Search results for: BLOOD PRESSURE, PHOTOPLETHYSMOGRAPHY, WEARABLE SENSORS
-
Numerical modelling and experimental verification of compressible squeeze film pressure
PublicationThe validity of using the Reynolds equation for compressible squeeze film pressure was tested with computational fluid dynamics (CFD). A squeeze film air bearing was instrumented with pressure sensors and non-contacting displacement probes to provide transient measurements of film thickness and pressure. The film thickness measurements also provided input parameters to the numerical prediction. However, numerical results showed...
-
Numerical investigation of multiphase blood flow coupled with lumped parameter model of outflow
PublicationPurpose The purpose of this paper is the application of the computational fluid dynamics model simulating the blood flow within the aorta of an eight-year-old patient with Coarctation of Aorta. Design/methodology/approach The numerical model, based on commercial code ANSYS Fluent, was built using the multifluid Euler–Euler approach with the interaction between the phases described by the kinetic theory of granular flow (KTGF). Findings A...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublicationIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
Prototype of an opto-capacitive probe for non-invasive sensing cerebrospinal fluid circulation
PublicationIn brain studies, the function of the cerebrospinal fluid (CSF) awakes growing interest, particularly related to studies of the glymphatic system in the brain, which is connected with the complex system of lymphatic vessels responsible for cleaning the tissues. The CSF is a clear, colourless liquid including water (H2O) approximately with a concentration of 99 %. In addition, it contains electrolytes, amino acids, glucose, and...
-
New method to monitor changes in the subarachnoid width and pial artery pulsation for physiological and clinical research
PublicationThere are several medical conditions associated with brain oedema such as traumatic brain injury, intoxication or tumors. Brain edema and related brain parenchyma expansion may lead to compression and subsequent injury of several brain structures. So far, the only method enabling detection and monitoring of the progress a cerebral oedema in a patient, has been monitoring of intracranial pressure (ICP) with a pressure probe inserted...
-
A Novel IoT-Perceptive Human Activity Recognition (HAR) Approach Using Multi-Head Convolutional Attention
PublicationTogether with fast advancement of the Internet of Things (IoT), smart healthcare applications and systems are equipped with increasingly more wearable sensors and mobile devices. These sensors are used not only to collect data, but also, and more importantly, to assist in daily activity tracking and analyzing of their users. Various human activity recognition (HAR) approaches are used to enhance such tracking. Most of the existing...
-
Portable exhaled breath analyzer employing fluctuation-enhanced gas sensing method in resistive gas sensors
PublicationThis paper presents a portable exhaled breath analyser, developed to detect selected diseases. The set-up employs resistive gas sensors: commercial MEMS sensors and prototype gas sensors made of WO3 gas sensing layers doped with various metal ingredients. The set-up can modulate the gas sensors by applying UV light to induce physical changes of the gas sensing layers. The sensors are placed in a tiny gas chamber of a volume...
-
Pial artery and subarachnoid width response to apnoea in normal humans
PublicationBackground: Little is known about intracranial pressure (ICP)-cerebral haemodynamic interplay during repetitive apnoea. A recently developed method based on near-infrared transillumination/backscattering sounding (NIR-T/BSS) noninvasively measures changes in pial artery pulsation (cc-TQ) as well as subarachnoid width (sas-TQ) in humans. Method: We tested the complex response of the pial artery and subarachnoid width to apnoea...
-
MONTE CARLO MODELING OF OPTICAL SENSOR FOR POST-OPERATIVE FREE FLAP MONITORING
PublicationAfter a preliminary study of the currently employed methods in vitality monitoring of the tissue flaps (TRAM, DIEP, SIEA), a usefulness of optical techniques is discussed. It seems that one of the most promising in monitoring tissue flaps blood flow is a near infrared spectrometry (NIRS). However, a special design of a measurement sensor has to be developed. First, basing on the literature study an optical “window” is characterized....
-
Employees With Autism Spectrum Disorders in the Digitized Work Environment: Perspectives for the Future
PublicationThe aim of this article is to examine the opportunities for employees with autism spectrum disorders (ASDs), arising from digital technology (DT) development. The author discusses assistive technology (AT) as a mean of creating a better work environment, making the digitized workplace more friendly for people with ASD. A possible solution of communication problems is replacing the interpersonal communication between employees with...
-
Handwritten signature verification system employing wireless biometric pen
PublicationThe handwritten signature verification system being a part of the developed multimodal biometric banking stand is presented. The hardware component of the solution is described with a focus on the signature acquisition and on verification procedures. The signature is acquired employing an accelerometer and a gyroscope built-in the biometric pen plus pressure sensors for the assessment of the proper pen grip and then the signature...
