Search results for: LOW VOLTAGE ELECTRICAL INSTALLATIONS - Bridge of Knowledge

Search

Search results for: LOW VOLTAGE ELECTRICAL INSTALLATIONS

Filters

total: 540
filtered: 361

clear all filters


Chosen catalog filters

  • Category

  • Year

  • Options

clear Chosen catalog filters disabled

Search results for: LOW VOLTAGE ELECTRICAL INSTALLATIONS

  • Application of RCD and AFDD in low-voltage electrical installations for protection against fire

    Publication

    The paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.

    Full text available to download

  • Protection against electric shock in electrical installations with low voltage generating sets

    Publication

    - Year 2005

    W referacie przedstawiono zasady ochrony przeciwporażeniowej, zgodne z wymaganiami międzynarodowymi, w sytuacji kiedy instalacja elektryczna jest zasilana z niskonapięciowych zespołów prądotwórczych. Zwrócono uwagę na dobór zabezpieczeń przeciwporażeniowych oraz na wymiarowanie uziemień.

  • Efficient Analysis of Noise Induced in Low-Voltage Installations Placed Inside Buildings with Lightning Protection Systems

    Publication

    - Electronics - Year 2024

    This paper describes an efficient approach to the broadband analysis of lightning protection systems (LPSs) using the method of moments (MoM) implemented in the frequency domain. The adaptive frequency sampling (AFS) algorithm, based on a rational interpolation of the relevant observable (e.g., voltage, current, electric or magnetic field) which describes the properties of the LPS, is employed to reduce the number of samples computed...

    Full text to download in external service

  • Electrical safety in low-voltage DC microgrids with B-type residual current devices

    Publication

    Residual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...

    Full text available to download

  • Blended Learning in Teaching Safety of Electrical Installations

    Publication

    - Year 2014

    Blended learning becomes more commonly used in teaching information technology or other subjects, which involve practice in computer laboratories. In case of subjects with no access to computer rooms blended learning supports lecturing and teaching classes e.g. interactive lessons. The article presents the use of blended learning forms in Gdansk University of Technology in teaching the subject of Safety of Electrical Installations....

    Full text to download in external service

  • Evaluation of fire hazard in electrical installations due to unfavorable ambient thermal conditions

    Publication

    - Fire - Year 2023

    Evaluation of fire hazard caused by electrical installations is a difficult and important topic, and it limits the possibility of loss of life or health of people, as well as the occurrence of significant property damage. In particular, this hazard was caused by power cables and especially photovoltaic (PV) installations. The authors proved that power cables directly exposed to strong solar radiation are likely to exceed maximum...

    Full text available to download

  • Application of residual current devices in electrical installations with frequency converters

    Publication

    - Year 2005

    W instalacjach elektrycznych, w których znajdują się przemienniki częstotliwości mogą pojawić się prądy zwarcia doziemnego o różnej częstotliwości lub stałe. Większość wyłączników różnicowoprądowych nie reaguje na tego typu prądy, co powoduje, że ochrona przeciwporażeniowa jest nieskuteczna. W obwodach z przemiennikami częstotliwości mogą pojawiać się przejściowe i ustalone prądy upływowe o znacznych wartościach. Prądy te znacząco...

  • Modern power-electronics installations in the Polish electrical power network

    Publication

    The paper discusses the most important areas of application of power electronics arrangements in the Polish electrical power system; especially in the distribution system. The examples presented demonstrate both the need for and the purpose of further research and its applications in these fields, as well as indicating the direction of future research, with special consideration given to the research required in Poland. The proposed...

    Full text to download in external service

  • Evaluation of Fire Hazard in Electrical Installations Due to Unfavorable Ambient Thermal Conditions

    Publication
    • S. Szultka
    • S. Czapp
    • A. Tomaszewski
    • H. Ullah

    - Fire - Year 2023

    Full text to download in external service

  • Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables

    Publication
    • M. A. Saleh
    • S. S. Refaat
    • M. Olesz
    • H. Abu-Rub

    - Year 2021

    This work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC...

    Full text to download in external service

  • Critical evaluation of resonaut gc voltage link inventures for electrical drives.

    Publication

    - Year 2004

    Przedstawiono wyniki modelowania i symulacji falowników z centralnym obwodem rezonansowym dla zastosowań w napędzie elektrycznym. Porównano struktury ukladów z rezonansowym równoległym obwodem pośredniczącym o ograniczonej wartości szczytowej i uasi-rezonansowych. Dla potrzeb projektowania tych układów, wobec przeciwstawnych funkcji celu dokonano ich wielokrytycznej oceny.

