Filters
total: 13887
filtered: 10454
-
Catalog
- Publications 10454 available results
- Journals 87 available results
- Conferences 15 available results
- Publishing Houses 1 available results
- People 119 available results
- Projects 1 available results
- Research Equipment 1 available results
- e-Learning Courses 91 available results
- Events 8 available results
- Open Research Data 3110 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: BLOOD PRESSURE, PULSE TRANSIT TIME, NONINVASIVE MEASUREMENTS, SAMPLING FREQUENCY, LOW PASS FILTER
-
Multi-pulse VSC arrangements with coupled reactors
PublicationThis paper presents a novel approach to the multipulse VSC (Voltage Source Converter) arrangements based on several conventional inverter modules connected in parallel by using coupled reactors. This solution reduces the THD of the output voltage, despite the low switching frequency of transistors. The advantage of the proposed solution is also a relatively small rated power of the reactors. Proposed new arrangements for different...
-
Shipping Low Frequency Noise and Its Propagation in Shallow Water
PublicationOne of the most significant factor influencing acoustical climate of the sea is underwater noise generated by moving ships. If the considered sea area has features of the shallow water, namely the wave frequency fulfils relation f < 10c/h, where c denotes phase speed of sound, and h is depths of the sea, then in certain distance from the wave source specific image of sound pressure distribution in the mean of wave modes appears....
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublicationAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
Implementation of Extended Kalman Filter with Optimized Execution Time for Sensorless Control of a PMSM Using ARM Cortex-M3 Microcontroller
PublicationThis paper addresses the implementation and optimization of an Extended Kalman Filter (EKF) for the Permanent Magnet Synchronous Motor (PMSM) sensorless control using an ARM Cortex-M3 microcontroller. A various optimization levels based on arithmetic calculation reduction was implemented in ARM Cortex-M3 microcontroller. The execution time of EKF estimator was reduced from 260.4 μs to 37.7 μs without loss of accuracy. To further...
-
Masked hypertension in type 2 diabetes: never take normotension for granted and always assess out-of-office blood pressure
Publication -
The J-curve phenomenon revisited again: SPRINT outcomes favor target systolic blood pressure below 120 mmHg
Publication -
From the multiple frequency tracker to the multiple frequency smoother
PublicationThe problem of extraction/elimination of nonstationary sinusoidalsignals from noisy measurements is considered. This problem is usually solved using adaptive notch filtering (ANF)algorithms. It is shown that the accuracy of frequency estimates can be significantly increased if the results obtained from ANF are backward-time filtered by an appropriately designed lowpass filter. The resulting adaptive notch smoothing (ANS)algorithm...
-
Which Target Blood Pressure in Year 2018? Evidence from Recent Clinical Trials
Publication -
Coupling between Blood Pressure and Subarachnoid Space Width Oscillations during Slow Breathing
PublicationThe precise mechanisms connecting the cardiovascular system and the cerebrospinal fluid (CSF) are not well understood in detail. This paper investigates the couplings between the cardiac and respiratory components, as extracted from blood pressure (BP) signals and oscillations of the subarachnoid space width (SAS), collected during slow ventilation and ventilation against inspiration resistance. The experiment was performed on...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublicationIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
Blood pressure in acute ischemic stroke
Publication -
Rating mathematical models for first-pass of tracer in pCT lung studies
PublicationThis paper presents a comparison of model based on the Gauss function and the most commonly used Gamma-variate model in perfusion computed tomography (pCT) lung studies. It also verifies whether used model affects value of blood volume parameter. Three mean concentration-time curves were created from actual pCT measurements: arterial input function, blood vessels in lungs and lung parenchyma. On the basis of these mean curves we...
-
Non-invasive hemodynamic monitoring as a guide to drug treatment of uncontrolled hypertensive patients: effects on home blood pressure in the BEAUTY study
Publication -
A robust 18-pulse diode rectifier with coupled reactors
PublicationThe article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...
-
Sensitivity performance of all pole canonical low pass GmC filters.
