Filters
total: 6237
filtered: 4797
-
Catalog
- Publications 4797 available results
- Journals 85 available results
- Conferences 1 available results
- People 76 available results
- Projects 11 available results
- Laboratories 1 available results
- Research Teams 2 available results
- Research Equipment 1 available results
- e-Learning Courses 95 available results
- Events 6 available results
- Open Research Data 1162 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: blood flow monitoring, flap vitality, tram, diep, siea, mc, monte carlo, optical window
-
DIFFRACTION PHASE MICROSCOPY FOR OBSERVATION ON RED BLOOD CELLS FLUCTUATION
PublicationNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – RBCs (Red Blood Cells). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations observation...
-
Electrochemical performance of indium-tin-oxide-coated lossy-mode resonance optical fiber sensor
PublicationAnalysis of liquids performed in multiple domain, e.g., optical and electrochemical (EC), has recently focus significant attention. Our previous works have shown that a simple device based on indium-tin-oxide (ITO) coated optical fiber core may be used for optical monitoring of EC processes. At satisfying optical properties and thickness of ITO a lossy-mode resonance (LMR) effect can be obtained and used for monitoring of optical...
-
Does Post-Activation Performance Enhancement Occur during the Bench Press Exercise under Blood Flow Restriction?
Publication -
Does blood flow restriction influence the maximal number of repetitions performed during the bench press? A pilot study
Publication -
The Acute Effects of External Compression With Blood Flow Restriction on Maximal Strength and Strength-Endurance Performance of the Upper Limbs
Publication -
Advanced polarization sensitive analysis in optical coherence tomography
PublicationThe optical coherence tomography (OCT) is an optical imaging method, which is widely applied in variety applications. This technology is used to cross-sectional or surface imaging with high resolution in non-contact and non-destructive way. OCT is very useful in medical applications like ophthalmology, dermatology or dentistry, as well as beyond biomedical fields like stress mapping in polymers or protective coatings defects detection....
-
Linking optical and electronic properties to photoresponse of heterojunctions based on titania nanotubes and chromium, molybdenum, and tungsten oxides
PublicationThe development of photosensitization strategies for titanium dioxide is necessary for the enhancement of its optical and electronic properties towards its application potential in solar photoelectrochemistry. In this work, significant differences in the photosensitizing capability of the 6th group transition metal oxides applied on the surface of titania nanotubes are reported. For the first time, correlations between the experimentally...
-
Topological extraordinary optical transmission
PublicationΤhe incumbent technology for bringing light to the nanoscale, the near-field scanning optical microscope, has notoriously small throughput efficiencies of the order of 10^4-10^5 or less. We report on a broadband, topological, unidirectionally guiding structure, not requiring adiabatic tapering and, in principle, enabling near-perfect (∼100%) optical transmission through an unstructured single arbitrarily subdiffraction slit at...
-
Microsphere structure application for supercapacitor in situ temperature monitoring
PublicationConstant, real-time temperature monitoring of the supercapacitors for efficient energy usage is in high demand and seems to be crucial for further development of those elements. A fiber-optic sensor can be an effective optoelectronic device dedicated for in-situ temperature monitoring of supercapacitors. In this work, the application of the fiber-optic microstrucutre with thin zinc oxide (ZnO) coating fabricated in the atomic layer...
-
Wireless Systems of Threats Monitoring
PublicationThe concept of wireless system of threats monitoring with self-organizing network of multipurpose data transfer nodes are presented. Two practical applications of this system are also presented. The first of these is the Global Wireless Monitoring System for Containers, and the second is the Mobile Monitoring System for Gas Air Pollution Measurements. Presented practical applications of the wireless threats monitoring system is...
-
Nanocrystalline CVD Diamond Coatings on Fused Silica Optical Fibres: Optical Properties Study
Publicationpre-treatment by dip coating in two detonation nanodiamond (DND) seeding media has been studied. The DND suspension in ethyl alcohol and dispersion of DND in dimethyl sulfoxide (DMSO) with polyvinyl alcohol (PVA) were chosen for the seeding purpose. The grain size distribution of nanodiamond particles in both seeding media was kept at the same level (approximately 1050 nm). After the seeding nanocrystalline diamond lms were deposited...
-
Observation on red blood cells fluctuations by diffraction phase microscopy
PublicationNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – Red Blood Cells (RBCs). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations...
