Filters
total: 2289
filtered: 1963
-
Catalog
- Publications 1963 available results
- Journals 31 available results
- Conferences 11 available results
- Publishing Houses 1 available results
- People 27 available results
- Projects 5 available results
- e-Learning Courses 15 available results
- Events 1 available results
- Open Research Data 235 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: ELECTROCATALYTIC GAS SENSOR
-
Investigation of Taste Substances by five Channel Lipid-Polymer Membrane Sensor.
PublicationBadano substancje o różnych stężeniach należące do czterech klas smaku za pomocą pięcio-kanałowego sensora opartego o elektrody jonoselektywne z różnymi membranami polimerowo-lipidowymi. Stwierdzono, że sensor jest czuły na zmiany stężeń chlorowodorku chininy, kawsu cytrynowego i chlorku sodu, przeciwnie jak w przypadku sacharozy. Na podstawie tych wyników można przypuszczać, że sensor może być zastosowany do roztworów składających...
-
Suppression of distortions in signals received from Doppler sensor for vehicle speed measurement
PublicationDoppler sensors are commonly used for movement detection and speed measurement. However, electromagnetic interference and imperfections in sensor construction result in degradation of the signal to noise ratio. As a result, detection of signals reflected from moving objects becomes problematic. The paper proposes an algorithm for reduction of distortions and noise in the signal received from a simple, dual-channel type of a Doppler...
-
Localization in wireless sensor networks using switched parasitic antennas
PublicationA switched parasitic monopole antenna for 2.4 GHz ISM applications is design and investigated in this paper. One of the most promising applications for such switched-beam antennas is localization in wireless sensor networks (WSN). It is demonstrated that the use of this antenna improves accuracy of localization algorithms and allows for reduction of the number of reference nodes in localization system.
-
A Microwave Sensor with Operating Band Selection to Detect Rotation and Proximity in the Rapid Prototyping Industry
PublicationThis paper presents a novel sensor for detecting and measuring angular rotation and proximity, intended for rapid prototyping machines. The sensor is based on a complementary split-ring resonator (CSRR) driven by a conductor-backed coplanar waveguide. The sensor has a planar topology, which makes it simple and cost-effective to produce and accurate in measuring both physical quantities. The sensor has two components, a rotor, and...
-
Sandwich Biobattery with Enzymatic Cathode and Zinc Anode Integrated with Sensor
PublicationCarbon paper covered with side-naphthylated multi walled carbon nanotubes was used as the conducting support for the construction of a biocathode in a hybrid biofuel cell. Laccase Carrena unicolor enzyme was employed as the catalyst for the 4e reduction of oxygen and a zinc disc covered with hopeite was used as the anode. Derivatized carbon nanotubes increase the working surface of the electrode and provide direct contact with...
-
Microscale diamond protection for a ZnO coated fiber optic sensor
PublicationFiber optic sensors are widely used in environmental, biological and chemical sensing. Due to the demanding environmental conditions in which they can be used, there is a risk of damaging the sensor measurement head placed in the measuring field. Sensors using nanolayers deposited upon the fiber structure are particularly vulnerable to damage. A thin film placed on the surface of the fiber end-face can be prone to mechanical damage...
-
Calibration of acoustic vector sensor based on MEMS microphones for DOA estimation
PublicationA procedure of calibration of a custom 3D acoustic vector sensor (AVS) for the purpose of direction of arrival (DoA) estimation, is presented and validated in the paper. AVS devices working on a p-p principle may be constructed from standard pressure sensors and a signal processing system. However, in order to ensure accurate DoA estimation, each sensor needs to be calibrated. The proposed algorithm divides the calibration process...
-
Pose classification in the gesture recognition using the linear optical sensor
PublicationGesture sensors for mobile devices, which have a capability of distinguishing hand poses, require efficient and accurate classifiers in order to recognize gestures based on the sequences of primitives. Two methods of poses recognition for the optical linear sensor were proposed and validated. The Gaussian distribution fitting and Artificial Neural Network based methods represent two kinds of classification approaches. Three types...
