Filtry
wszystkich: 758
Wyniki wyszukiwania dla: MATRIX SENSORS
-
Statistical Data Pre-Processing and Time Series Incorporation for High-Efficacy Calibration of Low-Cost NO2 Sensor Using Machine Learning
PublikacjaAir pollution stands as a significant modern-day challenge impacting life quality, the environment, and the economy. It comprises various pollutants like gases, particulate matter, biological molecules, and more, stemming from sources such as vehicle emissions, industrial operations, agriculture, and natural events. Nitrogen dioxide (NO2), among these harmful gases, is notably prevalent in densely populated urban regions. Given...
-
On Memory-Based Precise Calibration of Cost-Efficient NO2 Sensor Using Artificial Intelligence and Global Response Correction
PublikacjaNitrogen dioxide (NO2) is a prevalent air pollutant, particularly abundant in densely populated urban regions. Given its harmful impact on health and the environment, precise real-time monitoring of NO2 concentration is crucial, particularly for devising and executing risk mitigation strategies. However, achieving precise measurements of NO2 is challenging due to the need for expensive and cumbersome equipment. This has spurred...
-
Metaplastic carcinoma, NOS - Female, 65 - Tissue image [8020729577648371]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [1300630017392821]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [8020729577648621]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [1300630017393821]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [8020729577649101]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 65 - Tissue image [8020729577645521]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [1300630017391621]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [1300630017393901]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [1300630017395081]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Plasma models, contribution matrix for detector setup and generated projections for plasma emissivity reconstruction in fusion devices
Dane BadawczeThe original plasma models for fusion devices, together with the complementary detector setup in the form of a contribution matrix and generated projections. Samples are packed inside a Plasma Tomography Format (PTF) files which is a part of the Plasma Tomography in Fusion Devices Python package, and inside the general JSON format. The constructed dataset...
-
MEMS Gyro in the Context of Inertial Positionning
PublikacjaThe article undertake some vital aspect in geodesy, namely an inertial positioning problem using MEMS. Although MEMS inertial sensors offer affordable, appropriately scaled units, and though their inherent measurement noise can be relatively easily mitigated, there are still parameters due to they are not currently capable of meeting all requirements for the accurate and precise inertial positioning. The article presents crucial...
-
Intelligent Autonomous Robot Supporting Small Pets in Domestic Environment
PublikacjaIn this contribution, we present preliminary results of the student project aimed at the development of an intelligent autonomous robot supporting small pets in a domestic environment. The main task of this robot is to protect a freely moving small pets against accidental stepping on them by home residents. For this purpose, we have developed the mobile robot which follows a pet and makes an alarm signal when a human is approaching....
-
Wearable system supporting navigation of the blind
PublikacjaImproving blind people comfort of life is a problem ofgreat importance. Fortunately, new technolgies provide us withadditional methods to improve everyday life of the blind and visuallyimpaired. The paper presents experimental system made byresearchers from Department of Geoinformatics of Gdansk Universityof Technology, which is capable of finding the route from theindicated source to chosen destination, using dedicated digital...
-
Disturbances of Earth magnetic field caused by eddy currents of airplane
PublikacjaThe uniform magnetic field of the Earth in the surrounding of a mobile, metallic object undergoes deformation by eddy currents. The influence of the moving, conducting object on the Earth's total magnetic field depends on the object's shape, position and speed of the changes relative to the magnetic field vector of the Earth, as well as the electric conductivity and the relative magnetic permeability of the material. Disturbances...
-
Interactions with recognized objects
PublikacjaImplicit interaction combined with object recognition techniques opens a new possibility for gathering data and analyzing user behavior for activity and context recognition. The electronic eyewear platform, eGlasses, is being developed, as an integrated and autonomous system to provide interactions with smart environment. In this paper we present a method for the interactions with the recognized objects that can be used for electronic...
-
Integration of inertial sensors and GPS system data for underwater navigation
PublikacjaThe Inertial Navigation System (INS) is usually employed to determine the position of an underwater vehicles, like Remotely Operated Vehicles (ROV) and, more recently, Autonomous Underwater Vehicle (AUV). The accuracy of the position provided by the INS, which uses accelerometers and gyroscopes, deteriorates with time. An external aiding sources such as the Global Positioning System (GPS) can be employed to reduce the error growth...
-
Integrity level verification for safety-related functions
PublikacjaThis article describes methods for safety integrity level (SIL) verification of safety-related functions with regard to probabilistic criteria given international standards IEC 61508 and IEC 61511. These functions are to be realized using the electrical, electronic and programmable electronic (E/E/PE) systems or safety instrumented systems (SIS). Some methods are proposed for quantitative probabilistic modelling taking into account...
