Search results for: PULSE DYNAMICS - Bridge of Knowledge

Search

Search results for: PULSE DYNAMICS

Search results for: PULSE DYNAMICS

  • Directed pulse dynamics

    Publication

    Introducing a projection method into a one-dimensional model of a pulse propagation in isotropic media, we derive and investigate a system of equation describing dynamics ultrashort pulses of opposite directions ofpropagation and ones with interaction of directed pulses with different polarization.

    Full text to download in external service

  • Directed electromagnetic pulse dynamics: projecting operators method

    In this article, we consider a one-dimensional model of electromagnetic pulse propagation in isotropic media, takinginto account a nonlinearity of the third order. We introduce a method for Maxwell's equation transformation on thebasis of a complete set of projecting operators. The operators correspond to wave dispersion branches including thedirection of propagation. As the simplest result of applying the method, we derive a system...

    Full text to download in external service

  • Interaction of modes in nonlinear acoustics: theory and applications to pulse dynamics.

    Ogólna teoria oddziaływania modów hydrodynamicznych opiera się na wyprowadzeniu równań różniczkowych nieliniowych. Mody rozumiane są tu jako wektory własnych układów praw zachowań hydrodynamicznych. Rozpatrywano zjawiska towarzyszące fali akustycznej w przepływie lepkim nieliniowym. Uwzględniono płyny w każdym fizycznym równaniu stanu.

  • Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes

    Publication

    - BIOSENSORS & BIOELECTRONICS - Year 2021

    Non-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...

    Full text available to download

  • Ultrashort Opposite Directed Pulses Dynamics with Kerr Effect and Polarization Account

    We present the application of projection operator methods to solving the problem of the propagation and interaction of short optical pulses of different polarizations and directions in a nonlinear dispersive medium. We restrict ourselves by the caseof one-dimensional theory, taking into account material dispersion and Kerr nonlinearity. The construction of operators is delivered in two variants: for the Cauchy problem and for the...

    Full text to download in external service

  • Methods of measurement signal acquisition from the rotational flow meter for frequency analysis

    Publication

    - EPJ Web of Conferences - Year 2017

    One of the simplest and commonly used instruments for measuring the flow of homogeneous substances is the rotational flow meter. The main part of such a device is a rotor (vane or screw) rotating at a speed which is the function of the fluid or gas flow rate. A pulse signal with a frequency proportional to the speed of the rotor is obtained at the sensor output. For measurements in dynamic conditions, a variable interval between...

    Full text to download in external service

  • Modeling and Evaluation of Electric Treeing Phenomena in Polymeric Cable Insulation

    Publication
    • Q. Khan
    • S. S. Refaat
    • H. Abu-Rub
    • H. Toliyat
    • M. Olesz

    - Year 2021

    This paper investigates the treeing phenomenon in polymeric materials such as crosslinked polyethylene (XLPE) that is widely used in medium and high voltage power cables as primary insulation. The modeling of electrical tree growth in the insulation from its initiation to breakdown is significant research work that illustrates the discharge dynamics and its impact on aging process in polymeric insulation. This study utilizes pulse...

    Full text to download in external service

  • Acoustic heating produced in the thermoviscous flow of a bingham plastic

    This study is devoted to the instantaneous acoustic heating of a Bingham plastic. The model of the Bingham plastic's viscous stress tensor includes the yield stress along with the shear viscosity, which differentiates a Bingham plastic from a viscous Newtonian fluid. A special linear combination of the conservation equations in differential form makes it possible to reduce all acoustic terms in the linear part of of the final equation...

    Full text available to download

  • Acoustic heating produced in the thermoviscous flow of a Bingham plastic

    This study is devoted to the instantaneous acoustic heating of a Bingham plastic. The model of the Bingham plastic's viscous stress tensor includes the yield stress along with the shear viscosity, which differentiates a Bingham plastic from a viscous Newtonian fluid. A special linear combination of the conservation equations in differential form makes it possible to reduce all acoustic terms in the linear part of of the final equation...

