Search results for: CAST IRON DROSS CHUNKY GRAPHITE NONDESTRUCTIVE TESTING MAGNETOACOUSTIC EMISSION
-
An adaptive approach to non-destructive evaluation (NDE) of cast irons containing precipitated graphite particles with the help of magnetoacoustic emission
PublicationPhysical properties of cast irons strongly depend on both their microstructure and the presence of casting defects. The paper analyses the possibility of application of magnetoacoustic emission (MAE) for nondestructive detection of flawed cast iron components. The investigated samples containing dross, chunky graphite and lamellar graphite were compared with the reference, flawless, spheroidal cast iron sample. The optimisation...
-
Cavitation Erosion of Nodular Cast Iron - Microstructural Effects
PublicationThe paper deals with susceptibility of nodular cast iron with ferritic-pearlitic matrix on cavitation erosion. Cavitation tests were carried out with the use of a cavitation erosion vibratory apparatus employing a vibration exciter operated at frequency of 20 kHz. The study allowed to determine the sequence of subsequent stages in which microstructure of cast iron in superficial regions is subject to degradation. The first features...
-
Lack of magnetoacoustic emission in iron with 6.5% silicon
PublicationZjawisko emisji magnetoakustycznej (EMA) na ogół tłumaczy się dwoma przyczynami: ruchem nie 180-cio stopniowych granic domenowych (1) lub kreacją i anihilacją domen magnetycznych. Artykuł prezentuje silne dowody na poparcie faktu, że to właśnie ruch granic nie 180-cio stopniowych odpowiada za powstawanie efektu EMA. Wynika to z wyników pomiarów dających zerowe natężenie efektu EMA przeprowadzonych dla szerokiego zakresu naprężeń...
-
On the Application of Magnetoacoustic Emission for a Nondestructive Assessment of the Post Welding Heat Treatment of High Chromium Steel Weld Seams
PublicationThe paper analyses the possibility of post weld heat treatment (PWHT) quality assessment with the help of magnetoacoustic emission (MAE) signal measurements. Two welded superheater tubes, made of high chromium VM12 steel, were analysed—as welded and heat treated one. The analysed sample in the as welded state exhibited significantly higher hardness, accompanied by a big difference in the MAE signal intensity (of order of about...
-
Cast iron in the 19th-century building equipment
PublicationCast iron is a material, characteristics of which enable to receive extremely artistic elements. It maintains good strength properties at the same time. That combination of these seemingly contrary traits makes it a commodity that was widely used in the 19th century industry and architecture. These usages were not only as decorative elements, technical and structural ones. The production of new household utilities started, which...
-
Diagnostics of zno varistors by means of nondestructive testing
PublicationStandard industrial testing of high-voltage varistors for surge arresters demands application of high voltages and intensive currents. Nondestructive methods for varistor quality and endurance evaluation have been proposed and described. They rely on the application of resonant ultrasound spectroscopy, electro-ultrasonic spectroscopy, noise measurement and nonlinearity testing at voltages lower than continuous operating range....
-
Conservation aspects of cast-iron platform shelters on the example of Vistula Pomerania railway stations
PublicationCast-iron shelters were used in the 19th century as cheaper alternatives to large platform halls. Nevertheless, they were aesthetically distinguishable from later riveted solutions. Because of their durability and continuous utility, they were not the subject of disassembly, as numerous transport infrastructure objects have been in recent decades. This article aims to indicate proper conservation practices during construction works...
-
Cast Iron Staircase in Aleksandrów Kujawski (Poland) - History, Construction, Architectural Form
PublicationThe text presents historic cast iron staircase, which is situated inside the railway station building in Aleksandrów Kujawski. Since the moment of creation in the 19th century for a long time that station, located at the border of Prussia and Kingdom of Poland, was an important transit point. Nowadays it is situated in the central of Poland. The staircase was built in 1870’s as a result of an extension of the railway station building...
