Filters
total: 690
Search results for: LIGHT SENSOR
-
Determination of the Vehicles Speed Using Acoustic Vector Sensor
PublicationThe method for determining the speed of vehicles using acoustic vector sensor and sound intensity measurement technique was presented in the paper. First, the theoretical basis of the proposed method was explained. Next, the details of the developed algorithm of sound intensity processing both in time domain and in frequency domain were described. Optimization process of the method was also presented. Finally, the proposed measurement...
-
Magnetic field gradient as the most useful signal for detection of flaws using MFL technique
PublicationThe magnetic flux leakage (MFL) technique is extensively used for detection of flaws as well as for evaluation of their dimensions in ferromagnetic materials. However, proper analysis of the MFL signal is hindered by the MFL sensor velocity causing distortions of this signal. Traditionally measured components of the MFL signal are particularly sensitive to the scanning velocity. In this paper, an another signal – the gradient of...
-
Electronic Noses and Electronic Tongues
PublicationChapter 7 reports the achievements on the field of artificial senses, such as electronic nose and electronic tongue. It examines multivariate data processing methods and demonstrates a promising potential for rapid routine analysis. Main attention is focused on detailed description of sensor used, construction and principle of operation of these systems. A brief review about the progress in the field of artificial senses and future trends...
-
Nitrogen dioxide sensing properties of PEDOT polymer films
PublicationThis work presents a simple and fully electrochemical route for the polymerization of poly(3,4-ethylenedioxytiophene) (PEDOT) films for fabricating a NO2 gas sensor prepared by electropolymerization of 3,4-Ethylenedioxythiophene (EDOT) monomer in lithium perchlorate/acetonitrile solution. The main aim of this study is to determine the sensing properties of conductive polymer at elevated temperatures. The effects of the humidity,...
-
Remote Monitoring System for Impedance Spectroscopy using Wireless Sensor Network
PublicationThe architecture of a miniaturized impedanceanalyser with wireless communication module for remoteImpedance Spectroscopy (IS) of anticorrosion coatings ondifficult-to-reach objects (e.g. on the steel construction ofthe bridge) is described in this paper. Some practical aspectsof implementation of a Wireless Sensor Network (WSN) arealso discussed. A low scale, middle range, WSN networkcomposed of a Base Station (BS) with a Personal...
-
Fluctuation-Enhanced Sensing with Organically Functionalized Gold Nanoparticle Gas Sensors Targeting Biomedical Applications
PublicationDetection of volatile organic compounds is a useful approach to non-invasive diagnosis of diseases through breath analysis. Our experimental study presents a newly developed prototype gas sensor, based on organically-functionalized gold nanoparticles, and results on formaldehyde detection using fluctuation-enhanced gas sensing. Formaldehyde was easily detected via intense fluctuations of the gas sensor’s resistance, while the cross-influence...
-
Multichannel Human Body Communication
PublicationHuman Body Communication is an attractive alternative for traditional wireless communication (Bluetooth, ZigBee) in case of Body Sensor Networks. Low power, high data rates and data security makes it ideal solution for medical applications. In this paper, signal attenuation for different frequencies, using FR4 electrodes, has been investigated. Performance of single and multichannel transmission with frequency modulation of analog...
-
Big Data from Sensor Network via Internet of Things to Edge Deep Learning for Smart City
PublicationData from a physical world is sampled by sensor networks, and then streams of Big Data are sent to cloud hosts to support decision making by deep learning software. In a smart city, some tasks may be assigned to smart devices of the Internet of Things for performing edge computing. Besides, a part of workload of calculations can be transferred to the cloud hosts. This paper proposes benchmarks for division tasks between an edge...
-
MONTE CARLO MODELING OF OPTICAL SENSOR FOR POST-OPERATIVE FREE FLAP MONITORING
PublicationAfter a preliminary study of the currently employed methods in vitality monitoring of the tissue flaps (TRAM, DIEP, SIEA), a usefulness of optical techniques is discussed. It seems that one of the most promising in monitoring tissue flaps blood flow is a near infrared spectrometry (NIRS). However, a special design of a measurement sensor has to be developed. First, basing on the literature study an optical “window” is characterized....
