displaying 1000 best results Help
Search results for: LOW-VOLUME MEASUREMENTS
-
A Comparability of Renal Length and Volume Measurements in MRI and Ultrasound in Children
PublicationIntroduction: Despite the significant increase in use of magnetic resonance imaging (MRI) in children, there is still a lack of normal reference values of renal size in this method and reference values are being interpolated from the ultrasound (US) studies. The study provides comparative analysis of agreement in renal length and volume measurements between MRI and ultrasound. Materials and Methods: Ninety-three children with a...
-
On the use of a charge balancing method for low energy measurements
PublicationThe paper presents the method for the estimation of the energy consumption of the low-power microcontroller-based devices. Due to high dynamics of the changes of the supply current of the tested devices during the operational cycle, the consumed energy estimation is not easy. In order to avoid disadvantages of known methods, the charge balancing method was employed similarly like in some types of A/D converters.
-
Low-volume label-free SARS-CoV-2 detection with the microcavity-based optical fiber sensor
PublicationAccurate and fast detection of viruses is crucial for controlling outbreaks of many diseases; therefore, to date, numerous sensing systems for their detection have been studied. On top of the performance of these sensing systems, the availability of biorecognition elements specific to especially the new etiological agents is an additional fundamental challenge. Therefore, besides high sensitivity and selectivity, such advantages...
-
Noise measurements on low noise pavements - problems with inhomogeneity of wearing course
PublicationDuring the last several years, when performing numerous CPX noise measurements on low noise pavements,significant inhomogeneity of the wearing course was observed in numerous cases. Similar problems were almost not existing regarding to the dense pavements.In general three main reasons of inhomogeneity can be defined. The first one are imperfections in technology of production of a asphalt mix or/and errors made already during...
-
Low-Level Aerial Photogrammetry as a Source of Supplementary Data for ALS Measurements
PublicationThe development of laser scanning technology ALS allows to make high-resolution measurements for large areas result-ing in significant reduction of costs. The main stakeholders at heights data received from the airborne laser scanning is mainly state administration. The state institutions appear among projects such as ISOK. Each point is classified in ac-cordance with the standard LAS 1.2, our research focuses on the class 6 -...
-
Assessment of Fuel Cells’ State of Health by Low-Frequency Noise Measurements
PublicationWe proposed applying low-frequency (flicker) noise in proton-exchange membrane fuel cells under selected loads to assess their state of health. The measurement set-up comprised a precise data acquisition board and was able to record the DC voltage and its random component at the output. The set-up estimated the voltage noise power spectral density at frequencies up to a few hundred mHz. We observed the evolution of the electrical...
-
Low-Level Aerial Photogrammetry as a Source of Supplementary Data for ALS Measurements
Publication -
"Creating a numerical model of noise conditions based on the analysis of traffic volume changes in cities with low and medium structure.
PublicationThe subject of this research study is to analyze noise conditions of the selected area in the city of Gdańsk using data related to traffic volume changes during a day. This is because daily distribution of noise levels is much more helpful for noise control and reduction than traditional maps with Lden levels indicated. Calculations are made with the use of a numerical model developed at the Gdansk Univ. of Technology and implemented...
-
"Creating a numerical model of noise conditions based on the analysis of traffic volume changes in cities with low and medium structure.
PublicationThe subject of this research study is to analyze noise conditions of the selected area in the city of Gdańsk using data related to traffic volume changes during a day. This is because daily distribution of noise levels is much more helpful for noise control and reduction than traditional maps with Lden levels indicated. Calculations are made with the use of a numerical model developed at the Gdansk Univ. of Technology and implemented...
-
Automatic Correction of Non-Anechoic Antenna Measurements using Low-Pass Filters
PublicationPrototype measurements belong to key steps in the development of antenna structures. They are normally performed in expensive facilities, such as anechoic chambers (ACs). Alternatively, antenna performance can be extracted (at a low cost) in non-anechoic conditions upon appropriate post-processing. Unfortunately, existing correction algorithms are difficult to set up and prone to failure, which limits their practical usefulness....
-
A Low-Cost System for Far-Field Non-Anechoic Measurements of Antenna Performance Figures
PublicationPrototype measurements are the key step in the development of antenna structures. Typically, their far-field characteristics are validated in expensive, dedicated facilities such as open range sites, or anechoic chambers. Despite being necessary for obtaining high-precision data (e.g., for device qualification), the use of costly infrastructure might not be fully justified when the main goal of measurements includes demonstration...