PublicationW pracy badano własności częstotliwościowe kanonicznych filtrów dolnoprzepustowych GmC bez zer transmisyjnych. Przedstawiono ogólną strukturę kanonicznego filtru dolnoprzepustowego i jej opis macierzowy. Wyprowadzono ogólne wzory określające funkcje wrażliwościowe filtru. Dokonano porównania struktur do 10-go rzędu włącznie dla aproksymacji Butterwortha, Czebyshewa i Bessela.
-
Low-Cost Data-Driven Surrogate Modeling of Antenna Structures by Constrained Sampling
PublicationFull-wave electromagnetic (EM) analysis has become one of the major design tools for contemporary antenna structures. Although reliable, it is computationally expensive which makes automated simulation-driven antenna design (e.g., parametric optimization) difficult. This difficulty can be alleviated by utilization of fast and accurate replacement models (surrogates). Unfortunately, conventional data-driven modeling of antennas...
-
TIME- AND FREQUENCY-DOMAIN QUASI-2D SMALL-SIGNAL MOSFET MODELS
PublicationA novel approach to small-signal MOSFET modeling is presented in this book. As a result, time- and frequency-domain physics-based quasi-2D NQS four-terminal small-signal MOSFET models are proposed. The time-domain model provides the background to a novel DIBL-included quasi‑2D NQS four-terminal frequency-domain small-signal MOSFET model. Parameters and electrical quantities of the frequency-domain model are described by explicit...
-
Determination of time delay between ventricles contraction using impedance measurements
PublicationThe paper presents a novel approach to assessment of ventricular dyssynchrony basing on multichannel electrical impedance measurements. Using a proper placement of electrodes, the sensitivity approach allows estimating time difference between chambers contraction from over determined nonlinear system of equations. The theoretical considerations which include Finite Element Method simulations were verified using measurements on...
-
Dead-Time Effect Compensation Based on Additional Phase Current Measurements
PublicationThis paper proposes a new method of dead-time effect compensation. The proposed solution is based on additional phase current measurements realized by analog-to-digital converters. These measurements are carried out at the time instants specified by a pulsewidth-modulation (PWM) strategy. This makes it possible to estimate inverter currents at the commutation instants and, finally, to estimate the voltage error caused by dead time. This...
-
[PP.17.01] INCREASED INSPIRATORY RESISTANCE AFFECTS THE CARDIAC CONTRIBUTION TO THE RELATIONSHIP BETWEEN BLOOD PRESSURE AND PIAL ARTERY PULSATION OSCILLATIONS
PublicationThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance would affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
A novel method of local chirp-rate estimation of LFM chirp signals in the time-frequency domain
PublicationIn the paper, novel dynamic representations of a complex signal in the time-frequency domain are introduced. The proposed approach is based on using the gradient of the short-time Fourier transform complex phase. A channelized instantaneous complex frequency (CICF) and a complex local group delay (CLGD) are included in the presented signal representations. An application of the newly-introduced distributions is demonstrated by...
-
Low-frequency noise in ZrS3 van der Waals semiconductor nanoribbons
PublicationWe report the results of the investigation of low-frequency electronic noise in ZrS3 van der Waals semiconductor nanoribbons. The test structures were of the back-gated field-effect-transistor type with a normally off n-channel and an on-to-off ratio of up to four orders of magnitude. The current–voltage transfer characteristics revealed significant hysteresis owing to the presence of deep levels. The noise in ZrS3 nanoribbons...
-
Impact of Low Switching-to-Fundamental Frequency Ratio on Predictive Current Control of PMSM: A simulation study
PublicationPredictive current control algorithms for permanent magnet synchronous (PMSM) drives rely on an assumption that within short intervals motor currents can be approximated with linear functions. This approximation may result either from discretizing the motor model or from simplifications applied to the continuous-time model. As the linear current approximation has been recognized as inaccurate in case when the drive operates with...
-
Systolic blood pressure control prevents cognitive decline and slows development of white matter lesions in the brain: the SPRINT MIND study outcomes
Publication -
Independent dynamics of low, intermediate, and high frequency spectral intracranial EEG activities during human memory formation
PublicationA wide spectrum of brain rhythms are engaged throughout the human cortex in cognitive functions. How the rhythms of various frequency ranges are coordinated across the space of the human cortex and time of memory processing is inconclusive. They can either be coordinated together across the frequency spectrum at the same cortical site and time or induced independently in particular bands. We used a large dataset of human intracranial...
