Filtry
wszystkich: 942
Wyniki wyszukiwania dla: kelvin probe microscopy
-
Noble metal modified TiO2 microspheres: Surface properties and photocatalytic activity under UV-vis and visible light
PublikacjaComposite photocatalysts that consist of TiO2and noble metal nanostructures have been considered tobe the promising and pivotal material for accessible enhancement of the efficiency in the photocatalyticprocess carried out in the aqueous and gas phases. In this work we fabricated porous TiO2microspheresthrough a hydrothermal process followed by photochemical reduction of noble metal nanoparticles atthe TiO2surface. The morphology...
-
Preparation, characterization and photocatalytic activity of TiO2 microspheres decorated by bimetallic nanoparticles
PublikacjaComposite photocatalysts that consist of TiO2and noble metal nanostructures have been considered tobe the promising and pivotal material for accessible enhancement of the efficiency in the photocatalyticprocess carried out in the aqueous and gas phases. In this work we fabricated porous TiO2microspheresthrough a hydrothermal process followed by photochemical reduction of noble metal nanoparticles atthe TiO2surface. The morphology...
-
Development of the sound field 3D intensity probe based on miniature microphones
PublikacjaThe engineered measuring probe uses three pairs of miniature microphones coupled. The signals from the microphones after an initial amplification are fed to differential circuits. Due to the required symmetry of the circuit it was necessary to select electronic components very carefully. Moreover, additional digital signal processing techniques were applied to avoid amplitude and phase mismatch. The view of the engineered probe...
-
Assessing Highway Travel Time Reliability using Probe Vehicle Data
PublikacjaProbe vehicle data (also known as “floating car data”) can be used to analyze travel time reliability of an existing road corridor in order to determine where, when, and how often traffic congestion occurs at particular road segments. The aim of the study is to find the best reliability performance measures for assessing congestion frequency and severity based on probe data. Pilot surveys conducted on A2 motorway in Poland confirm...
-
Microscopy methods in nanotechnology
Kursy Online -
Applied Microscopy
Czasopisma -
DIFFRACTION PHASE MICROSCOPY FOR OBSERVATION ON RED BLOOD CELLS FLUCTUATION
PublikacjaNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – RBCs (Red Blood Cells). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations observation...
-
Observation on red blood cells fluctuations by diffraction phase microscopy
PublikacjaNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – Red Blood Cells (RBCs). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations...
-
Application of multisine nanoscale impedance microscopy to heterogeneous alloy surface investigations
PublikacjaIn the recent years atomic force microscopy is recognized as valuable tool for investigation of surficial features of construction materials. It concerns, among other things, studies of changes caused by such phenomena as galvanic corrosion, passivation associated with the growth of oxide layers, or sensitization of austenitic steels with the formation of carbide phases. In addition, atomic forcemicroscopy allows easy coupling...
-
PHASE OBJECT OBSERVATION SYSTEM BASED ON DIFFRACTION PHASE MICROSCOPY
PublikacjaIn the paper authors present a special measurement system for observing phase objects. The diffraction phas microscopy makes it possible to measure the dimensions of a tested object with a nanometre resolution. To meet this requirement, it is proposed to apply a spatial transform. The proposed setup can be based either on a two lenses system (called 4 f ) or a Wollaston prism. Both solutions with all construction aspects are described...
-
Fluorescence imaging spectroscopy and microscopy
Publikacja -
Probe signal processing for channel estimation in underwater acoustic communication system
PublikacjaUnderwater acoustic communication channels are characterized by a large variety of propagation conditions. Designing a reliable communication system requires knowledge of the transmission parameters of the channel, namely multipath delay spread, Doppler spread, coherence time, and coherence bandwidth. However, the possibilities of its estimation in a realtime underwater communication system are limited, mainly due to the computational...
-
Prototype of an opto-capacitive probe for non-invasive sensing cerebrospinal fluid circulation
PublikacjaIn brain studies, the function of the cerebrospinal fluid (CSF) awakes growing interest, particularly related to studies of the glymphatic system in the brain, which is connected with the complex system of lymphatic vessels responsible for cleaning the tissues. The CSF is a clear, colourless liquid including water (H2O) approximately with a concentration of 99 %. In addition, it contains electrolytes, amino acids, glucose, and...
