Search results for: TRAVELING FAULT ARC
-
Selected problems of earth fault loop impedance testing in circuits fed from UPS
PublicationIn the paper a principle of earth fault loop impedance testing in low voltage systems has been presented. Selected factors, influencing accuracy of the testing, are indicated. A structure of UPS of VFI-type and the problem of impedance testing in circuits with such type of UPS are discussed.
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Open-Phase Fault Detection Method for Sensorless Five-Phase Induction Motor Drives with an Inverter Output Filter
PublicationThe paper presents the sensorless five-phase induction motor drive implementation with an inverter output filter with third harmonic injection. For the sensorless operation, the required observers are presented for the first and third harmonics with consideration of the inverter output filter. Moreover, the interaction of the observers and the control system is capable to handle a deactivation of one or two phases, which improves...
-
Arc Ignition Process in Short Fuses Element
PublicationPrzedstawiono wyniki badań zapłonu łuku elektrycznego w topiku w warunkach dużej stromości narastania gęstości prądu, do 5.19 9 A s-1 mm-2. Wyznaczono podziałkę rozpadu topika (0,04-0,12 mm) oraz napięcie zapłonu na elementarnej przerwie topika (20-30 V). Wykazano w badaniach doświadczalnych modelu fizycznego topika rozpad i ponowne łączenie sąsiednich elementarnych przerw.
-
Sensorless Fault Detection of Induction Motor with Inverter Output Filter
PublicationThe paper presents the problem of monitoring and fault detection of a sensorless voltage inverter fed squirrel cage induction motor with LC filter. The detection is based on load torque estimation of the investigated torque transmission system. The load torque is calculated besides the computation of other variables that are mandatory for sensorless drive operation such as rotor flux and speed. The implemented LC filter smooths...
-
Degradation of Kinematic PPP of GNSS Stations in Central Europe Caused by Medium-Scale Traveling Ionospheric Disturbances During the St. Patrick’s Day 2015 Geomagnetic Storm
PublicationIn solar cycle 24, the strongest geomagnetic storm took place on March 17, 2015, when the geomagnetic activity index was as high as -223 nT. To verify the impact that the storm had on the Global Navigation Satellite System (GNSS)’s positioning accuracy and precision, we used 30-s observations from 15 reference stations located in Central Europe. For each of them, we applied kinematic precise point positioning (PPP) using gLAB software...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublicationA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Fault tolerant guarding of grids
PublicationW pracy rozważano problem strzeżenia krat dwuwymiarowych przez dwa niezależne zespoły straży. Wykazano, że zagadnienie minimalizacyjne jest NP-trudne i zaproponowano dla niego wielomianowy algorytm 6/5-przybliżony.
-
Analog fault signature based on sigma-delta modulation and oscillation-test methodology.
PublicationW artykule dokonano przeglądu prac z zakresu testowania układów elektronicznych metodą oscylacyjną. Wskazując na niedostatki aktualnie stosowanej techniki testowania oscylacyjnego zaproponowano nową sygnaturę uszkodzeń dla układów analogowych. Proponowany parametr diagnostyczny jest wydobywany z odpowiedzi czasowej oscylatora testującego, w układzie złożonym z detektora szczytowego, modulatora sigma-delta oraz licznika rewersyjnego....
-
Sensorless field oriented control for five-phase induction motors with third harmonic injection and fault insensitive feature
PublicationThe paper presents a solution for sensorless field oriented control (FOC) system for five-phase induction motors with improved rotor flux pattern. In order to obtain the advantages of a third harmonic injection with a quasi-trapezoidal flux shape, two vector models, α1–β1 and α3–β3, were transformed into d1– q1, d3– q3 rotating frames, which correlate to the 1st and 3rd harmonic plane respectively. A linearization approach of the...
-
Kinetics of Intermetallic Phase Precipitation in Manual Metal Arc Welded Duplex Stainless Steels
PublicationThe article presents the influence of heat treatment on the kinetics of transformations in lean duplex LDX2101 steel and a weld made of standard duplex 2209 material, which was welded by manual metal arc welding. Changes in the microstructure, hardness, and magnetic phase content were analyzed after heat treatment was conducted at a temperature of 800 °C for a period ranging from 15 to 1440 min. Light and scanning microscopy, Vickers...
