Filters
total: 1914
filtered: 288
-
Catalog
Chosen catalog filters
Search results for: FTIR%20SPECTROSCOPY
-
Fourier-transform infrared spectroscopy (FTIR) spectra of bulk boron and borophene flakes
Open Research DataThese data contain Fourier-transform infrared spectroscopy (FTIR) spectra of bulk boron and borophene flakes obtained during ball milling (450 rpm, 6 h, 1 g). Spectra were acquired to investigate the chemical bonds and functional groups on the surface of the pristine boron and borophene flakes.
-
FTIR (Fourier-transform infrared spectroscopy) spectra of titanium dioxide coated nickel foams.
Open Research DataThis dataset contains FTIR spectra recorded on a JASCO 4200 spectrometer of nickel foams coated with titanium dioxide after heating at 400, 500 and 600 C and after photocatalytic process with NOx.
-
FTIR spectra of V2O5 nanostructures
Open Research DataThe DataSet contains FTIR spectra of vanadium pentaoxide nanostructures obtained by the sol-gel with different annealing temperatures under synthetic air.
-
Lignocellulosic biomass pretreatment - FTIR data
Open Research DataLignocellulosic pretreated biomass has been analysed using FRIT spectroscopy to demonstrate changes occuring in biomass structure
-
FTIR spectra of VO2 and V2O3 nanostructures
Open Research DataThe DataSet contains the FTIR spectra of VO2 and V2O3 nanostructures obtained by the sol-gel with different reaction conditions. The information about xerogel powder synthesis is described in the Journal of Nanomaterials. The xerogel powder was annealing under argon atmosphere in the temperature range 400-1000C. The results show that the morphology...
-
FTIR in situ - ethylene decomposition on TiO2
Open Research DataThese data contain FTIR spectra recorded in FTIR spectrometer Nicolet iS50 coupled with High Temperature Chamber "The Praying Mantis". These spectra were measured for TiO2 irradiated by UV and under flowing of ethylene gas diluted in air. FTIR spectra were measured in situ during the photocatalytic process of ethylene decomposition. In order to identify...
-
Fourier transform infrared spectroscopy (FTIR) of pre- PXBS (0 h) and PXBS during the crosslinking process (24 h–288 h)
Open Research DataThe goal of this research was developing biodegradable and biocompatibile xylitol-based copolymers with improved mechanical properties, and investigating the change in their thermal and chemical properties withprogress of the cross-linking process. Using a raw material of natural origin such as xylitol, a prepolymer wasobtained by esterification and...
-
Methane (CH4) calibration set of FTIR spectra
Open Research DataThe calibration spectra for CH4 concentration calibration were supplied with this dataset
-
FTIR spectrum for biologically pre-treated lignocellulosic biomass
Open Research DataDataset contains FTIR spectrum data for lignocellulosic biomass obtained during the biological pretreatment period with the application of wild red, white and brown Rot Fungi.
-
FTIR spectra of Ce0.9M0.1O2 synthesised by reverse microemulsion method
Open Research DataThe dataset consist of the FTIR spectra of Ce0.9M0.1O2 synthesised by reverse microemulsion method, after calcination at 500 degrees.
-
Carbon dioxide (CO2) calibration set of FTIR spectra
Open Research DataThe calibration spectra for CO2 concentration calibration were supplied with this dataset
-
FTIR-TiO2 heated at 400-600oC in Ar or H2
Open Research DataData contain FTIR diffuse eflectance spectra of TiO2, which was heat-treated at 400-600oC in Ar or H2. Hydrogen reduced TiO2 revealed new bands due to the adsorption of some species on the titania oxygen vacancy sites.
-
Bio-based polyester polyols for polyurethane foams - chemical structure of reference sample
Open Research DataPresented dataset includes the results of FTIR and H NMR spectroscopy of bio-based polyester polyol - poly(propylene succinate) (reference sample for materials obtained during MINIATURA 4 project realization).