-
Exploring the technological dimension of Autonomous sensory meridian response-induced physiological responses
PublicationBackground In recent years, the scientific community has been captivated by the intriguing Autonomous sensory meridian response (ASMR), a unique phenomenon characterized by tingling sensations originating from the scalp and propagating down the spine. While anecdotal evidence suggests the therapeutic potential of ASMR, the field has witnessed a surge of scientific interest, particularly through the use of neuroimaging techniques...
-
Emotion Monitoring – Verification of Physiological Characteristics Measurement Procedures
PublicationThis paper concerns measurement procedures on an emotion monitoring stand designed for tracking human emotions in the Human-Computer Interaction with physiological characteristics. The paper addresses the key problem of physiological measurements being disturbed by a motion typical for human-computer interaction such as keyboard typing or mouse movements. An original experiment...
-
Data from environmental sensors installed in two locations
Open Research DataThe dataset contains data gathered from environmental sensors installed in two locations:
-
Influence of preprocessing techniques on pulse pressure velocity determination
PublicationPulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...
-
Effects of consecutive apneas on pial artery pulsation and subarachnoid width in healthy subjects
PublicationHypercapnia is known to dilate the pial artery, disrupt cerebral autoregulation and increase pial artery pulsation. The cerebral blood flow velocity (CBFV) response to hypercapnia is biphasic. Below the threshold for the increase of blood pressure (BP) with carbon dioxide partial pressure (pCO2), the CBFV measurement reflects vascular reactivity to pCO2 alone at a constant BP. Above this threshold, the CBFV measurement provides...
-
Estimation of Oxidative Stress Markers in Chronic Kidney Disease
Publication -
Long term measurements of PM1, PM2.5, PM10 and NO2 in open-air at Gdansk (Poland) area using low-cost sensors together with the reference results
Open Research DataThe measurements results of open-air measurements made using the following low-cost sensors: particulate matter (PM) sensor SPS30 from Sensirion, NO2 electrochemical sensor SGX-7NO2 from SGX Sensortech, NO2 electrochemical sensor 7E4-NO2 from SemaTech, compact MOS air quality sensor MiCS 2714 from SGX Sensortech, BME280 (Bosch) environmental sensor...
-
The Discrete-Continuous, Global Optimisation of an Axial Flow Blood Pump
PublicationThis paper presents the results of the discrete-continuous optimisation of an axial flow blood pump. Differential evolution (DE) is used as a global optimisation method in order to localise the optimal solution in a relatively short time. The whole optimisation process is fully automated. This also applies to geometry modelling. Numerical simulations of the flow inside the pump are performed by means of the Reynolds-Average Navier-Stokes...
-
Discrete-continuous optimisation of an axial flow blood pump
PublicationThis paper presents results of discrete-continuous optimisation of an axial flow blood pump. Evolution Strategies (ES) are used as a global optimisation method in order to localise the optimal solution in relatively short time. The whole optimisation process is fully automated. This also applies to geometry modelling. Numerical simulations of the flow inside the pump is performed by means of the Reynolds-Average Navier-Stokes...
-
Wavelet transform analysis to assess oscillations in pial artery pulsation at the human cardiac frequency
PublicationPial artery adjustments to changes in blood pressure (BP)may last only seconds in humans. Using a novelmethod called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) in humans, we aimed to assess the relationship between spontaneous oscillations in BP and cc-TQ at frequencies between 0.5 Hz and 5 Hz. We hypothesized that analysis of...
-
Fatal N-Ethylhexedrone Intoxication
PublicationN-Ethylhexedrone [2-(ethyloamino)-1-phenylhexan-1-one; α-ethylaminohexanophenone; NEH] is one of the most recent synthetic cathinones that appeared on the illegal market in late 2015. The majority of information concerning the model of consumption of NEH and its impact on the body originates only from self-reports from grey literature websites and drug forums. There are only limited data associated with the concentrations of NEH...
-
Emotion Monitor - Concept, Construction and Lessons Learned
PublicationThis paper concerns the design and physical construction of an emotion monitor stand for tracking human emotions in Human-Computer Interaction using multi-modal approach. The concept of the stand using cameras, behavioral analysis tools and a set of physiological sensors such as galvanic skin response, blood-volume pulse, temperature, breath and electromyography is presented and followed...
-
The applicability of low-cost PM10 sensors for atmospheric air quality monitoring
PublicationDescribed in this work are the results of field tests carried out in the Tricity Agglomeration between 01 April 2018 and 30 June 2018 in order to evaluate the usefulness of low-cost PM10 sensors in atmospheric air quality monitoring. The results were juxtaposed with the results obtained using reference methods. The results were validated based on the measurement uncertainty as described in...
-
AeroSense Measurements: Wind Tunnel Ecole Centrale Lyon
Open Research DataData from wind tunnel tests of Aerosesne measurement system installed on NACA 63418 aerfoil in the anechoic wind tunnel at the Ecole Centrale Lyon.