-
A compact smart sensor based on a neural classifier for objects modeled by Beaunier's model
PublicationA new solution of a smart microcontroller sensor based on a simple direct sensor-microcontroller interface for technical objects modeled by two-terminal networks and by the Beaunier’s model of anticorrosion coating is proposed. The tested object is stimulated by a square pulse and its time voltage response is sampled four times by the internal ADC of microcontroller. A neural classifier based on measurement data classifies the...
-
Perforating systems in shale gas recovery
PublicationHydraulic fracturing is common method of shale gas recovery. Due to environmental, economical and technological problems many alternative technologies have been developed. One of the most promising group of technologies is based on perforating systems. This paper describes theoretical and practical aspects of best known technologies used to create perforations. New perforating/fracturing technologies which can replace hydraulic fracturing...
-
A novel concept for tissue-metal detection and differentiation using an inductive proximity sensor
PublicationIn this paper a novel application of inductive proximity sensors for detection of living tissue by means of measurements of the coil impedance changes at different frequencies is described. The mathematical analyses utilizing Bessel function estimation include detected object size and its distance from a sensor. The main aim of this study is to prove the possibility of distinguishing between metal objects and living tissues. The...
-
Chapter 11 – Application of Chemical Sensors and Sensor Matrixes to Air Quality Evaluation
PublicationIndoor and outdoor air quality is one of the key factors influencing human health. However, air quality evaluation is not easy task. Air is a complex system, which is subjected to changes even within short period of time. Progress in analytical methods and analytical tools provides increasingly more reliable information on the condition and quality of indoor and outdoor air. This progress, however, generates an increase in the...
-
Exhaust gas temperature measurements in diagnostic examination of naval gas turbine engines. Part I: Steady-state processes
PublicationThe article presents a possible method of detecting failures in the flow section and supply system of a naval gas turbine engine based on the exhaust gas temperature measured behind the gas generator. This temperature is a basic diagnostic parameter use for evaluating the technical state of the turbine engine in operation, and is monitored during engine start-ups, accelerations and decelerations of rotor units, and steady-load...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublicationIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
Noise spectral density computation based on finite element model of piezoceramic sensor
PublicationThe high sensitivity with wide bandwidth is required for sensor applications in non-destructive testing (NDT). The sensitivity of piezoceramic sensors demands to minimize their noise especially thermal noise, polarisation noise and low frequency 1/f noise,which are the main sources of voltage or current fluctuation in this sort of sensors. For simplicity, only the piezoceramic part of sensor was under study. the theoretical and...
-
Sensor Position Estimation Method for IoT Using Mobile Reference Node
PublicationThe paper proposes an innovative method of locating objects for the Internet of Things (IoT). The proposed method allows the position of a fixed measuring sensor (MS) to be estimated using one mobile base station with a known position moving around the MS. The mathematical analysis of the method, and three algorithms — Newton’s (NA), gradient descent (GD) and genetic (GA) — for solving the system of non-linear positional equations...
-
Investigation of Sensing Mechanism of Nasicon Electrocatalytic Sensors in Nitrogen Dioxide and Ammonia
PublicationW pracy przedstawiono wyniki badań mechanizmu działania czujnika elektrokatalitycznego pracującego w ditlenku azotu i amoniaku.
-
APPLICABILITY OF INLET AIR FOGGING TO MARINE GAS TURBINE
PublicationThe dependency of marine gas turbine on the ambient temperature leads to a decrease of the gas turbine power output in arid areas. Very often gas turbine power output demand is high and the power margins originally designed into the driver , has been exhausted. In such circumstances the inlet air fogging is an effective compensation of gas turbine power. In this paper an analysis of inlet air fogging applicability to marine gas...
-
Determination of vertical displacements by using the hydrostatic levelling systems with the variable location of the reference sensor,
PublicationAbstract: In this paper, the author proposed a new method for determination of vertical displacements with the use of hydrostatic levelling systems. The traditional method of hydrostatic levelling uses a rule in which a position of reference sensor is stable. This assumption was not adapted in the proposed method. Regarding the issue mentioned above, the reference sensor is treated in the same way as the others sensors that measure...
-
Dopants and gas modifiers in ion mobility spectrometry
PublicationThe ion mobility techniques, including the most commonly used drift-tube ion mobility spectrometry (IMS) and differential mobility spectrometry (DMS), are used successfully for the detection of a wide range of organic compounds in the gas phase. In order to improve detection quality, admixtures are added to gas streams flowing through the detector. Dopants mostly prevent the ionization of interfering chemicals however, better detection...