-
Accuracy of a low-cost autonomous hexacopter platforms navigation module for a photogrammetric and environmental measurements
PublicationA photogrammetry and environmental measurements from an unmanned aerial vehicle (UAV) are a low-cost alternative for a traditional aerial photogrammetry. A commercial off-the-shelf products (COTS) offers a variety of cheap components that a suitable to be used on board a UAV. In this paper a low-cost navigation module based on Ublox NEO-M8N GPS and Pixhawk flight controller have been described, as a main extrinsic parameters source...
-
One year performance evaluation of low volume road with cold recycled base course on the basis of FWD and Dynamic Modulus tests
PublicationArticle presents results of assessment of performance of trial section of flexible pavement with cold recycled base constructed on low volume road within typical contract conditions. Performance evaluation was made based on Falling Weight Deflectometer (FWD) test performed during construction stage – 2 times on the top of cold recycled base course – 28 and 180 days after compaction of base course and 2 times on the top of the wearing...
-
Device characteristics extraction by low frequency noise measurements; Someresults on the state-of-the-art MOSFET´s
PublicationPrzedstawiono wyniki pomiarów i analizy szumów tranzystorów MOSFET z izolatorem bramki wykonanym z SiO2 i HfO2. Wyniki pomiarów wykorzystano do oszacowania gęstości aktywnych stanów na powierzchni użytego tlenku i porównano z wynikami otrzymanymi metodą charge-pumping.
-
Low-Cost Open-Hardware System for Measurements of Antenna Far-Field Characteristics in Non-Anechoic Environments
PublicationExperimental validation belongs to the most important steps in the development of antenna structures. Measurements are normally performed in expensive, dedicated facilities such as anechoic chambers, or open-test sites. A high cost of their construction might not be justified when the main goal of antenna verification boils down to demonstration of the measurement procedure, or rough validation of the simulation models used for...
-
Inhomogeneity of low-noise wearing courses evaluated by tire/road noise measurements using the close-proximity method
PublicationPerforming numerous analyses of tire/road noise measurements on low-noise pavements during the last several years, the authors observed significant inhomogeneity of the wearing course in numerous cases, while similar problems were almost non-existent when dense pavements were measured. Three main causes of low-noise pavement inhomogeneity can be defined. The first one is imperfections in the technology used for asphalt mix production...
-
Computer-aided analysis of signals from a low-coherence Fabry-Perot interferometer used for measurements of biological samples
PublicationThe aim of the study was to develop an automated computer-aided system for analysis of spectrograms obtained from measurements of biological samples performed with a low-coherence Fabry-Pérot interferometer. Information necessary to determine dispersion characteristics of measured materials can be calculated from the positions of the maxima and minima that are present in their spectra. The main challenge faced during the development...
-
Fracture surface topography measurements analysis of low-alloyed corrosion resistant steel after bending-torsion fatigue tests
PublicationIn this paper, an assessment of a topography measurement method for fracture surfaces of 10HNAP steel after bending-torsion fatigue tests was performed. Surface roughness was measured by using a non-contact Focus Variation Microscopy (FVM) technique in which the non-measured points (NMPs) and outliers (spikes) were removed by the application of general methods. The results revealed, that the optical measurement method introduced...
-
The current amplifier in low frequency noise measurements; Absolute calibration and rigorous 1/f noise extraction for MOSFET´s
PublicationPrzedstawiono budowę wzmacniacza prądowego i sposób obliczania szumów wyjściowych przy dołączonym do wejścia rezystorze wzorcowym. Przedstawiono wyniki eksperymentów potwierdzających prawidłowość przyjętego sposobu postępowania. Zaproponowano metodę wyznaczania składowej 1/f szumów drenu tranzystora MOSFET.
-
Long term measurements of PM1, PM2.5, PM10 and NO2 in open-air at Gdansk (Poland) area using low-cost sensors together with the reference results
Open Research DataThe measurements results of open-air measurements made using the following low-cost sensors: particulate matter (PM) sensor SPS30 from Sensirion, NO2 electrochemical sensor SGX-7NO2 from SGX Sensortech, NO2 electrochemical sensor 7E4-NO2 from SemaTech, compact MOS air quality sensor MiCS 2714 from SGX Sensortech, BME280 (Bosch) environmental sensor...
-
Low frequency noise measurements in advanced silocon devices.**2003, 136 s.116 rys. bibliogr. 29 poz. maszyn. Pomiary małoczęstotliwościowych szumów zaawansowanych elementów krzemowych. Rozprawa doktorska /15.04.2003./ Inst. Natl. P. Grenoble Promotorzy: prof. dr hab. inż. L. Spiralski, dr CNRS G. Ghibaudo.