-
bio-based polyester polyols - chemical structure of Miniatura 4 proper samples
Open Research DataPresented results are related with project MINIATURA 4 realization. At the document, the chemical structure of bio-based polyester polyols (poly(propylene-co-propan-1,2,3-triol succinate)s) are presented as analysis of FTIR and H NMR spectroscopy.
-
Carbon (II) oxide (CO) calibration set of FTIR spectra
Open Research DataThe calibration spectra for CO concentration calibration were supplied with this dataset
-
Influence of bio-polyols with different molecular weight on properites of PUR-PIR foams
Open Research DataThis work attempts to validate the possibility of replacing petrochemical polyols with previously synthesized bio-polyols and their impact on the structure and properties of rigid polyurethane-polyisocyanurate (PUR-PIR). The influence of bio-polyols addition on foam properties was investigated by mechanical testing, Fourier transform infrared spectroscopy...
-
FTIR spectra and IGC chromatograms for chemically reduced graphene oxide aerogels (rGOA)
Open Research DataThe effect of selected synthesis parameters on reduced graphene oxide aerogels properties was investigated using Fourier-transform infrared spectroscopy and dynamic adsorption method (Inverse Gas Chromatography, IGC). Samples were synthesized by sol-gel method by reduction induced self-assembly of graphene oxide. As a reductant l-ascorbic acid was used....
-
Structure of ammonium vanadate synthesis by LPE-IonEx method
Open Research DataThe DataSet contains the XRD patterns, FTIR spectra of NH4VO3 crystals with different morphology obtained by the LPE-IonEx method.
-
FTIR spectra of SOFC with LSCNT layer fueled by biogas mixture at 750 C (pure)
Open Research DataThe dataset contains the FTIR spectra collected during the electrical measurements DIR-SOFC with LSCNT layer. The SOFC was reduced at 800degC in H2 prior to mesurements. The spectra were collected every 10 min.
-
Valorization of bio-based polyols synthesized via biomass liquefaction
Open Research DataAs the properties of polyols have a huge impact on the properties of manufactured polyurethanes, this study aims to determine the influence of polyethylene glycols with different molecular masses on the course of the biomass liquefaction process and bio-polyol properties. The obtained polyols were characterized by rheological studies. To confirm the...
-
FTIR spectra of gas mixtures from the process of biogas dry reforming using CLO catalyst
Open Research DataThe dataset contains the FTIR spectra collected during the catalytic measurements of dry reforming of biogas (60/40 CH4-CO2) using Ce0.8La0.2O2 nanocatalyst. The specatra were collected every 1 minute.
-
Luminescence and FTIR measurements of B2O3-Bi2O3-SrF2 glass and glass-ceramics doped with Eu3+ ions
Open Research DataLuminescence and FTIR measurements of B2O3-Bi2O3-xSrF2+2Eu (x=10,20) glass and glass-ceramics. The emission and excitation spectra of the samples depend on the composition and annealing time.
-
FTIR spectra of gas mixtures from the methanation chamber filled with 50-50wt.% NiO-Al2O3
Open Research DataThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 50/50 wt.% NiO-Al2O3 catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
FTIR spectra of gas mixtures from the methanation chamber filled with 25-75wt.% NiO-Al2O3
Open Research DataThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 25/75 wt.% NiO-Al2O3 catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
FTIR spectra of gas mixtures from the methanation chamber filled with 50-50wt.% NiO-GDC
Open Research DataThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 50/50 wt.% NiO-GDC (Gadolinia Doped Ceria 20mol.%Gd2O3) catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
The changes of outlet gases concentrations from SOFC with Ce(Pr,Sm)O2-s layers
Open Research DataThe dataset includes The changes of outlet gases concentrations from SOFC with Ce(Pr,Sm)O2-s layers. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding.
