Filters
total: 466
-
Catalog
Search results for: PRZETWORNICA DC-DC
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on "unknown" object using 2-wire probe
Open Research DataThe dataset presents impedance spectrum of "black-box" object with interesting phase characteristics. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Comparison of XPS spectra of Ag3d for silver nanostructures and bulk material
Open Research DataAg nanostructures were prepared on borosilicate glass (Corning 1737F) and Si substrates. In both cases, the substrateswere cleaned with acetylacetone and then rinsed in ethanol. Thin Ag films (2 and 6 nm thickness) were deposited using a tabletop dc magnetron sputtering coater (EM SCD 500, Leica) in pure Ar plasma (argon, Air Products 99.999%). The...
-
Mikropompa elektrohydrodynamiczna na ciecz dielektryczną zasilana napięciem stałym
PublicationW niniejszym artykule zaprezentowano projekt i działanie miniaturowej pompy elektrohydrodynamicznej (EHD) zasilanej napięciem stałym przeznaczonej do chłodzenia elementów elektronicznych. Zmierzono natężenie przepływu cieczy oraz ciśnienie wytwarzane przez pracującą mikropompę. Maksymalne natężenie przepływu, 0,5 ml/min, uzyskano dla napięcia 12 kV. Zmierzone ciśnienie wyniosło 500 Pa przy przyłożonym napięciu 6 kV. Maksymalny...
-
Electrochemical properties of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrodes in solid oxide cells: Impedance study of symmetrical electrodes
PublicationThis work evaluates porous Sr0.86Ti0.65Fe0.35O3 (STF35) as a possible oxygen electrode material for Solid Oxide Cells. The powder synthesis was performed by solid state method. Characterization included DC electrical conductivity study of sintered bulk samples and impedance spectroscopy study of symmetrical electrodes deposited on gadolinium doped ceria substrates. Measurements were carried out in atmospheres with different pO2...
-
Impedance of metastable pitting corrosion
PublicationPrzeprowadzono badania impedancyjne metastabilnego procesu korozji wżerowej. Kształt chwilowych widm impedancyjnych otrzymanych w wyniku eksperymentu jest ściśle związany z przebiegiem prądu dc. O szybkość korozji wewnątrz aktywnego zaatakowania decyduje proces przeniesienia ładunku. Ekspansja aktywnej powierzchni jest proporcjonalna do zmian podwójnej warstwy elektrycznej. Zaobserwowane zostały również zmiany rezystancji elektrolitu...
-
Spin-glass behavior in a binary Pr 3 Ir intermetallic compound
PublicationPolycrystalline Pr3Ir was synthesized by arc melting. Its cementite-type crystal structure (Pnma) was confirmed by powder X-ray diffraction and estimated lattice parameters are in agreement with literature. Physical properties were measured by means of the ac and dc magnetic susceptibility, electrical resistivity and heat capacity. Our results indicate spin-glass behavior in Pr3Ir with a freezing temperature Tf = 6.58 K and activation...
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublicationThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
UV-Light-Induced Fluctuation Enhanced Sensing by WO3-Based Gas Sensors
PublicationWO3-based gas sensors were investigated under UV-light irradiation and at different working temperatures with the object of achieving superior sensitivity and selectivity. Resistance fluctuations in the WO3 layer were studied together with dc resistance measurements. The data were taken in synthetic air, ethanol, nitrogen dioxide, and mixtures of these gases. We conclude that UV irradiation can easily be applied to enhance the...
-
Dendritic cells as regulators of immune response and their application in therapy
PublicationW publikacji opisano rolę komórek dendrytycznych (DC) w regulowaniu układu immunologicznego. W ostatnich latach nastąpił przełom w postrzeganiu komórek dendrytycznych, które są jedną z kluczowych populacji komórek odpornościowych, nie tylko jako komórek prezentujących antygeny i indukujących układ odpornościowy, lecz także posiadających zdolność do wyciszania jego aktywności czy do aktywnego zabijania komórek nowotworowych.