  • Design of hight voltage busbar: trade off between electrical field and stray inductance

    Publication

    - Year 2003

    Artykuł dotyczy optymalizacji konstrukcji i technologii szyny doprowadzenia zasilania do pojedynczej gałęzi falownika średniego napięcia. Dla szeregowego układu złożonego z trzech modułów elektroizolowanych (6 par tranzystorów i diod) rozważono warianty geometrii szyny zasilania przy uwzględnieniu wypadkowej indukcyjności obwodu komutacyjnego. Wyznaczono główne składniki indukcyjności rozproszenia oraz wykazano jej wpływ na przepięcia...

  • LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations

    Publication

    - Year 2017

    Evaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...

    Full text to download in external service

  • Behavior of residual current devices at earth fault currents with DC component

    Publication

    - SENSORS - Year 2022

    Low-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...

    Full text available to download

  • Time-current tripping characteristics of RCDs for sinusoidal testing current

    Publication

    - Year 2021

    Low-voltage electrical installations are verified initially – before being put into operation, as well as periodically – during their utilization. According to the IEC standards, the scope of the verification includes measurements of both the tripping current and the disconnection time of residual current devices (RCDs). Experiences in RCDs testing show that disconnection times of two or more similar RCDs can be quite different....

    Full text to download in external service

  • Tripping of F-type RCDs for High-Frequency Residual Currents

    Publication

    - Year 2021

    Residual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs...

  • Tripping of F-type RCDs for high-frequency residual currents

    Publication

    - Year 2021

    Residual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs are...

    Full text to download in external service

  • Voltage variations and their reduction in a rural low-voltage network with PV sources of energy

    Publication

    - Electronics - Year 2021

    Renewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...

    Full text available to download

  • Badanie wybranych właściwości wyłączników różnicowoprądowych typu F

    W instalacjach elektrycznych niskiego napięcia instaluje się coraz więcej przekształtników energoelektronicznych (systemy fotowoltaiczne, instalacje ładowania pojazdów elektrycznych, układy napędowe o regulowanej prędkości obrotowej silnika), a mają one wpływ na dobór typu wyzwalania wyłączników różnicowoprądowych (AC, A, F lub B). W obwodach, w których pojawia się prąd różnicowy zawierający składowe o częstotliwości innej niż...

    Full text available to download

  • Quality assessment of low voltage surge arresters

    Users expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...

    Full text available to download

  • An ANN-Based Method for On-Load Tap Changer Control in LV Networks with a Large Share of Photovoltaics—Comparative Analysis

    Publication

    - ENERGIES - Year 2024

    The paper proposes a new local method of controlling the on-load tap changer (OLTC) of a transformer to mitigate negative voltage phenomena in low-voltage (LV) networks with a high penetration of photovoltaic (PV) installations. The essence of the method is the use of the load compensation (LC) function with settings determined via artificial neural network (ANN) algorithms. The proposed method was compared with other selected...

    Full text to download in external service

  • Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits

    Publication

    Verification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...

    Full text available to download

  • Dielectric Barrier Discharge Systems with HV Generators and Discharge Chambers for Surface Treatment and Decontamination of Organic Products

    Publication

    - ENERGIES - Year 2020

    The article presents applications of systems with power electronic converters, high voltage transformers, and discharge chambers used for nonthermal, dielectric barrier discharge plasma treatment of a plastic surface and decontamination of organic loose products. In these installations, the inductance of the high voltage transformers and the capacitances of the electrode sets form resonant circuits that are excited by inverters....

    Full text available to download

  • Tripping of F-type RCDs for sinusoidal residual current with superimposed smooth DC component

    Publication

    - Year 2022

    Recent trends in green energy development make that photovoltaics and electric vehicles are applied on an increasing scale. In both photovoltaic and electric vehicle charging installations, a significant value of DC component of the earth fault current may appear, which is a challenge, in particular, for commonly used residual current devices (RCDs). This paper presents results of the laboratory test on the operation of F-type...

    Full text to download in external service

  • The measurement of input power of power supply in network disturbed by low frequency distortions

    In the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed

    Full text available to download

  • The Influence of a Photovoltaic Micro-Installation on the Low-Frequency Parameters of Electricity at PCC and Its Impact on the Thermal Characteristics of Selected Devices

    Publication

    - ENERGIES - Year 2021

    This manuscript illustrates the measurement results of parameters describing the quality of energy at the PCC (point of common coupling) of a photovoltaic micro-installation that can significantly affect devices in the same power grid. The analyses reflecting heating of selected devices used in domestic installations, which were performed in an isolated laboratory environment, are also indicated. The conducted study aimed at checking...

