Filters
total: 9552
-
Catalog
- Publications 3081 available results
- Journals 38 available results
- Conferences 1 available results
- People 173 available results
- Inventions 3 available results
- Projects 19 available results
- Laboratories 1 available results
- Research Teams 3 available results
- Research Equipment 2 available results
- e-Learning Courses 5814 available results
- Events 15 available results
- Open Research Data 402 available results
displaying 1000 best results Help
Search results for: SHM, MONITORING
-
Monitoring of odour nuisance on the adjacent areas to the landfill using fast GC and sensory analysis
PublicationThe paper shows the results of investigation on classification of the atmospheric air samples collected in a vicinity of the landfill during August and September period have been presented. The studies was conducted by the use of Fast GC HERACLES II from AlphaMOS company and sensory analysis. About 86% of the atmospheric air samples ollected were classified correctly using PCA and LDA. Based on a classification of the atmospheric...
-
Simple gait parameterization and 3D animation for anonymous visual monitoring based on augmented reality
PublicationThe article presents a method for video anonymization and replacing real human silhouettes with virtual 3D figures rendered on a screen. Video stream is processed to detect and to track objects, whereas anonymization stage employs animating avatars accordingly to behavior of detected persons. Location, movement speed, direction, and person height are taken into account during animation and rendering phases. This approach requires...
-
Ribosomal intergenic spacer analysis as a tool for monitoring methanogenic archaea changes in an anaerobic digester
PublicationThe applicability of a newly-designed PCR primer pair in examination of methanogenic Archaea in a digester treating plant biomass was evaluated by Ribosmal Intergenic Spacer Analysis (RISA). To find a suitable approach, three variants of RISA were tested: (1) standard, polyacrylamide gel-based, (2) automated, utilized capillary electrophoresis (GA-ARISA), and (3) automated microfluidics-based (MF-ARISA). All three techniques yielded...
-
Identification of acoustic event of selected noise sources in a long-term environmental monitoring systems
PublicationABSTRACT Undertaking long-term acoustic measurements on sites located near an airport is related to a problem of large quantities of recorded data, which very often represents information not related to flight operations. In such areas, usually defined as zone of limited use, often other sources of noise exist, such as roads or railway lines treated is such context as acoustic background. Manual verification of such recorded data...
-
Deduplication of Position Data and Global Identification of Objects Tracked in Distributed Vessel Monitoring System
PublicationVessel monitoring systems (VMS) play a very important role in safety navigation. In most cases, their structure is distributed and they are based on two data sources, namely Automatic Identification System (AIS) and Automatic Radar Plotting Aids (ARPA). Such approach results in several objects identification and position data duplication problems, which need to be solved in order to ensure the correct performance of a given VMS....
-
Deduplication of Tracked Objects Position Data at Single Observation Point of a Vessel Monitoring System
PublicationVessel Monitoring System (VMS) play a major role in safety navigation. In most cases they are based on two data sources, namely Automatic Identification System (AIS) and Automatic Radar Plotting Aids (ARPA). Integration of data obtained from these sources is an important problem, which needs to be solved in order to ensure the correct performance of a given VMS. In this paper basic functions which should be implemented in a tracked...
-
Monitoring górnej sieci trakcyjnej z wykorzystaniem bezprzewodowej sieci sensorowej – węzeł pomiarowy
PublicationWraz ze wzrostem prędkości pojazdów trakcyjnych rośnie potrzeba utrzymania sieci trakcyjnej w odpowiednim stanie technicznym. Konieczny jest ciągły monitoring i diagnostyka pozwalające wykrywać zjawiska pogarszające jakość odbioru energii z sieci trakcyjnej. Jedną z metod jest umieszczenie czujników przyspieszenia na górnej sieci trakcyjnej. Analiza przebiegu tej wielkości fizycznej pozwoli określić stan układu sieć jezdna - odbierak...
-
Investigation of Noise-Induced Instabilities in Quantitative BiologicalSpectroscopy and Its Implications for Noninvasive Glucose Monitoring
PublicationPrzedstawiono sposób oceny błędów jakie pojawiają się przy estymacji poziomu glukozy we krwi za pomocą pomiarów widm Ramana. Zastosowano nieliniowy algorytm regresji według maszyny wektorów nośnych. Określono jak na wyznaczenie stężenia glukozy we krwi wpływają błędy pomiarów widmach Ramana oraz błędów pomiaru referencyjnego stężenia glukozy podczas etapu kalibracji modelu (etapu uczenia algorytmu maszyny wektorów nośnych). Określono...