-
Fluctuation-enhanced scent sensing using a single gas sensor
PublicationWykrywanie zapachów podczas aromaterapii może być przeprowadzone za pomocą pojedynczego sensora gazów. W pracy rozważono efektywność detekcji zapachów olejków eterycznych za pomocą rezystancji DC oraz zjawisk fluktuacyjnych w tych sensorach, typu TGS2600,TGS2602,TGS823. Badania koncentrowały się na praktycznym zastosowaniu w aromaterapii do określania intensywności emitowanego zapachu. Opisano szczegółowo system do emisji zapachów.
-
Multipulse inverter structures with low voltage distortion
PublicationA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...
-
Exercise bike powered electric generator for fitness club appliances
PublicationA generator powered by a stationary bicycle for the purposes of generating electricity for fitness club appliances is considered. A generator is connected to a stationary bicycle in such a way as the circular rotation of the front wheel rotates the coils of wires inside the generator between the poles of the magnets inside the generator. The resulting Direct Current is channeled to the attached battery bank and converted into different...
-
Novel therapeutic compound acridine–retrotuftsin action on biological forms of melanoma and neuroblastoma
PublicationPURPOSE: As a continuation of our search for anticancer agents, we have synthesized a new acridine-retrotuftsin analog HClx9-[Arg(NO2)-Pro-Lys-Thr-OCH3]-1-nitroacridine (named ART) and have evaluated its activity against melanoma and neuroblastoma lines. Both tumors develop from cells (melanocytes, neurons) of neuroectodermal origin, and both are tumors with high heterogeneity and unsatisfactory susceptibility to chemotherapies....
-
Measurements of radiation emission of a portable power bank with a capacity of 5200 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Experimental investigation of the weight averaging of pulse frequency modulated sensor output signal
Open Research DataThe research aims to practically verify the results of theoretical analysis and simulations of the efficiency of weight averaging of pulse frequency modulated signal. For this purpose, a suitable test stand was built, and the control software in the LabVIEW environment was prepared. Then, a series of experiments were carried out to process and analyze...
-
Falowniki wielopoziomowe 6kV/1MVA do napędów o regulowanej prędkości obrotowej i układów kompensacji mocy biernej
PublicationW referacie przedstawiono konstrukcję modułowego tranzystorowego przekształtnika napięcia 6 kV/1 MVA nowej generacji o dwukierunkowym przepływie energii pomiędzy siecią średniego napięcia (SN) a silnikiem indukcyjnym klatkowym, przeznaczonego do napędów SN o regulowanej prędkości obrotowej. Istota rozwiązania przedstawionego przekształtnika zawiera się w zastosowaniu trójstopniowej struktury. Stopnień wejściowy oraz stopień wyjściowy...
-
Noise and Electro-Ultrasonic Spectroscopy of Conducting PolymerThick Films
PublicationThick conducting films based on conducting polymer are characterized by DC conductivity and noise in temperature range 10 to 300 K. Conducting polymers could be used e.g. for the top electrode (cathode) in the solid tantalum or niobium capacitors. On the conducting polymer layer the top layer of carbon/graphite and/or silver polymer based pastes is applied in the capacitor technology. Our samples structure consists of conducting...
-
Assessment of Fuel Cells’ State of Health by Low-Frequency Noise Measurements
PublicationWe proposed applying low-frequency (flicker) noise in proton-exchange membrane fuel cells under selected loads to assess their state of health. The measurement set-up comprised a precise data acquisition board and was able to record the DC voltage and its random component at the output. The set-up estimated the voltage noise power spectral density at frequencies up to a few hundred mHz. We observed the evolution of the electrical...
-
Effects of UV light irradiation on fluctuation enhanced gas sensing by carbon nanotube networks
PublicationThe exceptionally large active surface-to-volume ratio of carbon nanotubes makes it an appealing candidate for gas sensing applications. Here, we studied the DC and low-frequency noise characteristics of a randomly oriented network of carbon nanotubes under NO2 gas atmosphere at two different wavelengths of the UV light-emitting diodes. The UV irradiation allowed to sense lower concentrations of NO2 (at least 1 ppm) compared to...