-
Nondestructive Testing of the Miter Gates Using Various Measurement Methods
PublicationWhen any problems related to civil engineering structures appear, identifying the issue through the usage of only one measuring method is difficult. Therefore, comprehensive tests are required to identify the main source. The strains and displacement measurements, as well as modal identification, are widely used in the nondestructive testing of structures. However, measurements are usually carried out at several points and confirm...
-
Modeling of effect of plastic deformation on Barkhausen noise and magnetoacoustic emission in iron with 2% silicon
PublicationW modelowaniu zaadaptowano model Alessandro-Beatrice-Bertotti-Montorsi dla opisu ruchu granic nie-180 stopniowych oraz model Jiles-Atherton dla opisu wpływu plastycznej deformacji na natężenie efektu Barkhausena oraz emisji magnetoakustcznej.
-
Evaluation of Barkhausen Noise and Magnetoacoustic Emission Signals Properties for Plastically Deformed Armco Iron
PublicationArtykuł prezentuje wyniki badania wpływu różnych rodzajów deformacji plastycznej na właściwości magnetoakustyczne żelaza Armco. Badane były dwie serie próbek - pierwsza składała się ze wstępnie wyżarzonych próbek, które następnie były walcowane na zimno, w skład drugiej wchodziły natomiast próbki wycięte z komercyjnie dostępnej blachy wykonanej z żelaza Armco a następnie poddane obciążeniom rozciągającym. Walcowanie na zimno prowadzi...
-
Study on 19th-century cast iron columns from the former financial office building in Kwidzyn
PublicationThe article presents the results for cast iron columns used as floor supports in the former financial office building in Kwidzyn (Poland).The stocktaking drawings provided the general and detailed data about the 19th century designer’s decisions. During the research, architectural and structural analysis was carried out. The graphics were used as a starting material for preparing 3D calculation models. The FEM-based numerical simulations...
-
On the correlation between magnetoacoustic emission and magnetostriction dependence on the applied magnetic field
PublicationThe correlation between magnetoacoustic emission signal envelopes and magnetostriction curves is investigated. Two sets of samples are being considered: tempered martensitic steel and plastically deformed ferritic steel. It is shown that even though some general relations may be observed, as was demonstrated in the literature, the correlation is not always present. One may not expect to change both quantities in the same way if...
-
Charging of the cast iron lapping tools.
PublicationPrzedstawiono technikę i technologię zbrojenia wymuszonego powierzchni docieraków tarczowych. Omówiono konstrukcję przyrządu oraz wyniki badań intensywności zbrojenia docieraków mikroziarnami węglika krzemu. Analizowano docieraki z żeliwa szarego i sferoidalnego oraz mikroziaren o numerze 320 i 300.
-
Images of topography and mechanical properties (phase imaging) of cast iron samples from water installations
Open Research DataMeasurements in contact and semi-contact mode. NTEGRA Prima (NT-MDT) device. CSG 10.
-
RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING
Journals -
Study of microstress state of P91 steel using complementary mechanical Barkhausen, magnetoacoustic emission, and X-ray diffraction techniques
PublicationThe paper deals with assessment of microstress state of martensite P91 steel using three complementary techniques: mechanical Barkhausen emission, magnetoacoustic emission (MAE), and X-ray diffraction (XRD) profile analysis. Magnetic coercivity Hc and microstructure were investigated with inductive magnetometry and magnetic force microscopy (MFM), respectively. Internal stress level of P91 steel was modified by heat treatment....
-
Excavation induced cast iron pipeline failure – a numerical study
PublicationNumerical study on impact of an unsecured excavation on an underground pipeline. Analysis focused on investigation of pipeline displacement generated by soil movement caused by excavation and heavy traffic. Numerical calculations and soil parameter sensitivity analysis based on Finite Element Method. Some comparisons of results with real-life failure cases.