-
FTIR spectra of gas mixtures from the process of biogas dry reforming using alumina catalyst - blank
Open Research DataThe dataset contains the FTIR spectra collected during the catalytic measurements of blank sample Al2O3 for dry reforming of biogas (60/40 CH4-CO2). The specatra were collected every 1 minute.
-
FTIR spectra of gas mixtures from the process of biogas dry reforming using CLO/Cu catalyst
Open Research DataThe dataset contains the FTIR spectra collected during the catalytic measurements of dry reforming of biogas (60/40 CH4-CO2) using Ce0.8La0.2O2+10wt.%Cu nanocatalyst. The specatra were collected every 1 minute.
-
FTIR spectra of gas mixtures from the process of biogas dry reforming using CeO2/Cu catalyst
Open Research DataThe dataset contains the FTIR spectra collected during the catalytic measurements of dry reforming of biogas (60/40 CH4-CO2) using CeO2+10wt.%Cu nanocatalyst. The specatra were collected every 1 minute.
-
FTIR spectra of gas mixtures from the process of biogas dry reforming using Al2O3/5%Cu catalyst
Open Research DataThe dataset contains the FTIR spectra collected during the catalytic measurements of dry reforming of biogas (60/40 CH4-CO2) using AlOOH/1%Cu nanocatalyst. The specatra were collected every 1 minute from 800C to 500C. Reagent flow was set to 20ml/min.
-
FTIR spectra of gas mixtures from the process of biogas dry reforming using CeO2/5%Cu catalyst
Open Research DataThe dataset contains the FTIR spectra collected during the catalytic measurements of dry reforming of biogas (60/40 CH4-CO2) using CeO2/5%Cu nanocatalyst. The specatra were collected every 1 minute from 800C to 500C. Reagent flow was set to 20ml/min.
-
FTIR spectra of gas mixtures from the process of biogas dry reforming using Al2O3/5%Cu catalyst
Open Research DataThe dataset contains the FTIR spectra collected during the catalytic measurements of dry reforming of biogas (60/40 CH4-CO2) using Al2O3 (TMDAR)/5%Cu nanocatalyst. The specatra were collected every 1 minute from 800C to 500C. Reagent flow was set to 20ml/min.
-
Morphology and structure of ammonium vanadates synthesis by hydrothermal method
Open Research DataThe DataSet contains the XRD patterns, FTIR spectra, and scanning electron microscopy (SEM) micrographs of ammonium vanadates synthesis by hydrothermal method from different NH4VO3 precursors. The results reveal that a mixture of (NH4)V4O10xH2O and(NH4)0.76V4O10 was obtained for both precursors, however the contribution of each phase was different for...
-
Force-deformation spectroscopy in contact mode
Open Research DataThe deformation-distance spectroscopic curve is obtained by registering the value of the probe cantilever deflection as a function of the elongation of the piezoelectric scanner. It assumes a simple relationship in the form of Hooke’s law, linking the deformation of the lever with the amount of its deflection caused by the proximity of the probe and...
-
Change of exhaust gases concentration for SOFC fueled by H2 and biogas mixture at 750 C
Open Research DataThe dataset contains the Change of exhaust gases concentration for SOFC fueled by H2 (for 12h) and biogas mixture at 750 C (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit.
-
Amplitude-distance spectroscopy in semi-contact mode
Open Research DataSince it was invented by Binnig et al. in 1986, atomic force microscopy (AFM) plays a key role in science and technology at the nanoscale. AFM is a microscopic technique that visualizes the surface topography using the attractive and repulsive forces of interaction between several atoms (in theory) of a blade attached to the end of the probe lever and...
-
FTIR spectra of reference SOFC fueled by H2 and 20ppm H2S/biogas mixture at 750 C - cyclic measurements (12h per cycle)
Open Research DataThe dataset contains the FTIR spectra collected during the cyclic measurements of H2S poisoning in DIR-SOFC without LSCNT layer. The H2S poisoning and H2 regenrating cycles were 12 h each. The spectra were collected every 10 min.