-
Compensation of Dead Time Effects for Shunt Active Power Filters
PublicationThe paper presents a comprehensive approach to the compensation of the grid current distortion for shunt active power filter systems. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the estimation of compensating currents and grid voltages, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Modelowanie falownika napięcia z quasi-rezonansowym obwodem pośredniczącym
PublicationW pracy przedstawiono szerokopasmowe modelowanie falownika napięcia z quasi-rezonansowym obwodem pośredniczącym w środowisku symulatora SABER. Modele łączników energoelektronicznych oraz algorytm sterowania zostały zaimplementowane z wykorzystaniem języka programowania MAST. Dokładność modelu zweryfikowano w oparciu o porównanie charakterystycznych przebiegów symulacyjnych układu z przebiegami eksperymentalnymi oraz analizę porównawczą...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Investigation of plasmon resonance in a silver nanoparticles
Open Research DataSilver nanostructures were prepared on borosilicate glass (Corning 1737F) substrates. Thin Ag films (1–9 nm thickness) were deposited using a table-top dc magnetron sputtering coater (EM SCD 500, Leica) in pure Ar plasma (argon, Air Products 99.999%). The Ag target was of 99.99% purity, the rate of layer deposition was about 0.4 nm·s−1, and the incident...
-
SEM images of tge gold nanostructures on silicon
Open Research DataAu nanostructures were prepared on Si(111) as a substrate. The substrates (1 × 1 cm2 of area) were cleaned with acetylacetone and then rinsed in ethanol. Thin Au films (with thicknesses in a range of 1.7–5.0 nm) were deposited using a table-top dc magnetron sputtering coater (EM SCD 500, Leica) under pure Ar plasma conditions (Argon, Air Products 99.999%)....
-
Comprehensive compensation of grid current distortion by shunt active power filters
PublicationThe paper presents a comprehensive approach to the compensation of grid current distortion in shunt active power filter systems. Four sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Synthesis and Testing of BCZY/LNZ Mixed Proton–electron Conducting Composites for Fuel Cell Applications
PublicationA composite of BaCe0.6Zr0.2Y0.2O3–δ and Li2O:NiO:ZnO was investigated for fuel cell applications. The composite was successfully synthesized and its phase stability was confirmed at temperatures up to 900 °C. The influence of sintering and pressing aids on density was also investigated. Electrical properties were measured. DC electrical conductivity was about 8•10-4 S/m at 845 K. Open circuit voltage measurements in wet hydrogen...
-
Solutions of inverter systems in Shore-to-Ship Power supply systems
PublicationThe article presents a clearly formulated need for installing S2SP (Shore to Ship Power) systems, in particular Medium Voltage (MV) systems, along with certain solutions of modern inverter systems used in those systems. Requirements and basic configurations of S2SP systems are discussed, focusing in particular on capabilities of the S2SP system with DC distribution busbar. Moreover, on the background of the executing assumptions...
-
Bezpieczeństwo elektryczne przy urządzeniach przytorowych niskiego napięcia zelektryfikowanych linii kolejowych
PublicationW referacie przedstawiono zasady zasilania urządzeń pomocniczych niskiego napięcia, obsługujących zelektryfikowany szlak kolejowy. Ze względu na oddziaływanie sieci trakcyjnej DC 3 kV (zagrożenie porażeniem, prądami błądzącymi), szczególnej uwagi wymaga wybór układu sieci nn i środków ochrony przeciwporażeniowej, a także konfiguracja instalacji uziemiających. Za podstawę przyjęto system trakcji o grupowym uszynieniu otwartym, które...
-
Modular multipulse voltage source inverters with integrating coupled reactors
PublicationA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...
-
Investigation of magnetic order in a new intermetallic compound Nd2PtGe3
PublicationIn the present study we report a successful synthesis of the new intermetallic compound Nd2PtGe3 by an arc-melting method. The powder X-ray diffraction analysis indicates that this compound crystallizes in an disordered variant of the AlB2-type structure (space group P6/mmm, no. 191) with lattice parameters a = 4.2455 Å and c = 4. 1933 Å. The compound exhibits a cluster-glass transition below Tf = 2.9 K, characterized through ac...