-
Decoupled Kalman filter based identification of time-varying FIR systems
PublicationWhen system parameters vary at a fast rate, identification schemes based on model-free local estimation approaches do not yield satisfactory results. In cases like this, more sophisticated parameter tracking procedures must be used, based on explicit models of parameter variation (often referred to as hypermodels), either deterministic or stochastic. Kalman filter trackers, which belong to the second category, are seldom used in...
-
Performance Measurements of Real Time Video Transmission from Car Patrol
PublicationThe HSUPA technology application to video streaming from moving vehicle to the central server is presented in the paper. A dedicated software for transmission control in case of non public IP address is employed. Quality of video streaming in urban area was measured. Several car routes were investigated in the area of the Polish Tricity. Measurements pointed out that the real time streaming quality during vehicle movement is sufficient...
-
Noise measurements on low noise pavements - problems with inhomogeneity of wearing course
PublicationDuring the last several years, when performing numerous CPX noise measurements on low noise pavements,significant inhomogeneity of the wearing course was observed in numerous cases. Similar problems were almost not existing regarding to the dense pavements.In general three main reasons of inhomogeneity can be defined. The first one are imperfections in technology of production of a asphalt mix or/and errors made already during...
-
Low-frequency noise in Au-decorated graphene–Si Schottky barrier diode at selected ambient gases
PublicationWe report results of the current–voltage characteristics and low-frequency noise in Au nanoparticle (AuNP)-decorated graphene–Si Schottky barrier diodes. Measurements were conducted in ambient air with addition of either of two organic vapors, tetrahydrofuran [(CH2)4O; THF] and chloroform (CHCl3), as also during yellow light illumination (592nm), close to the measured particle plasmon polariton frequency of the Au nanoparticle...
-
Increased inspiratory resistance alters the cardiac contribution to the dynamic relationship between blood pressure and pial artery pulsation oscillations in healthy subjects
PublicationThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance will affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
A Low-Cost System for Far-Field Non-Anechoic Measurements of Antenna Performance Figures
PublicationPrototype measurements are the key step in the development of antenna structures. Typically, their far-field characteristics are validated in expensive, dedicated facilities such as open range sites, or anechoic chambers. Despite being necessary for obtaining high-precision data (e.g., for device qualification), the use of costly infrastructure might not be fully justified when the main goal of measurements includes demonstration...
-
Validation of a sampling procedure
PublicationEach step of the analytical procedure influences the final results in a significant way. In the majority of cases the analytical procedure encompasses sampling because the analysis of the entire object (material) is usually not possible. Thus it is necessary to include the uncertainty related to sampling procedure in the uncertainty budget calculations. This paper describes two basic ways of estimating the sampling uncertainty,...
-
Blood equivalent phantom vs whole human blood, a comparative study
PublicationPreclinical research of biomedical optoelectronic devices is often performed with the use of blood phantoms — a simpli¯ed physical model of blood. The aim of this study is the comparison and distinction between blood phantoms as well as whole human blood measurements. We show how the use of such phantoms may in°uence the incorrect interpretation of measured signal. On the other hand, we highlight how the use of blood phantoms enables...
-
Measuring Pulse Rate with a Webcam
PublicationIn this paper a simple method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face images captured from a webcam. The desired signal is obtained by proper channel selection and principal component analysis. To determine the accuracy of the method an ECG signal is collected together with a video recordings. The effectiveness of the algorithm is considered...
-
Renal denervation achieved by endovascular delivery of ultrasound in RADIANCE-HTN SOLO or by radiofrequency energy in SPYRAL HTN-OFF and SPYRAL-ON lowers blood pressure
Publication -
The measurement of input power of power supply in network disturbed by low frequency distortions
PublicationIn the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed
-
A simulation investigation into the signal reconstruction accuracy of the transducer with pulse frequency output
Publication -
Microstrip line with short-circuited edge as a high-pass filter operating up to millimeter-wave frequencies
PublicationPrzedstawiono prosty planarny filtr górnoprzepustowy wykorzystujący linię mikropaskową ze zwartym brzegiem. Układy zaprojektowano w taki sposób, aby pasmo przepustowe rozpoczynało się w zakresie K lub Ka. Wykonano dwa prototypy: na podłożu w postaci warstwy dielektrycznej wykonanej z ceramiki alundowej oraz na podłożu organicznym o niskiej przenikalności elektrycznej. Wykazano dużą zgodność teoretycznych i pomierzonych charakterystyk...
