Search results for: MULTI-PULSE RECTIFIERS - Bridge of Knowledge

Search

Search results for: MULTI-PULSE RECTIFIERS

Search results for: MULTI-PULSE RECTIFIERS

  • Multi-pulse VSC arrangements with coupled reactors

    Publication

    - Year 2016

    This paper presents a novel approach to the multipulse VSC (Voltage Source Converter) arrangements based on several conventional inverter modules connected in parallel by using coupled reactors. This solution reduces the THD of the output voltage, despite the low switching frequency of transistors. The advantage of the proposed solution is also a relatively small rated power of the reactors. Proposed new arrangements for different...

    Full text to download in external service

  • A Special Multi-Pulse Converter with Small Active Power Filter

    Publication

    - Year 2007

    Full text to download in external service

  • SiC-based T-type modules for multi-pulse inverter with coupled inductors

    Publication

    - Year 2017

    The paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...

    Full text to download in external service

  • A multi-pulse diode rectifier with a coupled three-phase reactor and additional small shunt active power filter

    Publication

    - Year 2007

    Full text to download in external service

  • A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux

    Publication

    - ENERGIES - Year 2020

    In this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...

    Full text available to download

  • Output voltage, current and DC-link voltages under SVPWM, experimental results

    Open Research Data

    The dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The comparison studies between proposed Space Vector Pulse-Width...

  • Output voltage, current and DC-link voltages under SPWM, experimental results

    Open Research Data

    The dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The Carrier-Based Pulse-Width Modulation (CBPWM) technique was...

  • High Frequency Harmonics Emission in Smart Grids

    Publication

    - Year 2013

    Pulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....

    Full text to download in external service

  • Low Frequency Conducted Emissions of Grid Connected Static Converters

    Publication

    Pulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....

    Full text to download in external service

  • Dual drive control under SVPWM, experimental results

    Open Research Data

    The dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The analysis includes the behaviour of the drive system, examining the dynamic system response to speed and angle changes, and encompassing data...

  • A robust 18-pulse diode rectifier with coupled reactors

    The article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...

    Full text available to download

  • High Signal Resolution Pulse Oximetry as a Prognostic Indicator of Radiotherapy Toxicity: A Pilot Study

    Publication

    - Pulse - Year 2021

    Introduction: Radiotherapy plays a prominent role in the multidisciplinary treatment of cancers. Despite new irradiation techniques, radiation-induced cardiotoxicity remains a leading cause of morbidity and mortality. Therefore, prognostic indicators of radiotherapy toxicity are essential. This study aimed to investigate the influence of applied radiotherapy on the pulse wave recording and thereby on...

    Full text to download in external service

  • Diagnostyka analogowych filtrów wielosekcyjnych oparta na magistrali testującej IEEE1149.1

    Przedstawiono nową koncepcję testera JTAG BIST do samo-testowania torów analogowych opartych na wielosekcyjnych filtrach wyższego rzędu w mieszanych sygnałowo mikrosystemach elektronicznych sterowanych mikrokontrolerami i wyposażonych w magistralę testującą IEEE1149.1 (JTAG). Bazuje ona na metodzie diagnostycznej opartej na przekształce-niu transformującym próbki odpowiedzi czasowych kolejnych sekcji filtra pobudzonego impulsem...

    Full text available to download

  • Reliability of Pulse Measurements in Videoplethysmography

    Reliable, remote pulse rate measurement is potentially very important for medical diagnostics and screening. In this paper the Videoplethysmography was analyzed especially to verify the possible use of signals obtained for the YUV color model in order to estimate the pulse rate, to examine what is the best pulse estimation method for short video sequences and finally, to analyze how potential PPG-signals can be distinguished from...

    Full text available to download

  • Directed pulse dynamics

    Publication

    Introducing a projection method into a one-dimensional model of a pulse propagation in isotropic media, we derive and investigate a system of equation describing dynamics ultrashort pulses of opposite directions ofpropagation and ones with interaction of directed pulses with different polarization.

