the roads provides the subject of the paper. Information about riding quality of a pavement, important for drivers, both in terms of their comfort and safety is collected during experiments employing mobile sensors. The paper describes the use of a miniature position and acceleration sensor for evaluation of the roughness of the road surface....
-
Fibre-Optic pH Sensor
Publication -
Electrocatalytic nitrogen dioxide sensor.
PublicationOpisano konstrukcję i właściwości elektrokatalitycznego czujnika gazów na bazie domieszkowanego samarem tlenku ceru. Pomiary przeprowadzono w mieszaninie syntetycznego powietrza i dwutlenku azotu. Kształt odpowiedzi prądowo - napięciowej zależy od stężenia NO2.
-
Ad Hoc & Sensor Wireless Networks
Journals -
Time-domain measurement methods for R, L and C sensors based on aversatile direct sensor-to-microcontroller interface circuit
PublicationtIn the paper new time-domain measurement methods for determining values of resistive (R), inductive(L) and capacitive (C) sensors based on a versatile direct sensor-to-microcontroller interface for microcon-trollers with internal analog-to-digital converters (ADCs) and analog comparators (ACs) are presented.The interface circuit consists of a reference resistor Rrworking as a voltage divider, a given R, L or C sensorand a microcontroller...
-
On the new possibility of applying oscillating liquid membrane systems for melecular recognition substances responsible for taste.
PublicationSugerowano wczesniej, że układy osylacyjne z membraną ciekłą mogą być uzyte do opracowania sensora smaku. zbadano wpływ substancji odpowiedzialnych za smak należacych do czterech klas samku na charakterystyki osylacyjne oscylatora z mambrana ciekłą i kationowym surfaktantem chlorkiem benzylodimetylotetradecyloamonionowym. Wykazano,że niezaleznie od natury rozpuszczalnika organicznego w membranie ciekłej charkterystyki oscylacyjne...
-
Preparation and Characterization of Microsphere ZnO ALD Coating Dedicated for the Fiber-Optic Refractive Index Sensor
PublicationWe report the fabrication of a novel fiber-optic sensor device, based on the use of a microsphere conformally coated with a thin layer of zinc oxide (ZnO) by atomic layer deposition (ALD), and its use as a refractive index sensor. The microsphere was prepared on the tip of a single-mode optical fiber, on which a conformal ZnO thin film of 200 nm was deposited using an ALD process based on diethyl zinc (DEZ) and water at 100 °C....
-
Comparing traffic intensity estimates employing passive acoustic radar and microwave Doppler radar sensor
PublicationThe purpose of our applied research project is to develop an autonomous road sign with built-in radar devices of our design. In this paper, we show that it is possible to calibrate the acoustic vector sensor so that it can be used to measure traffic volume and count the vehicles involved in the traffic through the analysis of the noise emitted by them. Signals obtained from a Doppler radar are used as a reference source. Although...
-
Development of Gas Sensor Array for Methane Reforming Process Monitoring
PublicationThe article presents a new method of monitoring and assessing the course of the dry methane reforming process with the use of a gas sensor array. Nine commercially available TGS chemical gas sensors were used to construct the array (seven metal oxide sensors and two electrochemical ones). Principal Component Regression (PCR) was used as a calibration method. The developed PCR models were used to determine the quantitative parameters...
-
Efficiency of linear and non-linear classifiers for gas identification from electrocatalytic gas sensor
PublicationElectrocatalytic gas sensors belong to the family of electrochemical solid state sensors. Their responses are acquired in the form of I-V plots as a result of application of cyclic voltammetry technique. In order to obtain information about the type of measured gas the multivariate data analysis and pattern classification techniques can be employed. However, there is a lack of information in literature about application of such...
-
Application of thin diamond films in low-coherence fiber-optic Fabry Pérot displacement sensor
PublicationThe novel fiber-optic low coherence sensor with thin diamond films is demonstrated. The undoped and boron-doped diamond films were elaborated by the use of the microwave plasma enhanced chemical vapor deposition (μPE CVD) system. The optical signal from the Fabry–Pérot cavity made with the application of those thin films is sensitive to displacement. The sensor characterization was made in the range of 0–600 μm. The measurements...
-
A Multifunctional Microwave Filter/Sensor Component Using a Split Ring Resonator Loaded Transmission Line
PublicationThis research is focused on the design and realiza2 tion of a microwave component with multifunctional filter/sensor 3 operation using a resonator-loaded transmission line (TL). It is 4 shown that while the structure acts as a bandstop filter, the 5 phase of the reflection coefficient from the loading resonator(s) 6 on a movable layer can be used for displacement sensing, thus 7 allowing for combining filtering with sensing in...
