Filters
total: 1160
-
Catalog
displaying 1000 best results Help
Search results for: ELEKTROCHEM IMPEDANCJA SPEKTROSKOPOWA
-
Detection of stress corrosion cracking dynamics by dynamic electrochemical impedance spectroscopy
Publication -
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublicationLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
Determination of percolation threshold in cement composites with expanded graphite by impedance spectroscopy
Publication -
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublicationThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
Impedance Spectroscopy as a Diagnostic Tool of Degradation of Solid Oxide Fuel Cells
Publicationw pracy przedstawiono wyniki badań degradacji tlenkowych ogniw paliwowych przeprowadzone metodą spektroskopii impedancyjnej. Ogniwa paliwowe zostały przetestowane w eksperymentalnych warunkach, które pozwalają na uzyskanie szybkiego spadku wydajności ogniw paliwowych. impedancja i parametry uzyskane z dopasowania widm do elektrycznego obwodu zastępczego zostały skorelowane z poziomem degradacji elementów ogniw paliwowych - anody...
-
Local impedance imaging of boron-doped polycrystalline diamond thin films
Publication -
The Influence of Thin Gold Electrodes on the High-Temperature Impedance of Oxide Glasses
PublicationThe influence of thin gold electrodes on the electrical measurements of glasses at high temperatures was studied using impedance spectroscopy. The impedance was measured several times over a wide frequency range from 10 mHz to 1 MHz and the temperature ranged from 213 to 673 K under air and nitrogen atmospheres. The results showed a drop in the conductivity of more than an order of magnitude at a temperature around 603 K during...
-
Novel fast non-linear electrochemical impedance method for corrosion investigations
PublicationThe paper presents a novel approach to corrosion rate monitoring using non-linear electrochemical impedance spectroscopy. The authors propose a new variant of non-linear impedance measurement using amplitude-modulated multi-frequency ac perturbation signal. It allows shortening of measurement duration so it is possible to monitor corrosion rate of the systems experiencing rapid changes. In this way a limitation resulting from lack...
-
Diagnosis of reference electrodes in cathodic protection systems by electrochemical impedance spectroscopy
PublicationPrzedstawiono wyniki badań laboratoryjnych i terenowych przeprowadzonych techniką elektrochemicznej spektroskopii impedancyjnej (EIS). Zaprezentowano widma impedancyjne następujących układów: elektroda odniesienia/elektroda pomocnicza; rurociąg/zakopane i przenośne elektrody odniesienia. Pokazano, że omawiana technika umożliwia badanie stanu technicznego elektrod odniesienia, co zwiększa pewność wyników pomiarów potencjału chronionej...
-
Novel application of dynamic electrochemical impedance monitoring to a cataphoretic coating process
PublicationThe paper presents a novel method of on-line impedance monitoring of cataphoretic coating application process. Utilization of dynamic electrochemical impedance spectroscopy (DEIS) overcame the fundamental problem connected with non-stationarity of the aforementioned coating deposition process, which eliminates classical impedance spectroscopy technique from a real-time description of cataphoresis. The paper illustrates selected examples...
-
Remote Monitoring System for Impedance Spectroscopy using Wireless Sensor Network
PublicationThe architecture of a miniaturized impedanceanalyser with wireless communication module for remoteImpedance Spectroscopy (IS) of anticorrosion coatings ondifficult-to-reach objects (e.g. on the steel construction ofthe bridge) is described in this paper. Some practical aspectsof implementation of a Wireless Sensor Network (WSN) arealso discussed. A low scale, middle range, WSN networkcomposed of a Base Station (BS) with a Personal...
-
Finding the protection of lighting grounding with estimating its impulse impedance componets
PublicationOmówiono metodę rozdzielania składowych impedancji udarowej uziemień. Podano wskazania dotyczące oceny jakości ochrony odgromowej na podstawie wartości składowych impedancji udarowej.