-
Scalable Measurement System for Multiple Impedance Gas Sensors
PublicationAuthor proposes scalable architecture of the measurement system for gas sensor with impedance dependance of the gas concentration. The main part of the system is a single-board impedance analyser. The number of analysers working in parallel can be configured according to specific application. The system is controlled by a single computer which organises the measurement cycle and store the acquired measurement data. The system is...
-
The silver layers in fiber-optic sensors
PublicationIn this paper a method of application of the silver layers on the surface of an optical fiber was proposed. The optical properties and surface quality of the silver layer was examined by optical microscopy. The reflection and transmission of the sample were investigated. To evaluate the silver mirror it was placed in a fiber optic Fabry-Perot interferometer and the quality of the spectra was analyzed. The commercial mirror was...
-
Application of fiber optic sensors using Machine Learning algorithms for temperature measurement of lithium-ion batteries
PublicationOptical fiber sensorsusing low-coherence interferometry require processing ofthe output spectrum or interferogramto quickly and accurately determine the instantaneous value of the measured quantity, such as temperature.Methods based on machine learning are a good candidate for this application. The application of four such methods in an optical fiber temperature sensoris demonstrated.Using aZnO-coated...
-
Hardware-Software Implementation of a Sensor Network for CityTraffic Monitoring Using the FPGA- and ASIC-Based Sensor Nodes
PublicationArtykuł opisuje prototypową sieć sensorową do monitorowania ruchu pojazdów w mieście. Węzły sieci sensorowej, wyposażone w kamerę o niskiej rozdzielczości, obserwują ulice i wykrywają poruszające się obiekty. Detekcja obiektów jest realizowana w oparciu o własny algorytm segmentacji obrazów, wykorzystujący podwójne odejmowanie tła, wykrywanie krawędzi i cieni, działający na dedykowanym systemie mikroelektronicznym typu ''System...
-
Micoroalgae bloom detected in Southern Baltic Sea on 25.07.2014
Open Research DataThe GeoTIFF image presents detected microalgae bloom observed in the Baltic Sea on 25.07.2014. The image has been obtained from the raw AVHRR sensor bands 1 (0.58-0.68 μm) and 2 (0.725-1.0 μm). The resulting single-band raster has been masked to remove all pixels outside of the Baltic Sea region. Pixel values between -0.2 and -0.23 depict progressively...
-
Advanced Sensor for Non-Invasive Breast Cancer and Brain Cancer Diagnosis Using Antenna Array with Metamaterial-Based AMC
PublicationMicrowave imaging techniques can identify abnormal cells in early development stages. This study introduces a microstrip patch antenna coupled with artificial magnetic conductor (AMC) to realize improved sensor for non-invasive (early-stage) breast cancer and brain cancer diagnosis. The frequency selectivity of the proposed antenna has been increased by the presence of AMC by creating an additional resonance at 2.276 GHz associated...
-
Creating Dynamic Maps of Noise Threat Using PL-Grid Infrastructure
PublicationThe paper presents functionality and operation results of a system for creating dynamic maps of acoustic noise employing the PL-Grid infrastructure extended with a distributed sensor network. The work presented provides a demonstration of the services being prepared within the PLGrid Plus project for measuring, modeling and rendering data related to noise level distribution in city agglomerations. Specific computational environments,...
-
Monitoring of single-side lap grinding with electroplated tools
PublicationThe results presented in the paper show that utilising microphones as audible sound sensors is a suitable approach for monitoring a single-side lap grinding process due to the low levels of noise generated by the drives of a machine tool. The results confirm that sound signal analysis is a feasible and relatively simple method to monitor a lap grinding process with the use of an audible sound sensor. Proposed method can be used...
-
Tuning transfer function of fiber-optic Fabry-Pérot interferometer via introduction of birefringence in the cavity
PublicationThe study investigates the impact of birefringence exhibited by the cavity material of a fiber-optic Fabry-Pérot interferometer on its transfer function. The theoretical approach to analyze the effect of birefringence in the cavity of a plane Fabry-Pérot interferometer is described. The case of high- and low-finesse interferometer is investigated. It is shown that introduction of a birefringent medium of optimized parameters can...