    Full text available to download

  • Asynchronous Charge Carrier Injection in Perovskite Light-Emitting Transistors

    Publication

    - Advanced Electronic Materials - Year 2023

    Unbalanced mobility and injection of charge carriers in metal-halide perovskite light-emitting devices pose severe limitations to the efficiency and response time of the electroluminescence. Modulation of gate bias in methylammonium lead iodide light-emitting transistors has proven effective in increasing the brightness of light emission up to MHz frequencies. In this work, a new approach is developed to improve charge carrier...

    Full text available to download

  • Laser-Induced Graphitization of Polydopamine on Titania Nanotubes

    Publication

    Since the discovery of laser-induced graphite/graphene, there has been a notable surge of scientific interest in advancing diverse methodologies for their synthesis and applications. This study focuses on the utilization of a pulsed Nd:YAG laser to achieve graphitization of polydopamine (PDA) deposited on the surface of titania nanotubes. The partial graphitization is corroborated through Raman and XPS spectroscopies and supported...

    Full text available to download

  • Type III Responses to Transient Inputs in Hybrid Nonlinear Neuron Models

    Publication

    - SIAM JOURNAL ON APPLIED DYNAMICAL SYSTEMS - Year 2021

    Experimental characterization of neuronal dynamics involves recording both of spontaneous activity patterns and of responses to transient and sustained inputs. While much theoretical attention has been devoted to the spontaneous activity of neurons, less is known about the dynamic mechanisms shaping their responses to transient inputs, although these bear significant physiological relevance. Here, we study responses to transient...

    Full text available to download

  • Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset

    Publication

    - Year 2022

    The dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.

    Full text available to download

  • High Signal Resolution Pulse Oximetry as a Prognostic Indicator of Radiotherapy Toxicity: A Pilot Study

    Publication

    - Pulse - Year 2021

    Introduction: Radiotherapy plays a prominent role in the multidisciplinary treatment of cancers. Despite new irradiation techniques, radiation-induced cardiotoxicity remains a leading cause of morbidity and mortality. Therefore, prognostic indicators of radiotherapy toxicity are essential. This study aimed to investigate the influence of applied radiotherapy on the pulse wave recording and thereby on...

    Full text to download in external service

  • Reliability of Pulse Measurements in Videoplethysmography

    Reliable, remote pulse rate measurement is potentially very important for medical diagnostics and screening. In this paper the Videoplethysmography was analyzed especially to verify the possible use of signals obtained for the YUV color model in order to estimate the pulse rate, to examine what is the best pulse estimation method for short video sequences and finally, to analyze how potential PPG-signals can be distinguished from...

    Full text available to download

  • The accuracy of pulse rate estimation from the sequence of face images

    Publication

    - Year 2016

    The goal of this paper is to analyze the accuracy of pulse rate estimation from the sequence of face images. Simulated and real signals were used to evaluate two pulse rate estimators; one for frequency domain and the second one for time domain using the autocorrelation function. The results show that the mean difference between the reference measurements and estimated pulse rate values are about 2bpm. In the analysis of short...

    Full text to download in external service

  • Analysis of the Accuracy of Pulse Estimation Using Smart Watches

    Publication

    The purpose of this paper is to perform an analysis of the accuracy of the pulse estimation by comparing readings from a smartwatch with readings from medical devices. The study required writing applications that allow continuous pulse measurement. As a result, two applications were created for the smartwatch. The first one is dedicated to Android Wear devices, while the other one is compatible with Tizen watches. The next step...

    Full text to download in external service

  • Hybrid Modulation for Modular Voltage Source Inverters with Coupled Reactors

    This paper proposes and discusses a concept of a hybrid modulation for the control of modular voltage source inverters with coupled reactors. The use of coupled reactors as the integrating elements leads to significant reduction in the size and weight of the circuit. The proposed modulation combines novel coarsely quantized pulse amplitude modulation (CQ-PAM) and innovative space-vector pulse width modulation (SVPWM). The former...

