Temperature Fiber-Optic Sensor with ZnO ALD Coating
PublikacjaThis study presents a microsphere-based fiber-optic sensor with a ZnO Atomic Layer Deposition (ALD) coating thickness of 100 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range of 100 °C to 300 °C, with a 10 °C step. An interferometric signal is used to control whether the microstructure is whole. Spectrum shift of a reflected signal is used to ascertain changes in...
-
Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air
PublikacjaThe paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs) in outdoor and indoor air. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric), photoionization and semiconductor with solid electrolyte ones....
-
An analytical hierarchy process for selection of the optimal procedure for resveratrol determination in wine samples
PublikacjaThe study shows the application of analytical hierarchy process (AHP) in ranking the analytical procedures, that are applied for resveratrol determination in wine samples. 19 different analytical methodologies are described by metrological, economic and environmental criteria, that are further divided into 10 subcriteria. Before AHP application, the amount of input data is decreased with cluster analysis. The first run of AHP is...
-
Multicriteria decision analysis in ranking of analytical procedures for aldrin determination in water
PublikacjaThe study presents the possibility of multi-criteria decision analysis (MCDA) application when choosing analytical procedures with low environmental impact. A type of MCDA, Preference Ranking Organization Method for Enrichment Evaluations (PROMETHEE), was chosen as versatile tool that meets all the analytical chemists – decision makers requirements. Twenty five analytical procedures for aldrin determination in water samples (as...
-
Emerging strategies for enhancing detection of explosives by artificial olfaction
PublikacjaExplosives detection systems need to be able to reliably detect a wide range of explosive materials and their vapours. The continued development and improvement of artificial olfaction techniques, including electronic nose (EN), remains important to overcome existing challenges and meet requirements posed by new improvements in the field of explosives. There is an increasingly popular trend aimed at improvement of fundamental metrological...
-
Application of deep eutectic solvents in atomic absorption spectrometry
PublikacjaAtomic absorption spectrometry (AAS) is a widely applied technique for metal quantification due to its practicality, easy use and low cost. However, to improve the metrological characteristics of AAS, in particular the sensitivity and the detection limit, sample pretreatment is commonly used before the detection step itself. In consideration of the principles of Green Analytical Chemistry, new solvents are being introduced into...
-
Warstwowa ocena epidemiologiczna architektury zakładów opiekuńczo-leczniczych i zakładów gieriatycznych = Layer based epidemiological quality assessment of architecture of care security and geriatric wards
PublikacjaW artykule opisano możliwość wykorzystania autorskiej metody warstwowej oceny epidemiologicznej (WOE) do oceny potencjalnego ryzyka zakażeń w obiektach przeznaczonych dla osób starszych. Materiał i metody: W celu weryfikacji możliwości użycia metody WOE do oceny zagrożeń w zakresie bezpieczeństwa epidemiologicznego środowiska zbudowanego poddano analizie dostępne źródła literatury związane z obowiązującymi w Polsce wymaganiami...
-
Optoelectronic device for hematocrit measurements
PublikacjaAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Optical-Fiber Microsphere-Based Temperature Sensors with ZnO ALD Coating—Comparative Study
PublikacjaThis study presents the microsphere-based fiber-optic sensor with the ZnO Atomic Layer Deposition coating thickness of 100 nm and 200 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range from 100 °C to 300 °C, with a 10 °C step. The interferometric signal was used to monitor the integrity of the microsphere and its attachment to the connecting fiber. For the sensor...
-
Measurement system based on USB Z-Wave controller
PublikacjaA wireless measurement system based on the Z-Wave standard is presented in this paper. The system is composed of a U SB Z-Stick Gen5 controller connected to a Personal Computer and a Fibaro controller FGRGBWM-441. Operation of the system is controlled by software written in C++ using OpenZWave library. Some metrological aspects of the system are evaluated: accuracy, linearity, resolution and frequency of voltage measurements.
-
Time Delay Estimation in Two-Phase Flow Investigation Using the γ-Ray Attenuation Technique.
PublikacjaTime delay estimation is an important research question having many applications in a range of technologies. Measurement of a two-phase flow in a pipeline or an open channel using radioisotopes is an example of such application. For instance, the determination of velocity of dispersed phase in that case is based on estimation of the time delay between two stochastic signals provided by scintillation probes. The proper analysis...
