Filters
total: 150
Search results for: STATIC PLATE LOAD TESTER
-
The electrical properties mesurements of DIR-SOFC with Ce0.8Fe0.2O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.8Fe0.1O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
The electrical properties mesurements of DIR-SOFC with Ce0.8Co0.2O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.8Co0.1O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
The electrical properties mesurements of DIR-SOFC with Ce0.8Mn0.2O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.8Mn0.1O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
The electrical properties mesurements of DIR-SOFC with Ce0.8Ni0.2O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.8Ni0.1O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
The electrical properties mesurements of DIR-SOFC with CeO2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with CeO2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
The electrical properties mesurements of DIR-SOFC with Ce0.8Cu0.2O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.8Cu0.1O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
Finite element models used in diagnostics of transverse cracks in bridge approach pavement
Open Research DataTransverse cracks in the asphalt pavement were observed on bridge structures next to single-module expansion joints with a 5 meter approach slab set at the depth of 1 m. The finite element (FE) models of the approach pavement were created to investigate the reasons of premature cracking and crack initiation mechanism over the back edge of the abutment...
-
A novel sandwich footbridge - Practical application of laminated composites in bridge design and in situ measurements of static response
PublicationA novel sandwich composite footbridge is presented in the paper, as an example of practical application of laminated composites in civil engineering. The in situ static load tests of the footbridge before its acceptation for exploitation are shown and discussed. The results are compared with the corresponding ones from a numerical equivalent single layer model of the sandwich structure created within the framework of finite element...
-
Mechanical Properties of Aluminium Bracket Strengthening
PublicationThe aim of the research is laboratory investigation of aluminium brackets employed to fasten lightweight curtain walls to building facilities. Tensile loads perpendicular to end plates (vertical) were applied here. The author focused on the solutions intended to increase the load-carrying capacity of aluminium brackets applying the plain washer form A (DIN 125; ISO 7089), plain washer with an outer diameter about 3d (DIN 9021;...
-
Behaviour of deformed steel columns exposed to impact load during earthquakes: numerical analysis
PublicationIt has been observed during earthquakes that the so called soft-storey failure of an upper floor of a building leads to considerable vertical impact load acting on structural members of the lower storeys. The aim of this paper is to investigate numerically the behaviour of horizontally deformed columns (deformation as the result of earthquake loading) that are additionally subjected to vertical impact load. In the first stage of...
-
Static Series and Shunt-series PE Voltage-quality Controllers
PublicationAs presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...
-
Effect of pavement roughness and vehicle dynamic loads on decrease of fatigue life of flexible pavements
PublicationDue to the fact that pavement surfaces are not ideally even, dynamic loads of vehicle axles deviate from static loads. Higher dynamic loads contribute to faster pavement distress. The distribution of dynamic loads is similar to normal distribution and can be described by static load and factors DI (dynamic impact) and DLC (dynamic load coefficient). With the deterioration of pavement condition its evenness decreases as well and...
-
Direct design of Controlled Modulus Columns (CMC) based on in-situ testing
PublicationIn this paper, the serviceability limit state and bearing capacity of tension screw displacement piles were analyzed using the results of static pile load tests, carried out on the test plot near the Elbląg city, and field, and laboratory tests. The paper presents the methodology of determining the pile load-settlement curve using different types of t-z transfer functions. The new method of constructing the pile load-settlement...
-
FEM modelling of screw displacement pile interaction with subsoil
PublicationPredicting the-settlement characteristics of piles is an important element in the designing of pile foundations. The most reliable method in evaluating pile-soil interaction is the static load test, preferably performed with instrumentation for measuring shaft and pile base resistances. This, however, is a mostly post-implementation test. In the design phase, prediction methods are needed, in which numerical simulations play an...
-
Thermo-resonance analysis of an excited graphene sheet using a new approach
PublicationForced vibration of graphene nanoplate based on a refined plate theory in conjunction with higher-order nonlocal strain gradient theory in the thermal environment has been investigated. Regarding the higher-order nonlocal strain gradient theory, both stress nonlocality and size-dependent effects are taken into account, so the equilibrium equations which are governing on the graphene sheet have been formulated by the theory....
-
Stability of a truss under upward wind loading
PublicationThe present paper is devoted to the numerical investigations of stability of a truss under upward wind load. The truss is braced at its the upper cord. A structural variant including lateral braces, or lateral and torsional braces is considered. The research presents the problems of linear buckling and non-linear static analysis of the truss shell and beam model with geometric and material non-linearity are presented. The initial...
-
The use of plate springs for preloading of a system of tapered roller bearings of a wind turbine gearbox
PublicationThe use of preloaded tapered roller bearings in wind turbine drive systems allows a transfer of load in the case of high variations of axial forces. The examined bearing system, a modification of a current design, consists of a pair of different sized bearings. Previous study showed the high sensitivity of tapered roller bearings on the existing radial interference. Dimensional tolerances used in the original design do not allow...