-
The influence of small amount of substances present in tissue on the optical spectrum of immunosuppressive drug
PublicationIn this paper, we describe how commonly present in tissue substances - sodium chloride and glucose - affect the optical spectrum of an immunosuppressive drug (Cyclaid® by Apotex). Prepared samples were investigated using the spectrophotometer in the spectrum range from 250 nm to 1100 nm. The maximum wavelength shift calculated on the basis of measurement results is not bigger than the measurement wavelength step. So, it can be...
-
Magnetic field microsensor based on GaAs MESFET
PublicationA novel concept of the drain separation design in a horizontally-split-drain GaAs MAGFET sensor, based on epitaxial layer growth, was developed. Proper choice of GaAs/AlAs/GaAs epitaxial layer sequence provided good electrical isolation between the drain regions. The measured leakage current between the drain regions was in the range of nA for up to 2V drain voltage bias difference. Performed analytical and numerical calculations...
-
Badania nad potencjometrycznymi sensorami smaku
PublicationPrzedstwiono badania nad 5-kanałowym sensorem smaku kwasnego, zbudowanym z elektrod z membranami polimerowo - lipidowymi zawierającymi odpowiednie lipidy. Stwierdzono, że sensor ten jest bardzo czuły na zmainy stężenia kwasu cytrynowego, natomiast wykazuje nieco gorszą czułosc na obecnosć kwasu octowego. Stwirdzono dobrą trwałosć membran oraz powtarzalnośc otrzymanych wyników. Wydaje się, że badane układy mogą byc wykorzystane...
-
Wybrane aspekty oceny jakości produktów żywnościowych
PublicationPrzedstawiono wybrane aspekty oceny jakości produk tów żywnościo- wych: pojęcie jakości, wybrane metody oceny jakości ze szczególnym uwzględ- nieniem sztucznych potencjometrycznych sensorów sma ku składających się z szeregu elektrod typu ISE (Ion Selective Electrodes ) oraz ASSE (All Solid State Electrodes). Omówiono działanie sztucznych sensorów smaku. Przedstawiono 10 potencjometryczny sensor wprowadzony do obrotu hand lowego....
-
Design, Realization and Measurements of Enhanced Performance 2.4 GHz ESPAR Antenna for Localization in Wireless Sensor Networks
PublicationThis paper presents the design, realization and measurements of an Electronically Steerable Parasitic Array Radiator (ESPAR) antenna with enhanced performance of estimating the incoming signal direction. Designed antenna is dedicated for 2.4 GHz ISM applications with emphasis on Wireless Sensor Networks (WSN). Proposed antenna provides different radiation patterns by proper configuration of the parasitic elements. Thus, several...
-
Electrochemically directed biofunctionalization of a lossy-mode resonance optical fiber sensor
PublicationIn this work, we present a direct electrochemical biofunctionalization of an indium-tin-oxide-coated lossy-mode resonance optical fiber sensor. The functionalization using a biotin derivative was performed by cyclic voltammetry in a 10 mM biotin hydrazide solution. All stages of the experiment were simultaneously verified with optical and electrochemical techniques. Performed measurements indicate the presence of a poly-biotin...
-
Comparative study on the effectiveness of various types of road traffic intensity detectors
PublicationVehicle detection and speed measurements are crucial tasks in traffic monitoring systems. In this work, we focus on several types of electronic sensors, operating on different physical principles in order to compare their effectiveness in real traffic conditions. Commercial solutions are based on road tubes, microwave sensors, LiDARs, and video cameras. Distributed traffic monitoring systems require a high number of monitoring...
-
Assessment of Electronic Sensing Techniques for the Rapid Identification of Alveolar Echinococcosis through Exhaled Breath Analysis
PublicationHere we present a proof-of-concept study showing the potential of a chemical gas sensors system to identify the patients with alveolar echinococcosis disease through exhaled breath analysis. The sensors system employed comprised an array of three commercial gas sensors and a custom gas sensor based on WO3 nanowires doped with gold nanoparticles, optimized for the measurement of common breath volatile organic compounds. The measurement...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Gesture Recognition With the Linear Optical Sensor and Recurrent Neural Networks
PublicationIn this paper, the optical linear sensor, a representative of low-resolution sensors, was investigated in the multiclass recognition of near-field hand gestures. The recurrent neural network (RNN) with a gated recurrent unit (GRU) memory cell was utilized as a gestures classifier. A set of 27 gestures was collected from a group of volunteers. The 27 000 sequences obtained were divided into training, validation, and test subsets....