-
The application of dynamic electrochemical impedance spectroscopy for stress corrosion cracking studies
PublicationElektrochemiczna Spektroskopia Impedancyjna (ESI) od wielu lat stanowi jedno z najważniejszych narzędzi wykorzystywanych do badania różnych procesów elektrochemicznych. Możliwość przeprowadzania badań w łącznej dziedzinie czasowo-częstotliwościowej ułatwia analizę pomiarów impedancyjnych w czasie. ESI pozwala również na analizę mechanizmu procesów elektrochemicznych w dziedzinie czasu z uwzględnieniem bardzo szybkich zjawisk, takich...
-
Investigations of the passive layer cracking by means of dynamic electrochemical impedance spectroscopy.
PublicationDynamiczna elektrochemiczna spektroskopia impedancyjna została wykorzystana do badania pękania warstwy pasywnej na austenitycznej stali wysokostopowej.Zbadano efekt narzuconego potencjału oraz naprężeń rozciągających na pękanie korozyjne stali wysokostopowej 304L w środowisku 0.5M NaCl w temperaturze pokojowej. Praca przedstawia chwilowe widma impedancyjne uzyskane dla badanego układu przy różnych wartościach potencjałów. Uzyskane...
-
Detection of stress corrosion cracking dynamics by dynamic electrochemical impedance spectroscopy.
PublicationKlasyczne badania korozji naprężeniowej nie dają precyzyjnych informacji o dynamice takiego procesu korozyjnego. Nowa technika dynamicznej elektrochemicznej spektroskopii impedanyjnej, która została opracowana w Katedrze Elektrochemii, Korozji i Inżynierii Materiałowej stwarza takie możliwości. Fakt ten związany z zastosowaną metodologią analizy umożliwiającą selektywną analizą czasowo-częstotliwościową danych pomiarowych.Praca...
-
Impedance spectroscopy by means of a digital storage oscilloscope based measurement system.
PublicationW pracy przedstawiono system pomiarowy służący do badań spektroskopowych. Został on zbudowany w oparciu o szerokopasmowy oscyloskop cyfrowy. Przeprowadzono analizę dokładności pomiarów oraz przedstawiono wyniki badań kalibracyjnych i przykładowych pomiarów parametrów materiałów biologicznych.
-
Quantification of interlayer adhesion in protective coating systems using impedance spectroscopy
PublicationNowoczesne systemy powłokowe stosowane w praktyce są wielowarstwowe. Potencjalnie słabymi obszarami z punktu widzenia właściwości ochronnych są obszary międzywarstwowe. Osiągnięcie odpowiedniej przyczepności pomiędzy warstwami pozwala na polepszenie zdolności ochronnych całego zestawu. Tradycyjne metody pomiaru adhezji międzywarstwowej są destrukcyjne. Zaproponowano nową metodę oceny przyczepności międzywarstwowej przy użyciu...
-
Impedance-based sensing of the interlayer adhesion loss in organic coating systems.
PublicationZmienne parametry środowiska takie jak: temperatura,wilgotność i promieniowanie UV powodują degradację własności ochronnych powłok organicznych. Stosując sensor w postaci elektrod wykonanych z prądoprzewodzącego tuszu umieszczonych pomiędzy warstwami zestawu oraz technikę spektroskopii impedancyjnej stwierdzono możliwość monitorowania utraty adhezji międzywarstwowej.
-
Impedance studies of diffusion phenomena and ionicand electronic conductivity of cerium oxide
PublicationW pracy zbadano właściwości elektryczne tlenku ceru z wykorzystaniem spektroskopii impedancyjnej. Badania wykazały występowania zjawiska dyfuzji, które jest prawdopodobnie związane z blokowaiem jonów na granicy faz. Bazując na zaproponowanym modelu obliczono przewodność elektronowa i jonową tlenku ceru.