-
X-ray Photoelectron Spectroscopy studies of ammonium vanadate
Open Research DataThe DataSet contains the high-resolution XPS studies of the ammonium vanadate nanostructures obtained by the hydrothermal method. XPS analyses were carried out with an X-ray photoelectron spectrometer (Omicron NanoTechnology) with a 128-channel collector. The measurements were performed at room temperature in an ultra-high vacuum condition (below 1.1x10-8...
-
FTIR spectra of SOFC with LSCNT layer fueled by H2 and 20ppm H2S/biogas mixture at 750 C - cyclic measurements (12h per cycle)
Open Research DataThe dataset contains the FTIR spectra collected during the cyclic measurements of H2S poisoning in DIR-SOFC with LSCNT layer. The H2S poisoning and H2 regenrating cycles were 12 h each. The spectra were collected every 10 min.
-
Raman spectroscopy analysis of synthesized sol-gel silica coatings
Open Research DataThese data contains Raman spectra of silica coatings synthesized using sol-gel method A and B, which were described with publication associated with this dataset. Raman scattering was measured with a Renishaw microRaman spectrometer (830 nm).
-
Electrochemical Impedance Spectroscopy data of PDA-modified TiO2 nanotubes
Open Research DataThis dataset contains Electrochemical Impedance Spectroscopy data of the samples from TiO2 nanotubes modified with polydopamine. The studies were presented as a part of the research on "Band Gap Engineering toward Semimetallic Character of Quinone-Rich Polydopamine" (DOI: 10.1021/acs.jpcc.2c08804).
-
UV/VIS Spectroscopy of titanium dioxide coated nickel foams
Open Research DataThe data includes UV-Vis spectra of titanium dioxide coated nickel foams heated at 400, 500 and 600 C in Ar. Jasco V-650 Spectrophotometer was used and Spectra Measurement software.
-
X-ray Photoelectron Spectroscopy studies of salivary gland stones
Open Research DataThis dataset contains the high-resolution XPS studies for 23 cross-sections of salivary gland stones. The sialoliths were cut to determine the differences in composition between various regions: core (labeled as R), interlayer (labeled as P) and sialolith surface (labeled as Z).
-
Impedance spectroscopy of the lithium titanate doped by copper thin films
Open Research DataLithium titanate doped by copper thin films were derived by sol-gel method. Prepared gel was deposited by spin-coating technique. Samples with various content of Cu were measured by impedance spectroscopy method in a wide range of temperature, from -120 up to 150 deg.
-
Changes on the Surface of the SiO2/C Composite, Leading to the Formation of Conductive Carbon Structures with Complex Nature of DC Conductivity
Open Research DataChanges on the Surface of the SiO2/C Composite, Leading to the Formation of Conductive Carbon Structures with Complex Nature of DC Conductivity
-
Physicochemial data of the faceted anatase TiO2 nanoparticles
Open Research DataRaw XRD, DR-UVvis and FTIR data of the faceted TiO2 nanoparticles, as extracted from the source files. Description of the basic measurements conditions and used quipment included in the file.
-
Two-sites layered electrocatalysts for ammonia electrooxidation
Open Research DataThe dataset contains the results of the XRD and FTIR analysis of single metal layered α-Ni(OH)2, β-Ni(OH)2 or double metal layered NiCu hydroxides hydrothermally deposited on nickel foam.
-
Change of exhaust gases concentration for LSCNT modified SOFC fueled by biogas mixture at 750 C
Open Research DataThe dataset changes of exhaust gases concentrations (CH4,CO,CO2,H2) over working time for SOFC with La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s layer. Concentrations were calculated based on the FTIR measurements and calibration files presented in coupled dataset.