-
Porosity and shape of airborne wear microparticles generated by sliding contact between a low-metallic friction material and a cast iron
PublicationThe wear of brakes in transport vehicles is one of the main anthropogenic sources of airborne particulate matter in urban environments. The present study deals with the characterisation of airborne wear microparticles from a low-metallic friction material / cast iron pair used in car brakes. Particles were generated by a pin-on-disc machine in a sealed chamber at sliding velocity of 1.3 m/s and contact pressure of 1.5 MPa. They...
-
Nondestructive Characterization of 2CR-1Mo Steel Quality Using Magnetoacousting Emission
PublicationPrzedstawiono wyniki badań własności emisji magneto-akustycznej (EMA) oraz własności magnetycznych (pętla histerezy magnetycznej, efekt Barkhausena, magnetostrykcja) dla wycinków rur stali 2Cr-1Mo o różnym stopniu degradacji. Wykazano, iż początkowy etap degradacji skutkuje w obniżeniu natężenia EMA oraz magnetostrykcja także niewielką zmianą pola koercji i nie monotoniczną zmianą natężenia efektu Barkhausena).
-
Modeling incipient creep damage effects on Barkhausen noise and magnetoacoustic emission.
PublicationZaproponowano model fizyczny opisujący zmiany natężenia efektu Barkhausena i emisji magnetoakustycznej podczas procesu degradacji stali ekploatowanych w przemyśle energetycznym.
-
Journal of the Korean Society for Nondestructive Testing
Journals -
Case Studies in Nondestructive Testing and Evaluation
Journals -
Possibility of Application of Magnetoacoustic Emission for the Assessment of Plastic Deformation Level in Ferrous Materials
PublicationArtykuł prezentuje wyniki badań dotyczących możliwości zastosowana emisji magnetoakustycznej (EMA) do nieniszczącej oceny stopnia deformacji plastycznej próbek poddanych jednoosiowemu rozciąganiu. Przebadane zostały cztery różne materiały: stale 13HMF, CSN12021 i P91 oraz żelazo Armco. Badania pokazały, że różne parametry magnetyczne i magnetoakustyczne badanych materiałów mogą zmieniać się w rożny sposób, jednakże zawsze obserwuje...
-
Nondestructive Testing and Evaluation
Journals -
On the Use of Automatic Cuts Algorithm for T0 – T – Φ Formulation in Nondestructive Testing by Eddy Current
Publication -
A tribological research on a reciprocating sliding contact of aluminum-ferrous composite against cast-iron.
PublicationOpisano badania kompozytów: silumin AlSi11-żelazo albo silumin AlSi11-stal narzędziowa N9 (otrzymanych in situ), a także samego siluminu AlSi11 w skojarzeniu z żeliwem 350, przy tarciu ślizgowym w ruchu posuwisto-zwrotnym. Stwierdzono wpływ sposobu otrzymywania materiału kompozytowego na zużycie i opory ruchu skojarzenia badawczego, w szczególności materiały te zużywały się wolniej, niż silumin AlSi11.
-
The influence of elastic deformation on the properties of the magnetoacoustic emission (mae) signal for go electrical steel
PublicationZbadano własciwości sygnału emisji magnetoakustycznej (MAE) elektrotechnicznej stali GO poddanej deformacji plastycznej w temperaturze pokojowej
-
On the Microstructure, Microhardnessand Wear Behavior of Gray Cast Iron Surface Layer after Laser Strengthening
Publication -
On the possibility of the application of magnetoacoustic emission intensity measurements for the diagnosis of thick-walled objects in the industrial environment
PublicationArtykuł przedstawia wyniki pomiarów sygnału emisji magnetoakustycznej (EMA) wykonanych na obiektach grubościennych w środowisku przemysłowym oraz omawia możliwe sposoby jego dalszej analizy. Pomimo tego, ze bezpośredni pomiar sygnału EMA nie pozwala na określenie jego natężenia w artykule wykazano, że możliwa jest separacja użytecznego sygnału od szumów tła albo poprzez analogowe filtrowanie sprzętowe albo poprzez cyfrową analizę...