-
Novel Investigation of Higher Order Spectral Technologies for Fault Diagnosis of Motor-Based Rotating Machinery
PublicationIn the last decade, research centered around the fault diagnosis of rotating machinery using non-contact techniques has been significantly on the rise. For the first time worldwide, innovative techniques for the diagnosis of rotating machinery, based on electrical motors, including generic, nonlinear, higher-order cross-correlations of spectral moduli of the third and fourth order (CCSM3 and CCSM4, respectively), have been comprehensively...
-
Effect of water salinity on properties of multipass underwater wet manual metal arc welded joints
PublicationThe weldability of steel under the water is limited due to the influence of the environment. Water causes limited visibility, presence of the residual stresses, increasing the cooling rate, and increasing the diffusible hydrogen content in deposited metal, leading to the formation of brittle microstructures in heat-affected zone (HAZ). The paper presents the results of mechanical properties testing of S420G2+M steel welded joints...
-
Fault detection and diagnostics of complex dynamic systems using Gaussian Process Models - nuclear power plant case study
PublicationThe article examines the use of Gaussian Process Models to simulate the dynamic processes of a Pressurized Water nuclear Reactor for fault detection and diagnostics. The paper illustrates the potential of Gaussian Process Models as a tool for monitoring and predicting various fault conditions in Pressurized Water nuclear Reactor power plants, including reactor coolant flow and temperature variations, deviations from nominal working...
-
Large‐Scale Traveling Ionospheric Disturbances Over the European Sector During the Geomagnetic Storm on March 23–24, 2023: Energy Deposition in the Source Regions and the Propagation Characteristics
PublicationMultiple Large-Scale Traveling Ionospheric Disturbances (LSTIDs) are observed in the European sector in both day-time and night-time during the magnetic storm on March 23–24, 2023. The Total Electron Content (TEC) observation from a network of GNSS receivers shows the propagation of LSTIDs with amplitudes between around 0.5 and 1 TECU originating from auroral and polar cusp regions down to southern Europe (35°N) with velocities...
-
Easy and hard instances of arc ranking in directed graphs
PublicationArtykuł dotyczy uporządkowanego kolorowania łuków grafów skierowanych. Problem polega na takim przyporządkowaniu liczb łukom digrafu, aby każda skierowana ścieżka łącząca dwa łuki o tej samej liczbie (kolorze) zawierała łuk o kolorze wyższym. Praca podaje liniowy optymalny algorytm dla pewnego szczególnego przypadku, oraz zawiera dowód, iż problem ten jest obliczeniowo trudny dla 3-dzielnych acyklicznych digrafów i stałej liczby...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Evolution of magnetic and transport properties in (Cr1−xMnx)2AlC MAX-phase synthesized by arc melting technique
PublicationHerein we initiate a comeback to the arc melting technique to produce MAX-phase solid solutions. Bulk samples of (Cr1−xMnx)2AlC MAX-phase with X = 0, 0.025, 0.05 and 0.1 were synthesized and studied by means of X-ray diffractometry, scanning electron microscopy in combination with energy-dispersive X-ray spectroscopy. Samples were established to be homogeneous with an incorporation of Cr7C3, AlCr2 and Al2O3 secondary phases which...
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Fault detection in the marine engine using a support vector data description method
PublicationFast detection and correct diagnosis of any engine condition changes are essential elements of safety andenvironmental protection. Many diagnostic algorithms significantly improve the detection of malfunctions.Studies on diagnostic methods are rarely reported and even less implemented in the marine engine industry.To fill this gap, this paper presents the Support Vector Data Description (SVDD) method as applied to thefault detection...