PublicationW pracy przedstawiono automatyczny system do pomiarów małoczęstotliwoscio-wych szumów struktur elementów półprzewodnikowych. System umożliwia automa-tyczne wyznaczanie charakterystyk stałoprądowych badanego elementu, pomiarszumów i wyznaczanie gęstości widmowej mocy w zadanym zakresie polaryzacji.Przytoczono wyniki przeprowadzonych testów systemu. Ważną składową pracy wy-niki pomiarów szumów tranzystorów MOS i bipolarnych...
-
Measurements of the Hydraulic Fluids Compressibility
PublicationPerformance of the hydrostatic high-pressure drive systems is affected by the changes of working fluid’s volume. Presence of air bubbles in the fluid cause this problem to be even more serious. To study this phenomenon precise measurements of fluid’s bulk modulus are necessary. Differ-ent measurement methods are applied, but they are either limited to low pressure range or give inaccurate results. To solve the problem the new...
-
Speech Intelligibility Measurements in Auditorium
PublicationSpeech intelligibility was measured in Auditorium Novum on Technical University of Gdansk (seating capacity 408, volume 3300 m3). Articulation tests were conducted; STI and Early Decay Time EDT coefficients were measured. Negative noise contribution to speech intelligibility was taken into account. Subjective measurements and objective tests reveal high speech intelligibility at most seats in auditorium. Correlation was found between...
-
Peptide-Based Rapid and Selective Detection of Mercury in Aqueous Samples with Micro-Volume Glass Capillary Fluorometer
PublicationMercury, a toxic heavy metal produced through both natural and anthropogenic processes, is found in all of Earth’s major systems. Mercury’s bioaccumulation characteristics in the human body have a significant impact on the liver, kidneys, brain, and muscles. In order to detect Hg2+ ions, a highly sensitive and specific fluorescent biosensor has been developed using a novel, modified seven amino acid peptide, FY7. The tyrosine ring...
-
Low-Coherence Interferometer with Nanocrystalline Diamond Films with Potential Application to Measure Small Biological Samples
PublicationThe study investigates a case of a low-coherence fiber-optic Fabry–Prerot interferometer with a nanocrystalline diamond (NCD) mirror. The method of achieving double density of interference fringes is proposed by the application of birefringent material in the cavity of the interferometer. It can be used to reduce sample volume in comparison to conventional interferometers. The use of a biocompatible diamond mirror makes it specifically...
-
Enhancement of fiber-optic low-coherence Fabry-Pérot interferometer with ZnO ALD films
PublicationIn this paper investigation of the enhanced fiber-optic low coherence Fabry-Pérot interferometer with zinc oxide (ZnO) film deposited by atomic layer deposition (ALD) was presented. Model of the interferometer, which was constructed of single-mode optical fiber with applied ZnO ALD films, was built. The interferometer was also examined by means of experiment. Measurements were performed for both reflective and transmission modes,...
-
Fracture Areas Quantitative Investigating of Bending-Torsion Fatigued Low-Alloy High-Strength Steel
PublicationIn this study, the impact of pseudo-random non-proportional bending-torsion fatigue loadings proportion on the fatigue life and the fracture surface topography was analyzed. Investigation was carried out for 24 specimens made of S355J2 steel with 11 different ratios of maximum stresses λ. For these cases, after the fatigue tests, the surface topography measurements were carried out using an optical profilometer, using the focus...
-
Paweł Możejko dr hab.
People -
Submerged objects modeling and storing in a global reference context using multiresolution spline technique,
PublicationContemporary records from multibeam sonars or even elevations from 3D shuttle radar topography missions feature high resolution. On the other hand, bathymetric models of a different resolution from different sensors are available as well, beginning from very high resolution MBS records and low resolution records coming from regular scattered measurements. Approximating and eventually visualizing the high volume scattered 3D raster...
-
Stanisław Galla dr inż.
PeopleStanisław Galla was born in 1970 in Gdańsk. He graduated from the Secondary Technical School of Mechanical and Electrical Engineering in Gdansk (1990). He studied at the Faculty of Electrical Engineering at Gdansk University of Technology (graduated in 1996). His PhD thesis entitled "Methodology for increasing the accuracy of low frequency measurements of periodic disturbance indicators in low voltage networks" was defended in...
-
Paweł Burdziakowski dr inż.