-
Designing a magnetoacoustic emission measurement configuration for measurement of creep damage in power plant boiler tubes
PublicationOpisywane są własności skonstruowanego detektora emisji magneto-akustycznej (EMA) służącego dla pomiaru stopnia degradacji rurociągów w przemyśle energetycznym. Specjalna budowa biegunów magnesu umożliwia ich dopasowanie do zakrzywionych powierzchni. Układ pomiarowy pozwala na badanie natężenia EMA dla pola wzdłuż osi rury, a także w kierunku obwodowym. Wykazano, iż możliwa jest detekcja zmiany stopnia degradacji materiału na obwodzie...
-
Comparison of properties of magnetoacoustic emission and mechanical Barkhausen effects for P91 steel after plastic flow and creep
PublicationW artykule przedstawiono wyniki pogłębionej analizy sygnału szumowego efektu Barkhausena dla próbek ze stali krzemowej Fe-2%Si po deformacji plastycznej. Badane były próbki po walcowaniu na zimno powodującym odkształcenie względne w zakresie do 8%. Pierwsze podejście polegało na analizie w dziedzinie czasu widma badanego sygnału. Analiza ta została uzupełniona o analizę liczby zliczeń impulsów w funkcji napięcia progowego, zarówno...
-
Impact of eddy currents on Barkhausen and magnetoacoustic emission intensity in a steel plate magnetized by a C-core electromagnet.
PublicationZbadano (zmierzono i modelowano metodą elementów skończonych) wpływ częstości magnesowania na przestrzenny i czasowy rozkład indukcji magnetycznej wewnątrz płyty stalowej. Wyznaczono i zmierzono natężenie polowego rozkładu Barkhausena (HEB) na powierzchni płyty oraz natężnie emisji magnetoakustycznej (EMA) z całej magnesowanej objętości. Wykazano, iż obserwowane zmiany w natężeniu HEB i EMA są wynikiem zmian w rozkładzie indukcji...
-
Evaluation of physical indicators and tool wear during grooving of spheroidal cast iron with a novel WCCo/cBN (BNDCC) inserts
Publication -
Application of dynamic impedance spectroscopy to scanning probe microscopy.
PublicationDynamic impedance spectroscopy, designed for measuring nonstationary systems, was used in combination with scanning probe microscopy. Using this approach, impedance mapping could be carried-out simultaneously with topography scanning. Therefore, correlation of electrical properties with particular phases of an examined sample was possible. The sample used in this study was spheroidal graphite cast iron with clearly defined phases...
-
Emission of 1.3–10 nm airborne particles from brake materials
PublicationOperation of transport vehicle brakes makes a significant contribution to airborne particulate matter in urban areas, which is subject of numerous studies due to the environmental concerns. We investigated the presence and number fractions of 1.3–10 nm airborne particles emitted from a low-metallic car brake material (LM), a non-asbestos organic car brake material (NAO) and a train brake cast iron against a cast iron. Particles...
-
Application of polyethylene glycol-coated iron oxide nanoparticles for magnetic solid phase extraction of copper from seawater samples and its determination by graphite furnace atomic absorption spectrometry using response surface methodology for optimization of extraction
Publication -
Arkadiusz Szewczyk dr inż.
PeopleArkadiusz Szewczyk obtained his MSc title in electronics, specialization electronic equipment at Gdańsk University of Technology, Faculty of Electronics, Telecommunications and Informatics. The PhD title he obtained in 2002 as a result of cooperation between GUT and l' Institut National Polytechnique de Grenoble, France, where he was a student of doctoral college. Currently he is an assistant professor in Department of Metrology...
-
Krzysztof Wilde prof. dr hab. inż.
PeopleKrzysztof Wilde (born January 11th, 1966 in Gdańsk) – expert in bridge structures, structural mechanics and diagnostics of civil structures. He conducted research on vibration reduction systems for bridges exposed to dynamic loads from winds and earthquakes. At present he is interested in the field of nondestructive testing of materials and structural health monitoring systems. Hi is author or coauthor of over 200 publications...