-
Wireless Systems of Threats Monitoring
PublicationConcept of wireless system of threats monitoring with self-organizing network of multipurpose data transfer nodes are presented. Two practical applications of this system are also presented. The first of these is the Global Wireless Monitoring System for Containers and the second is the Mobile Monitoring System for Gas Air Pollution Measurements.
-
Wireless systems of threats monitoring
PublicationThe concept of wireless system of threats monitoring with self-organizing network of multipurpose data transfer nodes are presented. Two practical applications of this system are also presented. The first of these is the Global Wireless Monitoring System for Containers, and the second is the Mobile Monitoring System for Gas Air Pollution Measurements.
-
Wireless systems of threats monitoring
PublicationThe concept of wireless system of threats monitoring with self-organizing network of multipurpose data transfer nodes are presented. Two practical applications of this system are also presented. The first of these is the Global Wireless Monitoring System for Containers, and the second is the Mobile Monitoring System for Gas Air Pollution Measurements.
-
Static renewal and continuous-flow calibration of two types of passive samplers for the monitoring of pharmaceuticals in wastewater
Publication -
The Global Burden of Disease Study 2015 and Blood Pressure
Publication -
General practitioners ignore high normal blood pressure
Publication -
Non-adiabatic Effects in Pressure Drop Calculations in Flow Boiling and Flow Condensation in Minichannels
PublicationConsiderations presented in the paper relate both to the case of flow boiling and flow condensation in conventional channels as well as small diameter ones. Authors devoted all the possible attention that the modeling presented is applicable to the whole range of quality variation in both cases of condensation and boiling. The form of two-phase flow multiplier, which is a major factor in modeling presented here, should be capable...
-
Influence of Gaps’ Geometry Change on Leakage Flow in Axial Piston Pumps
PublicationAxial piston pumps are the core elements of most medium and high-pressure hydraulic systems. High volumetric efficiency and high working pressures are the main advantages of this type of pumps. Therefore it is necessary to accurately calculate the leakage flow through the gaps to design efficient high-pressure pump. The main difficulty of such calculations is the fact, that the gaps change their geometry during pumping process....
-
CFD analysis of fluid flow through the labyrinth seal
PublicationSteam and gas turbines are some of the fundamental means of power generation. The energy efficiency of the turbines, however, is not satisfactory. Ever since the start-up of the first turbine in the world, engineers have been striving for their increased efficiency. Multiple solutions to the problem of steam loss in an operating turbine are available. The use of seals is one of them. Empirical methods or numerical calculations...
-
Computer Support of Analysis of Optical Spectra Measurements
PublicationThe verification of measurement errors has a big impact on the assessment of the accuracy of conducted measurements and obtained results. In many cases, computer simulation results are compared with measurement results in order to evaluate measurement errors. The purpose of our research was to check the accuracy of measurements made with a Fabry–Perot interferometer working in the transmission mode. In the measurement setup, a...
-
Protection in elastic optical networks
PublicationIn this article, we analyze gains resulting from the use of EON architectures with special focus on transportation of cloud-ready and content-oriented traffic in the context of network resilience. EONs are a promising approach for future optical transport networks and, apart from improving the network spectral efficiency, bring such new capabilities as squeezed protection, which reduces resource requirements in failure scenarios....
-
Thermal sequences database of the skin flaps in breast reconstruction and burns
PublicationThis paper presents a database of Active Dynamic Thermography (ADT) thermal sequences gathered throughout 6 year study on ADT application in skin flap blood perfusion monitoring and burn wounds diagnosis. For skin flap monitoring the database comprises of data collected during three different breast reconstruction procedures. The patients were monitored pre, intra and post surgically within 90 days period. The sequences were used...
-
A nearly optimal fractional delay filter design with asymmetric window
PublicationW pracy przedstawiono wyniki badań nad zastosowaniem asymetrycznego okna wyodrębnionego zawczasu z filtru optymalnego. Pokazano, że takie podejście przy zastosowaniu dodatkowej korekcji wzmocnienia filtru zależnej od opóźnienia filtru pozwala na projektowanie filtrów prawie optymalnych. W efekcie zaproponowana metoda łączy prostotę metody okien z jakością porównywalną do jakości filtrów optymalnych. Efektywność zaprezentowanej...
-
Jan Buczkowski, widok z okna, view from the window
PublicationKatalog wystawy indywidualnej sztuki, która miała miejsce w Gdańskiej Galerii Güntera Grassa w terminie 2.03 – 14.04.2013. Katalog liczy 32 strony i zawiera tekst krytyczny oraz notę biograficzną autora w języku polskim i angielskim, oraz 17 kolorowych reprodukcji prac. Wydawcą katalogu jest Gdańska Galeria Güntera Grassa. ISBN 978-83-935408-3-9.