    Full text available to download

  • Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity

    Publication

    In this paper the simple and robust method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face image captured from webcam. The desired signal was obtained by proper channel selection and principal component analysis. A developed non-contact method of heart rate monitoring is shown in the paper. The proposed technique may have a great value in monitoring...

    Full text to download in external service

  • Time domain model of the resonance-based electromagnetic pulses emission system

    In the literature, the emission properties of the electromagnetic field pulse systems based on high voltage antennas (HVR) have been widely described. In order to increase the emission efficiency by extending duration and increasing amplitude of the impulse it is possible to use a resonance system tuned to the parameters of the signal shaped in the pulse forming circuit. The synthesis of a time-domain simulation model of a complex...

    Full text available to download

  • Influence of preprocessing techniques on pulse pressure velocity determination

    Publication

    Pulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...

    Full text to download in external service

  • The forming and emission of high power electromagnetic pulses

    Publication

    An impulse energy source, a power conditioning system and an electromagnetic field emitter are essential to generate an electromagnetic field pulse (EMFP) with a specific frequency bandwidth. Selected simulation results for a power conditioning system consisting of a fuse opening switch and a paraboloidal electromagnetic emitter have been presented in this article. The synthetic system examined in the simulation is powered by an...

    Full text to download in external service

  • Modular multipulse voltage source inverters with integrating coupled reactors

    Publication

    - Year 2016

    A novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...

    Full text to download in external service

  • The Influence of Laser Alloying of Ti13Nb13Zr on Surface Topography and Properties

    The laser alloying is a continually developing surface treatment because of its significant and specific structuration of a surface. In particular, it is applied for Ti alloys, being now the most essential biomaterials` group for load-bearing implants. The present research was performed on the Ti13Nb13Zr alloy subject to laser modification in order to determine the treatment effects on surface topography and its some mechanical...

    Full text available to download

  • Blood Pressure Estimation Based on Blood Flow, ECG and Respiratory Signals Using Recurrent Neural Networks

    Publication

    The estimation of systolic and diastolic blood pressure using artificial neural network is considered in the paper. The blood pressure values are estimated using pulse arrival time, and additionally RR intervals of ECG signal together with respiration signal. A single layer recurrent neural network with hyperbolic tangent activation function was used. The average blood pressure estimation error for the data obtained from 21 subjects...

    Full text to download in external service

  • The forming and emission of high power electromagnetic pulses

    Publication

    An impulse energy source, a power conditioning system and an electromagnetic field emitter are essential to generate an electromagnetic field pulse (EMFP) with a specific frequency bandwidth. Selected simulation results for a power conditioning system consisting of a fuse opening switch and a paraboloidal electromagnetic emitter have been presented in this article. The synthetic system examined in the simulation is powered by...

    Full text to download in external service

  • Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter

    Publication

    - Year 2016

    The paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...

    Full text to download in external service

  • Estimating Intercept Range of Silent Sonar

    Publication

    - Year 2013

    When used in military application, sonars should ensure secretiveness. There is some evidence suggesting that silent sonars have a significant advantage over pulse sonars in the respect. If improved, the secretiveness of silent sonar translates into the distance over witch its soundings signal are detected by intercept sonars. The article gives estimated distances for far, medium, and short range sonars operating in the oceans...

  • A robust 18-pulse diode rectifier with coupled reactors

    The article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...

    Full text available to download

  • A concept of software extension of 3D low-PRF radar systems to 4D semi-medium-PRF radar systems

    Publication

    We present a concept of software modification of three-dimensional (3D) radar systems, designed to work in the low pulse repetition frequency mode, that equips them with the ability to estimate the radial velocity and to properly measure the range of targets that are detected outside the radar’s instrumented range. Despite the fact that the proposed modifications are designed so as to require only minor changes in software, they...

    Full text available to download

  • Evaluation of Facial Pulse Signals Using Deep Neural Net Models

    Publication

    - Year 2019

    The reliable measurement of the pulse rate using remote photoplethysmography (PPG) is very important for many medical applications. In this paper we present how deep neural networks (DNNs) models can be used in the problem of PPG signal classification and pulse rate estimation. In particular, we show that the DNN-based classification results correspond to parameters describing the PPG signals (e.g. peak energy in the frequency...