-
Application of the dynamic electrochemical impedance spectroscopy to investigation of spontaneous electrochemical oscillations
PublicationPrzedstawione zostały wyniki impedancyjne uzyskane podczas oscylacji prądowych miedzi w kwaśnym środowisku zawierającym jony chlorkowe. Kształt chwilowych widm impedancyjnych jest skorelowany z uzyskanym przebiegiem prądowym. Badany proces anodowego roztwarzania miedzi kontrolowany jest na przemian aktywacyjnie i dyfuzyjnie.
-
Ocena przydatności klasycznych metod pomiaru impedancji pętli zwarciowej do obwodów z wyłącznikami różnicowoprądowymi
PublicationW referacie przedstawiono wyniki badań zachowania się wyłączników różnicowoprądowych przy pomiarze impedancji pętli zwarciowej, wykonanym wybranymi miernikami. Badania przeprowadzono w obwodach z wyłącznikami różnicowoprądowymi o znamionowym prądzie różnicowym równym 30 mA, typu AC oraz typu A. Na podstawie przeprowadzonych badań i analiz zaproponowano sposób pomiaru impedancji pętli zwarciowej, który nie powoduje zbędnego zadziałania...
-
Szacowanie standardowej niepewności złożonej pomiaru impedancji pętli zwarciowej wyznaczonej metodą z przesunięciem psi
PublicationW niniejszym artykule zaprezentowano wyniki szacowania standardowej niepewności złożonej pomiaru impedancji pętli zwarciowej wyznaczonej metodą z przesunięciem . Przeanalizowano wpływ niepewności rezystancji obciążenia pomiarowego, niepewności pomiaru napięć, niepewności pomiaru okresu oraz przesunięcia psi na dokładność pomiaru impedancji pętli zwarcia.
-
Determination of pseudocapacitance chan ges of nickel oxide NiO electrode with use of dynamic electrochemical impedancje spectroscopy
PublicationThe electrochemical capacitors (ECs) are attractive energy storage devices which can be applied in many electronic products (e.g., cameras, laptops, cell phones) or hybrid electric vehicles (HEV). The energy storage in ECs is based on capacitive (the electrical double layer charging/discharging) and pseudocapacitive (additional charge provided by faradic reaction) phenomena. Considering the electrodes exhibiting pseudocapacitance,...
-
Nowe rozwiązania pomiaru impedancji pętli zwarciowej przy odkształceniu krzywej napięcia w miejscu badania
PublicationW pracy przeanalizowano wpływ występujących w sieci czynników wpływających na błędy pomiaru, co umożliwiło ocenę, które znane metody i mierniki impedancji pętli zwarciowej mogą być stosowane w rzeczywistych układach elektroenergetycznych o wyraźnym odkształceniu krzywej napięcia. Przedstawiono nową metodę i przyrząd do pomiaru impedancji pętli zwarciowej oraz jej składowych ortogonalnych – rezystancji i reaktancji, która pozwala...
-
Wpływ pomiaru dokładności napięć na wyznaczenie impedancji pętli zwarciowej metodą z przesunięciem y
PublicationMetoda z przesunięciem y to jedna z metod pomiaru impedancji pętli oparta na pomiarze składowych ortogonalnych napięcia umożliwiająca wyznaczenie wartości impedancji pętli znaczenie dokładniej niż metody klasyczne. Metoda ma posiada szereg zalet. Z racji tego poddawana jest ona ciągłym analizom metrologicznym pozwalającym na realizację modelu fizycznego miernika działającego w oparciu o tę metodę i odznaczającego się jeszcze lepszymi...
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublicationW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...
-
Anna Lisowska-Oleksiak prof. dr hab.
PeopleAnna Lisowska-Oleksiak, born in 1952, has been working at GUT since 1977. Currently is employed at the Faculty of Chemistry as a full professor. She was employed as a research assistant at the University of St Andrews in the group of C. A. Vincent and P.G. Bruce (1991-1994). She completed a two-month research internship in CEA Grenoble (2011). Anna Lisowska-Oleksiak obtained her MSc in chemistry at Nicolaus Copernicus University...