PeoplePaweł Burdziakowski, PhD, is a professional in low-altitude aerial photogrammetry and remote sensing, marine and aerial navigation. He is also a licensed flight instructor and software developer. His main areas of interest are digital photogrammetry, navigation of unmanned platforms and unmanned systems, including aerial, surface, underwater. He conducts research in algorithms and methods to improve the quality of spatial measurements...
-
Niskokoherencyjne czujniki światłowodowe wykorzystujące cienkowarstwowe struktury nanodiamentowe
PublicationZnaczny rozwój technologii wytwarzania czujników światłowodowych spowodował, że są one powszechnie dostępne i stosowane w wielu gałęziach przemysłu, nauki oraz medycyny. Zastosowanie nowych materiałów w konstrukcji takich czujników niesie za sobą duży potencjał. Celem rozprawy jest przedstawienie możliwości wykorzystania cienkowarstwowych struktur nanodiamentowych w niskokoherencyjnych czujnikach światłowodowych, które poprawią...
-
Effects of UV light irradiation on fluctuation enhanced gas sensing by carbon nanotube networks
PublicationThe exceptionally large active surface-to-volume ratio of carbon nanotubes makes it an appealing candidate for gas sensing applications. Here, we studied the DC and low-frequency noise characteristics of a randomly oriented network of carbon nanotubes under NO2 gas atmosphere at two different wavelengths of the UV light-emitting diodes. The UV irradiation allowed to sense lower concentrations of NO2 (at least 1 ppm) compared to...
-
Dew Formation and Chemistry Near a Motorway in Poland
PublicationIn this study, the influence of traffic intensity on dewformation efficiency and chemistry is presented. The measurementswere conducted near the A4 motorway in SW Poland in almost flatland relief with intense agricultural activity. The dew/hoarfrost wascollected by means of insulated plain passive radiative condensersat three sites: AN and AS located in the close vicinity of themotorway (30 m) on the opposite sides of the road,...
-
Poroelastic Road Surface – a Promising Road Traffic Noise Abatement Solution
PublicationRoad surfaces have a direct impact on the generation of noise by rolling tyres, the main and dominant source of noise of moving vehicles, as well as may affect propagation of noise emitted by all noise sources of a vehicle. Thus there is no doubt that pavement should be considered as one of the major potential road traffic noise abatement measure. Low noise pavements of existing types may in new conditions provide up to 8 dB of...
-
Evolution of charge density wave order in continuous solid solutions Lu(Ni1-xCox)C2
PublicationPseudo-ternary solid solutions, Lu(Ni1-xCox)C2 (0 ≤ x ≤ 1), were studied by means of powder X-ray diffraction, differential thermal analysis as well as electrical resistivity and heat capacity measurements. The crystal structure of the Lu(Ni1-xCox)C2 series, as investigated by means of X-ray powder diffraction, is of structure type CeNiC2, space group Amm2, Pearson symbol oS8. The structural analysis reveals a non-monotonous evolution,...
-
Comparative Analysis of the Coffee and Cocoa Industry By-Products on the Performance of Polyethylene-Based Composites
PublicationThe application of plant-based by-products from the food industry as minimally processed functional fillers for polymeric composites is an increasingly popular trend among researchers and manufacturers. While minimizing the preprocessing of lignocellulosic fillers leads to an increase in the sustainability of the overall composite and a decrease of the carbon footprint, filler modification is usually indispensable to obtaining...
-
Comparative Analysis of the Cofee and Cocoa Industry By‑Products on the Performance of Polyethylene‑Based Composites
PublicationThe application of plant-based by-products from the food industry as minimally processed functional fillers for polymeric composites is an increasingly popular trend among researchers and manufacturers. While minimizing the preprocessing of lignocellulosic fillers leads to an increase in the sustainability of the overall composite and a decrease of the carbon footprint, filler modification is usually indispensable to obtaining...
-
Monitoring of lysozyme thermal denaturation by volumetric measurements and nanoDSF technique in the presence of N-butylurea
PublicationThe results of thermal studies of denaturation of hen egg white lysozyme (HEWL) in water and an aqueous solution of N-butylurea (BU) are presented. High-precision densimetric measurements were used to characterize and analyze the changes of the specific volume, v, during temperature elevation. The temperature of the midpoint of protein denaturation was also determined by nanoDSF technique (differential scanning fluorimetry). The...
-
Investigations of Energy Conversion and Surface Effect for Laser-Illuminated Gold Nanorod Platforms
PublicationAchieving a quick temperature increase is a burning issue for biophysical applications, like germ inactivation and tumor ablation, and for energy performances, like solar collectors and steam generators. Based on the plasmon resonance phenomenon, noble metallic nanoparticles have emerged as promising weapons due to their very high biocompatibility, optical properties, and high surface-to-volume ratio, increasing energy conversion...