    Full text to download in external service

  • Measuring Pulse Rate with a Webcam

    In this paper a simple method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face images captured from a webcam. The desired signal is obtained by proper channel selection and principal component analysis. To determine the accuracy of the method an ECG signal is collected together with a video recordings. The effectiveness of the algorithm is considered...

    Full text to download in external service

  • Can we rely on the pulse transit time - pressure relationship - models comparison

    Publication

    An unobtrusive, noninvasive and continuous pressure measurement is invaluable however, still being under research and development. There are many attempts proposing an appropriate relationship between pulse pressure velocity and pressure. Fifteen different formulas, both theoretical and experimental, describing relation between blood pressure and crosssectional area of the vessel were examined. Using these formulas the relation...

    Full text to download in external service

  • Remote Estimation of Video-Based Vital Signs in Emotion Invocation Studies

    Abstract— The goal of this study is to examine the influence of various imitated and video invoked emotions on the vital signs (respiratory and pulse rates). We also perform an analysis of the possibility to extract signals from sequences acquired with cost-effective cameras. The preliminary results show that the respiratory rate allows for better separation of some emotions than the pulse rate, yet this relation highly depends...

    Full text available to download

  • Multi-pulse VSC arrangements with coupled reactors

    Publication

    - Year 2016

    This paper presents a novel approach to the multipulse VSC (Voltage Source Converter) arrangements based on several conventional inverter modules connected in parallel by using coupled reactors. This solution reduces the THD of the output voltage, despite the low switching frequency of transistors. The advantage of the proposed solution is also a relatively small rated power of the reactors. Proposed new arrangements for different...

    Full text to download in external service

  • Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.

    Publication

    - Frontiers of Optoelectronics - Year 2017

    In this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...

    Full text available to download

  • Digital Processing of Frequency–Pulse Signal in Measurement System

    Publication

    - Year 2018

    The work presents the issue of the use of multichannel measurement systems of sensors processing input value to impulse signal frequency. The frequency impulse signal obtained from such sensors is often required to be processed at the same time with a voltage signal which is obtained from other sensors used in the same measurement system. In such case, it is usually necessary to sample the output signals from all sensors in the...

    Full text available to download

  • Propagation of acoustic pulses in some fluids with yield stress

    Publication

    This study is devoted to the derivation of approximate equations governing acoustic pulses in flows with yieldstress, including some time-dependent flows with a slow dependence on time of yield stress and apparent viscosity. Themodeling of yield stress and apparent viscosity in the vicinity of a zero deformation rate allows us to consider a thixotropicfluid as a Bingham plastic with coefficients that are dependent on time. The...

    Full text available to download

  • New Architecture of Solid-State High-Voltage Pulse Generators

    Publication

    - ENERGIES - Year 2022

    The application of the nanosecond pulsed electric field (nsPEF) for biomedical treatments has gained more interest in recent decades due to the development of pulsed power technologies which provides the ability to control the electric field dose applied during tests. In this context, the proposed paper describes a new architecture of solid-state high-voltage pulse generators (SSHVPG) designed to generate fully customised sequences...

    Full text available to download

  • Cross-talk Between the Heart and Arteries in Older 65+ Adults

    Publication
    • T. Wierzba
    • S. Zajączkowski
    • P. Figarski
    • R. Olek
    • A. Poliński

    - Year 2019

    Regulatory synchronization between the heart and the arterial walls is essential for optimal blood delivery to tissues. We investigated functional coherence between heart rhythm and aortic wall compliance in 30 volunteers aged 65 – 74. ECG and carotid and iliac pulse-wave were recorded and digitized at 2 kHz. Carotid-femoral pulse-wave transit time (cfTT) which reflex aortic compliance was assessed using the intersecting tangent...

    Full text to download in external service

  • A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux

    Publication

    - ENERGIES - Year 2020

    In this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...