-
XPS (X-ray photoelectron spectroscopy) survey spectra of CPMD and CPMH
Open Research DataXPS (X-ray photoelectron spectroscopy) survey spectra of CPMD and CPMH. XPS spectra were obtained using Al Kɑ (hv=1486.6 eV) radiation with a Prevac system equipped with a Scienta SES 2002 electron energy analyzer operating at constant transmission energy (Ep=50 eV). Sample abbreviations (CPMD, CPMH) are in agreement with the markings used in the linked...
-
X-ray Photoelectron Spectroscopy studies of laser-induced titania nanotubes
Open Research DataThis dataset contains the results of high-resolution XPS studies obtained during the formation of the hollow nanopillar arrays through the laser-induced transformation of titania nanotubes.
-
The electrochemical impedance spectroscopy studies of cataphoretic-grown epoxy-based coatings
Open Research DataThe dataset contains electrochemical impedance spectroscopy spectra collected for epoxy-based cataphoretic coatings in order to determine the offered anti-corrosion protection. Particular spectra pertain to the coatings applied for the different magnitude of polarization potential imposed, namely 10V, 20V and 30V. The results were obtained within the...
-
X-Ray photoemission spectroscopy measurements of the Nb-V-Sr-O ceramics
Open Research DataNiobium doped strontium vanadate based perovskite SrV1-xNbxO3-δ materials were prepared via conventional solid state reaction (SSR) method. For comparison, different samples with a various amount of niobium dopant in the structure were synthesized; x = 0; 0,2; 0,5; 0,8 and 1. Samples were sintered by two-steps: first under a pure hydrogen (purity >99.999%)...
-
Structural and luminescence properties of B2O3-Bi2O3+10AlF3 glasses doped with Eu3+/Dy3+ ions
Open Research DataThe attached data contains the results of measurements of B2O3-Bi2O3 and B2O3-Bi2O3+10AlF3 glasses doped with Eu3+ and Dy3+ ions in different molar ratios. Glasses were synthesized by the melt quenching technique. On their basis, the structural, optical, and luminescence properties of synthesized samples were characterized. The dataset includes XRD,...
-
Change of exhaust gases concentration for reference SOFC and SOFC with LSCNT layer fueled by biogas mixture at 750 C
Open Research DataThe dataset changes of exhaust gases concentrations (CH4,CO,CO2,H2) over working time for SOFC with La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s layer as well as reference SOFEC (unmodified). Concentrations were calculated based on the FTIR measurements and calibration curves presented in different dataset. Longterm measurements of SOFC were performed using in-house...
-
Spectroscopy properties of 1,8-diazafluoren-9-one (DFO) in PVA polymer for different concentrations
Open Research DataSpectroscopy properties: absorption and fluorescence spectra of 1,8-diazafluoren-9-one (DFO) in PVA film for different concentrations of dye.
-
Influence of controlled crystallization and SrF2 content on the structure and properties of Eu3+ doped phosphate glasses
Open Research DataThe attached data contains the results of measurements of phosphate glasses and glass-ceramics doped with Eu. On their basis, the new material was characterized and the influence of the SrF2 addition on the glass structure was determined. In addition, the influence of the SrF2 content and controlled crystallization on the luminescent properties of Eu3+...
-
Change of catalytic parameters for SOFC fueled by H2 and biogas mixture at 750 C
Open Research DataThe dataset contains the Change of catalytic parameters for SOFC fueled by H2 and biogas mixture at 750 C (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit. The parameters are conversion rates, selectivities and yields of products
-
Carbon balance of SOFC fueled by biogas mixture at 750 C
Open Research DataThe dataset contains the calculated carbon balance for the SOFC fueled by synthetic biogas mixture (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit.
-
Raman spectroscopy analysis of poly(lactic acid)-carbon black composite treated by femtosecond laser
Open Research DataThe dataset contains the Raman spectroscopy measurements of commercially available carbon black-filled poly(lactic acid) 3D printed electrodes after femtosecond laser ablation. These results were utilized in the manuscript published in Electrochimica Acta: 10.1016/j.electacta.2022.140288
-
Dataset for systematic literature review about phosphorus magnetic resonance spectroscopy (31 P MRS).