-
Load Tests of the Movable Footbridge Over the Port Canal in Ustka
PublicationThe paper presents the acceptance tests carried out on the open footbridge over the port canal in the Port of Ustka. The steel footbridge construction is created by a single pylon to which a movable truss span is suspended with a theoretical span of 52.3 m. The studies about load test of the object included static and dynamic extortion and measurements. In static tests the ballast was of pallets with concrete blocks. Dynamic studies...
-
Mechanizm współpracy z gruntem pali prefabrykowanych wbijanych w świetle próbnych obciążeń pali oprzyrządowanych
PublicationOpis badań i wyniki próbnych obciążeń statycznych dwóch pali prefabrykowanych wbijanych oprzyrządowanych w aparaturę do pomiaru rozkładu siły osiowej wzdłuż trzonu pala. Analiza wpływu czasu i procesu wbijania na charakterystykę osiadania pali prefabrykowanych wbijanych. Identyfikacja siły rezydualnej w palu prefabrykowanym wbijanym i jej wpływ na interpretację pomiarów ekstensometrycznych w próbnym obciążeniu pala. Wnioski na...
-
REINFORCED CONCRETE SUPPORTING CONSTRUCTION OF THE STADIUM COVER FOR EURO 2012 IN GDAŃSK
PublicationIn the article structural issues that connected with the reinforced concrete supporting construction of the stadium roofing for EURO 2012 in Gdańsk were described. In the first part of the article the concept of stadium foundation were described. In the second the static - strength analysis for two variants fastening together individual foundation elements were made. The two assumed geometrically different concept of foundation...
-
Reliability of Corroded Stiffened Plate Subjected to Uniaxial Compressive Loading
PublicationThe work is focused on the reliability of corroded stiffened plates subjected to compressive uniaxial load based on the progressive collapse approach as stipulated by the Common Structural Rules for Bulk Carriers and Oil Tankers, employing the limit state design. Two different cases have been investigated. In the first model, the corrosion degradation led to uniform thickness loss, whereas the mechanical properties were unchanged,...
-
Displacements of bones during bending test of first metatarsophalangeal joint after arthrodesis with medially or dorsally positioned locking plate and lag screw.
Open Research DataThe Dataset contains the values of displacements of bone control points during the bending test of first metatarsophalangeal (MTP1) joint specimens after arthrodesis.
-
Nonlocalized thermal behavior of rotating micromachined beams under dynamic and thermodynamic loads
PublicationRotating micromachined beams are one of the most practical devices with several applications from power generation to aerospace industries. Moreover, recent advances in micromachining technology have led to huge interests in fabricating miniature turbines, gyroscopes and microsensors thanks to their high quality/reliability performances. To this end, this article is organized to examine the axial dynamic reaction of a rotating...
-
Stan awaryjny wiaduktu kolejowego w Bydgoszczy
PublicationW pracy przedstawiono opis stanu awaryjnego wiaduktu kolejowego. Omówiono wyniki badań in situ oraz teoretycznych analiz statyczno-wytrzymałościowych ponad 100-letniego obiektu. Przedstawiono wnioski i zalecenia dotyczące doraźnego zabezpieczenia obiektu oraz warunki jego dalszej eksploatacji.
-
Stan awaryjny wiaduktu kolejowego w Bydgoszczy
PublicationW pracy przedstawiono opis stanu awaryjnego wiaduktu kolejowego. Omówiono wyniki badań in situ oraz teoretycznych analiz statyczno-wytrzymałościowych ponad 100-letniego obiektu. Przedstawiono wnioski i zalecenia dotyczące doraźnego zabezpieczenia obiektu oraz warunki jego dalszej eksploatacji.
-
Numerical analysis of pile installation effects in cohesive soils
PublicationIn this thesis the empirical equation for radial effective stress calculation after displacement pile installation and following consolidation phase has been proposed. The equation is based on the numerical studies performed with Updated Lagrangian, Arbitrary Lagrangian-Eulerian and Coupled Eulerian-Lagrangian formulations as well as the calibration procedure with database containing world-wide 30 pile static loading tests in cohesive...
-
Load-settlement characteristics of piles working in a group
PublicationLoad-settlement characteristic (Q-s) of an axially loaded pile can be empirically determined from a static pile load test or on the basis of calculations using, e.g. transfer functions or numerical methods (FEM). The transfer functions method usually rely on empirical data, i.e. the function parameters are determined on the basis of numerous pile test results. Thus this method takes into account pile installation technology and...