-
Networked Object Monitor - A distributed system for monitoring, diagnostics and control of complex industrial facilities
PublicationRozwój mobilności i technologii internetowych, a także globalizacji gospodarki światowej, uwzględniający kluczowe aspekty zarządzania przepływem informacji, otworzył zupełnie nowe możliwości opracowywania i konstruowania innowacyjnych rozwiązań technicznych. Z taką myślą powstał prototyp Sieciowego Monitora Obiektu, aplikacji umożliwiającej nie tylko ciągłą kontrolę parametrów obiektów przemysłowych i biznesowych, ale również zarządzanie...
-
Alternative diagnostic method applied on marine diesel engines having limited monitoring susceptibility
PublicationThe paper presents a method of technical state evaluation of working spaces of a marine diesel engine at the limited control susceptibility. The method foresees making a diagnosis of the engine's working spaces on the basis of measurements of the exhaust gas pressure in the channels connecting engine cylinders with the turbocharger's turbine. Diagnostic measurements are carried out at representative (comparative) steady loads depending...
-
Testing and sampling devices for monitoring volatile and semi-volatile organic compounds in indoor air
PublicationAdults spend most of their time in enclosed spaces (e.g., apartment, office and public buildings). According to research conducted by scientists, air quality indoors is much worse than the ambient air quality outdoors. Hazardous chemicals found in air indoors can adversely affect the functioning of the human body and cause many respiratory and circulatory diseases. Harmful chemical compounds (mainly volatile organic compounds and...
-
An application of neural network for Structural Health Monitoring of an adaptive wing with an array of FBG sensors
PublicationW pracy przedstwiono możliwości zastoswania sieci czujników FBG i sztucznych sieci neuronowych do detekcji uszkodzeń w poszyciu adaptacyjnego skrzydła.
-
Novel condition monitoring of induction motor bearings via motor current signature analysis
PublicationThe paper authors are researching the assessment of bearing conditions in induction motors. The methods developed by the authors are based on measurements and analysis of the motor supply current, which is particularly attractive in the absence of access to the engine. The article provides an overview of selected methods of induction motor bearings diagnostic based on Motor Current Signature Analysis (MCSA). However, there is no...
-
Failure Monitoring and Condition Assessment of Steel-Concrete Adhesive Connection Using Ultrasonic Waves
PublicationAdhesive bonding is increasingly being incorporated into civil engineering applications. Recently, the use of structural adhesives in steel-concrete composite systems is of particular interest. The aim of the study is an experimental investigation of the damage assessment of the connection between steel and concrete during mechanical degradation. Nine specimens consisted of a concrete cube and two adhesively bonded steel plates...
-
Monitoring. Wybrane problemy związane z oceną stanu cięgien wielosplotowych w mostach
PublicationW referacie przedstawiono wyniki analiz prowadzonych przy opracowaniu architektury monitoringu mostu podwieszonego przez Wisłok w Rzeszowie. Dokonano tam klasyfikacji zmian, jakimi konstrukcja podlega w czasie i wykonano szereg obliczeń pozorujących uszkodzenia w linach podwieszenia. Wnioski opracowane w wyniku analizy mają charakter uniwersalny i mogą być wykorzystane przy opracowaniu systemu monitoringu mostów, w których zastosowano...
-
Cameras, microphones, and data storage in current monitoring systems.Technology trends, problems and potential solutions
Publication -
Monitoring parametrów technicznych odbieraków prądu w warunkach ruchowych na linii kolejowej
PublicationOpracowany w Katedrze Inżynierii Elektrycznej Transportu Politechniki Gdańskiej układ monitoringu parametrów technicznych odbieraków prądu pozwala wykryć ich niesprawność w warunkach ruchowych na linii kolejowej. Ocenę stanu technicznego oparto na pomiarze i analizie uniesienia dynamicznego przewodów sieci jezdnej w momencie przejścia odbieraka pojazdu przez punkt pomiarowy. Przekroczenie granicznej wartości uniesienia, wynikające...
-
Determination of COD Fractionation as a Key Factor for Appropriate Modelling and Monitoring of Activated Sludge Processes
PublicationAn operation of wastewater treatment plant is usually controlled by global parameters such as flow, solids retention time, sludge age, concentration of ammonia and dissolved oxygen, etc. It is considered that, together with the chemical and biological oxygen demand (COD and BOD), those parameters indirectly exhibit the effectiveness of activated sludge processes. Especially the BOD indicate the amount of organic pollution that...