    Full text available to download

  • Low speed permanent magnet synchronous generator for vertical axis wind turbine

    Publication

    The paper presents design process and tests of a prototype low speed permanent magnet synchronous generator (PMSG) dedicated for the innovative vertical-axis wind turbine. The rated data of the designed generator are following: power - 15 kVA, voltage - 400 V (Y), rotation speed - 93.75 rpm. The design assumptions, chosen results of the design process and experimental tests of the prototype PMSG are presented. The considered PMSG...

    Full text to download in external service

  • Assessment of the factors influencing on the formation of energy-oriented modes of electric power consumption by water-drainage installations of the mines

    Publication
    • O. Sinchuk
    • I. Sinchuk
    • T. Beridze
    • Y. Filipp
    • K. Budnikov
    • O. Dozorenko
    • R. Strzelecki

    - Mining of Mineral Deposits - Year 2021

    Purpose. Performing the analysis to determine energy-efficient modes and assess the characteristics of the main indicators of electric power consumption by mine water-drainage installations based on the developed research mathematical model. Methods. To achieve the purpose set, a methodology is used to develop the multiple multifactor correlation-regression modeling with respect to the modes of electric power consumption by electrical...

    Full text available to download

  • Power electronic transformer based on cascaded H-bridge converter

    In this paper the control strategy of power electronic transformer (PET) is proposed. The analyzed structure of PET uses two seven-level cascaded H-bridge (CHB) rectifiers. The electrical power of PET is transferred between DC-links of CHB converters using dual-active-bridges (DABs) and low voltage high frequency transformers. The roposed solution allows for controlling the active and reactive power with a low level of harmonic...

    Full text available to download

  • Tripping limitations of residual current devices in photovoltaic installations

    Publication

    - Year 2017

    In electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...

    Full text to download in external service

  • Low-frequency tripping characteristics of residual current devices

    Fast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...

    Full text to download in external service

  • AC Motor Voltage and Audible Noise Dataset

    Publication

    - Year 2022

    The dataset titled AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters contains the voltage and sound measurement results recorded in a marine frequency controlled AC drive system. The dataset is part of research focussing on the impact of the ship’s electrical drive systems with frequency converters on vibrations and the level of audible noise on ships. The dataset allows the...

    Full text available to download

  • Electro-optical transducer based on indium-tin-oxide-coated optical fiber for analysis of ionized media

    Publication

    - MEASUREMENT - Year 2023

    The paper introduces a concept of an optical fiber based electro-optical transducer for monitoring of ionized media, such as low-temperature plasma. It utilizes optical fiber with a section of a core coated with tailored indium tin oxide (ITO) thin film and thus combines the optical phenomena of lossy-mode resonance (LMR) with the electrostatic probe. ITO is an optically transparent and electrically conductive material and if its...

    Full text to download in external service

  • The Possibility of Phase Change Materials (PCM) Usage to Increase Efficiency of the Photovoltaic Modules

    Solar energy is widely available, free and inexhaustible. Furthermore this source of energy is the most friendly to the environment. For direct conversion of solar energy into useful forms like of electricity and thermal energy, respectively photovoltaic cells and solar collectors are being used. Forecast indicate that the first one solution will soon have a significant part in meeting the global energy demand. Therefore it is...

    Full text to download in external service

  • Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids

    This paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.

    Full text available to download

  • Quality assessment of ZnO-based varistors by 1/f noise

    Noise has been used as a diagnostic tool of surge arrester varistor structures comprising of ZnO grains of various type and size. The physical and electrical properties of the measured samples have been described. In the experimental study, the applied measurement system and the results of noise measurements for the selected structures of varistors designed for the continuous working voltage 280 V, 440 V and 660 V have been presented....

    Full text available to download

  • Assessment of Fuel Cells’ State of Health by Low-Frequency Noise Measurements

    We proposed applying low-frequency (flicker) noise in proton-exchange membrane fuel cells under selected loads to assess their state of health. The measurement set-up comprised a precise data acquisition board and was able to record the DC voltage and its random component at the output. The set-up estimated the voltage noise power spectral density at frequencies up to a few hundred mHz. We observed the evolution of the electrical...

    Full text available to download

  • Exercise bike powered electric generator for fitness club appliances

    Publication

    - Year 2007

    A generator powered by a stationary bicycle for the purposes of generating electricity for fitness club appliances is considered. A generator is connected to a stationary bicycle in such a way as the circular rotation of the front wheel rotates the coils of wires inside the generator between the poles of the magnets inside the generator. The resulting Direct Current is channeled to the attached battery bank and converted into different...