-
Structural Health Monitoring of Composite Shell Footbridge for Its Design Validation
PublikacjaThe paper presents the structural health monitoring system of the composite bridge for pedestrians and cyclists. The footbridge was designed and manufactured within the FOBRIDGE project. It is the first bridge in the world, which is classified as a consistent single element structural girder, made of sandwich shells, entirely produced in a single cycle. The developed structural health monitoring system, supported design process,...
-
Comparison of Evaluation of Air Odour Quality in Vicinity of Petroleum Plant Using a Prototype of Electronic Nose Instrument and Fast GC Technique
PublikacjaThe paper presents the results of investigation on classification of the ambient air samples collected in a vicinity of the LOTOS Group S.A. petroleum plant with respect to odour. The investigations were carried out with an electronic nose prototype and a commercial electronic nose of Fast GC-type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and a photoionization sensor of PID-type....
-
Vertical vibration reduction and audible sound analysis in surface grinding with electroplated tools
PublikacjaOne of the first approaches to the development of a grinding process monitoring system based on audible sound sensors is presented in the paper. Electroplated diamond tools (abrasive D64 and D107) were used in a modified single-disc lapping machine configuration for flat grinding of ceramics (Al2O3). The main aim of the machine modification was to reduce the vertical vibration in order to decrease the tool wear and to increase...
-
Stanowisko wizualizacji zdarzeń w systemie STRADAR – realizacja i funkcje dla operatora
PublikacjaIt is crucial for the Border Guard to be equipped with a communication-teleinformatic infrastructure designed to support them in efficient realization of their operational tasks. STRADAR – a system which results are presented in this paper – is such an infrastructure. It is a distributed solution for the maritime division of the border guard. The system, with the use of a network of sensors located in both stationary and mobile...
-
Analytical fluctuation enhanced sensing by resistive gas sensors
PublikacjaResistance fluctuations across polarised resistive gas sensors were studied in detail to evaluate sensor working conditions for detecting methane and ammonia at various concentrations. The 1/f noise component typically dominates other noise sources up to a few kHz and can be utilised to improve gas selectivity when compared with measurements of the sensor DC resistance. The Arrhenius plot was created and the activation energy for...
-
Road surface roughness estimation employing integrated position and acceleration sensor
PublikacjaAssessment of a surface quality being an essential task for the authorities supervising the roads provides the subject of the paper. Information about riding quality of a pavement, important for drivers, both in terms of their comfort and safety is collected during experiments employing mobile sensors. The paper describes the use of a miniature position and acceleration sensor for evaluation of the roughness of the road surface....
-
Analysis of guided wave propagation in adhesive joints of steel rods
PublikacjaThe aim of the study is the elastic wave propagation in adhesive joints of metal rods that are one of the simplest kind of glue connections. They are consisted of two metal members and an adhesive layer joining two parts together. The analysis is directed to technical diagnostics of such type of connections. Longitudinal and transversal guided waves were excited in prepared joints. Signals of propagating waves were registered in...
-
Different Ways to Apply a Measurement Instrument of E-Nose Type to Evaluate Ambient Air Quality with Respect to Odour Nuisance in a Vicinity of Municipal Processing Plants
PublikacjaThis review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents...
-
Doped Nanocrystalline Diamond Films as Reflective Layers for Fiber-Optic Sensors of Refractive Index of Liquids
PublikacjaThis paper reports the application of doped nanocrystalline diamond (NCD) films—nitrogen-doped NCD and boron-doped NCD—as reflective surfaces in an interferometric sensor of refractive index dedicated to the measurements of liquids. The sensor is constructed as a Fabry–Pérot interferometer, working in the reflective mode. The diamond films were deposited on silicon substrates by a microwave plasma enhanced chemical vapor deposition...
-
Gas sensors based on conducting polymers-recent developments
PublikacjaThis work discusses sensing performance dependence of PEDOT polymer and its composites on the counter ions used in the polymerization process. The sensors based on PEDOT-RGO composite show reversible response to NO2, while on PEDOT/LiClO4 irreversible. As a result, PEDOT-RGO could be used as a typical gas sensor, while sensor based PEDOT/LiClO4 could be used as an integrating gas sensor, also known as an accumulating gas sensor....
-
Polarization-dependent optical absorption in phosphorene flakes
PublikacjaThe interest of 2D materials is constantly increasing because of their very attractive mechanical, electrical and optical parameters. They have been used in many applications, e.g. photodetectors, sensors, modulators, insulators. One of the recently discovered 2D materials is phosphorene. In contrast to graphene, phosphorene has a direct bandgap tuned by numbers of layers in the 2D structure. The phosphorene flakes are strongly...