-
DETERMINING THE TIME CONSTANT USING TWO METHODS AND DEFINING THE THERMOCOUPLE RESPONSE TO SINE EXCITATION OF GAS TEMPERATURE
PublicationThis paper describes the two methods of determining the time constant of type K thermocouple, for two construction solutions: the exposed weld and the mantle fillet weld. This is an important parameter indicating the response time of the thermocouple on the recorded signal. The first method consists of determining the value of τ in the way of numerical simulation of heat exchange between the thermocouple and the current of gas...
-
Design Analysis of Micro Gas Turbines in Closed Cycles
PublicationThe problems faced by designers of micro-turbines are connected with a very small volume flow rate of working media which leads to small blades’ height and high rotor speed. In the case of gas turbines this limitation can be overcome by the application of a closed cycle with very low pressure at the compressor inlet (lower than atmospheric pressure). In this way we may apply a micro gas turbine unit of accepted efficiency to work...
-
Exhaled breath analysis by resistive gas sensors
PublicationBreath analysis has attracted human beings for centuries. It was one of the simplest methods to detect various diseases by using human smell sense only. Advances in technology enable to use more reliable and standardized methods, based on different gas sensing systems. Breath analysis requires the detection of volatile organic compounds (VOCs) of the concentrations below individual ppm (parts per million). Therefore, advanced detection...
-
Sulfur compounds: Gas chromatography
PublicationSulfur compounds, due to their properties, are responsible for the damage of our environment. For this reason sulfur containing compounds are of constant concern in many fields. Gas chromatography (GC), due to combination of separation capability and sensitive detection is a prime technique for the analysis of thes compounds in various matrices. The chapter rewies general problems of the determination of these compounds by GC and...
-
Gesture Recognition With the Linear Optical Sensor and Recurrent Neural Networks
PublicationIn this paper, the optical linear sensor, a representative of low-resolution sensors, was investigated in the multiclass recognition of near-field hand gestures. The recurrent neural network (RNN) with a gated recurrent unit (GRU) memory cell was utilized as a gestures classifier. A set of 27 gestures was collected from a group of volunteers. The 27 000 sequences obtained were divided into training, validation, and test subsets....
-
New developments in preparation and use of standard gas mixtures
PublicationStandard gas mixtures are commonly applied in all stages of analytical work related to the analysis of gaseous samples. Numerous techniques for generating standard gas mixtures are in use. In this article, we present new developments regarding the production of standard gas mixtures, with particular focus on improvements in the application of dynamic techniques for generating them. Furthermore, we describe the application of new...
-
Non-Gaussian Resistance Fluctuations in Gold-Nanoparticle-Based Gas Sensors: An Appraisal of Different Evaluation Techniques
PublicationVolatile organic compounds, such as formaldehyde, can be used as biomarkers in human exhaled breath in order to non-invasively detect various diseases, and the same compounds are of much interest also in the context of environmental monitoring and protection. Here, we report on a recently-developed gas sensor, based on surface-functionalized gold nanoparticles, which is able to generate voltage noise with a distinctly non-Gaussian...
-
Resistive gas sensors – Perspectives on selectivity and sensitivity improvement
PublicationResistive gas sensors are very popular and relatively inexpensive; they can operate at elevated or room temperature for years on end. The main disadvantage of resistive gas sensors is their limited selectivity and sensitivity, but various methods have been applied to improve their behavior. The composition of the porous gas sensing layer, or changes in the sensor’s operating temperature, can enhance the gas detection ability. Furthermore, emerging...
-
Exhaust gas temperature measurements in diagnostic examination of naval gas turbine engines. Part III. Diagnostic and operating tolerances
PublicationThe third part of the article presents a method for detecting failures of the automatic engine control system with the aid of an exhaust gas temperature setter, specially designed and machined for this purpose. It also presents a procedure of identifying the operating tolerances and determining the diagnostic tolerances for the exhaust gas temperature recorded in the naval turbine engine during the start-up and acceleration processes....