-
Post processing and selecting data obtain with parametric sub-bottom profiler SES-2000 Standard during sounding the Gulf of Gdansk
PublicationThe main goal of the paper is to describe the results of sounding the Gulf of Gdansk seabed using a parametric sub-bottom profiler SES-2000 Standard. Quality of obtained during trials data depends inter alia on proper location of antenna to reduce influence of pitch, roll, heave and ship noise (bubbles from propeller and a hull flow, vibration from main engine and peripheral devices). Furthermore calibration of complementary units...
-
Cost-Efficient Measurement Platform and Machine-Learning-Based Sensor Calibration for Precise NO2 Pollution Monitoring
PublicationAir quality significantly impacts human health, the environment, and the economy. Precise real-time monitoring of air pollution is crucial for managing associated risks and developing appropriate short- and long-term measures. Nitrogen dioxide (NO2) stands as a common pollutant, with elevated levels posing risks to the human respiratory tract, exacerbating respiratory infections and asthma, and potentially leading to chronic lung...
-
A method to monitor urinary carbon dioxide in patients with septic shock
PublicationSevere sepsis and septic shock are life-threatening conditions with mortality rates exceeding 31% (Levy et al., 2012) [1]. Septicemia was the most expensive US hospital condition in 2011 (Torio and Andrews, 2006)[2]. Urinary carbon dioxide may provide rapid, clinically useful information about a patient’s status, empowering physicians to intervene earlier and improve septic shock mortality. The objective of this paper is to validate...
-
Simultaneous optical and electrochemical label-free biosensing with ITO-coated lossy-mode resonance sensor
PublicationIn this work we discuss a new label-free biosensing device based on indium tin oxide (ITO) overlaid section of a multimode optical fiber fused silica core. The sensor has been used to optical measurements also simultaneously interrogated electrochemically (EC). Due to optimized thickness and optical properties of ITO film, a lossy-mode resonance (LMR) could be observed in the optical domain, where electrical properties of the film...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Inverse Modeling and Optimization of CSRR-based Microwave Sensors for Industrial Applications
PublicationDesign optimization of multivariable resonators is a challenging topic in the area of microwave sensors for industrial applications. This paper proposes a novel methodology for rapid re-design and parameter tuning of complementary split-ring resonators (CSRRs). Our approach involves inverse surrogate models established using pre-optimized resonator data as well as analytical correction techniques to enable rapid adjustment of geometry...
-
Impedimetric sensing of α-amino acids driven by micro-patterned 1,8-Diazafluoren-9-one into titania- boron- doped maze-like nanocarbons
PublicationThe development of impedimetric, non-faradaic label-free sensors for the detection of α-amino acids constitutes a trailblazing technology for the fast and inexpensive quantification of such biomarkers. Since α-amino acids, such as glycine and sarcosine, are basic constituents in biological processes, a variation in their concentration may be an indicator of cardiovascular diseases and metabolic disorders or neurological conditions....
-
Enhanced voice user interface employing spatial filtration of signals from acoustic vector sensor
PublicationSpatial filtration of sound is introduced to enhance speech recognition accuracy in noisy conditions. An acoustic vector sensor (AVS) is employed. The signals from the AVS probe are processed in order to attenuate the surrounding noise. As a result the signal to noise ratio is increased. An experiment is featured in which speech signals are disturbed by babble noise. The signals before and after spatial filtration are processed...
-
Silicon microcantilever with impedance sensor
Open Research DataThe issue of microelectromechanical systems (MEMS) [1] has been enjoying popularity and interest since the 90s of the 20th century. Microcells are one of the simplest devices of this type, but they can be widely used in sensors. There are reports on the possibility of using this type of sensors in the context of such important issues as diagnostics...
-
Asynchronous Networked Estimation System for Continuous Time Stochastic Processes
PublicationIn this paper we examine an asynchronous networked estimation system for state estimation of continuous time stochastic processes. Such a system is comprised of several estimation nodes connected using a possibly incomplete communication graph. Each of the nodes uses a Kalman filter algorithm and data from a local sensor to compute local state estimates of the process under observation. It also performs data fusion of local estimates...