-
Seafloor relief reconstruction from side scan sonar data
PublikacjaSide scan sonar is one of the most widely used imaging systems in the underwater environment. It is relatively cheap and easy to deploy, in comparison with more powerful sensors. Although side scan sonar does not provide seafloor bathymetry directly, its records are directly related to seafloor images. In the paper, the method for 3D seafloor relief reconstruction from side scan sonar data is presented. The method is based on the...
-
Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter
PublikacjaA new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...
-
Speed Sensorless AC Drive with Inverter LC Filter and Fault Detection Using Load Torque Signal
PublikacjaThe industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve...
-
Stochastic resonance in measurements
PublikacjaNoise is usually associated with the negative phenomenon, hampering the measurements data and their analysis. This view has been broken in the '80s when the phenomenon of stochastic resonance (Stochastic Resonance - SR) was discovered. It is a phenomenon that occurs in nonlinear dynamic measurement systems when the selected input noise can optimize system performance. SR became a way to improve efficiency of weak signals detection....
-
Effect of oxygenation time on signal of a sensor based on ionic liquids
PublikacjaThe paper presents an oxygen sensor based on ionic liquids and solid electrodes. The following ionic liquids have been employed: [BMIM][BF4], [HMIM][Cl], [BMIM][N(CN2)]. Minimum time of the sensor exposure to analyte, after which the signal (current intensity) was stable, has been evaluated. An impact of volumetric flow rate of analyte on the sensor exposure time and signal has been determined. A product of permeability coefficient...
-
Nitrogen-Doped Diamond Film for Optical Investigation of Hemoglobin Concentration
PublikacjaIn this work we present the fabrication and characterization of a diamond film which can be utilized in the construction of optical sensors for the investigation of biological samples. We produced a nitrogen-doped diamond (NDD) film using a microwave plasma enhanced chemical vapor deposition (MWPECVD) system. The NDD film was investigated with the use of scanning electron microscopy (SEM), atomic force microscopy (AFM) and Raman...
-
An application of acoustic sensors for the monitoring of road traffic
PublikacjaAssessment of road traffic parameters for the developed intelligent speed limit setting decision system constitutes the subject addressed in the paper. Current traffic conditions providing vital data source for the calculation of the locally fitted speed limits are assessed employing an economical embedded platform placed at the roadside. The use of the developed platform employing a low-powered processing unit with a set of microphones,...
-
Determination of authenticity of brand perfume using electronic nose prototypes
PublikacjaThe paper presents practical application of an electronic nose technique for fast and efficient discrimination between authentic and fake perfume samples. Two self-built electronic nose prototypes equipped with a set of semiconductor sensors were employed for that purpose. Additionally 10 volunteers took part in sensory analysis. The following perfumes and their fake counterparts were analysed: Dior – Fahrenheit, Eisenberg – J’ose,...
-
Evaluation of Ambient Air Odour Quality in Vicinity of Municipal Landfill Using Electronic Nose Technique
PublikacjaThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of municipal landfill. The investigation was carried out with a prototype of electronic nose and a team of panelists utilizing the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. Performed measurements...
-
Application of guided wave propagation in diagnostics of steel bridge components
PublikacjaEarly detection of potential defects and identification of their location are necessary to ensure safe, reliable and long-term use of engineering structures. Non-destructive diagnostic tests based on guided wave propagation are becoming more popular because of the possibility to inspect large areas during a single measurement with a small number of sensors. The aim of this study is the application of guided wave propagation in...
-
Measurement method for capacitive sensors for microcontrollers based on a phase shifter
PublikacjaA complete measurement method dedicated to capacitive sensors has been developed. It includes the development of hardware (an analogue interface circuit for microcontrollers with built-in times/counters and analogue comparators) and software (a measurement procedure and a systematic error calibration (correction) algorithm which is based on a calibration dictionary). The interface circuit consists of a low-pass filter and a phase...
-
Metaplastic carcinoma, NOS - Female, 31 - Tissue image [130063001739121]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 31 - Tissue image [1300630017397361]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 31 - Tissue image [130063001739361]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 31 - Tissue image [1300630017391181]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [3300730069421971]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [8020729577642751]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 31 - Tissue image [1300630017397841]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 61 - Tissue image [8020729577643811]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Metaplastic carcinoma, NOS - Female, 31 - Tissue image [1300630017398401]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.