Open Research DataThe file contains the publications retrived for systematic literature review from sleceted databases: Web of Science Core Collection, Scopus, Chochrane Library, and Pubmed. Records were identified by using nesting technique. Our search log stated as follow: "phosphorus" AND ("mri spectroscopy" OR "31P MRS").
-
Model dynamic electrochemical impedance spectroscopy (DEIS) results obtained with various DC polarization rates
Open Research DataThe dataset contains results of model dynamic electrochemical impedance spectroscopy studies carried out on a setup of 10 diodes in series, which were connected in parallel with a condenser. The impedance data were acquired every 1 s (the analytic window length for Fourier Transform was 1 s). The model system was polarized between 0 and +8 V with DEIS...
-
Nonlinear impedance of 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe nonlinear electrcial properties of 50(Bi2VO5.5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Reduction of the strontium titanate doped by Ytrium ceramics observed by X-ray photoemission spectroscopy method
Open Research DataYtrium-doped strontium titanate (YSTF) ceramics materials were manufactured by three various methods: 1) standard solid-state reaction method from Y2O3 (Sigma Aldrich, 99,9%), TiO2 (Sigma Aldrich, 99%) and SrCO3 (Sigma Aldrich,98%), 2) Pechini method, 3) wet method.
-
Nonlinear impedance of 35Bi2VO5.5-65SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 35Bi2VO5.5-65SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 30Bi2VO5.5-70SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 30Bi2VO5.5-70SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 50(Bi2VO5.5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of Bi2VO5.5 glass-ceramic measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of Bi2VO5.5 glass-ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Nonlinear impedance of 45Bi2VO5.5-55SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 45Bi2VO5.5-55SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 50Bi2VO5.5-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Carbon activity coefficients of SOFC and SOFC with LSCNT layer fueled by biogas mixture at 750 C - longterm
Open Research DataThe dataset contains the calculated carbon activity coefficient for the SOFC and SOFC with LSCNT layer (La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s) fueled by synthetic biogas mixture (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit.
-
X-ray Photoelectron Spectroscopy (XPS) results of bulk boron and borophene after the ball-milling process
Open Research DataThese data contain X-ray Photoelectron Spectroscopy (XPS) results of boron and borophene nanoflakes induced during ball milling at rotation speed of 450 rpm, 6 h and mass loading of 1g.
-
Broadband dielectric spectroscopy studies of multiple times processed poly(lactic acid)-carbon black composites
Open Research DataThis dataset contains broadband dielectric spectroscopy studies of commercially available ProtoPasta 3D printable filament, composed of poly-lactic acid (PLA) and conductive carbon black (CB) filler. The aim of the study is to observe structural differences and applied properties changes under multiple reprocessing of the composite material at different...
-
XPS (X-ray photoelectron spectroscopy) of titanium dioxide coated nickel foams and heated 400,500, 600C
Open Research DataThis data set contains XPS spectra recorded for nickel foams coated with titanium dioxide and heated at 400, 500 and 600 degrees celcius.
-
X-ray photoelectron spectroscopy (XPS) results for nickel(II) oxide (NiO) functionalized borophene and boron
Open Research DataThis dataset contain X-ray photoelectron spectroscopy (XPS) results for nickel(II) oxide (NiO) functionalized borophene before and after oxygen evolution reacion (OER) nad bulk boron.
-
X-ray Photoelectron Spectroscopy studies of citric acid adsorption on aluminium alloy 5754 in alkaline media
Open Research DataThis dataset contains the results of high-resolution XPS obtained during evaluation of high corrosion inhibition efficiency of citric acid towards aluminium alloy 5754 in bicarbonate buffer pH=11. The exposition duration of samples to electrolytic environment was 100 min. Each sample was exposed at different citric acid concentration ranging from 0...