-
Data-driven models for fault detection using kernel pca:a water distribution system case study
PublicationKernel Principal Component Analysis (KPCA), an example of machine learning, can be considered a non-linear extension of the PCA method. While various applications of KPCA are known, this paper explores the possibility to use it for building a data-driven model of a non-linear system-the water distribution system of the Chojnice town (Poland). This model is utilised for fault detection with the emphasis on water leakage detection....
-
Speed sensorless ac drive with inverter output filter and fault detection using load torque signal
PublicationIn this paper, a sensorless induction motor (IM) drive using speed observer system is presented. The system includes load torque computation for gear fault detection. Nonlinear control method is adopted for controlling the motor over a wide speed range. An LC filter for smoothing current and voltage waveforms is used at the output of the voltage inverter. The use of filter imposes more building of the used observer to avoid using...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublicationVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Influence of Ultrasound on the Characteristics of CaP Coatings Generated Via the Micro-arc Oxidation Process in Relation to Biomedical Engineering
PublicationOver the past decade, bone tissue engineering has been at the core of attention because of an increasing number of implant surgeries. The purpose of this study was to obtain coatings on titanium (Ti) implants with improved properties in terms of biomedical applications and to investigate the effect of ultrasound (US) on these properties during the micro-arc oxidation (MAO) process. The influence of various process parameters, such...
-
Fault diagnosis of marine 4-stroke diesel engines using a one-vs-one extreme learning ensemble
PublicationThis paper proposes a novel approach for intelligent fault diagnosis for stroke Diesel marine engines, which are commonly used in on-road and marine transportation. The safety and reliability of a ship's work rely strongly on the performance of such an engine; therefore, early detection of any type of failure that affects the engine is of crucial importance. Automatic diagnostic systems are of special importance because they can...
-
Speed Sensorless AC Drive with Inverter LC Filter and Fault Detection Using Load Torque Signal
PublicationThe industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve...
-
Fault detection in measuring systems of power plants
PublicationThis paper describes possibility of forming diagnostic relations based on application of the artifical neural networks (ANNs), intended for the identifying of degradation of measuring instruments used in developed power systems. As an example a steam turbine high-power plant was used. And, simulative calculations were applied to forming diagnostic neural relations. Both degradation of the measuring instruments and simultaneously...
-
Tool support for ECSDM fault tree methodology
PublicationExtended Common Safety Description Model (ECSDM) jest językiem do formalnej specyfikacji systemów związanych z bezpieczeństwem oraz ich komponentów. Język ten zawiera konstrukcje umożliwiające specyfikację zależności czasowych. Może on zostać użyty w analizie drzew błędów, aby uzyskać jednoznaczną specyfikację hazardów w sytuacji, gdy są one uzależnione od związków czasowych pomiędzy przyczynami. Artykuł opisuje narzędzie wytworzone...
-
Modelling of axial magnetic field effect on electric arc in ablation capillaries
PublicationBadano wpływ osiowego pola magnetycznego na łuk elektryczny w kapilarze ablacyjnej o średnicy do 3 mm. Wyniki porównywano z kapilarą ceramiczną. Łuk zasilany był z baterii kondensatorów prądem do około 1200 A. Stosowano pole magnetyczne wolnozmienne oraz wysokoczęstotliwościowe o indukcji do 10 T. Stwierdzono nawet 3-krotny wzrost napięcia łukowego pod wpływem osiowego pola magnetycznego w kapilarze gazującej, przy braku reakcji...
-
Conditioning scenarios on regional impact assessment of the Via Hanseatica zone (the Sapphire Arc).
PublicationPraca zawiera cztery scenariusze rozwoju regionalnego strefy wokół drogi Via Hanseatica (Szczecin-gdańsk-Kaliningrad). Scenariusze służą jako podstawa oceny oddziaływań regionalnych (impact essessment) drogi.
-
Effects of Micro-Arc Oxidation Process Parameters on Characteristics of Calcium-Phosphate Containing Oxide Layers on the Selective Laser Melted Ti13Zr13Nb Alloy
PublicationTitania-based films on selective laser melted Ti13Zr13Nb have been formed by micro-arc oxidation (MAO) at different process parameters (voltage, current, processing time) in order to evaluate the impact of MAO process parameters in calcium and phosphate (Ca + P) containing electrolyte on surface characteristic, early-stage bioactivity, nanomechanical properties, and adhesion between the oxide coatings and substrate. The surface...