    Full text to download in external service

  • Cascaded doubly fed induction generator using PFC rectifiers

    Publication

    - Year 2009

    Full text to download in external service

  • Measuring Pulse Rate with a Webcam

    In this paper a simple method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face images captured from a webcam. The desired signal is obtained by proper channel selection and principal component analysis. To determine the accuracy of the method an ECG signal is collected together with a video recordings. The effectiveness of the algorithm is considered...

    Full text to download in external service

  • Transient modeling in common DC link of power converters

    Publication

    - Science, Technology and Arts Research Journal - Year 2020

    Предмет исследования. Представлена математическая модель силовых преобразователей электропривода, питающихся от общего звена постоянного тока, на примере тяговых электроприводов карьерного самосвала БЕЛАЗ-90 мощностью 280 кВт. Модель выполнена в пакете MATLAB/Simulink. Новизна предложенной модели заключается в применении новой топологии силовой схемы для исследования работы двух инверторов, под- ключенных к одному звену постоянного...

    Full text available to download

  • IEEE Pulse

    Journals

    ISSN: 2154-2287

  • Analysis of the Accuracy of Pulse Estimation Using Smart Watches

    Publication

    The purpose of this paper is to perform an analysis of the accuracy of the pulse estimation by comparing readings from a smartwatch with readings from medical devices. The study required writing applications that allow continuous pulse measurement. As a result, two applications were created for the smartwatch. The first one is dedicated to Android Wear devices, while the other one is compatible with Tizen watches. The next step...

    Full text to download in external service

  • Directed electromagnetic pulse dynamics: projecting operators method

    In this article, we consider a one-dimensional model of electromagnetic pulse propagation in isotropic media, takinginto account a nonlinearity of the third order. We introduce a method for Maxwell's equation transformation on thebasis of a complete set of projecting operators. The operators correspond to wave dispersion branches including thedirection of propagation. As the simplest result of applying the method, we derive a system...

    Full text to download in external service

  • Asynchronous WAM with Irregular Pulse Repetition

    Publication

    Radiolocation systems for aviation based on Multi-Lateration (MLAT) typically use a set of synchronised ground sensors to receive radio signals broadcast by onboard transmitters. In most cases, the sensor synchronisation in Wide Area Multi-Lateration Systems (WAM) is provided by Global Navigation Satellite System (GNSS) receivers. However, in the case of synchronisation failure, there is still a possibility to estimate the coordinates...

    Full text available to download

  • Influence of preprocessing techniques on pulse pressure velocity determination

    Publication

    Pulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...

    Full text to download in external service

  • The accuracy of pulse rate estimation from the sequence of face images

    Publication

    - Year 2016

    The goal of this paper is to analyze the accuracy of pulse rate estimation from the sequence of face images. Simulated and real signals were used to evaluate two pulse rate estimators; one for frequency domain and the second one for time domain using the autocorrelation function. The results show that the mean difference between the reference measurements and estimated pulse rate values are about 2bpm. In the analysis of short...

    Full text to download in external service

  • Digital Processing of Frequency–Pulse Signal in Measurement System

    Publication

    - Year 2018

    The work presents the issue of the use of multichannel measurement systems of sensors processing input value to impulse signal frequency. The frequency impulse signal obtained from such sensors is often required to be processed at the same time with a voltage signal which is obtained from other sensors used in the same measurement system. In such case, it is usually necessary to sample the output signals from all sensors in the...

    Full text available to download

  • New Architecture of Solid-State High-Voltage Pulse Generators

    Publication

    - ENERGIES - Year 2022

    The application of the nanosecond pulsed electric field (nsPEF) for biomedical treatments has gained more interest in recent decades due to the development of pulsed power technologies which provides the ability to control the electric field dose applied during tests. In this context, the proposed paper describes a new architecture of solid-state high-voltage pulse generators (SSHVPG) designed to generate fully customised sequences...

    Full text available to download

  • Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset

    Publication

    - Year 2022

    The dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.

    Full text available to download

  • Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes

    Publication

    - BIOSENSORS & BIOELECTRONICS - Year 2021

    Non-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...

    Full text available to download

  • Evaluation of Facial Pulse Signals Using Deep Neural Net Models

    Publication

    - Year 2019

    The reliable measurement of the pulse rate using remote photoplethysmography (PPG) is very important for many medical applications. In this paper we present how deep neural networks (DNNs) models can be used in the problem of PPG signal classification and pulse rate estimation. In particular, we show that the DNN-based classification results correspond to parameters describing the PPG signals (e.g. peak energy in the frequency...