-
Formowanie napięć wyjściowych trójfazowego przekształtnika sieciowego
PublicationW artykule przedstawiono kompensację dwu zasadniczych zjawisk powodujących zniekształcenia prądów fazowych przekształtnika sieciowego. Pierwszym z nich są zniekształcenia napięcia sieci. W celu ich eliminacji zaproponowano uśrednianie za okres podstawowej harmonicznej uchybu regulatora napięcia obwodu pośredniczącego oraz predykcję napięcia sieci. Drugim natomiast są zniekształcenia napięć wyjściowych przekształtnika sieciowego....
-
The adaptive backstepping control of PMSM supplied by current source inverter for the field weakening region
PublicationThe sensorless control system of permanent magnet synchronous motor PMSM supplied by current source inverter for field weakening operation is presented in this paper. The adaptive backstepping control system and the backstepping speed observer are presented. The control system is based on multi-scalar variables. The control variables are: dc-link voltage and the output current vector pulsation. The control system was named voltage...
-
The influence of azide and imidazole on the properties of Mn- and Cd-based networks: conductivity and nonlinear phenomena
PublicationWe report a study on a family of four new Mn- and Cd-azide-imidazolate-based compounds with various crystal architectures. Notably, three of these compounds display noncentrosymmetric crystal arrangements at room temperature, a rare phenomenon in hybrid organic–inorganic materials. Both nonlinear optical (NLO) and electrical phenomena in these compounds are observed. The NLO processes include second and third harmonic generation,...
-
Jerzy H. Czembor Prof. dr hab.
PeopleYear of birth: 1965, Poland, Work address: Plant Breeding and Acclimatization Institute –National research Institute (IHAR-PIB), Radzikow, 05-870 Blonie, Poland. Scientific disciplines: agricultural sciences, plant pathology, plant physiology, genetics. Specialization: phytopathology, mycology, plant genetics, molecular genetics, plant breeding, breeding for disease resistance, biotechnology, evaluation of genetic resources,...
-
Ochrona przeciwporażeniowa w urządzeniach przytorowych niskiego napięcia zelektryfikowanych linii kolejowych
PublicationW artykule przedstawiono zasady ochrony przeciwporażeniowej w instalacjach urządzeń pomocniczych niskiego napięcia, obsługujących zelektryfikowany szlak kolejowy. Ze względu na oddziaływanie sieci trakcyjnej DC 3 kV (zagrożenie porażeniem, prądami błądzącymi), szczególnej uwagi wymaga wybór układu sieci niskiego napięcia i środków ochrony przeciwporażeniowej, a także konfiguracja instalacji uziemiających. Rozważono system trakcji...
-
Redukcja liczby przełączeń tranzystorów w falowniku kaskadowym z wektorową modulacją szerokości impulsów
PublicationW artykule zaprezentowano metody ograniczania liczby przełączeń tranzystorów wybranych mostków kaskadowego falownika napięcia z wektorową modulacją szerokości impulsów. Zaproponowane rozwiązanie umożliwi sterowanie temperaturą poszczególnych mostków H przekształtnika, w którym ten sam strumień powietrza wykorzystano do chłodzenia kilku mostków H. Zmiana liczby przełączanych tranzystorów nie wpływa na dokładność...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 24h exposition
Open Research DataThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 48h exposition
Open Research DataThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Simulation of perovskite-based CuI/CH3NH3PbI3/TiO2 solar cell performance
Open Research DataThe presented data set is part of the theoretical research on novel thin-layer lead-halide perovskite solar cells with different inorganic transparent conductive oxides used as charge transport layers. In this study CuI/CH3NH3PbI3/TiO2 model structure (Model 1) was investigated by the use of the SCAPS-1D simulation method (https://scaps.elis.ugent.be/).
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...