-
Identification of the mechanical properties of the skin by electromechanical impedance analysis of resonant piezoelectric actuator
PublicationThis paper is devoted to the analysis and verification of developed piezoelectric sensor/actuator for measuring the mechanical properties of soft tissues, especially human skin. The key element of the measurement structure is an electromechanical system that uses both the reverse piezoelectric effect (vibration generation – stimulation of the tissues in the appropriate frequency range) and direct piezoelectric effect (system response...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublicationW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Time evolution of Electrochemical Impedance spectra of cathodically protected steel in artificial seawater
PublicationUsability of Electrochemical Impedance Spectroscopy data for better cathodic protection control was investigated. Carbon steel – S235JR2 grade specimen were exposed in artificial seawater environment. Samples were polarized and their potentials corresponded to four different cathodic protection degrees. Time evolution of Electrochemical Impedance spectra was investigated. Goodness of fit function (X2) was analysed in terms of proper...
-
Biosilica from sea water diatoms algae—electrochemical impedance spectroscopy study
PublicationHere, we report on an electrochemical impedance study of silica of organic origin as an active electrode material. The electrode material obtained from carbonized marine biomass containing nanoporous diatoms has been characterised by means of XRD, IR, SEM and EIS. Dif- ferent kinds of crystallographic phases of silica as a result of thermal treatment have been found. The electrode is electrochemically stable during subsequent cyclic...
-
Comparison of Impedance-Source Networks for Two and Multilevel Buck–Boost Inverter Applications
Publicationmpedance-source networks are an increasingly popular solution in power converter applications, especially in single-stage buck-boost power conversion to avoid additional front-end dc-dc power converters. In the survey papers published, no analytical comparisons of different topologies have been described, which makes it difficult to choose the best option. Thus, the aim of this paper is to present a comprehensive analytical comparison...
-
Nonlinear and linear impedance of bismuth vanadate ceramics and its relation to structural properties
PublicationThe nonlinear and linear electrical properties, topography, and microstructure of bismuth-vanadate ceramics, were studied. The structurewas observed with the use of X-ray diffraction (XRD), scanning electronmicroscopy (SEM), atomic force microscopy (AFM) and confocal microscopy methods. The obtained results showed that ceramic is porous. Two phase transitionswere determinedwith the use of DSC measurements. The linear and nonlinear ac...
-
Response features for fast EM-driven design of miniaturized impedance matching transformers
PublicationA framework for low-cost EM-driven design optimization of compact impedance matching transformers is presented. Our technique is based on a bottom-up design where design requirements for the transformer circuit are translated into specifications for its building blocks. These elementary cells are optimized using response features. Subsequently, the entire circuit is fine-tuned using local response surface approximation models and...
-
Impedance characterization of the process of polyaniline first redox transformation after aniline electropolymerization
Publication -
Use of impedance spectroscopy to evaluate the durability of protective coatings after thermal shock
Publication -
Influence of the analyzing window on electrode impedance measurement by the continuous frequency scanning method
Publication -
Impedance monitoring of carbon steel cavitation erosion under the influence of corrosive factors
PublicationW pracy przedstawiono wyniki badań degradacji stali węglowych na skutek oddziaływania erozji-korozji kawitacyjnej. Do analizy wykorzystano technikę Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej oraz funkcję ubytku masy powszechnie stosowaną do oceny odporności kawitacyjnej materiałów. Oszacowanie stopnia degradacji powierzchni, a także wpływu erozji na odporność korozyjną jest możliwe po zastosowaniu odpowiedniego elektrycznego...