-
INVESTIGATIONS OF THE LABORATORY FARYMANN DIESEL ENGINE D10 TYPE BY MEANS OF A LANGMUIR PROBE
PublikacjaA precise determination of the crankshaft angular position, at which fuel ignition occurs in the SI engine, enables credible diagnosis of the technical state of its working space as well as of the fuel feed system. An observation of the Langmuir probe signal provides entirely new possibilities for engine diagnostics. The probe is introduced into the working space of a cylinder through its indicator valve. This paper presents the...
-
Piezoresponse force microscopy and dielectric spectroscopy study of Ba0.6Sr0.4TiO3 thin films
PublikacjaResearch on synthesis, characterization and determination of processing – structure – property relationships of commercially important ferroelectric thin films has been performed. The sol-gel-type solution deposition technique was applied to produce good quality thin films of Ba0.6Sr0.4TiO3 (BST60/40) chemical composition on the stainless steel substrates. The thin films were characterized in terms of their microstructure, crystal...
-
Application of the 2-deoxyglucose scaffold as a new chiral probe for elucidation of the absolute configuration of secondary alcohols
PublikacjaHerein, we present the application of 2-deoxy-D-glucose derivatives as chiral probes for elucidation of the absolute configuration of chiral secondary alcohols. The probes are attached to the studied molecules via glycosylation reaction and the resulting products are examined by a set of standard 2D NMR experiments. The absolute configuration of an oxymethine carbon atom binding the probe is established on a basis of a set of diagnostic...
-
Photoluminescence as a probe of phosphorene properties
PublikacjaHere, we provide a detailed evaluation of photoluminescence (PL) as a comprehensive tool for phosphorene characterization with the emphasis on a prominent quantitative role of PL in providing fingerprint-like features due to its extreme sensitivity to the band structure details, anisotropy, disorder, external fields, etc. Factors such as number of layers, dimensionality, structural and chemical disorder, and environmental factors...
-
Photoluminescence as a probe of phosphorene properties
Publikacja -
Magnetically sensitive fiber probe with nitrogen-vacancy center nanodiamonds integrated in a suspended core
PublikacjaEfficient collection of photoluminescence arising from spin dynamics of nitrogen vacancy (NV) centers in diamond is important for practical applications involving precise magnetic field or temperature mapping. These goals may be realized by the integration of nanodiamond particles with optical fibers and volumetric doping of the particles alongside the fiber core. That approach combines the advantages of robust axial fixation of...
-
Study of probe signal bandwidth influence on estimation of coherence bandwidth for underwater acoustic communication channel
PublikacjaA signal transmitted in a shallow Underwater Acoustic Communication (UAC) channel suffers from time dispersion due to the multipath propagation and the refraction phenomena. This causes intersymbol interference of the received signal and frequency-selective fading observed in its spectrum. Coherence bandwidth is one of the key transmission parameters used for designing the physical layer of a data transmission system to minimise...
-
An Analysis of Probe-Fed Rectangular Patch Antennas With Multilayer and Multipatch Configurations on Cylindrical Surfaces
PublikacjaA multi-patch configuration of probe-fed rectangular microstrip antennas mounted on a cylindrical body, with electrically small radius, with an arbitrary number of substrate and superstrate layers is investigated in this paper. A full-wave analysis and a moment-method calculation are employed. A unified procedure for creating proper matrices for the investigated geometry of the structure is outlined here. Numerical results for...
-
MICROSCOPY RESEARCH AND TECHNIQUE
Czasopisma -
JOURNAL OF ELECTRON MICROSCOPY
Czasopisma -
Journal of Microscopy and Ultrastructure
Czasopisma -
Malaysian Journal of Microscopy
Czasopisma -
The Magnetic Fluid Seals Research Results vs. Kelvin-Helmholtz (K-H) instability and Preliminary Conclusions
PublikacjaIn the article a magnetic-fluid seals durability research and the tests results are presented. The tests were made with three magnetic fluids using various magnets quantity in magnetic assemblies. If values obtained in the repeated test deviated by more than 10 % from results of the first test an additional control test was made for final characteristics. The characteristics are: critical pressure, critical motion velocity and...
-
Progress in the post weld residual stress evaluation using Barkhausen effect meter with a novel rotating magnetic field probe
PublikacjaWe report the progress in post weld residual stress evaluation using Barkhausen effect (BE) meter with rotating magnetic field probe. The novel probe of the BE meter contains two C-core electromagnets and searching coil with ferrite antenna. This meter allows automatic measurements of BE intensity envelopes at different angles of magnetizing field. The full process of measurement at given position of the probe takes about only...