-
Stability and load bearing capacity of a truss with elastic braces
PublicationThe present paper is devoted to the numerical and experimental investigations of stability of a truss stiffened by elastic braces. The model of a real roof truss scaled by factor ¼ was investigated. In the research the linear buckling and non-linear static analysis of the truss shell and beam model with geometric and material non-linearity is presented. The initial imperfections were assumed in the form of the first buckling mode....
-
Przyczółki mostowe wspomagane konstrukcjami z gruntu zbrojonego
PublicationW referacie przedstawiono syntezę prac związanych z oceną projektów przyczółków wykorzystujących odciążenie w postaci konstrukcji z gruntu zbrojonego geosyntetykami, realizowanych na drogach ekspresowych S3 i S7. W ramach przeprowadzonych audytów dokonano oceny zastosowanych rozwiązań szczegółowych i materiałów jak również obliczeń zamieszczonych w projektach. Zwrócono szczególną uwagę na przestrzenną prace bloków z gruntu zbrojonego...
-
Computational modelling of historic masonry railroad arch bridges
PublicationThe problems encountered during the analyzes of structural response of historic masonry railroad arch bridges are described in this paper. The attention is mainly focused on the stiffness of the masonry arches, their strengths and appropriate estimation of railroad load intensity. Issues related to computational modelling of two, existing, almost 130 years old masonry arch railroad bridges are presented in this context. The main...
-
Damage detection in a bolted lap joint using guided waves
PublicationThe paper presents the experimental investigation of guided waves application to the condition assessment of prestressed bolted connections and a concept of new quantitative indicator. The main goal of the research was the analysis of the influence of the contact conditions changes to the characteristics of a propagating disturbance. The experimental tests were carried out for a single bolted lap joint. The excitation and acquisition...
-
BADANIA KOMPOZYTOWEGO MOSTU DLA PIESZYCH
PublicationThe paper presents in situ load testing of the innovative footbridge of FOBRIDGE grant mounted at Gdansk University of Technology. The span of composite sandwich structure (GFRP skins, PET core) and the scope of static and dynamic tests are presented. The selected, representative results of in situ measurements and data obtained from the SHM monitoring system are discussed. Besides the standard testing procedures on the full scale...
-
Load effect impact on the exploitation of concrete machine foundations used in the gas and oil industry
PublicationMachine foundations is a critical topic in the gas and oil industry, which design and exploitation require extensive technical knowledge. Machine foundations are the constructions which are intended for mounting on it a specific type of machine. The foundation has to transfer dynamic and static load from machine to the ground. The primary difference between machine foundations and building foundations is that the machine foundations...
-
Stability and load bearing capacity of a braced truss under upward wind loading
PublicationThe paper is focused on the numerical and experimental investigation of stability of a steel truss under upward wind loading. The structure was stiffened by elastic braces situated at the top and bottom chord. Usually the lateral (translational) brace stiffness is considered. However, the rotational stiffness of braces caused by interaction between torsional stiffness of the truss top chord and bending stiffness of the roof elements...
-
Stability and load bearing capacity of a braced truss under upward wind loading
PublicationThe paper is focused on the numerical and experimental investigation of stability of a steel truss under upward wind loading. The structure was stiffened by elastic braces situated at the top and bottom chord. Usually the lateral (translational) brace stiffness is considered. However, the rotational stiffness of braces caused by interaction between torsional stiffness of the truss top chord and bending stiffness of the roof elements...
-
Investigation of stability and limit load of a truss overhead opened bridge
PublicationThe paper presents selected methods of determining stability and limit load of a truss top chord in opened bridges. These methods include linear buckling and non-linear static analysis based on the finite element method and algorithms based on design code procedures. The described methods were tested on an example of a steel footbridge situated in Straszyn. The results of stability analysis are compared. The results of geometrical...
-
Numerical analysis on axial capacity of steel built-up battened columns
PublicationThis paper deals with the numerical analysis aimed at study the bearing capacity of pinended steel built-up columns under axial compression. Finite element (FE) models were performed for the columns presented in the literature. The main problem discussed in the article is the shape and magnitude of geometric imperfections introduced into the numerical FE model, necessary to obtain the load capacity consistent with the experimental...
-
Static Shunt PE Voltage-Quality Controllers
PublicationThis chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...
-
Stability of an imperfect truss loaded by wind
PublicationThe present paper is devoted to the numerical research of stability of a truss loaded by wind and stiffened by elastic supports located at the top chord. The lateral braces or lateral and torsional braces were taken into account. In this paper, the linear buckling analysis re- sults for the beam and shell model were presented. Two different shapes of initial geometric imperfections were considered in the non-linear static analysis...
-
Shaft friction from the DMT and direct shear interface tests
PublicationThe article presents preliminary attempt to create tri-linear transfer curves for describing pile behaviour under axial loading. Transfer curves would use the parameter measured in dilatometer test, particularly a constrained modulus MDMT. The proposed method is based on concrete rough and smooth interface tests performed in a direct shear apparatus. Based on the obtained mobilization curves, relationships were created between...