    Full text available to download

  • PV installations and the safety of residential buildings

    The dynamic development of the photovoltaic industry entails threats that have a direct impact on the safety of residential buildings. Appropriate design of a PV installation can be a challenge due to the multifaceted nature of this issue. The designer should take into account issues related to the selection of electrical parameters of the installation, adapting lightning and surge protection in accordance...

    Full text available to download

  • Metody doboru miejsc zainstalowania zasobników energii w sieciach elektroenergetycznych niskiego napięcia

    W związku z rosnącą liczbą źródeł odnawialnych przyłączanych do sieci niskiego napięcia (nn) jakość energii elektrycznej w tej sieci ulega pogorszeniu. Jedną z metod jej poprawiania jest instalowanie zasobników energii, tj. baterii akumulatorów, superkondensatorów czy kół zamachowych. Zasobniki energii są w stanie złagodzić dobową zmienność obciążenia, skompensować moc bierną i wyższe harmoniczne oraz zmniejszyć asymetrię obciążenia...

    Full text to download in external service

  • Propagation Characteristics of Partial Discharges in an Oil-Filled Power Transformer

    Publication
    • S. M. Kameli
    • S. S. Refaat
    • A. Ghrayeb
    • H. Abu-Rub
    • J. Guziński

    - Year 2023

    Power transformers are among the most important assets in the power transmission and distribution grid. However, they suffer from degradation and possible faults causing major electrical and financial losses. Partial discharges (PDs) are used to identify the insulation health status and their degradation level. PDs are incipient, low-magnitude faults caused by localized dielectric breakdown. Those activities emit signals in many...

    Full text to download in external service

  • Synthesis and Testing of BCZY/LNZ Mixed Proton–electron Conducting Composites for Fuel Cell Applications

    A composite of BaCe0.6Zr0.2Y0.2O3–δ and Li2O:NiO:ZnO was investigated for fuel cell applications. The composite was successfully synthesized and its phase stability was confirmed at temperatures up to 900 °C. The influence of sintering and pressing aids on density was also investigated. Electrical properties were measured. DC electrical conductivity was about 8•10-4 S/m at 845 K. Open circuit voltage measurements in wet hydrogen...

    Full text available to download

  • Static Series and Shunt-series PE Voltage-quality Controllers

    Publication

    - Year 2007

    As presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...

    Full text to download in external service

  • Inception and Propagation of Electrical Trees in the Presence of Space Charge in HVAC Extruded Cables

    Publication
    • M. A. Saleh
    • S. S. Refaat
    • M. Olesz
    • H. Abu-Rub

    - IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION - Year 2021

    This paper presents the space charge impact on the inception and propagation of electrical trees in cross-linked polyethylene (XLPE) insulation via simulations and experimentation. A 3D finite element analysis (FEA)-based modeling is proposed to simulate electrical trees via a needle embedded on the XLPE insulation. The proposed FEA model demonstrates the influence of the space charge magnitude and polarity on the initiation of...

    Full text to download in external service

  • Control system for contactless electrical energy transfer with varying air gap

    Publication

    - Year 2014

    Inductive power transfer (IPT) is a system by which electrical energy may be transmitted without electrical connection through a large air gap between coils. Systems usually considered in the literature are the ones with a constant air gap. The paper describes the analysis of IPT, which allows for supplying an electrical load in the conditions of slow, in relation to the dynamics of power supply, changes in the dimensions of the...

  • Testing sensitivity of A-type residual current devices to earth fault currents with harmonics

    Publication

    - SENSORS - Year 2020

    In many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...

    Full text available to download

  • The effect of current delay angle on tripping of residual current devices

    Publication

    - Year 2017

    Power electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....

    Full text to download in external service

  • Voltage Conditions in Low Voltage Grid with Connected Mictogeneration

    Publication

    - Acta Energetica - Year 2017

    The introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...

    Full text available to download

  • Electromagnetic-based derivation of fractional-order circuit theory

    In this paper, foundations of the fractional-order circuit theory are revisited. Although many papers have been devoted to fractional-order modelling of electrical circuits, there are relatively few foundations for such an approach. Therefore, we derive fractional-order lumped-element equations for capacitors, inductors and resistors, as well as Kirchhoff’s voltage and current laws using quasi-static approximations of fractional-order...

    Full text available to download

  • Performance Evaluation of a 650V E-HEMT GaN Power Switch

    Publication

    - Year 2015

    GaN power switches have better characteristics compared to the state-of-the-art Si power transistors. These devices offer high operating temperature and current densities, fast switching and low on-resistance. However, currently only a few producers offer technology of high voltage GaN transistors. Immaturity of this technology is the reason why experimental evaluation of GaN parameters must be performed to properly exploit their...