-
Electrical and mechanical characterization of two-phase alloys by means of scanning probe microscopy in dynamic impedance spectroscopy mode
PublicationDynamic impedance spectroscopy, evaluated for measuring non-stationary systems, was used in combination with scanning probe microscope. Using this approach, localized impedance measurements in the AFM contact mode could be carried out. Additionally, impedance–force curves were made at each phase of investigated materials to illustrate the relation between impedance and the force applied to a probe. Therefore, correlation of electrical...
-
Study on the applicability of the measurements of magnetoelastic properties for a nondestructive evaluation of thermally inducted microstructure changes in the P91 grade steel
PublicationThe paper presents the resuIts of the investigation of the influence of duration and temperature oftempering process on the magnetoacoustic properties of P91 tempered martensite ferritic steeI. Duringtempering of martensitic steels the dislocation density. which initially is very high. systematicallydecreases what is confirmed both by analysis of the width of X-ray diffraction peaks and hardnessmeasurements. Magnetic hysteresis...
-
Wpływ rodzaju zanieczyszczenia powierzchni odlewu ze staliwa LH14 na jakość napoin wykonanych elektrodą otuloną
PublicationNapawanie jest szeroko stosowaną metodą naprawiania powierzchni. Pozwala między innymi na uzupełnienie miejsc, w których uprzednio wystąpiły wżery korozyjne. Techniki napawania wykorzystywane są również do przywracania pierwotnego kształtu zużytych części. W pracy wykonano badania napoin wykonanych elektrodami otulonymi na czołowych powierzchniach cylindrycznych próbek ze staliwa LH14. Proces wykonywano dwoma rodzajami elektrod:...
-
Michał Kwasek dr inż. arch.
PeopleMichał Kwasek works as the assistant in Department of Technical Fundamentals of Architectural Design at the Faculty of Architecture of the Gdansk University of Technology (GUT). In 2009, he graduated from the Faculty of Civil and Environmental Engineering of GUT, and in 2013 he defended his master's degree in Architecture and Urban Planning at the Faculty of Architecture at GUT. In the same year, he began his studies at the Doctoral...
-
Impact of Tensile and Compressive Stress on Classical and Acoustic Barkhausen Effects in Grain-Oriented Electrical Steel
PublicationIn this paper, we present the results of the investigation of impact of tensile and compressive stress on the classical Barkhausen effect, magnetoacoustic emission (MAE) signal properties, and B(H) hysteresis loops for grain-oriented (GO) electrical steel. Samples have been glued to a nonmagnetic steel bar and stressed within elastic range (±800 μdef) by means of four-point bending method. The samples were cut out in two directions...
-
Prediction of the Mechanical Properties of P91 Steel by Means of Magneto-acoustic Emission and Acoustic Birefringence
PublicationThe paper describes an application of nondestructive volumetric magnetic and ultrasonic techniques for evaluation of the selected mechanical parameter variations of P91 steel having direct influence on its suitability for further use in critical components used in power plants. Two different types of deformation processes were carried out. First, a series of the P91 steel specimens was subjected to creep and second, one to plastic...
-
Analysis of the possibility of creep damage detection in T24 heat resistant steel with the help of magnetic nondestestructive testing methods
PublicationThe paper presents the result of an analysis of applicability of various electromagnetic methods of nondestructive evaluation for creep damage detection in a novel heat resistant steel - T24 grade. Two sample sets, cut out from membrane wall tubes, were investigated – the as-delivered one and another exploited for 36,000 h in a power plant. There are described results of magnetic hysteresis loops B(H), Barkhausen noise (BN) and...
-
Evaluation of Mechanical Properties of Two-Stage Concrete and Conventional Concrete Using Nondestructive Tests
PublicationDifferent types of concrete mixtures are used as building materials. The manufacturing process of two-stage concrete (TSC) differs from that of conventional concrete. This study investigated conventional mechanical properties derive empirical relations for estimation of the mechanical parameters of TSC and conventional concrete mixtures. TSC was used to prepare 216 specimens and conventional concrete was used to prepare 108 specimens...