    Full text to download in external service

  • Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity

    Publication

    In this paper the simple and robust method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face image captured from webcam. The desired signal was obtained by proper channel selection and principal component analysis. A developed non-contact method of heart rate monitoring is shown in the paper. The proposed technique may have a great value in monitoring...

    Full text to download in external service

  • Compact and Integrated High-Power Pulse Generation and Forming System

    This paper presents comprehensive analytical, numerical and experimental research of the compact and integrated high-power pulse generation and forming system based on the flux compression generator and the electro-explosive forming fuse. The paper includes the analysis of the presented solution, starting from the individual components studies, i.e., the separate flux compression generator tests in field conditions and the forming...

    Full text available to download

  • Elimination of impulsive disturbances from archive audio files – comparison of three noise pulse detection schemes

    Publication

    The problem of elimination of impulsive disturbances (such as clicks, pops, ticks, crackles, and record scratches) from archive audio recordings is considered and solved using autoregressive modeling. Three classical noise pulse detection schemes are examined and compared: the approach based on open-loop multi-step-ahead signal prediction, the approach based on decision-feedback signal prediction, and the double threshold approach,...

    Full text to download in external service

  • Blood Pressure - Pulse Transit Time Relationships: Comparative Studies

    Publication

    A non-invasive and continuous blood pressure estimation could allow a better diagnosis and an earlier detection of various diseases. It could be performed using a photoplethysmography. However, it requires that a relation between blood pressure and pulse transit time is known. Eleven theoretical formulas were used in obtaining the simulated and noise free synthetic data. Then, they were utilized in validation of three, commonly...

    Full text to download in external service

  • Can we rely on the pulse transit time - pressure relationship - models comparison

    Publication

    An unobtrusive, noninvasive and continuous pressure measurement is invaluable however, still being under research and development. There are many attempts proposing an appropriate relationship between pulse pressure velocity and pressure. Fifteen different formulas, both theoretical and experimental, describing relation between blood pressure and crosssectional area of the vessel were examined. Using these formulas the relation...

    Full text to download in external service

  • Sonar Pulse Detection Using Chirp Rate Estimation and CFAR Algorithms

    Publication

    This paper presents a new approach to sonar pulse detection. The method uses chirp rate estimators and algorithms for the adaptive threshold, commonly used in radiolocation. The proposed approach allows detection of pulses of unknown parameters, which may be used in passive hydrolocation or jamming detection in underwater communication. Such an analysis is possible thanks to a new kind of imaging, which presents signal energy in...

    Full text available to download

  • Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.

    Publication

    - Frontiers of Optoelectronics - Year 2017

    In this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...

    Full text available to download

  • Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter

    Publication

    - Year 2016

    The paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...

    Full text to download in external service

  • A Meta-Analysis of Pulse Arrival Time Based Blood Pressure Estimation

    The paper presents a preliminary meta-analysis of the sample correlation between pulse arrival time (PAT) and blood pressure (BP). The aim of the study was to verify sample correlation coefficient between PAT and BP using an affine model BP = a · P AT + b for systolic and diastolic blood pressure. The databases included in the search were the IEEE Xplore Digital Library, Springer Link and Google Scholar. Only papers from 2005 to...

    Full text to download in external service

  • Current divider-based nanosecond high current pulse measuring systems

    Publication

    This paper presents the analysis of the new approach to the measurement methodology of significant values (in order of hundreds of kA) and huge steepness (in order of MA/μs) current pulses based on current dividers along with a comparison of the various types transducers suitability in measuring systems with such extreme parameters. Such dividers are used to extend the measurement ranges of current transducers with limited current...

    Full text available to download

  • The concept of a new two-stage fuse for high power pulse forming

    Publication

    This manuscript introduces the concept, physical operating principle and studies on a new and unique two stage forming fuse (TSFF) with interstage spark gap commutation and presents its application for forming high power pulses of extreme parameters. The paper classifies TSFF performance and compares it with conventional single-stage forming fuses. The conclusions are supported by analytical and experimental studies in laboratory...