-
The Progress in Electron Microscopy Studies of Particulate Matters to Be Used as a Standard Monitoring Method for Air Dust Pollution
PublikacjaThe present article reviews studies on air solid particles carried out with the use of electron microscopy. Particle analysis combining scanning and transmission electron microscopy (SEM and TEM) can be used to derive size-resolved information of the composition, mixing state, morphology, and complex refractive index of atmospheric aerosol particles. It seems that electron microscopy is more widely used in atmospheric particulate...
-
SEM (scanning electron microscopy) and TEM (transmission electron microscopy) images of PMD and PMH
Dane BadawczeThese data contains SEM (scanning electron microscopy) and TEM (transmission electron microscopy) images of PMD and PMH. TEM was performed on a FEI Tecnai F30 transmission electron microscope operating at an acceleration voltage of 200 kV. SEM was done with a SEM, XL30ESEM-FEG with an acceleration voltage of 20 KV. Sample abbreviations (PMH, PMD) are...
-
Measurement system for nonlinear surface spectroscopy by atomic force microscopy for corrosion processes monitoring
PublikacjaIn addition to traditional imaging the surface, atomic force microscopy (AFM) enables wide variety of additional measurements. One of them is higher harmonic imaging. In tapping mode the nonlinear contact between tip and specimen results in higher frequency vibrations. More information available from the higher harmonics analysis proves to be helpful for more detailed imaging. Such visualization is especially useful for heterogeneous...
-
Results of calibration of the piezoelectric scanner using the probe TGQ1
Dane BadawczeTeaching file. Results of calibration of the piezoelectric scanner using the probe TGQ1. Scanning in contact mode. NTEGRA Prima (NT-MDT) device. CSG probe 10.
-
Raman microscopy in the studies of microphase-separated polyurethanes.
PublikacjaPorównano możliwości badawcze różnych odmian spektroskopowych do analizy po-limerów. Podano przykłądy wykorzystania połączonych technik mikroskopowych ispektroskopowych do badania polimerów wielofazowych. Na tej podstawie wyka-zano zasadność zastosowania po raz pierwszy mikroskopii Ramana w badaniachwielofazowych poliuretanów. Wykazano różnice składu chemicznego poszczegól-nych elementów mikromorfologii wielofazowych, segmentowych...
-
PROJECT OF AN TDC SIGNAL DISTRIBUTOR PROTOTYPE WITH GAL-VANIC SEPARATION DESTINED FOR STUDIES OF THE BEGINNING OF SELFIGNITION USING LANGMUIR PROBE
PublikacjaThe knowledge of pistons' TDC is crucial while performing any kind of measurement beneficial to diagnostic inference of a diesel engine. The research of engines under exploitation often cause impartial difficulties with, eg. capability of probe installation. Therefore, it becomes crucial to minimalize those. The paper presents a description of a TDC impulse distributor - divider that provides signal delivery to more than one measurement...
-
Nonlinear free and forced vibrations of a dielectric elastomer-based microcantilever for atomic force microscopy
PublikacjaThe majority of atomic force microcode (AFM) probes work based on piezoelectric actuation. However, some undesirable phenomena such as creep and hysteresis may appear in the piezoelectric actuators that limit their applications. This paper proposes a novel AFM probe based on dielectric elastomer actuators (DEAs). The DE is modeled via the use of a hyperelastic Cosserat model. Size effects and geometric nonlinearity are included...
-
A ring-based probe for determination of the skin conductivity
PublikacjaW pracy przedstawiono konstrukcję sondy do pomiarów przewodności skóry wstanie oparzenia.
-
A six-ring probe for monitoring conductivity changes
Publikacjastreszczenie: W pracy przedstawiono konstrukcję sondy szściopierścieniowej do monitorowania zmian immitancji. Zdefiniowano czułość sondy i przedstawiono jej rozkład dla przypadków izotropowych i anizotropowych. Teoretyczne symulacje za pomocą metody elementów skończonych zostały zweryfikowane eksperymentalnie, za pomocą specjalnie skonstruowanego zestawu pomiarowego. Zamieszczono przykładowe pomiary in vivo.