-
Fiber optic microsphere with a ZnO thin film for potential application in a refractive index sensor – theoretical study
PublicationOptical fiber sensors of refractive index play an important role in analysis of biological and chemical samples. This work presents a theoretical investigation of spectral response of a fiber optic microsphere with a zinc oxide (ZnO) thin film deposited on the surface and evaluates the prospect of using such a structure for refractive index sensing. A microsphere is fabricated by an optical fiber tapering method on the base of...
-
Diagnostics of high-voltage varistor quality using resonant ultrasound spectroscopy
PublicationResonant spectroscopy is an effective nondestructive testing method focused on defects detection in tested objects. Resonance spectrum contains an information about the mechanical properties and particularly about the structural homogeneity of the whole object. A swept frequency method has been used to measure the selected resonant frequencies range. The system for measurement of resonant ultrasound spectroscopy of high-voltage...
-
Operational Enhancement of Numerical Weather Prediction with Data from Real-time Satellite Images
PublicationNumerical weather prediction (NWP) is a rapidly expanding field of science, which is related to meteorology, remote sensing and computer science. Authors present methods of enhancing WRF EMS (Weather Research and Forecast Environmental Modeling System) weather prediction system using data from satellites equipped with AMSU sensor (Advanced Microwave Sounding Unit). The data is acquired with Department of Geoinformatics’ ground...
-
Influence of vacuum sublimation deposited metal layer thickness on metrological parameters of the amperometric gas sensor with Nafion membrane
PublicationThe paper presents the results of investigation on an influence of vacuum sublimation deposited platinum layer thickness on the signal, sensitivity and response time of a prototype of sulphur dioxide sensor with Nafion membrane. The working electrode was made by vacuum sublimation deposition of platinum on a surface of Nafion membrane. Pt layers deposited changed an initial structure of Nafion membrane and that phenomenon was utilized...
-
Accuracy analysis of the RSSI BLE SensorTag signal for indoor localization purposes
PublicationIn this paper we describe possibility of use the RSSI signal (Radio Signal Strength Indication) from Texas Instruments SensorTag CC2650 for indoor positioning purposes. This idea is not a new but in our opinion it is possible to use SensorTags with Bluetooth LE wireless interface for positioning inside buildings in such applications as people findings in hospitals, senior come care, etc. RSSI is mostly selected as the sensor localization...
-
High Dynamic Range Microwave Displacement and Rotation Sensors Based on the Phase of Transmission in Groove Gap Waveguide Technology
PublicationThis research is focused on the design and realization of displacement sensors in gap waveguide technology. It is shown that with a small but fundamental change in the structure of a conventional gap waveguide, a linear displacement can be sensed. To this end, a unique feature of gap waveguides, i.e. the fact that no electrical connection between the top and bottom parts of the gap waveguide is required, is used. It is further shown...
-
An adaptive approach to non-destructive evaluation (NDE) of cast irons containing precipitated graphite particles with the help of magnetoacoustic emission
PublicationPhysical properties of cast irons strongly depend on both their microstructure and the presence of casting defects. The paper analyses the possibility of application of magnetoacoustic emission (MAE) for nondestructive detection of flawed cast iron components. The investigated samples containing dross, chunky graphite and lamellar graphite were compared with the reference, flawless, spheroidal cast iron sample. The optimisation...
-
Optical method supported by machine learning for urinary tract infection detection and urosepsis risk assessment
PublicationThe study presents an optical method supported by machine learning for discriminating urinary tract infections from an infection capable of causing urosepsis. The method comprises spectra of spectroscopy measurement of artificial urine samples with bacteria from solid cultures of clinical E. coli strains. To provide a reliable classification of results assistance of 27 algorithms was tested. We proved that is possible to obtain...
-
Remote Health Monitoring of Wind Turbines Employing Vibroacoustic Transducers and Autoencoders
PublicationImplementation of remote monitoring technology for real wind turbine structures designed to detect potential sources of failure is described. An innovative multi-axis contactless acoustic sensor measuring acoustic intensity as well as previously known accelerometers were used for this purpose. Signal processing methods were proposed, including feature extraction and data analysis. Two strategies were examined: Mel Frequency Cepstral...
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 194
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 194, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 192
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 192, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 191
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 191, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.