-
Exhaust gas temperature measurements in diagnostic examination of naval gas turbine engines. Part II. Unsteady processes
PublicationThe second part of the article presents the results of operating diagnostic tests of a two- and three-shaft engine with a separate power turbine during the start-up and acceleration of the rotor units. Attention was paid to key importance of the correctness of operation of the automatic engine load control system, the input for which, among other signals, is the rate of increase of the exhaust gas flow temperature. The article...
-
Determination of long-chain aldehydes using a novel quartz crystal microbalance sensor based on a biomimetic peptide
PublicationThere is an increasingly popular trend aimed at improvement of fundamental metrological parameters of sensors via implementation of materials mimicking biological olfactory systems. This study presents investigation on usefulness of the peptide mimicking HarmOBP7 region as a receptor element of the piezoelectric sensor for selective analysis of long-chain aldehydes. Identification of odorant binding proteins creates new possibilities...
-
Photonic sensor to detect rapid changes in CRP levels
PublicationOne of the most important biomarkers used to determine inflammation is C-reactive protein (CRP). Its level, when it is within the range that does not define inflammation, informs about the risk of cardiovascular events. If the norm is exceeded and inflammation is detected in the body, CRP level can increase 1000 times within a few hours. The type of infection can also be determined based on the level of elevated CRP. All this makes...
-
Detection of Water on Road Surface with Acoustic Vector Sensor
PublicationThis paper presents a new approach to detecting the presence of water on a road surface, employing an acoustic vector sensor. The proposed method is based on sound intensity analysis in the frequency domain. Acoustic events, representing road vehicles, are detected in the sound intensity signals. The direction of the incoming sound is calculated for the individual spectral components of the intensity signal, and the components...
-
Support for Employees with ASD in the Workplace Using a Bluetooth Skin Resistance Sensor–A Preliminary Study
PublicationThe application of a Bluetooth skin resistance sensor in assisting people with Autism Spectrum Disorders (ASD), in their day-to-day work, is presented in this paper. The design and construction of the device are discussed. The authors have considered the best placement of the sensor, on the body, to gain the most accurate readings of user stress levels, under various conditions. Trial tests were performed on a group of sixteen...
-
A New Approach to Capacitive Sensor Measurements Based on a Microcontroller and a Three-Gate Stable RC Oscillator
PublicationA complete smart capacitive sensor solution basedA complete smart capacitive sensor solution based on a microcontroller was developed. This approach includes the development of both the hardware and software. The hardware part comprises an 8-bit microcontroller equipped with two timers/counters and a three-gate stable RC relaxation oscillator. The software part handles system configuration, measurement control, communication control,...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublicationIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
A comparative study of pentanol (C5 alcohol) and kerosene blends in terms of gas turbine engine performance and exhaust gas emission
PublicationThe growing demand for sustainable and clean energy sources provides the incentive for the development of alternative fuels. Simultaneously, the development of gas turbine technologies with flexible fuel supply systems enables the use of alternative non-fossil fuels that can play key roles in contributing to global efforts in meeting emissions targets. This paper presents the current state of knowledge on the production and potential...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
an intelligent image processing sensor - the algorithm and the hardware implementation
PublicationW artykule przedstawiono algorytm przeznaczony do rozpoznawania obiektów ruchomych w obrazie do celu analizy ruchu pojazdów. Algorytm został zrealizowany w układzie FPGA.Ang.: This paper describes the idea and theimplementation of the robust algorithm dedicated toextraction of moving vehicles from real-time cameraimages for the evaluation of traffic parameters, suchas the number of vehicles, their direction of movementand their...
-
Electrochemical sensor for measurement of volatile organic compounds employing square wave perturbation voltage
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde in air. Sensitivity and limit of quantification of the sensor were determined for different internal electrolyte using the square wave voltammetry (SWV) as a detection technique. The working and counter electrodes were made of platinum. Ionic liquids 1-hexyl, 3-methylimidazolium chloride,1-hexyl, 3-methylimidazolium bis (trifluoromethanesulfonyl)...