-
Application of the Barkhausen effect probe with adjustable m agnetic field direction for stress state determination in the P91 ste el pipe
PublikacjaThe paper presents the results of application of a novel Barkhausen effect (BE) probe with adjustable magnetizing field direction for the stress level evaluation in ferromagnetic materials. The investigated sample was in a form of a pipe, made of P91 steel that was anisotropic due to the production process. The measurements were performed before and after welding, revealing the influence of welding process on the residual stress...
-
Assessment of Wide-Sense Stationarity of an Underwater Acoustic Channel Based on a Pseudo-Random Binary Sequence Probe Signal
PublikacjaThe performances of Underwater Acoustic Communication (UAC) systems are strongly related to the specific propagation conditions of the underwater channel. Designing the physical layer of a reliable data transmission system requires a knowledge of channel characteristics in terms of the specific parameters of the stochastic model. The Wide-Sense Stationary Uncorrelated Scattering (WSSUS) assumption simplifies the stochastic description...
-
Silica In Silico: A Molecular Dynamics Characterization of the Early Stages of Protein Embedding for Atom Probe Tomography
PublikacjaA novel procedure for the application of atom probe tomography (APT) to the structural analysis of biological systems, has been recently proposed, whereby the specimen is embedded by a silica matrix and ablated by a pulsed laser source. Such a technique, requires that the silica primer be properly inert and bio-compatible, keeping the native structural features of the system at hand, while condensing into an amorphous, glass-like...
-
Application of dynamic impedance spectroscopy to atomic force microscopy
Publikacja -
Visualization and characterization of prolamellar bodies with atomic force microscopy
Publikacja -
Application of dynamic impedance spectroscopy to atomic force microscopy
PublikacjaMikroskopia sił atomowych jest uniwersalną techniką obrazowania powierzchni podczas gdy spektroskopia impedancyjna jest fundamentalną metodą charakteryzowania właściwości elektrycznych materiałów. Z powyższego względu użyteczne jest połączenie powyższych technik dla uzyskania przestrzennego rozkładu wektora impedancji. W pracy autorzy proponują nowe podejście polegające na połączeniu multiczęstotliwościowego pomiaru impedancyjnego...
-
Journal of Advanced Microscopy Research
Czasopisma -
Broadening the scope of measurement and analysis of vibrations of an organ pipe employing intensity probe, simulations, and highspeed camera
PublikacjaThis paper shows an integrated approach to measure, analyze, and model phenomena occurring in an organ pipe driven by pressurized air. The aim of this paper is two-fold, i.e., to measure the pressure signal and the intensity field around the mouth by means of an intensity probe and to visualize and observe the motion of the air jet, which represents the excitation mechanism of the system. This is realized through two techniques,...
-
The high impedance measuring probe for gain-phase analysers.
PublikacjaAutorzy opracowali tanią sondę pomiarową przeznaczoną do pracy z analizatorami gain-phase jak Solartron 1260 Impedance/Gain-phase Analyser, 1255 Frequency Response Analyser (FRA) lub starszymi wersjami 1250, 1253. Przedstawiona architektura sondy wyznacza jej parametry metrologiczne. Pomiary możliwe są w 8 zakresach obejmujących wartości 100ohm<|Zx|<100Gohm w szerokim zakresie częstotliwości 10uHz-1MHz. Obwód wejściowy sondy pozwala...
-
A probe for immittance spectroscopy based on the parallel electrode technique.
PublikacjaW pracy zaprezentowano konstrukcję sondy do spektroskopowych pomiarów immitancyjnych. Obliczono jej stałą, którą to wartość zweryfikowano eksperymentalnie. Pokazano przykładowe wyniki pomiarów in vivo.
-
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublikacjaW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwości od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...
-
Rapid cardiac ischemia detection with an epicardial graphene probe
Publikacja -
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublikacjaW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwosci od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...
-
New concept of a measurement probe for high impedance spectrocopy
PublikacjaArtykuł przedstawia nową koncepcję sondy pomiarowej służącej jako obwód wejściowy analizatora do spektroskopii wysokoimpedancyjnej. Dzięki wykorzystaniu przetwornika prąd na napięcie uzyskano najmniejszy możliwy wpływ pojemności kabli dołączających mierzony obiekt na wynik pomiaru. Przeprowadzono analizę sondy biorąc pod uwagę najważniejsze parametry wpływające na dokładność pomiaru: pojemności pasożytnicze oraz rzeczywiste parametry...