-
Comparison of Fluoride Ion-Selective Electrode Based Potentiometric Methods of Fluoride Determination in Human Urine
Publication -
An NO2 sensor based on WO3 thin films for automotive applications in the microwave frequency range
PublicationA microwave system dedicated to the detection of nitrogen dioxide in the harsh environment of the Norway highways is proposed. An optimized transmission line type of sensor coated with a tungsten trioxide thin film that changes its electrical properties under NO2 gas exposure is developed. The sensors' response (S) is given in °/GHz and it is calculated based on wideband measurements. The advantage of wideband measurements in comparison...
-
TOXIC GASES IDENTIFICATION USING SINGLE ELECTROCATALYTIC SENSOR RESPONSES AND ARTIFICIAL NEURAL NETWORK
PublicationThe need for precise detection of toxic gases drives development of new gas sensors structures and methods of processing the output signals from the sensors. In literature, artificial neural networks are considered as one of the most effective tool for the analysis of gas sensors or sensors arrays responses. In this paper a method of toxic gas components identification using a electrocatalytic gas sensor as a detector and an artificial...
-
Application of a catalytic combustion sensor (Pellistor) for the monitoring of the explosiveness of a hydrogen-air mixture in the upper explosive limit range
PublicationA new technique is presented for continuous measurements of hydrogen contamination by air in the upper explosive limit range. It is based on the application of a catalytic combustion sensor placed in a cell through which the tested sample passes. The air content is the function of the quantity of formed heat during catalytic combustion of hydrogen inside the sensor. There is the possibility of using the method in industrial installations...
-
Assessing the time effectiveness of trust management in fully synchronised wireless sensor networks
PublicationThe paper presents the results of the time effectiveness assessment of the distributed WSN Cooperative Trust Management Method - WCT2M in a fully synchronized Wireless Sensor Network (WSN). First we introduce some basic types of synchronization patterns in WSN based on the idea of sleep scheduling. Then we explain how WCT2M works in the network applying the fully synchronized sleep scheduling pattern. Such networks were subjected...
-
Sounding Mechanism of a Flue Organ Pipe—A Multi-Sensor Measurement Approach
PublicationThis work presents an approach that integrates the results of measuring, analyzing, and modeling air flow phenomena driven by pressurized air in a flue organ pipe. The investigation concerns a Bourdon organ pipe. Measurements are performed in an anechoic chamber using the Cartesian robot equipped with a 3D acoustic vector sensor (AVS) that acquires both acoustic pressure and air particle velocity. Also, a high-speed camera is employed...
-
Investigation of temperature changes using a microsphere-based fiber-optic sensor
Open Research DataInvestigation of temperature changes using a microsphere-based fiber-optic sensor with a 200 nm ZnO ALD coating for the purpose of validation the design of the sensor, measurement setup and method of examination of electric cell materials.
-
Uncertainty of Postmortem Time Estimation Based on Potassium Ion Determination in Vitreous Humor Using Potentiometric Ion-Selective Electrode and Microwave-Induced Plasma with Optical Emission Spectrometry Methods
PublicationThere is a need for a reliable and independent evaluation and confirmation of the post-mortem interval (PMI) based on objective factors other than only postmortem changes or temperature measurements. Estimating the PMI by examining the concentration of potassium ions in the vitreous humor (VH) has a tradition in forensic toxicology dating back to the mid-20th century. So far, the methods for determining the presence of potassium...
-
Silicon microcantilever with impedance sensor
Open Research DataThe issue of microelectromechanical systems (MEMS) [1] has been enjoying popularity and interest since the 90s of the 20th century. Microcells are one of the simplest devices of this type, but they can be widely used in sensors. There are reports on the possibility of using this type of sensors in the context of such important issues as diagnostics...
-
Relay-aided Wireless Sensor Network Discovery Algorithm for Dense Industrial IoT utilizing ESPAR Antennas
PublicationIndustrial Internet of Things (IIoT) applicationsrequire reliable and efficient wireless communication. Assumingdense Wireless Sensor Networks (WSNs) operating in a harshenvironment, a concept of a Time Division Multiple Access(TDMA) based WSN enriched with Electronically SteerableParasitic Array Radiator (ESPAR) antennas is proposed andexamined in this work. The utilized...
-
FIBRE-OPTIC SENSOR FOR SIMULTANEOUS MEASUREMENT OF THICKNESSAND REFRACTIVE INDEX OF LIQUID LAYERS
PublicationIn this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers. We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry–Pérot interferometer acting as the sensing head. We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We...