-
Impedance monitoring of corrosion degradation of plasma electrolytic oxidation coatings (PEO) on magnesium alloy
PublicationImpedance technique based on continuous multisinusoidal current perturbation was used to explain degradation process of plasma electrolytic oxidation coatings (PEO) on magnesium alloy. An obtained impedance spectrum was fitted by electrical equivalent circuit to describe properties of conversion layer on magnesium alloy. Additionally, galvanostatic mode maintained during experiment, with DC current equal to zero, allowed to achieve...
-
Monitoring dojrzewania betonu skrzynki mostu MS3/B DK-16 - sekcja S3.18P
PublicationCelem niniejszego opracowania jest przeprowadzenie badań modułów sprężystości betonu klasy C60/75 oraz monitoring zmian temperaturowych w wybranych punktach sekcji S3.18P. System pomiaru temperatury służy także do wyznaczenia rzeczywistych wytrzymałości betonu w trakcie dojrzewania, sformułowania wskazówek dotyczących terminów demontażu deskowań lub weryfikacji terminów rozpoczęcia procesu sprężania konstrukcji.
-
Alternative diagnostic method applied on marine diesel engines having limited monitoring susceptibility
PublicationThe paper presents a method of technical state evaluation of working spaces of a marine diesel engine at the limited control susceptibility. The method foresees making a diagnosis of the engine's working spaces on the basis of measurements of the exhaust gas pressure in the channels connecting engine cylinders with the turbocharger's turbine. Diagnostic measurements are carried out at representative (comparative) steady loads depending...
-
Strain gauges monitoring of arch bridge over the Vistula river in Toruń during construction
PublicationIn 2013 one of the biggest Polish road bridges over the Vistula was built in Torun. Considering the use of original engineering solutions and innovative assembly it was decided on monitoring of strain gauges and assessment of building’s behaviour during its construction. The research was aimed at determining the degree of strain and the assessment of proper work of main arch girders during assembly phases. This work presents the...
-
Aptamer based tools for environmental and therapeutic monitoring: A review of developments, applications, future perspectives
PublicationNucleic acids in the form of aptamers play a growing and significant role in the targeted and rapid analysis of environmental sample composition and medical analyses. In this paper, the review of both aptamers synthesis methods as well as application of these short chain oligonucleotides (with critical comments on their strong and weak features) are given. The first ones include: systematic evolution of ligands by exponential enrichment...
-
Measurement system for nonlinear surface spectroscopy by atomic force microscopy for corrosion processes monitoring
PublicationIn addition to traditional imaging the surface, atomic force microscopy (AFM) enables wide variety of additional measurements. One of them is higher harmonic imaging. In tapping mode the nonlinear contact between tip and specimen results in higher frequency vibrations. More information available from the higher harmonics analysis proves to be helpful for more detailed imaging. Such visualization is especially useful for heterogeneous...
-
Analysis of Modal Parameters Using a Statistical Approach for Condition Monitoring of the Wind Turbine Blade
PublicationThe primary objective of the presented paper is the numerical and experimental investigation related to developing a useful diagnostic method, which can be used for determining the site and size of damage in laminated shells of wind turbine blades. The described detection technique is based on the analysis of low frequencies bending vibrations mode shapes of rotor blades. The authors used the commonly applied statistics methods...
-
Monitoring the curing process of epoxy adhesive using ultrasound and Lamb wave dispersion curves
PublicationMonitoring the stiffness of adhesives is a crucial issue when considering the durability andstrength of adhesive joints. While there are many studies conducted on specimens madeonly from adhesive, the problem of curing of an adhesive film in real joints is moderatelyconsidered. This paper presents the monitoring of stiffening of epoxy adhesive using ultra-sound. Ultrasonic pulse velocity method was firstly applied for monitoring...
-
Towards spectroscopic monitoring of photoelectrodes: In-situ Raman photoelectrochemistry of a TiO2/prussian blue photoanode
PublicationHere, novel in-situ Raman photoelectrochemical measurements are performed. The obtained results have proved that it is possible to track the progress of a photoelectrochemical reaction that takes place on a semiconducting electrode using the spectroscopic method. As an exemplary system, the Ti/TiO2/Prussian blue electrode is investigated. Since TiO2 is an n-type semiconductor, it cannot act as an efficient anode in dark conditions....
-
DiSTFAG method robust to gross errors in monitoring displacements and strains in unstable reference systems
PublicationThe DiSTFA method (Displacements and Strains using Transformation and Free Adjustment) was presented in Kamiński (2009). The method has been developed for the determination of displacements and strains of engineering objects in unstable reference systems, as well as for examining the stability of reference points. The DiSTFAG (Gross errors) method presented in the paper is the extension of the DiSTFA method making it robust to...