-
Influence of dispersed phase content on the mechanical properties of electroless nanocomposite Ni-P/Si3N4 and hybrid Ni-P/Si3N4/graphite layers deposited on the AW-7075 alloy.
PublicationThe article presents the results of mechanical testing of Ni-P/Si3N4 nanocomposite and hybrid Ni-P/Si3N4/graphite coatings deposited on AW-7075 aluminum alloy using the chemical reduction method. In terms of mechanical testing, microhardness was measured, and surface roughness and adhesion of the coatings to the aluminum substrate were determined using the “scratch test” method. The surface morphology of the deposited layers was...
-
Analysis of the construction, assembly and usage of specialized fixtures illustrated with an example of machining a lever
PublicationThe paper presents a method of quantitative assessment of manufacturability of the construction of specialized fixtures used in machining. The assumed, simplified assessment criteria include both the complexity of the construction with respect to time-consumption of manufacturing the components and their assembly, as well as the features of the usage of fixtures. The paper contains a study case connected with variably designed...
-
A universal NDT method for examination of low energy impact damage in CFRP with the use of TLC film
PublicationThe article presents an attempt to use a sheet of laminated thermochromic liquid crystal film (TLC film) for non-destructive testing of the impact damage (energy values: 1J, 2J, 3J and 4J) in carbon fibre-reinforced polymer (CFRP). This is a new, alternative NDT approach based on the thermo-optical effect. The main advantages of this method are a) the low cost of TLC film, b) the low cost of recording devices due to the usage of...
-
A study on diagnosing both isotropic and orthotropic, intentionally damaged laminates
PublicationBeing the most detrimental mode in laminated structures, delamination initially degrades local structural strength, and lastly causes global structural failure, thus necessitating delamination identification at its incipient stages. For identification purposes, a comprehensive numerical and experimental study on delamination within both the laminated isotropic acrylic-glass and orthotropic epoxyglass plates is presented. As the...
-
A Study on Emission of Airborne Wear Particles from Car Brake Friction Pairs
PublicationThe emission of airborne wear particles from friction material / cast iron pairs used in car brakes was investigated, paying special attention to the influence of temperature. Five low-metallic materials and one non-asbestos organic material were tested using a pin-on-disc machine. The machine was placed in a sealed chamber to allow airborne particle collection. The concentration and size distribution of 0.0056 to 10 μm particles...
-
Reverberation chamber in emc tests of naval systems
PublicationPaper covers the techniques of emission and immunity testing to the electromagnetic field in reverberation chamber. The procedure of he chamber calibration and field homogeneity assessment were covered. The naval forces' product as selected as an example for discussing the testing procedure in the chamber. The paper's summary gives the assortment of methodology in radiation emission testing and immunity to the electromagnetic field...
-
Airborne wear particle emission from train brake friction materials with different contents of steel and copper fibres
PublicationThis study investigated the influence of the amount of steel and copper fibres in a train brake friction material on the tribological performance, emission intensity and characteristics of airborne wear particles. The particles were generated on a pin-on-disc tribometer under controlled friction and environmental conditions. It was found that the steel fibre results in a more intensive emission of 0.3–10 μm particles compared to...
-
Diagnostics of high-voltage varistor quality using resonant ultrasound spectroscopy
PublicationResonant spectroscopy is an effective nondestructive testing method focused on defects detection in tested objects. Resonance spectrum contains an information about the mechanical properties and particularly about the structural homogeneity of the whole object. A swept frequency method has been used to measure the selected resonant frequencies range. The system for measurement of resonant ultrasound spectroscopy of high-voltage...