-
Electrochemical performance of indium-tin-oxide-coated lossy-mode resonance optical fiber sensor
PublicationAnalysis of liquids performed in multiple domain, e.g., optical and electrochemical (EC), has recently focus significant attention. Our previous works have shown that a simple device based on indium-tin-oxide (ITO) coated optical fiber core may be used for optical monitoring of EC processes. At satisfying optical properties and thickness of ITO a lossy-mode resonance (LMR) effect can be obtained and used for monitoring of optical...
-
<title>Correction of fiber optic ion sensor readings using a fiber optic temperature sensor</title>
Publication -
Determination of chemical oxygen demand (cod) at boron-doped diamond (bdd) sensor by means of amperometric technique
PublicationA boron-doped diamond (BDD) sensor was proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Thin boron doped diamond active sensor layer was deposited on Si wafer and glassy carbon substrate by Microwave Plasma Enhanced Chemical Vapor Deposition (MW PE CVD). The structure of BDD was confirmed by Raman spectra analysis. Broad Raman bands centered at 482 cm-1 and 1219 cm-1 are typical...
-
Determination of Chemical Oxygen Demand (COD) at Boron-doped Diamond (BDD) Sensor by Means of Amperometric Technique
PublicationA boron-doped diamond (BDD) sensor was proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Thin boron doped diamond active sensor layer was deposited on Si wafer and glassy carbon substrate by Microwave Plasma Enhanced Chemical Vapor Deposition (MW PE CVD). The structure of BDD was confirmed by Raman spectra analysis. Broad Raman bands centered at 482 cm-1 and 1219 cm-1 are typical...
-
Measurements and Visualization of Sound Intensity Around the Human Head in Free Field Using Acoustic Vector Sensor
PublicationThis paper presents measurements and visualization of sound intensity around the human head simulator in a free field. A Cartesian robot, applied for precise positioning of the acoustic vector sensor, was used to measure sound intensity. Measurements were performed in a free field using a head and torso simulator and the setup consisting of four different loudspeaker configurations. The acoustic vector sensor was positioned around...
-
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublicationA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
Process control of air stream deodorization from vapors of VOCs using a gas sensor matrix conducted in the biotrickling filter (BTF)
PublicationThis article presents the validity, advisability and purposefulness of using a gas sensor matrix to monitor air deodorization processes carried out in a peat-perlite-polyurethane foam-packed biotrickling filter. The aim of the conducted research was to control the effectiveness of air stream purification from vapors of hydrophobic compounds, i.e., n-hexane and cyclohexane. The effectiveness of hydrophobic n-hexane and cyclohexane...
-
Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)
PublicationLead and its compounds are a serious threat to the environment. Monitoring of this toxic heavy metal is a driving force for the continuous development of novel lead(II) ionophores to be applied in ion-selective electrodes. In this work a highly selective lead(II) ionophore, namely 25,26,27,28-tetrakis(piperidinylthiocarbonylmethylene)-p-tert-butylcalix[4]arene, was used in solid-contact ion-selective electrodes for determination...
-
Spectroscopic and Wireless Sensor of Hematocrit Level
Publication -
Electrocatalytic gas sensor response analysis
PublicationW pracy przedstawiono i porównano metody analizy odpowiedzi elektrokatalitycznych czujników gazów toksycznych. Opisane metody pozwalają na ekstrakcje z odpowiediz czujników informacji o rodzaju gazu oraz o jego stężeniu.
-
Selectivity of amperometric sulfur dioxide sensor.
PublicationW pracy przedstawiono wartości współczynników selektywności amperometrycznego czujnika ditlenku siarki względem siarkowodoru. Obliczenia wykonane zostały w oparciu o krzywe kalibracyjne wyznaczone dla zaprezentowanego wcześniej przez nas amperometrycznego czujnika ditlenku siarki. Analiza krzywych kalibracyjnych pod względem czułości oznaczenia oraz analiza wartości amperometrycznych współczynników selektywności odgrywa dużą pomocniczą...
-
Nanocrystalline undoped ceria oxygen sensor.
PublicationW pracy przedstawiono wyniki badań struktury i elektrycznych właściwości nanokrystalicznego czujnika na bazie niedomieszkowanego tlenku ceru. Zbadano wpływ ciśnienia parcjalnego tlenu na rezystancję cienkowarstwowego tlenku ceru. Konduktancja tlenku ceru w zakresie stężeń tlenu od 10ppm do 100% ma charakter eksponecjalny z parametrem -0.25. Zbadano szybkość odpowiedzi oraz wpływ dwutlenku azotu oraz dwutlenku siarki na odpowiedź...
-
Optimal Sensor Placement for Damage Detection
PublicationW pracy przedstawiono dwie konfiguracje czujników PZT do detekcji uszkodzeń w płytach. Omówion zalety i wady obu konfiguracji.