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublicationThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Evolution-based scheduling of fault-tolerant programs on multiple processors
Publication -
Sub-optimal fault-tolerant control by means of discrete optimization
PublicationOpracowanie przedstawia metodę projektowania sterowania optymalnego i odpornego na uszkodzenia z zastosowaniem algorytmów optymalizacji dyskretnej. Poszukiwana trajektoria, jeśli istnieje, jest reprezentowana przez najtańszą ścieżkę w grafie przepływowym, kodującym właściwości danego procesu dynamicznego. Metoda umożliwia zdefiniowanie obszarów zastrzeżonych dla punktu pracy, mogących reprezentować uszkodzenia systemu wykryte wcześniej.
-
Sub-optimal fault-tolerant control with the use of discrete optimization
PublicationW pracy prezentuje się koncepcję projektowania układów sterowania z tolerancją usterek poprzez zastosowanie podejścia suboptymalnego. Przyjąwszy przestrzenno-stanową reprezentację nieliniowego procesu dynamicznego we wstępnej fazie projektowania (off-line) poszukuje się optymalnej trajektorii punktu pracy w przestrzeni stanu (ograniczanej do pewnej przestrzeni roboczej). Na poszukiwaną trajektorię można łatwo narzucać dowolne ograniczenia,...
-
Fault diagnosis of analog piecewise linear circuits based on homotopy
PublicationArtykuł opisuje weryfikację metodą diagnostyki analogowych układów odcinkowo-liniowych opartą na podejściu homotopijnym. Homotopia przekształca jedną funkcję f(x) w inną funkcję g(x) poprzez zmianę parametru homotopii tî[0,1]. Ścieżka homotopijna pokazuje drogę od punktu x0 z dziedziny funkcji f(x) do odpowiadającego mu punktu x* funkcji g(x). Idea metody zakłada wykorzystanie funkcji f(x) do opisu diagnozowanego układu w stanie...
-
Test limitations induced by fault-driven instability of analog circuits.
PublicationCelem pracy jest ocena ograniczeń testowania uszkodzeń parametrycznych wynikajacych z utraty stabilności przez testowany układ analogowy. Zastosowano metody zapożyczone z teorii sterowania: liniową transformacje frakcyjną i analizę metodą strukturalnych wartości szczególnych. Przykładowej analizie poddano filtr typu leapfrog. Do obliczeń wykorzystano środowisko Matlab/Simulink. Wyniki obliczeń wykazały dużą podatność testowanego...
-
A Low-Profile Metal-backed Dipole Loaded with Closely Coupled Arc-shaped Open Stubs for On-metal Tag Design with Wide Frequency Tuning Capability
PublicationThis research has presented a single-layer metal-backed dipole antenna, which consists of a feedline loaded with two pairs of closely-coupled arc-shaped open stubs, for designing a metal-mountable tag that features tuning capability over a wide range of frequency. Here, the stubs can generate sufficient inductive reactance for bringing down the tag resonant frequency tunable in both the regulated UHF RFID passbands (North American...
-
A method of fault diagnosis of analog parts of electronic embedded systems with tolerances
PublicationPrzedstawiono nową metodę detekcji i lokalizacji uszkodzeń w częściach analogowych z tolerancjami elementów nieuszkodzonych mieszanych sygnałowo elektronicznych systemów wbudowanych sterowanych mikrokontrolerami. Metoda składa się z trzech etapów. W pierwszym etapie tworzony jest słownik uszkodzeń przez aproksymację rodziny pasów lokalizacyjnych. W etapie pomiarowym wewnętrzny licznik mikrokontrolera mierzy czasy trwania impulsów...