-
Wpływ stopowania laserowego z użyciem nanorurek węglowych stopu Ti13Nb13Zr do zastosowań biomedycznych na jego wybrane własności mechaniczne
PublikacjaDo eksperymentu użyto stopu tytanu Ti13Nb13Zr, który ze względu na swój skład chemiczny i właściwości mechaniczne stanowi materiał do zastosowań w inżynierii medycznej. Celem pracy była ocena wpływu stopowania laserowego stopu Ti13Nb13Zr z powłoką z wielościennych nanorurek węglowych na jego właściwości mechaniczne (chropowatość, nanotwardość, moduł Younga). Do wytworzenia powłoki węglowej wykorzystano metodę osadzania elektroforetycznego (EDP)....
-
Evaluation of Linkers’ Influence on Peptide-Based Piezoelectric Biosensors’ Sensitivity to Aldehydes in the Gas Phase
PublikacjaRecent findings qualified aldehydes as potential biomarkers for disease diagnosis. One of the possibilities is to use electrochemical biosensors in point-of-care (PoC), but these need further development to overcome some limitations. Currently, the primary goal is to enhance their metrological parameters in terms of sensitivity and selectivity. Previous findings indicate that peptide OBPP4 (KLLFDSLTDLKKKMSEC-NH2) is a promising...
-
Uncertainty analysis of measuring system for instantaneous power research
PublikacjaThe paper presents a metrological analysis of the measurement system used for diagnosis of induction motor bearings, based on the analysis of the instantaneous power. This system was implemented as a set of devices with dedicated software installed on a PC. A number of measurements for uncertainty estimation was carried out. The results of the measurements are presented in the paper. The results of the aforementioned analysis helped...
-
Opracowanie technologii naprawy nieciągłości metalicznych w połączeniach spawanych, w konstrukcji podpór przednich pras filtracyjnych położonych na terenie Grupowej Oczyszczalni Ścieków Dębogórze
PublikacjaCelem niniejszej pracy jest opracowanie wytycznych technologicznych, których wdrożenie pozwoli na usunięcie istniejących pęknięć, co przyczyni się do stabilizacji wymiarowej podpór oraz całej konstrukcji pras. Osiągniecie tego celu wymaga podjęcia następujących działań: - ocenę stanu technicznego naprawianego komponentu- podpór przednich trzech pras filtracyjnych, - określenie własności spawalniczych materiału naprawianego, -...
-
Validation of atmospheric aerosols parallel sampling in a multifold device
PublikacjaIn this work, particulate matter was collected using an active sampling system consisting of a PM10 (<10 μm) inlet coupled to a multifold device containing six channels, connected to a vacuum pump. Each channel was equipped with a filter holder fitted with adequately chosen filters. The system was fixed on a metallic structure, which was placed on the roof of the laboratory building, at the Faculty of Sciences, in Lisbon. Sampling...
-
Sharp transitions in low-number quantum dots Bayesian magnetometry
PublikacjaWe consider Bayesian estimate of static magnetic field, characterized by a prior Gaussian probability distribution, in systems of a few electron quantum dot spins interacting with infinite temperature spin environment via hyperfine interaction. Sudden transitions among optimal states and measurements are observed. Usefulness of measuring occupation levels is shown for all times of the evolution, together with the role of entanglement...
-
Adaptive filtering approach to dynamic weighing: a checkweigher case study
PublikacjaDynamic weighing, i.e., weighing of objects in motion, with out stopping them on the weighing platform, allows one to increase the rate of operation of automatic weighing systems used in industrial production processes without compromising their accuracy. The paper extends and compares two approaches to dynamic weighing, based on system identification and variable-bandwidth filtering, respectively. Experiments, carried on a conveyor...
-
The use of low-coherence interferometer for sugar content determination
PublikacjaIn this article, the implementation of low-coherence interferometer with signal processing in time domain for sugar content determination in aqueous solution is presented. The elaborated measurement set-up was tested with the use of synthesized source made of two low-coherence sources. The use of two sources with dedicated parameters enabled to obtain a proper metrological parameters of the measurement system. The elaborated low-coherence...