    Full text available to download

  • Effects of laser pulse duration in two-photon vision threshold measurements

    Publication

    - Proceedings of SPIE - Year 2021

    Pulsed near-infrared (NIR) light sources can be successfully applied for both imaging and functional testing of the human eye, as published recently1. These two groups of applications have different requirements. For imaging applications, the most preferable is invisible scanning beam while efficiently visible stimulating beam is preferable for functional testing applications. The functional testing of human eye using NIR laser...

    Full text to download in external service

  • EM-Driven Multi-Objective Optimization of Antenna Structures in Multi-Dimensional Design Spaces

    Publication

    - Year 2014

    Feasible multi-objective optimization of antenna structures is presented. An initial set of Pareto optimal solutions is found using a multi-objective evolutionary algorithm (MOEA) working with a fast surrogate antenna model obtained by kriging interpolation of coarse-discretization EM simulation data. To make the surrogate construction computationally feasible in multi-dimensional design space, the space subset containing non-dominated...

    Full text to download in external service

  • Effect of pulse laser treatment at different process variables on mechanical behavior of carbon nanotubes electrophoretically deposited on titanium alloy

    Purpose: Titanium and its alloys are widely used as biomaterials for long-term implants, but they are usually surface-modified due to their weak bioactivity and wear resistance. Laser processing was used to modify the surface layer, and elemental carbon was a component of the deposited coatings. This research aims to use a combination of both methods based on preliminary electrophoretic deposition of multi-wall carbon nanotubes...

    Full text to download in external service

  • Recurrent potential pulse technique for improvement of glucose sensing ability of 3D polypyrrole

    In this work, a new approach for using a 3D polypyrrole (PPy) conducting polymer as a sensing material for glucose detection is proposed. Polypyrrole is electrochemically polymerized on a platinum screen-printed electrode in an aqueous solution of lithium perchlorate and pyrrole. PPy exhibits a high electroactive surface area and high electrochemical stability, which results in it having excellent electrocatalytic properties. The...

    Full text available to download

  • Multi agent grid systems

    Publication

    - Year 2012

    This chapter presents an idea of merging grid and volunteer systemswith multi agent systems. It gives some basics concerning multi agentsystem and the most followed standard. Some deliberations concerningsuch an existing systems were made in order to finally present possibilities of introducing agents into the Comcute system.

  • Mechanical durability and electroanalytical performance of 3D-printed multi-material sensors

    The data set consists tensile strength, electric resistance, electrochemical characteristics and physicochemical studies of multi-material 3D printed systems, including their sensing performance during detection of antibiotics in an industrial sewage. Additionally, contact angle measurements and SEM micrographs of the electrode surfaces were included.

  • Low-Cost Multi-Objective Optimization Yagi-Uda Antenna in Multi-Dimensional Parameter Space

    Publication

    A surrogate-based technique for fast multi-objective optimization of a multi-parameter planar Yagi-Uda antenna structure is presented. The proposed method utilizes response surface approximation (RSA) models constructed using training samples obtained from evaluation of the low-fidelity antenna model. Utilization of the RSA models allowsfor fast determination of the best possible trade-offs between conflicting objectives in multi-objective...

    Full text to download in external service

  • Fiber Optic Pulse Sequencers/Desequencers

    Publication

    - Year 1987

    Full text to download in external service

  • Selective Harmonic Elimination PWM For a Cascaded Multi-level Inverter

    Publication

    - Year 2020

    This paper deals with the selective harmonic elimination pulse width modulation (SHE-PWM) technique. This technique is used for the elimination of selected dominant low order harmonics in the multi-level inverter output voltage. The presence of these harmonics is the essential drawback of such kind of inverters; especially when it is used for the control of different AC drivers. The SHE-PWM is based...

    Full text to download in external service

  • Multi-state multi-reference Møller-Plesset second-order perturbation theory for molecular calculations

    This work presents multi‐state multi‐reference Møller–Plesset second‐order perturbation theory as a variant of multi‐reference perturbation theory to treat electron correlation in molecules. An effective Hamiltonian is constructed from the first‐order wave operator to treat several strongly interacting electronic states simultaneously. The wave operator is obtained by solving the generalized Bloch equation within the first‐order...

    Full text to download in external service