-
Effect of asymmetric fluid flow distribution on flow boiling in a microchannel heat sink – An experimental investigation
PublicationFlow boiling in microchannels is emerging as an exclusive cooling solution for miniaturized high-power electronic devices alongside having other high heat flux applications. Size miniaturization at microscale strangely increases heat transfer performance as well as flow boiling instabilities. Many flow boiling instabilities are interrelated and result from imperfect hydrodynamic conditions. One of such problems is flow maldistribution among...
-
A Meta-Analysis of Pulse Arrival Time Based Blood Pressure Estimation
PublicationThe paper presents a preliminary meta-analysis of the sample correlation between pulse arrival time (PAT) and blood pressure (BP). The aim of the study was to verify sample correlation coefficient between PAT and BP using an affine model BP = a · P AT + b for systolic and diastolic blood pressure. The databases included in the search were the IEEE Xplore Digital Library, Springer Link and Google Scholar. Only papers from 2005 to...
-
Container monitoring system
PublicationW pracy przedstawiono koncepcję systemu monitorowania kontenerów przewożonych drogą morską. Scharakteryzowano główne cechy oraz przedstawiono modułowo-warstwowy schemat funkcjonalny. Ponadto opisano założenia funkcjonalno-użytkowe dotyczące Inteligentnego Modułu Kontenerowego (SCM), będącego podstawowym elementem składowym systemu. Przedstawiono również główne zadania projektowe związane z realizacją projektu
-
Optical Coherence Tomography for nanoparticles quantitative characterization
PublicationThe unique features of nanocomposite materials depend on the type and size of nanoparticles, as well as their placement in the composite matrices. Therefore the nanocomposites manufacturing process requires inline control over certain parameters of nanoparticles such as dispersion and concentration. Keeping track of nanoparticles parameters inside a matrix is currently a difficult task due to lack of a fast, reliable and cost effective...
-
In-situ optical diagnostics of boron-doped diamond films growth
PublicationInterferometry is a desirable method for in-situ measurement of thin, dielectric film growth, as it don't modify conditions of film deposition. Here we present interferometrical measurements of thickness of doped diamond films during Chemical Vapor Deposition (CVD) process. For this purpose we used a semiconductor laser with a 405nm wavelength. Additional ex-situ measurement using spectral interferometry and ellipsometry...
-
Dual-wavelength polarimeter application in investigations of the optical activity of a langasite crystal
PublicationA method of high accuracy polarimetry, which includes optical activity measurements systematic errors, was realized with dual-wavelength polarimeter for two wavelengths of 635 and 650 nm. Simultaneous measurements with neighboring wavelengths significantly improved the data processing, by increasing the amount of data to eliminate the systematic errors. For langasite crystal La3Ga5SiO14 we measured temperature dependence of the...
-
EHD Flow Measured by 2D PIV in a Narrow Electrostatic Precipitator with Longitudinally-to-flow Wire Electrode
PublicationIn this paper, results of the electrohydrodynamic (EHD) flow patterns in two narrow ESPs with longitudinally-to-flow wire electrode are presented. The influence of the ESP geometry on the EHD flow generated in the ESP was investigated. The results obtained from 2 dimensional (2D) Particle Image Velocimetry (PIV) showed similarities and differences of the particle flow in the wire-plate and wire-cylinder type ESP.
-
A Comparison of Simplified Two-dimensional Flow Models Exemplified by Water Flow in a Cavern
PublicationThe paper shows the results of a comparison of simplified models describing a two-dimensional water flow in the example of a water flow through a straight channel sector with a cavern. The following models were tested: the two-dimensional potential flow model, the Stokes model and the Navier-Stokes model. In order to solve the first two, the boundary element method was employed, whereas to solve the Navier-Stokes equations, the...
-
Optoelectronic system for monitoring of thin diamond layers growth
PublicationDevelopment of the optoelectronic system for monitoring of diamond/DLC (Diamond-Like-Carbon) thin films growth during mu PA ECR CVD (Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition) process is described. The multi-point Optical Emission Spectroscopy (OES) and Raman spectroscopy were employed as non-invasive optoelectronic tools. Dissociation of H-2 molecules, excitation and ionization of hydrogen...