    Full text available to download

  • Control strategy for the multilevel cascaded H-bridge converter

    Publication

    - Year 2013

    The paper presents the control strategy for Cascaded H-bridge (CHB) converter . The converter output voltage using Space-Vector Pulse Width Modulation (SV-PWM) strategy is controlled. The DC-link voltages are controlled by appropriate choice of H-Bridges and appropriate choice of active and passive vectors.

    Full text to download in external service

  • A new duty cycles calculation method in pulse width modulation for direct matrix converters based on the shape function concept

    Publication

    - Year 2013

    Paper presents a new approach to duty cycle calculation in pulse width modulation for direct matrix converters. The essence of the proposed method is the use of elementary shape function of finite element. The algorithm for calculating the duty cycles was reduced to simple operations on the coordinates of input and output voltage vectors without trigonometric functions.

    Full text to download in external service

  • Enhanced Remote Control Providing Medical Functionalities

    This paper presents the enhanced remote control and its role in pervasive healthcare in the home. The device was equipped with health-related measurement modules and a message-processing unit. Preliminary results are presented for monitoring of a pulse, hand tremors, grip forces, and for self­ evaluation procedures. The interaction of the device with the smart environment is presented and discussed.

    Full text to download in external service

  • Pulse-Width Modulation Template for Five-Level Switch-Clamped H-Bridge-Based Cascaded Multilevel Inverter

    Publication

    - ENERGIES - Year 2021

    This article presents a carrier-based pulse-width modulation (PWM) template for a 5-level, H bridge-based cascaded multilevel inverter (MLI). The developed control concept generates adequate modulation template for this inverter topology wherein a sinusoidal modulating waveform is modified to fit in a single triangular carrier signal range. With this modulation approach, classical multiplicity and synchronization of the triangular...

    Full text available to download

  • Femtosecond Er-doped fiber laser source tunable from 872 to 1075 nm for two-photon vision studies in humans

    Publication
    • D. Stachowiak
    • M. J. Marzejon
    • J. Bogusławski
    • Z. Łaszczych
    • K. Komar
    • M. Wojtkowski
    • G. Soboń

    - Biomedical Optics Express - Year 2022

    We report the development of a widely-tunable femtosecond fiber laser system and its application for two-photon vision studies. The source is based on an Er-doped fiber laser with spectral shift up to 2150 nm, followed by a second harmonic generation module to generate a frequency-doubled beam tunable from 872 to 1075 nm. The source delivers sub-230 fs pulses with nearly-constant duration over the entire tuning range, with output...

    Full text available to download

  • Electrodeposited Biocoatings, Their Properties and Fabrication Technologies: A Review

    Publication

    Coatings deposited under an electric field are applied for the surface modification of biomaterials. This review is aimed to characterize the state-of-art in this area with an emphasis on the advantages and disadvantages of used methods, process determinants, and properties of coatings. Over 170 articles, published mainly during the last ten years, were chosen, and reviewed as the most representative. The most recent developments...

    Full text available to download

  • Studying the Effect of Working Conditions on WEDM Machining Performance of Super Alloy Inconel 617

    Publication

    Wire electrical discharge machining (WEDM) has been for many years a precise and efficient non-conventional manufacturing solution in various industrial applications, mostly involving the use of hard-to machine materials like, among other, the Inconel super alloys. The focus of the present study is on exploring the effect of selected control parameters, including pulse duration, pulse-off time and the dielectric flow pressure on...

    Full text available to download

  • Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier

    The paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18-pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism...

    Full text available to download

  • The data exchange between smart glasses and healthcare information systems using the HL7 FHIR standard

    Publication

    - Year 2016

    In this study we evaluated system architecture for the use of smart glasses as a viewer of information, as a source of medical data (vital sign measurements: temperature, pulse rate, and respiration rate), and as a filter of healthcare information. All activities were based on patient/device identification procedures using graphical markers or features based on visual appearance. The architecture and particular use cases were implemented...

    Full text to download in external service