-
In-situ odd random phase electrochemical impedance spectroscopy study on the electropolymerization of pyrrole on iron in the presence of sodium salicylate – The influence of the monomer concentration
PublicationIn this work, the potentiostatic electropolymerization of polypyrrole (PPy) on iron in aqueous solution of sodium salicylate and pyrrole is studied in situ by odd random phase electrochemical impedance spectroscopy (ORP-EIS). The influence of the pyrrole concentration on the electrosynthesis process is investigated. The ORP-EIS technique ensures a reliable analysis of the PPy electrosynthesis on iron by means of an advanced data...
-
Identyfikacja gatunku stali zastosowanej w obiektach budowlanych
PublicationEksploatacja istniejących metalowych konstrukcji budowlanych często związana jest z zagadnieniem koniecznej szczegółowej identyfikacji rodzaju materiału stalowego pod kątem je go cech wytrzymałościowych i składu chemicznego. Dostępne standardowe metody laboratoryjne zazwyczaj wymagają pobrania z konstrukcji próbek materiału do badań, co nie zawsze jest możliwe. W artykule zaprezentowano alternatywne metody oceny wymienionych cech...
-
Analysis of Agricultural and Engineering Systems using Simulation Decomposition
PublicationThis paper focuses on the analysis of agricultural and engineering processes using simulation decomposition (SD). SD is a technique that utilizes Monte Carlo simulations and distribution decomposition to visually evaluate the source and the outcome of different portions of data. Here, SD is applied to three distinct processes: a model problem, a nondestructive evaluation testing system, and an agricultural food-water energy system....
-
Influence of reactive oxygen species during deposition of iron oxide films by high power impulse magnetron sputtering.
PublicationIron oxide films were deposited using high power impulse magnetron sputtering (HiPIMS) of an iron cathode in an argon/oxygen gas mixture at different gas pressures (0.5~Pa, 1.5~Pa, and 5.0~Pa). The HiPIMS system was operated at a repetition frequency $f = 100$~Hz with a duty cycle of 1~\%. A main goal is a comparison of film growth during conventional and electron cyclotron wave resonance-assisted HiPIMS. The deposition plasma...
-
Noise and Electro-Ultrasonic Spectroscopy of Conducting PolymerThick Films
PublicationThick conducting films based on conducting polymer are characterized by DC conductivity and noise in temperature range 10 to 300 K. Conducting polymers could be used e.g. for the top electrode (cathode) in the solid tantalum or niobium capacitors. On the conducting polymer layer the top layer of carbon/graphite and/or silver polymer based pastes is applied in the capacitor technology. Our samples structure consists of conducting...
-
Electrochemical investigations on corosivity of de-icing liquids for railway infrastructure
PublicationThe paper presents the results of electrochemical tests of the de-icing fluid for railway infrastructure. DC and AC electrochemical tests were performed to determine the corrosion rates of structural steel, cast iron and aluminium in the newly produced fluid. The results were compared with the corrosion rates of the same materials in the fluid without corrosion inhibitors. The obtained test results indicate a low corrosion risk...
-
Monitoring of underdeck corrosion by using acoustic emission method
PublicationThis paper presents first short characteristics of underdeck corrosion process as well as a problem of its monitoring. Next is described an acoustic emission (AE) method elaborated by Department of Ship Technology , Quality Systems and Material Engineering, Gdańsk University of Technology in cooperation with partners of CORFAT project realized within 7th EU Frame Program . Further are presented short characteristics of the emission...
-
Mercury intrusion porosimetry (MIP) results of cement pastes containing iron oxide (Fe3O4) nanoparticles (nanomagnetite)
Open Research DataMercury intrusion porosimetry (MIP) data - curves of cement pastes containing iron oxide (Fe3O4) nanoparticles (nanomagnetite) in *.opju (Origin) format.
-
ADT in mammography
PublicationWe discuss limitations of the known methods of IR imaging in diagnostics of breast cancer. In conclusion we show that for practical reasons one requires new approaches because the known methods based on simple observation of external temperature distribution are not fully effective. Even advanced pattern recognition could not help too much for static images. We ask the question: may active dynamic thermography, known in nondestructive...