-
Characterisation of Escherichia coli isolates from the blood of haematological adult patients with bacteraemia: translocation from gut to blood requires the cooperation of multiple virulence factors
PublicationThe aim of the study was to investigate whether there are unique pathotypes of Escherichia coli capable of transmission from the gastrointestinal tract to the vascular bed. The study included E. coli strains isolated from clinical materials collected from 115 patients suffering from haematologic malignancies diagnosed with bacteraemia. The genotyping techniques established that 89 E. coli isolates from the blood had the same genotype...
-
Comparitive study of heat transfer and pressure drop during flow boiling and flow condensation in minichannels
PublicationIn the paper a method developed earlier by authors is applied to calculations of pressure drop and heat transfer coefficient for flow boiling and also flow condensation for some recent data collected from literature for such fluids as R404a, R600a, R290, R32,R134a, R1234yf and other. The modification of interface shear stresses between flow boiling and flow condensation in annular flow structure are considered through incorporation...
-
Analysis of geometrical layout of tram tracks based on the railway methods
Publication -
Integrated acoustical-optical system for inventory of hydrotechnical objects
PublicationThe knowledge of the location, shape and other characteristics of spatial objects in the coastal areas has a significant impact on the functioning of ports, shipyards, and other waterinfrastructure facilities, both offshore and inland. Therefore, measurements of the underwater part of the waterside zone are taken, which means the bottom of the water and other underwater objects (e.g. breakwaters, docks, etc.), and objects above...
-
Blood Pressure in 2016: increased impact factor and change of editors
Publication -
Blood pressure control – Slowly getting there through new strategies?
Publication -
Treatment of high blood pressure in acute stroke – The SCAST Study
Publication -
Cost‐effectiveness of blood pressure measurement and hypertension follow‐up
Publication -
Blood pressure variability: Emerging role in risk assessment and therapeutics
Publication -
Between autonomy and paternalism: Attitudes of nursing personnel towards Jehovah’s Witnesses’ refusal of blood transfusion
PublicationObjectives: The study describes the attitudes of Polish nursing personnel towards Jehovah’s Witnesses’ (JWs’) refusal to receive blood and blood products.Methods: We developed an online survey assessing nurses’ knowledge and attitudes towards JWs’ refusal of blood transfusion in a life-threatening condition. It also examined nurses’ attitudes towards ethical and legal issues associated with JWs’ refusal of bloodtransfusions....
-
Optical rotation in the lithium triborate nonlinear crystal
PublicationA dual-wavelength polarimetric technique at 633 and 661 nm has been used for the characterization of a nonlinear lithium triborate (LiB3O5) nonenantiomorphous biaxial crystal. The mismatch of the crystallographic and optical coordinate systems was taken into account. The optical rotatory power for light propagation along one of the optical axes is ρ = 7.06° mm−1. The gyration tensor component along the bisector between the x and...
-
Flow distribution and heat transfer in minigap and minichannel heat exchangers during flow boiling
PublicationThe topic of boiling heat transfer in miniscale geometries has focused the ever increasing interest of researchers in recent years. However, most of the works are related to mini- and microchannels and much less to minigaps. Meanwhile, minigaps allow for more comprehensive experimental studies, i.e. flow visualisations due to the flat, two-dimensional configuration of the flow. The results of the experimental investigations of...
-
Diagnostics of the tram track shape with the use of the global positioning satellite systems (GPS/Glonass) measurements with a 20 Hz frequency sampling
PublicationSatellite geodetic measurements used in the diagnosis of railway tracks require professional receivers and a very high frequency rate of data processing. It stems from a significant speed (10 km/h) kinematic measurements carried out during the passage of a measuring platform. The survey results (positions) of deformed railroad track have waveforms nature requiring additional processing methods and approximations. Due to the announcement...
-
Remote Monitoring of Environmental Pollutants
PublicationAtmospheric air quality is one of the key factors influencing human health. Air quality evaluation is not an easy task as the atmosphere is a complex system subjected to continuous changes in time. Observed progress in the development of measurement devices and technologies is fundamental for acquisition of more reliable information about condition and quality of atmospheric air. Unfortunately, this process leads to an increase...
-
Ammonia Gas Sensors: Comparison of Solid-State and Optical Methods
PublicationHigh precision and fast measurement of gas concentrations is important for both understanding and monitoring various phenomena, from industrial and environmental to medical and scientific applications. This article deals with the recent progress in ammonia detection using in-situ solid-state and optical methods. Due to the continuous progress in material engineering and optoelectronic technologies, these methods are among the most...