-
Urban dew formation efficiency and chemistry in Poland
PublicationThe measurements of dew formation efficiency and chemistry were performed in Poland in September 2009, as a part of a longer, two-year sampling campaign. Pairs of sites, representing centers of major Polish cities and rural conditions in three different regions, were compared. With the aim to get more detailed landuse-oriented characteristics of dew, two additional sites were set close to Wroclaw. Collection of dew at each site...
-
Modulation of dielectric properties in low-loss polypropylene-based composites at GHz frequencies: theory and experiment
PublicationPolymer composites with high dielectric constant and low loss tangent are highly regarded as substrates for modern high-speed electronics. In this work, we analyze the high-frequency dielectric properties of two types of composites based on polypropylene infused with high-dielectric-constant microparticles. Two types of fillers are used: commercial ceramics or titanium oxide ( TiO2) with different concentrations. The key observation...
-
Measurement of mass flow of viscous liquid through a Cylindrical Orifice under laminar flow (CylOr)
Open Research DataThe data was obtained as part of the project "Measurement of mass flow of viscous liquid through a Cylindrical Orifice under laminar flow (CylOr)", in which flow tests of hydraulic oil through a cylindrical orifice with a thickness of l = 25 mm and a throat b = 0.5 (diameter pipes D = 50 mm, orifice diameter d = 25 mm) on the test stand at the Department...
-
The influence of pressure drop on the working volume of a hydraulic motor
PublicationReliability and maintenance analysis of hydraulic positive machines basicly focused on the processes of their wear and failure. But in order to correctly assess the mechanical and volumetric efficiency of a hydraulic motor, both at the stage of development research or at the stage of control tests during its exploitation, the working volume of this motor must be correctly determined. Therefore this paper proposes a new method of...
-
US not bright but right method of thyroid volume estimation even in large and substernal extended goitres. Comparison of US and three methods of CT thyroid evaluation - prospective study.ON LINE
PublicationBackground Ultrasound is nowadays a method of choice for thyroid volume assessment. However, its disadvantage is some inaccuracy, which is said to be higher in huge, especially substernally extended goitres. Aims The aim of the study was to compare the US and CT thyroid volumetric measurements: multi-observers (CT MO) and one-observer (CT OO) to CT planimetry results (CT Pl) in patients with large goitres. Materials & Methods The...
-
"3D-Breast System for Determining the Volume of Tissue Needed for Breast Reconstruction"
PublicationThis article presents methods for surface reconstruction and volume determination based on the point cloud created by 3D imaging. Such a system would be used to accurately estimate breast volume in patients classified for breast reconstruction surgery at plastic surgery centers. To develop such a system, various methods of determining volume, based on images from the Intel D435i camera, were tested. In addition, an application...
-
Determination of the theoretical and actual working volume of a hydraulic motor
PublicationA new methodology of determination of the theoretical and actual working volume of a hydraulic motor based on the characteristics of the delivered flow rate into hydraulic motor vs. the rotational speed at a constant pressure drop in the working chambers is described in this paper. A new method of describing the delivered flow rate into a motor per one shaft revolution as a nonlinear function of the pressure drop in the motor working...
-
Optimization of the System for Determining the Volume of Tissue Needed for Breast Reconstruction
PublicationThis article presents techniques for reconstructing surfaces and volume calculations using a point cloud generated from 3D imaging. The main objective of this article was to optimize the voxel size for the most accurate representation of the surface of the female breast. We experimented with different methods for determining volume using images from the Intel D435i camera. In addition, we designed application and measurement station...
-
An advanced tool integrating failure and sensitivity analysis into novel modeling of the stormwater flood volume
PublicationAn innovative tool for modeling the specific flood volume was presented that can be applied to assess the need for stormwater network modernization as well as for advanced flood risk assessment. Field measurements for a catchment area in Kielce, Poland, were used to apply the model and demonstrate its usefulness. This model extends the capability of recently developed statistical and machine learning hydrodynamic models developed...
-
3D-Breast System for Determining the Volume of Tissue Needed for Breast Reconstruction
Publication3D imaging systems can be used to effectively determine breast volumes for surgical applications. This article presents methods for surface reconstruction and volume determination based on the point cloud created by 3D imaging. Such a system would be used to accurately estimate breast volume in patients classified for breast reconstruction surgery at plastic surgery centers. To develop such a system, various methods of determining...