-
X-ray Photoelectron Spectroscopy studies of various carboxylic acids adsorption on aluminium alloys in alkaline media
Open Research DataThis dataset contains the results of high-resolution XPS studies obtained during evaluation of high corrosion inhibition efficiency of various carboxylic acids towards aluminium alloy 5754 in bicarbonate buffer pH=11.
-
Nonlinear impedance of as-quenched Bi2VO5.5 glass-ceramic was measured with impedance spectroscopy method at low temperature region
Open Research DataThe nonlinear electrical properties of as-quenched Bi2VO5.5 glass-ceramic was measured by impedance spectroscopy method.
-
Linear impedance of as-quenched 40Bi2VO5.5-60SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 40Bi2VO5.5-60SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 10Na2O–60P2O5–30CaO glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of 10Na2O–60P2O5–30CaO glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of as-quenched 40Bi2VO5.5-60SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of as-quenched 40Bi2VO5.5-60SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 40Na2O-20CaO-40P2O5 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of 40Na2O-20CaO-40P2O5 glass was measured by impedance spectroscopy method.
-
Reaction quotients of reforming reactions for SOFC and SOFC with LSCNT layer fueled by biogas mixture at 750 C - longterm
Open Research DataThe dataset contains the calculated reaction quotients of reforming reactions for the SOFC and SOFC with LSCNT layer (La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s) fueled by synthetic biogas mixture (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit.
-
Analytical data on molecular umbrella: cispentacin and molecular umbrella: fluorescent probe conjugates
Open Research DataAnalytical data (NMR, MS, FTIR) for nine conjugates of molecular umbrella with cispentacin, Lys(Mca) or Nap-NH2. The conjugates have been rationally designed as potential antifungal agents. 1H NMR and 13C NMR spectra were obtained at 500 MHz Varian Unity Plus spectrometer and the deuterated solvents were used as internal locks. High-resolution mass...
-
Electrochemical impedance spectroscopy measurements - conductivity vs. temperature and conductivity vs. oxygen partial pressure - BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataThe dataset consists of two main catalogs consisting of measurement data: of the electrical conductivity of the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ (BCZYTb) sample as a function of temperature and of the electrical conductivity as a function of oxygen partial pressure (pO2). Measurements as a function of temperature were carried out in dry and wet air (pH2O ~...
-
Nonlinear impedance of 45Bi2VO5.5-55SrB4O7 fully crystallized glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 45Bi2VO5.5-55SrB4O7 fully crystallized glass was measured by impedance spectroscopy method.
-
Linear impedance of Bi2VO5.5 ceramic of thickness 2.88 mm measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of Bi2VO5.5 ceramic of thickness 2.88 mm was measured by impedance spectroscopy method.
-
Linear impedance of 5(2Bi2O3-V2O5)-95SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties of 5(2Bi2O3-V2O5)-95SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 35Bi2VO5.5-65SrB4O7 fully crystallized glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 35Bi2VO5.5-65SrB4O7 fully crystallized glass was measured by impedance spectroscopy method.
-
Linear impedance of 25Na2O–20CaO–5P2O5–50SiO2 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of 25Na2O–20CaO–5P2O5–50SiO2 glass was measured by impedance spectroscopy method.
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 5(2Bi2O3-V2O5)-95SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 5(2Bi2O3-V2O5)-95SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 5(2Bi2O3-V2O5)-95SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 5(2Bi2O3-V2O5)-95SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of Bi2VO5.5 ceramic of thickness 2.52 mm measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of Bi2VO5.5 ceramic of thickness 2.52 mm was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe nonlinear electrcial properties of 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 30Bi2VO5.5-70SrB4O7 fully crystallized glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 30Bi2VO5.5-70SrB4O7 fully crystallized glass was measured by impedance spectroscopy method.
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method
Open Research DataThe linear electrcial properties as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.