-
Application of electronic nose to effectiveness monitoring of air contaminated with toluene vapors biofiltration process
PublicationThe research presents the application of electronic nose (combined with MLR model) to on-line effectiveness monitoring of biofiltration of air contaminated with hydrophobic, odorous compound (toluene vapors). The research was conducted using two-section biotrickling filter inhabited by Candida environmental isolates. Gas chromatography was used as the comparative technique to obtain reliable quantification of toluene concentration...
-
Monitoring of lysozyme thermal denaturation by volumetric measurements and nanoDSF technique in the presence of N-butylurea
PublicationThe results of thermal studies of denaturation of hen egg white lysozyme (HEWL) in water and an aqueous solution of N-butylurea (BU) are presented. High-precision densimetric measurements were used to characterize and analyze the changes of the specific volume, v, during temperature elevation. The temperature of the midpoint of protein denaturation was also determined by nanoDSF technique (differential scanning fluorimetry). The...
-
Concept of an Innovative Autonomous Unmanned System for Bathymetric Monitoring of Shallow Waterbodies (INNOBAT System)
PublicationBathymetry is a subset of hydrography, aimed at measuring the depth of waterbodies and waterways. Measurements are taken inter alia to detect natural obstacles or other navigational obstacles that endanger the safety of navigation, to examine the navigability conditions, anchorages, waterways and other commercial waterbodies, and to determine the parameters of the safe depth of waterbodies in the vicinity of ports, etc. Therefore,...
-
Monitoring of Caged Bluefin Tuna Reactions to Ship and Offshore Wind Farm Operational Noises
PublicationUnderwater noise has been identified as a relevant pollution affecting marine ecosystems in different ways. Despite the numerous studies performed over the last few decades regarding the adverse effect of underwater noise on marine life, a lack of knowledge and methodological procedures still exists, and results are often tentative or qualitative. A monitoring methodology for the behavioral response of bluefin tuna (Thunnus thynnus)...
-
Tool Wear Monitoring Using Improved Dragonfly Optimization Algorithm and Deep Belief Network
PublicationIn recent decades, tool wear monitoring has played a crucial role in the improvement of industrial production quality and efficiency. In the machining process, it is important to predict both tool cost and life, and to reduce the equipment downtime. The conventional methods need enormous quantities of human resources and expert skills to achieve precise tool wear information. To automatically identify the tool wear types, deep...
-
In-situ monitoring of electropolymerization processes at boron-doped diamond electrodes by Mach-Zehnder interferometer
PublicationIn this work, the Mach-Zehnder interferometer was designed to monitor the electrochemical processes conducted at boron-doped diamond electrode surface. The diamond electrodes were synthesized via Microwave Plasma-Assisted Chemical Vapor Deposition on optical grade quartz glass. The achieved transmittance in working are of diamond electrodes reached 55 %. A cage system-based Mach-Zehnder interferometer was used which allowed the...
-
The electrochemical determination of isatin at nanocrystalline boron-doped diamond electrodes: stress monitoring of animals
PublicationUltra-thin nanocrystalline boron-doped diamond electrodes (B:NCD) were used for the electrochemical determination of isatin in dog urine samples using cyclic voltammetry and square wave voltammetry in a phosphate buffer saline, pH = 7.2. No additional modification or pretreatment of the electrode surface was required in this approach, being of high importance for the facile detection procedure. The increase of the peak current...
-
Frugal Heart Rate Correction Method for Scalable Health and Safety Monitoring in Construction Sites
Publication -
Zastosowanie nieradialnego modelu SBM z ograniczeniami wag do pomiaru efektywności dydaktycznej w szkolnictwie wyższym
Publication -
Zastosowanie programów Mathematica i 20-sim do modelowania i analizy układów o parametrach rozłożonych
PublicationCelem pracy jest zaprezentowanie zastosowania pojęcia transmitancji układów o parametrach rozłożonych do konstruowania modalnych grafów wiązań dla układów zawierających jednowymiarowe podukłady o parametrach rozłożonych. Zaprezentowano sposób i efekty zastosowania programów Mathematica (do przygotowania parametrów modeli) i programu 20-Sim (do konstruowania modeli i do symulacji) w procesie modelowania i analizy układów zawierających...