-
On the application of magnetoelastic properties measureme nts for plastic level determination in martensitic steels
PublicationThe change in the dislocation density, induced by plastic deformation, influences strongly the magnetic domain structure inside the material. Being so, classic parameters, like the coercivity or magnetic permeability, can be a good measure of the deformation level, yet their reliable determination in a non-destructive way in industrial environment is problematic. The magnetoacoustic emission (MAE) which results from the non-180...
-
APPLICATION POSSIBILITIES OF THE S960 STEEL IN UNDERWATER WELDED STRUCTURES
PublicationIn this paper, the application possibilities of the ultra-high strength (UHSS). Domex 960 steel in the underwater welded structures are analyzed. In the research, the investigated material has been tested in bead-on-plate wet welding conditions with the usage of different heat input values, namely 0.63 kJ/mm, 0.72 kJ/mm and 0.93 kJ/mm. Specimens were performed by the manual metal arc (MMA) welding method with the usage of rutile...
-
Optoelectronic system for monitoring of thin diamond layers growth
PublicationDevelopment of the optoelectronic system for monitoring of diamond/DLC (Diamond-Like-Carbon) thin films growth during mu PA ECR CVD (Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition) process is described. The multi-point Optical Emission Spectroscopy (OES) and Raman spectroscopy were employed as non-invasive optoelectronic tools. Dissociation of H-2 molecules, excitation and ionization of hydrogen...
-
Mineral Composition of Dietary Supplements-Analytical and Chemometric Approach
PublicationThere is a lack of data on the actual composition and effectiveness of beetroot-based dietary supplements. The research aimed to determine the profile of 22 elements (Na, K, Ca, Mg, P, Fe, As, Se, Zn, Cu, Ag, Co, Ni, Mo, Al, Mn, Sr, Cr, Ba, Li, Pb, Cd) in beetroot and its supplements by the microwave plasma atomic emission spectrometry (MP-AES) method. The analytical procedure was optimised and validated. The composition of both...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #3The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #5.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #5.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,8 V at 241 mA. Sample 24, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,8 V and discharged to 10 mV by constant current 241 mA, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 250 mA. Sample 24.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 250 mA. Last experiment with sample 24The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 180 mA. Sample 24
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 180 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 80 mA. Sample 41.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 80 mA. Sample 41.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #2The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 250 mA. Sample 23, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 250 mA. Sample 23, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,8 V at 241 mA. Sample 24, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,8 V and discharged to 10 mV by constant current 241 mA, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,8 V at 241 mA. Sample 24, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,8 V and discharged to 10 mV by constant current 241 mA, experiment run #3.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,9 V at 241 mA. Sample 24, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,9 V and discharged to 10 mV by constant current 241 mA, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 241 mA. Sample 24
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 241 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 250 mA. Sample 23, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 250 mA. Sample 23, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 80 mA. Sample 24
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 80 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #4.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #4.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,9 V at 241 mA. Sample 24, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,9 V and discharged to 10 mV by constant current 241 mA, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 301 mA. Sample 24
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 301 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 160 mA. Sample 41.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 160 mA. Sample 41.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 120 mA. Sample 24
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 120 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,1 V at 561 mA. Sample 71, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,1 V and discharged to 10 mV by constant current 561 mA. Sample 71, experiment run #3.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 112 mA. Sample 71.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 112 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,1 V at 561 mA. Sample 71, run #4.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,1 V and discharged to 10 mV by constant current 561 mA. Sample 71, experiment run #4.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 108 mA. Sample 61.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 108 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #7.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #7. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 135 mA. Sample 61.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 135 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #6.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #6. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,1 V at 561 mA. Sample 71, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,1 V and discharged to 10 mV by constant current 561 mA. Sample 71. Experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,4 V at 562 mA. Sample 71.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,4 V and discharged to 10 mV by constant current 562 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 240 mA. Sample 42.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 240 mA. Sample 42.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 561 mA. Sample 71, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 561 mA. Sample 71. Experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 224 mA. Sample 71.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 224 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...