-
Method using square-pulse excitation for high-impedance spectroscopy of anticorrosion coatings
PublicationArtykuł prezentuje metodę spektroskopii impedancyjnej przeznaczonej do diagnostyki powłok antykorozyjnych na obiektach bezpośrednio w terenie. Aby skrócić czas uzyskania widma impedancji (w zakresie od 1 mHz do 1 MHz) do kilku minut, wykorzystano sygnały harmoniczne do pomiaru widma powyżej 10 Hz a impuls prostokątny w dolnym zakresie częstotliwości. Do wyznaczania widma użyto algorytmów DSP odpowiednich do sygnału pobudzenia....
-
Interface circuit for impedance sensors using two specialized single-chip microsystems
PublicationW artykule przedstawiono obwód interfejsu przeznaczony do pomiaru parametrów impedancyjnych czujników lub celek pomiarowych instalowanych na obiektach technicznych. Umożliwia on pomiar modułu i argumentu impedancji w zakresie 10ohm
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublicationW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
Electrochemical Evaluation of Sustainable Corrosion Inhibitors via Dynamic Electrochemical Impedance Spectroscopy
PublicationFinding suitable measurement methods for the effective management of electrochemical problems is of paramount importance, particularly for improving efficiency in corrosion protection. The need for accurate measurement techniques specific to nonstationary conditions has long been recognized, and promising approaches have emerged. This chapter introduces dynamic electrochemical impedance spectroscopy as a novel advancement in electrochemistry...
-
Application of Electrochemical Impedance Spectroscopy to evaluate cathodically protected coated steel in seawater
PublicationTwo types of organic coated carbon steel (S235JR2 grade) electrodes were exposed to artificial seawater environment. One prepared type was defect free while the other one had an intentionally introduced φ0,5 cm coating defect. Both kinds of samples were polarized during the exposure to four potentials corresponding to four different cathodic protection levels. Evolution of their EIS spectra is presented in this paper. Results obtained...
-
Water uptake in protective organic coatings and its reflection in measured coating impedance
PublicationWater uptake in commercially available epoxy coating on mild steel using impedance spectroscopy and gravimetry was studied. The water content in the coating was determined using the Brasher-Kingsbury equation and various methods of coating capacitance calculation used in the literature. The obtained results were compared with reference gravimetric data. An overestimation of values obtained from impedance data in relation to gravimetric...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Galvanostatic impedance measurements for the efficient adsorption isotherm construction in corrosion inhibitor studies
PublicationWe present an approach towards an accurate and time-efficient adsorption isotherm determination to evaluate the corrosion inhibitor interaction in electrolytic environments. The approach is based on dynamic impedance spectroscopy measurements in galvanostatic mode (g-DEIS). The studied corrosion inhibitor is continuously injected between the secondary cell and the corrosion cell. The efficiency corresponding to instantaneous inhibitor...
-
Communication Model Order Reduction in Hybrid Methods Involving Generalized Impedance Matrix
PublicationA novel strategy for the efficient analysis of frequency-domain scattering electromagnetic problems in open and closed domains is presented. A fully automatic model-order reduction technique, called the enhanced reduced-basis method, is applied to increase the efficiency of the hybrid approach, which combines the finite-element and mode-matching methods. Numerical tests show that the proposed algorithm yields reliable and highly...
-
Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis
PublicationStarvation, flooding, and dry‐out phenomena occur in polymer electrolyte membrane fuel cells (PEMFCs), due to heterogeneous local conditions, material inhomogeneity, and uneven flow distribution across the single cell active area and in between the individual cells. The impact of the load level and air feed conditions on the performance was identified for individual single cells within a 10‐cell stack. Analysis of the current density...
-
Instantaneous impedance monitoring of synergistic effect between cavitation erosion and corrosion processes
PublicationThe most common method of determination of cavitation erosion resistance as well as the magnitude of erosion-corrosion synergistic interaction is based on the weight loss measurements. Nondestructive characterization of installations elements is in most cases impossible to perform. Also, such a measurement does not include local types of failure or alteration of operating conditions. There is an urge to elaborate a method for monitoring...