-
The effect of earth fault current harmonics on tripping of residual current devices
PublicationSzerokie zastosowanie przekształtników, a w szczególności przemienników częstotliwości sprawia, że wyłączniki różnicowoprądowe znajdują się w obwodach, w których może płynąć odkształcony prąd ziemnozwarciowy. Prąd ziemnozwarciowy w obwodach z przemiennikami częstotliwości zawiera harmoniczne, których rząd głównie zależy od częstotliwości PWM. Odkształcony prąd wpływa na poprawne wyzwalanie wyłączników różnicowoprądowych. W artykule...
-
Modelling of soft fault propagation in sequential circuits by fuzzy-logic simulations
Publication -
An application of the TCRBF neural network in multi-node fault diagnosis method
PublicationPrzedstawiono nową metodę samo-testowania części analogowej w systemach elektronicznych sterowanych mikrokontrolerami. Układ badany pobudzany jest przebiegiem sinusoidalnym przez generator zamontowany w systemie, a jego odpowiedź jest próbkowana w wybranych węzłach przez wewnętrzny przetwornik A/C mikrokontrolera. Detekcja i lokalizacja uszkodzenia jest dokontwana przez sieć neuronową typu TCRBF. Procedurę diagnostyczną zaimplementowano...
-
A CUSUM-Based Approach for Condition Monitoring and Fault Diagnosis of Wind Turbines
Publication -
A neural network based system for soft fault diagnosis in electronic circuits
PublicationW artykule przedstawiono system do diagnostyki uszkodzeń parametrycznych w układach elektronicznych. W systemie zaimplementowano słownikową metodę lokalizacji uszkodzeń, bazującą na pomiarach w dziedzinie częstotliwości przeprowadzanych za pomocą analizatora transmitancji HP4192A. Rozważono główne etapy projektowania systemu: definiowanie modelu uszkodzeń, wybór optymalnych częstotliwosci pomiarowych, ekstrakcję cech diagnostycznych,...
-
Zdzisław Kowalczuk prof. dr hab. inż.
PeopleZdzislaw Kowalczuk received his M.Sc. degree in 1978 and Ph.D. degree in 1986, both in Automatic Control from Technical University of Gdańsk (TUG), Gdańsk, Poland. In 1993 he received his D.Sc. degree (Dr Habilitus) in Automatic Control from Silesian Technical University, Gliwice, Poland, and the title of Professor from the President of Poland in 2003. Since 1978 he has been with Faculty of Electronics, Telecommunications and Informatics...
-
Development of an Oxide Layer on Al 6061 Using Plasma Arc Electrolytic Oxidation in Silicate-Based Electrolyte
Publication -
Diagnosis of fully differential circuits based on a fault dictionary implemented in the microcontroller systems
PublicationPrzedstawiono nową koncepcję testera wbudowanego bist przeznaczonego do diagnostyki w pełni różnicowych układów analogowych implementowanych w mikrosystemach mieszanych sygnałowo. w trakcie testowania mierzona jest amplituda i faza wyjściowego napięcia różnicowego. procedura detekcji i lokalizacji uszkodzeń bazuje na słowniku uszkodzeń przechowywanym w pamięci programu mikrokontrolera. korzystną cechą przestrzeni pomiarowej wyznaczonej...
-
Implementation of DEIS for reliable fault monitoring and detection in PEMFC single cells and stacks
PublicationDynamic Electrochemical Impedance Spectroscopy (DEIS) was presented as novel method for diagnostic and monitoring of PEMFC stack and single cells operation. Impedance characteristics were obtained simultaneously with current - voltage characteristics for stack and each individual cell. Impedance measurements were performed in galvanodynamic mode. It allowed to compare performance of each cell and identification of faulty cell operation...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublicationPrzedstawiono nową metodę detekcji i lokalizacji uszkodzeń polegających na braku przewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne. Metoda jest rozszerzeniem, opracowanej wcześniej, metody wykorzystującej znormalizowane składowe stałe prądów obciążenia. Znormalizowane wartości średnie prądów powiązano z dodatkowymi wskaźnikami diagnostycznymi, które zawierają informacje o czasie trwania nieprzewodzenia...