-
Propozycja procedury oceny bezprzewodowych sieci wifi w środkach transportu publicznego na przykładzie Trójmiejskiej SKM
PublicationW ramach realizacji projektu budowy linii kolejowej pomiędzy Centrum a Lotniskiem Gdańsk Rębiechowo przez spółkę "Pomorska Kolej Metropolitalna S.A", postanowiono zbadać techniczne możliwości udostępnienia Internetu pasażerom na czas podróży. Celem opisanych badań było przetestowanie, w warunkach rzeczywistego ruchu pociągów, możliwości zapewnienia dostępu do Internetu dla pasażerów publicznej komunikacji kolejowej przy zastosowaniu...
-
Phong B. Dao D.Sc., Ph.D.
PeoplePhong B. Dao received the Engineer degree in Cybernetics in 2001, the M.Sc. degree in Instrumentation and Control in 2004, both from Hanoi University of Science and Technology in Vietnam, and the Ph.D. degree in Control Engineering in 2011 from the University of Twente, the Netherlands. In May 2020, Dr. Dao received the degree of D.Sc. (Habilitation) in Mechanical Engineering from the AGH University of Science and Technology, Poland....
-
Electrical properties of nanocrystalline Sm-doped ceria ceramics
PublicationWłaściwości ceramiki z cerii zależa zwykle silnie od struktury ziaren. W pracy przedstawiono właściwości elektryczne ceramiki z cerii domieszkowanej samarem wykonanje w technologii 'net shape' posiadającej strukturę nanokrystaliczną.
-
Anna Dołęga prof. dr hab. inż.
People -
International Journal of Condition Monitoring
Journals -
Environmental Nanotechnology, Monitoring and Management
Journals -
Koncepcja monitoringu dynamicznego oddziaływania odbieraka prądu w warunkach eksploatacyjnych
PublicationW artykule przedstawiono założenia koncepcji wykrywania niesprawnych odbieraków prądu w wybranych punktach na linii kolejowej podczas przejazdu pociągu. Omówiono podstawowe założenia, zaprezentowano schemat planowanego stanowiska laboratoryjnego oraz terenowego. Dokonano analizy czujników pomiarowych spełniających założone funkcje oraz rozważono parametry jakie należałoby wykorzystać do celów diagnostycznych. Zaprezentowano wyniki...
-
Koncepcja monitoringu dynamicznego oddziaływania odbieraka prądu w warunkach eksploatacyjnych
PublicationW artykule przedstawiono założenia koncepcji wykrywania niesprawnych odbieraków prądu w wybranych punktach na linii kolejowej podczas przejazdu pociągu. Omówiono podstawowe założenia, zaprezentowano schemat planowanego stanowiska laboratoryjnego oraz terenowego. Dokonano analizy czujników pomiarowych spełniających założone funkcje oraz rozważono parametry jakie należałoby wykorzystać do celów diagnostycznych.
-
Ocena efektywności monitoringu obiektów inżynierskich za pomocą sieci Bayesa
PublicationW swojej pracy autorzy zaproponowali zastosowanie sieci Bayesa do projektowania monitoringu i podejmowania decyzji w działaniach eksploatacyjnych. Ponadto pokazano dwie metody oceny wartości informacji diagnostycznych. Pierwszą z nich jest wartość oczekiwana EVSI (ang. Expected Value of Sample Information), która stanowi podstawę do wyboru spośród alternatywnych obserwacji symptomów zmiennej diagnostycznej. Natomiast drugą metodą...
-
System monitoringu technicznego w obiektach mostowych - niezbędne czy przydatne?
PublicationW pracy przedstawiono rozważania na temat zasadności stosowania systemów monitoringu technicznego w mostach. Wskazano rodzaje systemów oraz przykłady zastosowań: utrzymanie, bezpieczeństwo oraz weryfikacja założeń projektowych.
-
System do prototypowania bezprzewodowych inteligentnych urządzeń monitoringu audio-video
PublicationW komunikacie przedstawiono system prototypowania bezprzewodowych urządzeń do monitoringu audio-video. System bazuje na układach FPGA Virtex6 i wielu dodatkowych wspierających urządzeniach jak: szybka pamięć DDR3, mała kamera HD, mikrofon z konwerterem A/C, moduł radiowy WiFi, itp. Funkcjonalność systemu została szczegółowo opisana w komunikacie. System został zoptymalizowany do pracy pod kontrolą systemu operacyjnego Linux, zostały...
-
Zastosowanie niskokosztowych czujników PM10 do monitoringu jakości powietrza atmosferycznego
PublicationW pracy przedstawiono wyniki testu terenowego przeprowadzonego na terenie Gdańska w okresie od 7 do 24 lutego 2018 w celu wykazania wiarygodności uzyskiwanych wyników za pomocą komercyjnych czujników PM10 działających na zasadzie laserowego licznika cząstek w stosunku do metody odniesienia.