-
Application of the ‘CPT 2012’model of AFNOR standard for column design in Poland–Jazowa case study
Publicationhis paper presents the ‘CPT 2012’ model incorporated into the AFNOR NF P94-262:2012-07, French standard for pile design fully compatible with Eurocode 7, to the wider Polish audience. The bearing capacity of three reference columns for Vistula Marshlands have been calculated according to ‘CPT 2012’ model and AFNOR recommendations. Then, the design resistances have been compared with ultimate column bearing capacity measured during...
-
Nuclear Power Plant Steam Turbine - Modeling for Model Based Control Purposes
PublicationThe nature of the processes taking place in a nuclear power plant (NPP) steam turbine is the reason why their modeling is very difficult, especially when the model is intended to be used for on-line optimal model based process control over a wide range of operating conditions, caused by changing electrical power demand e.g. when combined heat and power mode of work is utilized. The paper presents three nonlinear models of NPP steam...
-
Instrumented end notched flexure - Crack propagation and process zonemonitoring Part II: Data reduction and experimental
PublicationA mode II instrumented end notched flexure three point bending (ENF) adhesion test is described. The adhesive joint consists of two aluminium alloy (AW7075-T6) plates bonded with a structural epoxy adhesive (Hysol EA 9395™). Strain gauges are attached to the outer surface (backface) of the substrates in the lengthwise direction to measure local surface strain during crack propagation. Simultaneously, load/displacement measurements...
-
Consideration of dynamic loads in the determination of axle load spectra for pavement design
PublicationAxle load spectra constitute a crucial part of the data for pavement design and pavement distress analysis. Typically, axle load spectra represent static load from vehicles and do not include dynamic loads generated by vehicles in motion. While dynamic loads can significantly contribute to faster pavement distress, this fact is mostly omitted in pavement design methods. The paper presents a methodology for consideration of dynamic...
-
Stability and limit load analysis of a cold-formed channel section column
PublicationThe paper presents stability and limit load analysis of a steel column 1440 mm high of a cold-formed channel section, subjected to a combination of compression and bending. Experimental results were compared to the resistance of a code procedure and to the outcome of numerical non-linear analysis. Comparison was made of numerical solutions by means of static (Riks) and dynamic (Explicit and Implicit) methods. Perfectly elastic...
-
STABILITY AND LOAD BEARING CAPACITY OF A BARS WITH BUILT UP CROSS SECTION AND ELASTIC SUPPORTS
PublicationThe present paper is devoted to the numerical analysis and experimental tests of compressed bars with built–up cross section which are commonly used as a top chord of the roof trusses. The significant impact on carrying capacity for that kind of elements in case of out-of-plane buckling is appropriate choice of battens which are used to provide interaction between separate members. Linear buckling analysis results and nonlinear static...
-
Experimental ultimate strength assessment of stiffened plates subjected to marine immersed corrosion
PublicationThis study experimentally analyses the impact of marine immersed corrosion degradation on the compressive strength of the stiffened plates where the lower degradation levels were considered. The corrosion degradation test was accelerated by controlling the natural corrosion environmental factors, avoiding applying an electric current. Different groups of corrosion degradation levels and initial plate thicknesses were investigated....
-
INFLUENCE OF TIME ON THE BEARING CAPACITY OF PRECAST PILES
PublicationOne of the most popular types of foundations in layered subsoil with very differentiated soil shear strengths are precast piles. One of the reasons is a fact that we can well control the driving process during the installation of these piles. The principles of the assessment of bearing capacity and settlements of the piles given by Eurocode 7, concentrate on two main methods, i.e. Static Pile Load Tests (SPLT) and Dynamic Driving...
-
The mechanism of grouting action under the base of bored pile
PublicationThe grouting under the base of bored pile is carried out in order to reduce pile settlement and improve its bearing capacity. The principal aim of grouting is to introduce an initial force between the soil and the pile base. In non-cohesive soil, the grouting can also enlarge the pile base area and therefore improve the base resistance. The example of static load tests on instrumented bored piles installed with and without grouting...
-
ANALYSIS OF BEARING CLEARANCE AND WIDTH OF OIL GROOVE ON CHARACTERISTIC OF FLUID FILM IN HYDRODYNAMIC MAIN CRANKSHAFT BEARINGS
PublicationAbstract Paper represents analysis of influence of oil groove width and bearing clearance on characteristics of oil film in hydrodynamic journal main crankshaft bearing. Analysis was performed in purpose to define influence of bearing clearance and dimensions of oil groove on static characteristics and manufacturability of half shelf bearings in industrial high-volume production. Computer simulations was made using ARTbear program...