-
UV Light-Modulated Fluctuation-Enhanced Gas Sensing by Layers of Graphene Flakes/TiO2 Nanoparticles
PublicationWe present experimental results of fluctuation-enhanced gas sensing by low-cost resistive sensors made of a mixture of graphene flakes and TiO2 nanoparticles. Both components are photocatalytic and activated by UV light. Two UV LEDs of different wavelengths (362 and 394 nm) were applied to modulate the gas sensing of the layers. Resistance noise was recorded at low frequencies, between 8 Hz and 10 kHz. The sensors’ response was...
-
Influence of sensor design and optical properties of tissue on the photoplethysmographic signal
PublicationPhotopletysmography and an associated technique called pulse oximetry are still explored due to the expectations that they give a lot of information about the state of the patient and, also, due to the fact that they are non invasive. Knowledge about the impact of various parameters on the measured signal leads to a faster and a more reliable way of analyzing measurement results and finding the dependencies between the involved...
-
Design and Experimental Validation of a Metamaterial-Based Sensor for Microwave Imaging in Breast, Lung, and Brain Cancer Detection
PublicationThis study proposes an innovative geometry of a microstrip sensor for high-resolution microwave imaging (MWI). The main intended application of the sensor is early detection of breast, lung, and brain cancer. The proposed design consists of a microstrip patch antenna fed by a coplanar waveguide with a metamaterial layer-based lens implemented on the back side, and an artificial magnetic conductor (AMC) realized on as a separate...
-
Novel Desorber for Online Drilling Mud Gas Logging
PublicationThis work presents the construction solution and experimental results of a novel desorber for online drilling mud gas logging. The traditional desorbers use mechanical mixing of the liquid to stimulate transfer of hydrocarbons to the gaseous phase that is further analyzed. The presented approach is based on transfer of hydrocarbons from the liquid to the gas bubbles flowing through it and further gas analysis. The desorber was...
-
Remote Monitoring System for Impedance Spectroscopy using Wireless Sensor Network
PublicationThe architecture of a miniaturized impedanceanalyser with wireless communication module for remoteImpedance Spectroscopy (IS) of anticorrosion coatings ondifficult-to-reach objects (e.g. on the steel construction ofthe bridge) is described in this paper. Some practical aspectsof implementation of a Wireless Sensor Network (WSN) arealso discussed. A low scale, middle range, WSN networkcomposed of a Base Station (BS) with a Personal...
-
Scene Segmentation Basing on Color and Depth Images for Kinect Sensor
PublicationIn this paper we propose a method for segmenting single images from Kinect sensor by considering both color and depth information. The algorithm is based on a series of edge detection procedures designed for particular features of the scene objects. RGB and HSV color planes are separately analyzed in the first step with Canny edge detector, resulting in overall color edges mask. In depth images both clear boundaries and smooth...
-
Multiple sound sources localization in free field using acoustic vector sensor
PublicationMethod and preliminary results of multiple sound sources localization in free field using the acoustic vector sensor were presented in this study. Direction of arrival (DOA) for considered source was determined based on sound intensity method supported by Fourier analysis. Obtained spectrum components for considered signal allowed to determine the DOA value for the particular frequency independently. The accuracy of the developed...
-
Multiple sound sources localization in real time using acoustic vector sensor
PublicationMethod and preliminary results of multiple sound sources localization in real time using the acoustic vector sensor were presented in this study. Direction of arrival (DOA) for considered source was determined based on sound intensity method supported by Fourier analysis. Obtained spectrum components for considered signal allowed to determine the DOA value for the particular frequency independently. The accuracy of the developed...
-
Electrochemically directed biofunctionalization of a lossy-mode resonance optical fiber sensor
PublicationIn this work, we present a direct electrochemical biofunctionalization of an indium-tin-oxide-coated lossy-mode resonance optical fiber sensor. The functionalization using a biotin derivative was performed by cyclic voltammetry in a 10 mM biotin hydrazide solution. All stages of the experiment were simultaneously verified with optical and electrochemical techniques. Performed measurements indicate the presence of a poly-biotin...
-
Possibilities of Increasing the Overall Efficiency of Gas-steam CHP Microplant
PublicationThe paper presents ways to increase the efficiency of a gas-steam micro power plant by modifying the cycle combination. The modification consists in partial release of the fluid downstream of the gas turbine and using it for ORC fluid overheating and evaporation. Advantages of this solution over the simplest gas and steam cycles’ combination are demonstrated.