-
Multi-layered tissue head phantoms for noninvasive optical diagnostics
PublicationExtensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical...
-
Multifunctional Bandpass Filter/Displacement Sensor Component
PublicationThis paper presents the design and realization of a multifunctional bandpassfilter/displacement-sensor using an edge-coupled microstrip bandpass filter loaded by a pair of split ring resonators (SRRs). It is shown that while the structure acts as a bandpass filter at its operating frequency, the phase of the reflection coefficient from a movable loading resonator at the resonance frequency of the resonator can be used for displacement...
-
Inhomogeneity of low-noise wearing courses evaluated by tire/road noise measurements using the close-proximity method
PublicationPerforming numerous analyses of tire/road noise measurements on low-noise pavements during the last several years, the authors observed significant inhomogeneity of the wearing course in numerous cases, while similar problems were almost non-existent when dense pavements were measured. Three main causes of low-noise pavement inhomogeneity can be defined. The first one is imperfections in the technology used for asphalt mix production...
-
Temporal Changes in Complexity of Cardiovascular Regulation during Head-Up Tilt Test by Entropic Measures of Fluctuations of Heart Period Intervals and Systolic Blood Pressure
PublicationTemporal changes in complexity of cardiovascular regulation during head-up tilt test by entropic measures of fluctuations of heart period intervals and systolic blood pressure
-
Nonlinear generation of non-acoustic modes by low-frequency sound in a vibrationally relaxing gas
PublicationTwo dynamic equations referring to a weakly nonlinear and weakly dispersive flow of a gas in which molecular vibrational relaxation takes place. are derived. The first one governs an excess temperature associated with the thermal mode, and the second one describes variations in vibrational energy. Both quantities refer to non-wave types of gas motion. These variations are caused by the nonlinear transfer of acoustic energy into...
-
Modelling of Asphalt Mixes under Long Time Creep at Low Temperatures
PublicationProper description of asphalt mixtures behavior under long time load is one of the most important factors in analyses of strain and stress relations at low temperatures both from traffic and environmental loads. For example different models of thermal stress accumulation require different approaches of description of asphalt concrete. But in all cases it is required to describe its behavior under long time loading, which in some...
-
A Case for Less Intensive Blood Pressure Control: It Matters to Achieve Target Blood Pressure Early and Sustained Below 140/90mmHg
Publication -
A new time-frequency detection method of stray current field interferenceon metal structures.
PublicationA new detection method has been presented of stray current field interference on underground metal structures. The method employs short time Fourier transformation (STFT). This method of analysis allows determination of signal spectral power density changes (e.g., structure potential) in the function of time. In the paper results have been presented of total time–frequency analysis of a pipeline potential in a stray current field...
-
A hybrid, coupled reactors based 18-pulse diode rectifier with active power filter
Publication -
Five-phase induction motor drive with sine-wave filter
PublicationThe paper presents closed loop ac drive with 5 phase induction motor operating with voltage source inverter and sine wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed co ntrol can be applied. In the presence of output filter both control and estimation algorithms should be modified due to sine wave filter installation....
-
Filter-Hilbert Method for Automatic Correction of Non-Anechoic Antenna Measurements with Embedded Self-Calibration Mechanism
PublicationOne of the most important steps in the process of antenna development involves measurements of its prototype. Far-field performance of radiators is normally characterized in strictly controlled environments such as anechoic chambers which can ensure certification-grade accuracy. Unfortunately, they are also characterized by high construction costs which might not be justified for low-budget research and/or teaching-related activities....
-
The Low-frequency Noise of SiC MESFETs
PublicationPrzedstawiono system do pomiaru szumów małoczestotliwościowych tranzystorów SiC MESFET oraz przykładowe wyniki pomiarów.