-
Innovative mobile method to determine railway track axis position in global coordinate system using position measurements performed with GNSS and fixed base of the measuring vehicle
PublikacjaThe shape of the railway track axis and its position in the global coordinate system are essential when defining design parameters of the railway. Correct reconstruction of these quantities is vital for both verifying the compliance of real track parameters with the design and for diagnosing, as all track deformations can also be defined as deviations of real parameters from their design values. The measurements of quantities related...
-
Identyfikacja gatunku stali zastosowanej w obiektach budowlanych
PublikacjaEksploatacja istniejących metalowych konstrukcji budowlanych często związana jest z zagadnieniem koniecznej szczegółowej identyfikacji rodzaju materiału stalowego pod kątem je go cech wytrzymałościowych i składu chemicznego. Dostępne standardowe metody laboratoryjne zazwyczaj wymagają pobrania z konstrukcji próbek materiału do badań, co nie zawsze jest możliwe. W artykule zaprezentowano alternatywne metody oceny wymienionych cech...
-
Badania eksperymentalne rezonansowego przetwornika piezoelektrycznego typu "unimorph"
PublikacjaW artykule opisano badania eksperymentalne piezoelektrycznego rezonansowego przetwornika zastosowanego do pomiaru właściwości mechanicznych tkanek miękkich. Po krótkim wstępie w kolejnych punktach przedstawiono opis stanowiska pomiarowego oraz metody pomiaru odkształceń prototypów, przesunięć częstotliwości rezonansowej, impedancji elektromechanicznej i parametrów schematów zastępczych. W dalszej...
-
Właściwości niskotemperaturowe betonów asfaltowych o wysokim module sztywności (AC-WMS) w badaniach trzypunktowego zginania
PublikacjaArtykuł przedstawia właściwości niskotemperaturowe betonów asfaltowych o wysokim module sztywności. Przedstawione wyniki zostały uzyskane w dwóch badaniach zginania trzypunktowego próbek belkowych: ze stałą prędkością przemieszczenia oraz pod stałym obciążeniem. Obie te metody są od dawna stosowane na Politechnice Gdańskiej do oceny właściwości niskotemperaturowych betonów asfaltowych. Badaniu poddano pięć betonów asfaltowych –...
-
Determination of long-chain aldehydes using a novel quartz crystal microbalance sensor based on a biomimetic peptide
PublikacjaThere is an increasingly popular trend aimed at improvement of fundamental metrological parameters of sensors via implementation of materials mimicking biological olfactory systems. This study presents investigation on usefulness of the peptide mimicking HarmOBP7 region as a receptor element of the piezoelectric sensor for selective analysis of long-chain aldehydes. Identification of odorant binding proteins creates new possibilities...
-
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublikacjaThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...
-
Miniaturized impedance analyzer using AD5933
PublikacjaThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
Miniaturized impedance analyzer using AD5933
PublikacjaThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
Three-Dimensional Fractography for Conventional and Additive Manufactured Steels After Bending-Torsion Fatigue
PublikacjaIn this study, fracture surface topography parameters were measured to investigate the effects of multiaxial loading. In order to assess the metrological aspects of fracture for notched specimens made of high-strength steels processed by both conventional and additively manufacturing (AM) techniques, an optical surface profilometer was used. Three bending moment to torsion moment ratios (B/T) were studied, i.e. 2, 1 and 2/3. The...
-
Fiber optic displacement sensor with signal analysis in spectral domain
PublikacjaIn this paper, a study of a low-coherence fiber optic displacement sensor is presented. The sensor consisted of a broadband source whose central wavelength was either at 1310 nm or 1550 nm, a sensing Fabry-Pérot interferometer operating in reflective mode and an optical spectrum analyzer acting as the detection setup. All these components were connected by a single-mode fiber coupler. Metrological parameters of the sensor were...
-
A numerical and experimental analysis of multi-hole orifice in turbulent flow
PublikacjaIn this research study, the comprehensive metrological analysis is investigated for a 4-hole orifice with module m = 0.25 installed in the pipeline with an internal diameter of 50 mm. A detailed numerical simulation was performed for the turbulence models: k-ε-realizable and k-ω-BSL. The novelties of the research include model validation by comparing the results of numerical studies with the experiment conducted in the area of...
-
Low-coherence sensors with nanolayers for biomedical sensing
PublikacjaIn this paper, we describe the fiber optic low-coherence sensors using thin film. We investigated their metrological parameters. Presented sensors were made with the use of standard telecommunication single mode optical fiber (SMF28). Different materials were applied to obtain thick layers, such as boron doped diamond, silver and gold. The thickness of layers used in the experiments ranged from 100 nm to 300 nm. Measurements were...