-
System Weryfikacji Autentyczności Podpisu Odręcznego
PublicationW referacie przedstawiono system statycznej i dynamicznej weryfikacji autentyczności podpisu odręcznego, składanego piórem biometrycznym, wyposażonym w 2 akcelerometry, 2 żyroskopy i 3 czujniki ścisku, na rezystancyjnej powierzchni dotykowej, łączącym się bezprzewodowo z urządzeniami komputerowymi. We wstępie przedstawiono architekturę sieciową wielomodalnego systemu biometrii. Przedstawiono warstwę sprzętową systemu weryfikacji...
-
Algoritmically improved microwave radar monitors breathing more acurrate than sensorized belt
PublicationThis paper describes a novel way to measure, process, analyze, and compare respiratory signals acquired by two types of devices: a wearable sensorized belt and a microwave radar-based sensor. Both devices provide breathing rate readouts. First, the background research is presented. Then, the underlying principles and working parameters of the microwave radar-based sensor, a contactless device for monitoring breathing, are described....
-
Comparison between measured and calculated underwater pressure of merchant ship
PublicationFrom 2012 The Polish Naval Academy take part in an international research project SIRAMIS, carried out in the framework of the European Defence Agency. The objective of this project is to improve the understanding of ship signature interaction with multi influence sensors in relevant and realistic scenario's. This paper describes selected results of the comparison results of sea trials and model calculations of the hydrodynamic...
-
Assessment of cardiovascular risk in assisted living
PublicationWady i choroby układu krążenia są jedną z podstawowych przyczyn problemów zdrowotnych oraz przyczyn śmierci. Wczesne ich wykrycie jest szczególnie cenne jako, że może zapobiec przez poważnymi incydentami (np. zawał, udar, itp.). W artykule przedstawiono nasobny system pomiarowy integrujący wiele pomiarów przydatnych do oceny problemów kardiologicznych.Disorders of the heart and blood vessels are the leading cause of health problems...
-
CARDIOVASCULAR RISK FACTORS AMONG POLISH EMPLOYEES OF UNIFORMED SERVICES
PublicationObjectives: Employees of uniformed services (EoUS) were screened for cardiovascular risk factors. Material and Methods: A total of 1138 EoUS (age M±SD 49.9±6.0 years) and 263 controls (age M±SD 54.4±9.7 years) under the care of the cardiology clinic in Gdańsk, Poland,were included in the study. Medical history and blood samples were collected, and a physical examination was performed. Ten-year cardiovascular risk of death was...
-
Numerical Model of the Aortic Valve Implanted Within Real Human Aorta
PublicationCardiovascular system diseases are the main cause of deaths in developed and developing countries. The main reasons are myocardial infarction, heart failure, stroke and valvular diseases. These are caused mainly by arteriosclerosis. The valvular diseases involve a significant burden for the health care system and their frequency is rising with the patient age. This work describes the tools and numerical models appropriate for modeling...
-
Performance Analysis of Developed Multimodal Biometric Identity Verification System
PublicationThe bank client identity verification system developed in the course of the IDENT project is presented. The total number of five biometric modalities including: dynamic handwritten signature proofing, voice recognition, face image verification, face contour extraction and hand blood vessels distribution comparison have been developed and studied. The experimental data were acquired employing multiple biometric sensors installed...
-
The Concept of Accuracy Analysis of the Vertical Displacements Gained from the Hydrostatic Levelling Systems’ Measurements
PublicationAbstract: Nowadays, hydrostatic levelling is a widely used method for the vertical displacements’ determinations of objects such as bridges, viaducts, wharfs, tunnels, high buildings, historical buildings, special engineering objects (e.g., synchrotron), sports and entertainment halls. The measurements’ sensors implemented in the hydrostatic levelling systems (HLSs) consist of the reference sensor (RS) and sensors located on the...
-
Highly Reliable Passive RFID-Based Inductor–Capacitor Sensory System Strengthened by Solvatochromism for Fast and Wide-Range Lactate Detection
PublicationA passive radio frequency-identification-based inductor-capacitor (LC) lactate sensory system with a specific dye-containing interdigitated capacitor (IDC) in which the sensing signal is amplified by the solvatochromic effect is proposed. When a lactate solution contacts the IDC of the LC lactate sensor, the capacitance of the IDC changes, changing the resonance frequency of the sensor. This changes the oscillation frequency of...
-
Optical Sensor Based Gestures Inference Using Recurrent Neural Network in Mobile Conditions
PublicationIn this paper the implementation of recurrent neural network models for hand gesture recognition on edge devices was performed. The models were trained with 27 hand gestures recorded with the use of a linear optical sensor consisting of 8 photodiodes and 4 LEDs. Different models, trained off-line, were tested in terms of different network topologies (different number of neurons and layers) and different effective sampling frequency...
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 500 mm stroke subjected only to a mass load of 1640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 750 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1100 g
Open Research Data -
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1650 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 930 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 930 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1650 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 450 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 500 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 930 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....