-
OCENA UZIEMIEŃ SŁUPÓW LINII ELEKTROENERGETYCZNYCH ZWŁASZCZA POSADOWIONYCH NA GRUNTACH O WYSOKIEJ REZYSTYWNOŚCI
PublikacjaW artykule została omówiona problematyka pomiaru i oceny właściwości uziemień słupów linii elektroenergetycznych z wykorzystaniem przebiegów wolno-i szybkozmiennych. Uzyskanie odpowiednio niskiej wartości rezystancji uziemienia słupa posadowionego na gruncie o rezystywności powyżej 1000Ωm może być trudne. Praca zawiera analizę zmian właściwości statycznych i udarowych uziemień w funkcji rezystywności...
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublikacjaThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
Elektrochemiczny czujnik na bazie cieczy jonowej do oznaczania par benzaldehydu
PublikacjaW pracy przedstawiono prototypowy, laboratoryjny, elektrochemiczny czujnik do oznaczania par benzaldehydu w argonie. Cieczą jonową testowaną jako elektrolit i środowisko reakcji redox była: bis(trifluorometylosulfonylo)imidek 1-butylo,3-metyloimidazolinowy ([BMIM][Tf2N]). W pomiarach użyto komercyjnych elektrod firm: DropSens Co. i BVT Technologies. Walidacji poddano dwa parametry metrologiczne czujnika: granicę wykrywalności i...
-
CHROMATOGRAPHIC TECHNIQUES IN PHARMACEUTICAL ANALYSIS IN POLAND: HISTORY AND THE PRESENCE ON THE BASIS OF PAPERS PUBLISHED IN SELECTED POLISH PHARMACEUTICAL JOURNALS IN XX CENTURY
PublikacjaFor a long time, chromatographic techniques and techniques related to them have stimulated the development of new procedures in the field of pharmaceutical analysis. The newly developed methods, characterized by improved metrological parameters, allow for more accurate testing of, among others, the composition of raw materials, intermediates and final products. The chromatographic techniques also enable studies on waste generated...
-
The use of thin diamond films in fiber optic low-coherence interferometers”
PublikacjaIn this paper we present the use of thin diamond films in fiber-optic low-coherence interferometers. Two kinds of diamond surfaces were used: undoped diamond film and boron-doped diamond film. They were deposited on glass plates as well as silicon layers. A conventionally used mirror was used as a reference layer. Diamond films were deposited using Microwave Plasma Enhanced Chemical Vapour Deposition (μPE CVD) system. Measurements...
-
Implementation of an Adaptive Method for Changing the Frequency Division of the Counter Clock Signal in a Frequency-to-Code Converter
PublikacjaProcessing physical quantities into an indirect signal is a standard method of transferring information about the measured quantity to the master system, which analyzes the data obtained from the acquisition system. The intermediate signal is very often the voltage, but another transmission medium can be the frequency of the output signal of the “physical quantity-to-frequency” converter. The article presents the implementation...
-
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
PublikacjaThis paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear...
-
A family of new generation miniaturized impedance analyzers for technical object diagnostics
PublikacjaThe paper presents the family of three analyzers allowing to measure impedance in range of 10 ohm<|Zx|<10 Gohm in a wide frequency range from 10 mHz up to 100 kHz. The most important features of the analyzers family are: miniaturization, low power consumption, low production cost, telemetric controlling and the use of impedance measurement method based on digital signal processing DSP. The miniaturization and other above mentioned...
-
Synchro-photogrammetry in the measurement of objects in motion - the case study
PublikacjaSynchronous photographs and digital photogrammetry methods in a measurement of objects in motion - the experiment. In the following paper, a case study example of a photogrammetric method based on synchronous digital photographs has been presented. This measurement method is an effective solution for tracking of moving objects, dynamic studies and dimensioning of geometry movements. Nowadays, the use of synchronous photography...
-
Prototype of electrochemical sensor for measurements of volatile organic compounds in gases
PublikacjaThe paper presents a laboratory prototype of an electrochemical sensor for measurements of volatile organic compounds (VOCs) in gases, utilizing ionic liquids and commercial screen printed electrodes by DropSens. The following ionic liquids have been tested as the electrolyte and redox reaction environment: 1-butyl, 3-methylimidazolium dicyanoamide ([BMIM][N(CN)2]), 1-octyl, 3-methylimidazolium tetrafluoroborate ([OMIM][BF4]),...
-
Support for argument structures review and assessment
PublikacjaArgument structures are commonly used to develop and present cases for safety, security and for other properties of systems. Such structures tend to grow excessively, which causes problems with their review and assessment. Two issues are of particular interest: (1) systematic and explicit assessment of the compelling power of an argument, and (2) communication of the result of such an assessment to relevant recipients. The paper...
-
Exhaust gas temperature measurements in diagnostics of turbocharged marine internal combustion engines. Part I. Standard measurements.
PublikacjaThe article discusses the problem of diagnostic informativeness of exhaust gas temperature measurements in turbocharged marine internal combustion engines. Theoretical principles of the process of exhaust gas flow in turbocharger inlet channels are analysed in its dynamic and energetic aspects. Diagnostic parameters are defined which enable to formulate general evaluation of technical condition of the engine based on standard...
-
Zastosowanie testu biologicznego Microtox do oceny skuteczności działania oczyszczalni ścieków bytowo-przemysłowych
PublikacjaOcena efektywności procesu oczyszczania ścieków z zastosowaniem biotestu Microtox® na przykładzie wybranej oczyszczalni Powszechnie praktykowanym sposobem wprowadzania ścieków oczyszczonych do środowiska jest ich punktowy zrzut do wód powierzchniowych. Różnorodność działalności prowadzonej w ramach współczesnej gospodarki sprawia, że do oczyszczalni docierają nie tylko substancje, których oznaczanie jest wymagane przez przepisy...
-
The correlation of fractal dimension to fracture surface slope for fatigue crack initiation analysis under bending-torsion loading in high-strength steels
PublikacjaIn this study, the fractal dimension of fatigue fracture surfaces is investigated in order to find an alternative failure loading indicator. Some of many metrological factors are generalized by reducing the fracture surface structure to one factor and develop an entire fracture surface procedure by analyzing the impact of surface slope and calculation resolution. Three notched geometries are studied under cyclic bending-torsion:...
-
Olfactory receptor-based biosensors as potential future tools in medical diagnosis
PublikacjaThe detection of biomarkers is the future of non-invasive medical diagnosis and screening. Discovery and identification of reliable disease specific volatile organic compounds is dependent on repeatable, accurate analysis of trace level gaseous analytes mainly in breath samples. Natural variety of the olfactory systems and the compounds capable of gas molecules binding creates wide possibilities of acquisition and implementation...
-
Development of thin film SPME sorbents based on deep eutectic solvents and their application for isolation and preconcentration of endocrine-disrupting compounds leaching from diapers to urine
PublikacjaIn this study, the thin film solid phase microextraction (TF-SPME) based on a novel sorbent composed of deep eutectic solvent (DES) is proposed. Among several synthesized sorbents the most efficient was DES containing trihexyl(tetradecyl)phosphonium chloride and docosanol mixed with polydimethylsiloxane (PDMS) in a molar ratio 1:3:0.25 to achieve a more stable structure. The proposed sorbent was applied on a fiberglass mesh and...
-
Stabilities of bisphenol A diglycidyl ether, bisphenol F diglycidyl ether, and their derivatives under controlled conditions analyzed using liquid chromatography coupled with tandem mass spectrometry
PublikacjaBisphenol A diglycidyl ether (BADGE), bisphenol F diglycydyl ether (BFDGE), and their related compounds are widely used as precursors in production of epoxy resins. The high reactivity of these compounds makes the development of analytical methodologies that ensure appropriate metrological accuracy crucial. Consequently, we aimed to determine whether and to what extent the composition of the solution and storage conditions affect...
-
The miniaturised emission chamber system and home-made passive flux sampler studies of monoaromatic hydrocarbons emissions from selected commercially-available floor coverings
PublikacjaThe estimation of the emission rate of organic compounds released from various types of indoor materials can be performed using stationary environmental test chambers (ETC) classified as ex-situ methods or small-scale portable analytical devices based on the use of passive technique at the stage of analytes sampling from the gaseous phase (in-situ methods). The paper presents results of emissions of selected organic compounds from...
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublikacjaA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...